Executive Engineer STD Ganderbal
Office of the Executive Engineer STD Ganderbal
SITC of 100kVA, 11 by 0.433kV Auxiliary Distribution Sub Station with installation of 9 Mt long ST Poles for Outgoing feeders at Receiving station Dawar Gurez 6.3 MVA, 33 by 11 KV
2023_PDD_202656_1
STD GBL 41 OF 2022-23 DATED 17-01-2023
Open Tender
Electrical Works
Item Rate
60 days
Dawar Gurez
Refer SBD
10 documents required · 10 mandatory
₹1,000
Yes
Office of the Executive Engineer STD Ganderbal
₹12,810
Yes
7 Mar 2023
17 Jan 2023
9 Feb 2023
17 Jan 2023
8 Feb 2023
25 Jan 2023
17 Jan 2023 - 8 Feb 2023
Amount
SITC of 100kVA, 11/0.433kV Auxillary Distribution Sub station with installation of 9 Mt long ST Poles for Outgoing feeders at Receiving station Dawar Gurez (6.3 MVA, 33/11 KV)
SITC of 11/0.433kV, 3-phase,100kVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2 and with LV Cable Box having detachable Al. Gland plate with LV Bimetallic terminal connection suitable for vertical take off of cable. ( X-mer without OCTC (Off Ckt Tap Changer).
SITC of 11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
SITC of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
SITC of 11 kV Horn Gap Fuse Set 3 Phase 200A
Providing, laying, testing & commisioning of 120mm², single core Cable,1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type.
SITC of 9 mtr ST. Poles (ST-410 SP33)
SITC of 50 mm² ACSR Conductor
SITC of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
SITC of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing and fixing of GI Channel/Angle/Flat of sizes including clamps
Providing and fixing of Galvinized Nuts and Bolts.
Providing & fixing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing & fixing Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm
SITC of LT Distribution Box for:- i)100 kVA DTR with 160 MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 2 No.s for Outgoing Circuits.
Providing & fixing of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6) mm, nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Supply & fixing of PG Clamps for 50mm ACSR
Supply and fixing of Danger Plates with Clamps
Supply and fixing of Anti Climbing devices
Providing & fixing of Cement bottoming 1:2:4 mix as per Standards 0.5 cum/pole
Supply & Painting of Poles with Red Oxide
Supply & Painting of Poles with Aluminium Paint
Providing & fixing of Sundry items like Aluminium lugs, Jumpers, Binding Tape,
M/S RB POWER SOLOTIONS
M/S BHAT POWER PVT. LTD.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .