Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC | L1 | Accepted-AOC L1 |
| Sl No | Description | Qty | Unit | Shivam Enterprises L1 |
|---|---|---|---|---|
| 1.00 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sqmm | 10 | Metre | 26 ₹260 Lowest |
| 2.00 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm | 13 | Metre | 37 ₹481 Lowest |
| 3.00 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia
including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required | 4 | Nos | 4,354 ₹17,416 Lowest |
| 4.00 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring /cable as required. | 260 | M | 41 ₹10,660 Lowest |
| 5.00 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. | 8 | M | 200 ₹1,600 Lowest |
| 6.00 | P&F following sizes of PVC insulated and PVC Sheathed copper conductor 3 core submersible cable confirming to IS 694/1990 etc. as required. (a) 3x2.5 sqmm | 270 | M | 90 ₹24,300 Lowest |
| 7.00 | SITC of 8 to 10W LED cone type bollard made up of pressure die cast powder coated housing with poly carbonate diffuser , high efficiency long life , surge voltge , over voltage protection , open circuit, short circuit protection and other safety test as per IS 15885 as per part -2 etc as required. | 28 | Nos | 4,549 ₹1,27,372 Lowest |
| 8.00 | Supply of XLPE insulated,PVC sheathed Al.conductor Armoured Cable Conforming to IS 7098/1988 of following Sizes (a) 2 X6 SQmm | 23 | M | 95 ₹2,185 Lowest |
| 9.00 | Providing and laying in position cement concrete 1:3:6(1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required | 17.33 | cum | 7,389 ₹1,28,051.37 Lowest |
| 10.00 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) | 280 | M | 216 ₹60,480 Lowest |
Tender Value
₹5.0 L
EMD Value
₹10,000
Closing Date
9 Feb 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (Electrical)/South Zone
SOUTH DELHI MUNICIPAL CORPORATION Office of the Executive Engineer (Electrical)-IV MC Primary School, Police Colony Hauz Khas, New Delhi-110016
Improvement of lighting arrangement at passage from Gate no. 1, N block GK 1 in ward no. 86S under South Zone.
2022_SDMC_104136_1
NIT NO.28 ITEM NO.01 (2021-2022)
Open Tender
Electrical Works
Item Rate
1125 days
GREATER KAILASH 1
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹10,000
26 Dec 2025
3 Feb 2022
10 Feb 2022
3 Feb 2022
9 Feb 2022
3 Feb 2022
30 days
Amount
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring /cable as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
P&F following sizes of PVC insulated and PVC Sheathed copper conductor 3 core submersible cable confirming to IS 694/1990 etc. as required. (a) 3x2.5 sqmm
SITC of 8 to 10W LED cone type bollard made up of pressure die cast powder coated housing with poly carbonate diffuser , high efficiency long life , surge voltge , over voltage protection , open circuit, short circuit protection and other safety test as per IS 15885 as per part -2 etc as required.
Supply of XLPE insulated,PVC sheathed Al.conductor Armoured Cable Conforming to IS 7098/1988 of following Sizes (a) 2 X6 SQmm
Providing and laying in position cement concrete 1:3:6(1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
Providing and fixing stainless steel name plate of size 6x8 sqinch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required.
Comprehencive AMC of 8 to 10W LED cone type bollard made up of pressure die cast powder coated housing with poly carbonate diffuser including circuit wiring with PVC insulated and PVC Sheathed copper conductor 3 core submersible cable confirming to IS 694/1990 of size 3x2.5 sqmm, main supply XLPE insulated,PVC sheathed Al.conductor Armoured Cable Conforming to IS 7098/1988 of size 2x6 sqmm,Earthing including GI looping and Pillar Box of size 900mm x450mmx250mm including existing isolator and MCB for 02 years in contiuation after the 01 year of completion of installation work
Excavation of the cable trenches in hard rock not exceeding 1.5 meter in width, and lift upto 1.5 meter, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 meter
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Pole and neutral
SITC of Pillar Box of size 900mm x450mmx250mm suitable for mounting incomer of 250 A MCCB/Main switch 4 pole and energy meter 3 phase complete with eleethoypic grade aluminium bus bar of size 25mm x 19mm mounted on galvanised M.S. body powder quoted pilferage proof SMC door duly painted welded with SS with rain cover size 40mm x 40mm x 5mm x600mm height in cuting 300mm height below ground and covered with shade proof SMC sheet of 3 mm as required.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .