Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 CrAccepted-AOC | ₹6.3 Cr | L1 | Accepted-AOC Being lowest tender |
| 2 | L2₹7.0 Cr+₹68.5 L (10.9%)Rejected-Finance 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA | NORTH WEST DELHI | DELHI | 110035 | ₹7.0 Cr+₹68.5 L (10.9%) | L2 | Rejected-Finance Higher than lowest tender |
| 3 | L3₹8.6 Cr+₹2.3 Cr (37.2%)Rejected-Finance 61 LAALA LAJPAT RAI COLONY BHOPAL M P 462023 | BHOPAL | MADHYA PRADESH | 462023 | ₹8.6 Cr+₹2.3 Cr (37.2%) | L3 | Rejected-Finance Higher than lowest tender |
| 4 | L4₹9.1 Cr+₹2.8 Cr (44.6%)Rejected-Finance | ₹9.1 Cr+₹2.8 Cr (44.6%) | L4 | Rejected-Finance Higher than lowest tender |
| 5 | L5₹10.2 Cr+₹4.0 Cr (62.9%)Rejected-Finance 2ND FLOOR 9 EZRA STREET KOLKATA WEST BENGAL 700001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹10.2 Cr+₹4.0 Cr (62.9%) | L5 | Rejected-Finance Higher than lowest tender |
Tender Value
₹9.4 Cr
EMD Value
₹7.9 L
Closing Date
3 Mar 2025, 6:00 pmClosed
Sh Somesh Kumar IDSE CE
HQ CHIEF ENGINEER KOLKATA ZONE, MILITARY ENGINEER SERVICES, BALLYGUNGE MAIDAN CAMP, GURUSADAY ROAD KOLKATA-700019
ADDN/ALTN AND SPL REPAIR TO MD ACCN AT STRAND LINE UNDER GE CENTRAL KOLKATA
2024_MES_690324_1
89093/E8
Open Tender
Civil Works
Item Rate
Strand Line Kolkata
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE (Central) Kolkata
₹7.9 L
Yes
29 Apr 2025
26 Dec 2024
10 Mar 2025
26 Dec 2024
3 Mar 2025
24 Feb 2025
Amount
Consultancy services for structure audit in following buildings to find out distressed roof slabs and preparation of detailed project report and structure design and drawings of these roof slabs/beams/chajjas/ walls and check present condition of structures and also find out: 1. List of buildings which has structurally sound and floor slabs/roof slabs/beams/chajjas/columns/walls of these building can be repairs in normal maintenance. 2. Prepare structure design and drawings of balance distressed roof slabs/beams/columns/chajjas etc. as per IS 456: 2000, IS 1893: 2016 & IS 13920: 2016(with latest revision) with loading in accordance of IS 875 & IS 1893. The seismic provisions shall be incororated for zone IV. (a) Consultant shall solely be responsible for arrangement of T & P, transportation and residence etc for their staff without any extra cost. (b) The consultant required to be submitted the detailed project report and drawings in four hard copy along with a soft copy in CD & shall be vetted for IIT/NIT only. : (c) Details of Buildings and area as mentioned in list of building of particular Specification 'NOTE -1: Consultancy for health assessment of building/structures repair/ retrofitting work including: the following deliverables will be provided for the proposed Health Assessment Job a) Visual Inspection Report. b) NDT & Non-NDT Test Reports. c) Health Assessment report including interpretation of test results, statistical & comparative analysis, suggestion/recommendation of repair/retrofitting methods including methodology for retrofitting works, material specification, work specification, detailed estimate for verification of quantities/specification as per related items of BOQ for buildings under the scope. d) Identify all the deteriorated Elements by Visual Inspection.
e) Ascertain the residual strength of those elements from DT/NDT tests. f) Recommendation to strengthen the elements. g) Recommendation for Economic repairing/retrofitting technologies. h) Detailed repair methodology as per deteriorated Elements location details. i) Item Specification and work specification in terms of safety, materials, manpower & equipment. j) Visit at site during the construction period. k) Submit the detailed estimate for Structural retrofitting items.. m) Checking of the strength of repaired members. n) The consultant shall be present at all times during the execution of the structural repair scheme for technical supervision being highly technical job. 'NOTE-2 : Testing and reporting of Rebound Hammer Test, USPV Test, Half Cell Potentital Test, Carbonation Test, Cover Meter Test, Rebar Scan Test, Core Test for Concrete, Chemical tests (PH,Chlorides & Sulphates on core cut samples) 'NOTE-3 : As per E-in-C's Branch policy in vogue a qualified specialist firm with experience and provn track record in the field of structural audit will only be contracted/hired for structural audit/retrofitting and structural repair. NOTE-4 : All Buildings/ structural audit/retrofitting and structural repairs executed based as the latest Technology in vogue.
Demolition of brick or strone / boulder work built in cement mortar including all quoins, arches, pillars etc complete upto 4th storey all as specified and directed.
Material and labour brick work with flyash brick straight or curved on plan exc. 6m mean radius , built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.(Old size bricks)
Taking down cement plaster of any description, including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.(upto 04 storey High of building)
M&L for Rendering 15mm thick in CM (1:6) on other than fair face of brick work or concrete surfaces and finished the surface even and smooth without using extra cement to match the existing surface all complete in all respect as specified.(upto 04 storey High of building)
M&L for plaster on ceiling 5 mm thick in cement mortar (1:3) on concrecte surface , surface finished even and fair with out using extra cement complete all as specified and directed.(upto 04 storey High of building)
M&L for Rendering 20mm thick in two layers (Top 10mm thick rendering coat mixed with water proofing compound shall be laid over 10mm thick plastered surface) with CM (1:4) on of brick work or concrete surfaces finished the surface even and smooth without using extra cement to match the existing surface complete in all respect as specified.(upto 04 storey High of building) Note: WPC shall be measured and paid separately.
M&L for applying 20 mm thick in CM 1:2 (mixed with integral water proofing compound) for likage/cracks etc. to horizontal or vertical surfaces of brick work including necessary formwork after applying evenly a coat of blown type bitumen at the rate of 1.50 kg/sqm and blinding with clean dry sand @ 0.05 cum/sqm applied on verticle surface of wall complete all as specified by Eng-in-Charge. (Note: WPC shall be measured and paid separately)
Supply only Integral water proofing compound complete in all respect as specified.(upto 4 storey High of building)
M&L for preparation of new plastered surface of walls and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over a coat of 1.5mm thick wall care putty over new surfaces complete all as specified & directed.
M&L complete removal of old decorated surfaces and Finishing walls and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over a coat of 1.5mm thick wall care putty over new surfaces complete all as specified & directed.
M&L for preparation of new plastered surfaces and applying three coats of white wash on ceiling complete in all respect as specified.(upto 04 storey High of building).
M&L complete removal of old decorated surfaces of old surface and applying three coats of white wash on ceiling to match with the new one all complete in all respect as specified.(upto 04 storey High of building)
M&L for preparation of new plastered surfaces of wall and applying two coat of oil emulsion distemper over a coat of alkali-resistant primer and over a coat of 1.5mm thick wall care putty complete in all respect as specified.(upto 04 storey High of building)
M&L preparation of old decorated surface by complete removal of existing treatment, washing, rubbing, stopping etc and applying two coat of oil emulsion distemper over a coat of alkali-resistant primer and over a coat of 1.5mm thick wall care putty to match with the new suface on wall. complete in all respect as specified.(upto 04 storey High of building)
Dismantiling of floor, hearth or wall tiling including cement mortar (but not backing), and rubbish off the premises (out of MOD land),complete in all respect as specified..(upto 04 storey High of building)
M&L non-skid ceramic (coloured) tiles 7-8mm thick square/ rectraingular area of each tiles exeeding 0.06sqm but not exceeding 0.11 sqm in toilet/bath floor etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match complete,including over screed bed or bedding layer 15 mm thick in cement mortar (1:6) for laying floor finishes over @ 3 Kg per Sqm Cement slurry complete all as specified and directed.
M&L non-skid ceramic (coloured) tiles 7-8mm thick square/ rectraingulararea of each tiles exeeding 0.11sqm but not exceeding 0.18 sqm in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match complete, including over screed bed or bedding layer 15 mm thick in cement mortar (1:6) for laying floor finishes over @ 3 Kg per Sqm Cement slurry complete all as specified & as directed .
M&L non-skid ceramic (coloured) tiles 7-8mm thick square/ rectraingular area of each tiles exeeding 0.11sqm but n.exceeding 0.18 sqm in skirting etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match complete, including over screed bed or bedding layer 10 mm thick in cement mortar (1:3) over @ 4 Kg per Sqm Cement slurry complete all as specified & as directed .
M&L Glazed ceramic coloured wall tiles of sizes of 450X350X7mm / 450 X300X7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, including over screed bed or bedding layer 10 mm thick in cement mortar (1:3) over @ 4 Kg per Sqm Cement slurry complete all as specified & as directed.(upto 04 storey High of building).
M&L for 16-18 mm thick Green Marble (of any type) work (table rubbed and polished) in , cooking platforms and like over and including 15mm thick cement mortar bedding (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with Green Marbleover @ 4 Kg per Sqm Cement slurry complete in all respect as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete in all respect as specified and directed by Engr-in-Charge.
Dismantling of stone slabs and tiles of any description or thickness in floors surfaces, etc laid cement mortar complete all as specified and directed by Engineer-in-charge. (upto 04 storey high building)
M&L for Machine cut kota stone slab flooring in steps 20-25 mm thick over 15 mm thick cement screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed. (upto 04 storey high building)
M&L for Machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed over 10 mm thick backing coat in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed. (upto 04 storey high building)
Demolition of reinforced cement concrete of any description and in any position not other wise specifiy provided for complete in all as specified and directed. (upto 4 storey High of building)
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete in all as specified and directed. (upto 04 storey High of building)
S&F TMT bars 6 to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete in all as specified and directed. .(upto 04 storey High of building)
M&L for RCC (Nominal Mix) for Type B1 1:2:4 (20 mm graded aggregate) as in Kitchen Platform and similar work all as specified and directed (upto 04 storey of building).
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F for framed work such as grills, gratings, etc.with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engineer-in-charge.(upto 04 storey High of building).
Material & labour preparation of new steel and iron surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide or zinc chrome primer complete in all respect as specified. (upto 04 storey High of building)
M&L for two coats of synthetic enamel paint over a coat of pink primer exc.10cm width or girth over new wooden surfaces including preparation of surface complete all as specified and as directed by Engineer-in-charge.(upto 04 storey High of building).
M&L for one coat of synthetic enamel paint on old wooden surfaces exc.10cm width or girth including preparation of surface complete in all respect as specified (upto 04 storey High of building)
Taking down of Chowkhat with shutter (without taking of shutters from the frame) door / window area n.exc 1.5 Sqm complete all as specified and directed.
Taking down of Chowkhat with shutter (without taking of shutters from the frame) area exc 1.5 Sqm but not exc 4.0 Sqm complete all as specified and directed.
Taking down shutters of any description exceeding 1.00 Sqm and n.exc.2.00 Sqm each complete all as specified and directed. (upto 04 storey high building)
Resecuring or easing and adjusting and refixing in same opening of shutters of any description exceeding 1.00 Sqm and n.exc.2.00 Sqm each complete all as specified and directed. (upto 04 storey high building)
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified.(upto 04 storey High of building)
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & nails with suitable PVC sheet beading and jointing together with solvent cement suppling& fixing in the frame at site complete as per specification & drawing complete all as specified. (upto 04 storey High of building)
S&F 125 mm long Aluminium handles, cast type, anodised complete all as specified.(upto 04 storey High of building)
S&F 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified.
S&F 100 mm long Aluminium anodised, barrel tower bolts of extruded section complete all as specified.(upto 04 storey High of building)
S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified. (upto 04 storey High of building)
S&F 30mm thick 2nd class hard wood glazed & skleton shutters, open rebated and prepared to received glass, gauge etc.(without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR Part-I section 8, clause 8.24(a) complete all as directed. (upto 04 storey high building)
S&F 200 mm long Aluminium anodised, barrel tower bolts of extruded section complete in all respect as spd
S&F 300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified. (upto 04 storey High of building)
S&F powder coated aluminium 50 micron anodised three way track sliding windows of frame size 92mm x 31.75mm x 1.5mm thickness weight of 1.07Kg/m (Section No 20831 of Jindal) and of shutter size 40mm x 18mm (with 9.00 mm interlocking legs) x 1.45 mm thickness (section No 20737 of Jindal) section two shutter glazed, cover half of span of opening each & one shutter skeleton) including provn for making window air tight including 95mm aluminium handle with spring lock, stainless steel wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.4mm and fixed with steel wire staples 5 mm thick plain glass including necessary fitting and fixture, aluminium snap beading with anodised aluminium grill of approved design/pattern according to IS:1868 complete all as specified. Note - Measurement shall be taken clear opening ie out to out of window frame as a whole including all fittings and fixture after taking down steel window complete all as specified & directed by Engr-in-Charge. Note: Cost of glass and wire cloth are inclusive in the item of work.
S&F Powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium frame for ventilators with one or more rebates including joining cleat for fixing ,glazing clips, rubber packing, anodised aluminium snap on beading for fixing glass panes in frames etc.and anodised aluminium grill of approved design/pattern according to IS:1868 complete with following specification .(a) Aluminium frame of size 63.5 mmx38.1 mm of thickness 1.70 mm of wt 0.901 Kg/Rm (section code:14013 of jindal or Equivalent). (b) Rail & Stile size 63.5 mmx38.1 mm of thickness 1.70 mm of wt 0.901 Kg/Rm (section code:14013 of jindal or Equivalent).(c) Std Aluminium C channel sec for Louvrs of 0.092 Kg/Rm (Section code :15601 of jindal or Equivalent) (d) 4.8 mm thick frosted sheet glass. Note:- All ventilators/louvers member including fitting & fixture shall be deem to included in the rate. Only measure opening size of ventilators/louvers
M&L for 18/19 mm thick Prelaminated particle board (fixed in repairs), interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work(for bedroom cupboards). (upto 04 storey High of building)
S&F for stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples for new doors and for repair complete all as specified and directed. (upto 04 storey high building)
S&F for pressed steel frames for doors size 125x60mm double rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified. (upto 04 storey high building)
S&F for pressed steel frames for doors size 105x60mm single rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified (upto 04 storey high building)
M&L PCC 1:2:4 type B0(12.5 mm graded aggregate) for Providing, cement concrete in filling of pressed steel door frame as complete as specified and directed.
S&F 150mm long aluminium anodised handles,cast type complete all as specified and as directed by Engineer-in-charge.(upto 04 storey High of building).
S&F 125mm butt hinges stainless steel medium weight complete all as specified and as directed by Engineer-in-charge.(upto 04 storey High of building).
S&F for aluminium anodised 100mm size hasp and staple, including bolt to hinge plate and fixed with screws complete all as specified and as directed by Engineer-in-charge.. (upto 04 storey High of building).
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, 150mm long complete all as specified and directed (upto 04 storey High of building).
S&F Mild Steel 300mm size ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F for 40mm dia cupboard knobs fixed with nut screws and washer of wooden finish brass polished complete all as specified and directed. (upto 04 storey High of building).
S & F in repair tubular 20mm decorative curtain rod aluminium anodised complete all as specified and directed.
S&F in decorative brackets for curtain rod in any size complete all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.and cutting chases for concealed water tubing etc., and making good, cutting not exc 10 cm girth complete all as directed.
S&F in repair 25 mm bore in repair gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all respect as specified.(upto 4 storey High of building)
S&F 15mm bore in repair Brass CP bib cock fancy type with crutch or butterfly handle chromium plated fancy type complete all as specified.(upto 4 storey High of building)
S & F in repairs 15 mm Dia CP stop cock(concealed type) , with crutch handle,screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as directed. (upto 04 storey High of building)
S & F in repairs 15 mm Dia CP angular cock fancy type, with crutch handle,screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as directed.(upto 04 storey High of building)
S&F in repair brass CP Shower roses in repair with or without swivel joints, 125mm size, including fixing to steel pipes or union complete all as directed.(upto 04 storey High of building)
S&F in repairs Chromium plated Soap dish, fixed to plugs with chromium plated brass screws complete all as directed. (upto 4 storey High of building)
S&F in repair PVC bathroom cabinet box of size 500x400mm fixed on walls complete all as specified & directed by Engr-in-Charge(upto 4 storey High of building)
S & F glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as directed.(upto 04 storey High of building)
S&F in repair Vitreous China wash basin (colour white), angle back, size 550X400 mm, excluding taps, waste,chain and plug and porcelain stopper but including cutting for and pinning in ends of and brackets, waste pipe & PTMT coupling of 32mm dia complete all as specified and directed. Note : Rate quoted under this item deemed included fixing of plug and chain and connecting up to supply pipes, wastes or traps etc.(upto 4 storey High of building)
Supply and fix as in replacement Vitreous China 'White' squatting pan of ‘Orissa pattern’, size 580 mm x 440mm (white) with ‘P’ or ‘S’ trap, front or back inlet and integral foot rests, any pattern complete including provision of PCC bedding and connection to trap, flushing pipe, antisyphonage pipe, etc. (excluding flushing cistern and flush pipe) including making good the disturbed floor complete all as specified and as directed.
S&F PVC connection 15 mm size pipe with PTMT nut of Length 600mm complete all as directed.(upto 04 storey High of building)
S&F in repair 15 mm bore Pillar taps (Fancy type), cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as directed (upto 4 storey High of building).
S&F 10 litres capacity PVC valveless, syphonic action type, flushing cistern, white colour, low level, white with inlet, ball valve, float and handle including brackets duly painted, 32mm dia PVC flush pipe complete all as directed(upto 4 storey High of building).
S&F in repair 100mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as directed.(upto 4 storey High of building).
S&F in repair 110mm bore PVC(SWR) pipe single socket in any length rubber ring joints and fixed to wall complete all as directed. (upto 4 storey High of building)
S&F 110mm bore PVC(SWR) pipe bend single socket complete all as directed.(upto 4 storey High of building)
S&F PVC (SWR) 110 mm bore junction single, (Single T) equal or unequal complete all as directed.
S&F PVC (SWR) 110 mm bore junction double, (Single T) equal or unequal complete all as directed.
S&F PVC (SWR) 110 mm bore branch piece, double (double Y) equal or unequal complete all as directed.
S&F in repair Sinks without drainage board made of stain less steel 1mm thick, kitchen with plugs, washer,waste pipe & PTMT coupling of 32mm dia . Including bedding in cement mortor to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mmx420mm bowl size 410mmx330mmx160mm. Complete all as specified and as directed.
S&F stainless steel kitchen plate rack made out of 1.00mm thick sheet for size 786x914x254mm fixed on wall with screw, washers complete all as specified & directed by Engr-in-Charge
Taking up or down 15mm steel tubing and connections, including cleaning for re-fixing or removal etc.complete all as directed..(upto 04 storey High of building)
S&F CPVC pipes 20 mm outer diameter of SDR 11 & plain CPVC SDR 11 fittings as in walls, ceiling, floor, etc. complete all as specified.(upto 4 storey High of building)
Taking up or down 20mm steel tubing and connections, including cleaning for re-fixing or removal etc.complete all as directed.(upto 04 storey High of building)
S&F CPVC pipes 25 mm outer diameter of SDR 11 & plain CPVC SDR 11 fittings as in walls, ceiling, floor. etc complete all as specified.(upto 4 storey High of building)
S&F in repair tubular towel rail of brass CP , 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building).
Dismantling cast iron pipes of 100mm bore, jointed in cement mortar complete all as directed.(upto 4 storey High of building)
Supply and fix 100mm bore cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls and disturbed portion of the wall making good with cement concrete in (1:2:4) including distance pieces, plugs, holder bats up to any height of building with scaffolding etc cmplete all as specified and as directed by Engineer-in-Charge.(upto 04 storey High of building).
S&F for 100 mm dia CI single, (Single T) equal or unequal complete all as specified and directed. (upto 04 storey high building)
S&F for 100 mm dia CI bends any radius complete all as specified and directed. (upto 04 storey high building)
S&F in repair CI Nahani trap of 100mm dia, including jointing to waste pipe fixed in cement concrete, (1:2:4) type B1 ( using 20 mm graded crushed stone aggregate).complete all as specified and as directed by Engineer-in-charge.. (upto 04 storey High of building).
S&F in repair of 1000 ltrs capacity Rotational moulded polye thylene water storage tanks and including 20mm bore PTMT float and ball valve (cylindrical vertical with closed top) hoisted and fixed in position including Dismantling water tanks and removing to store all as specified in SSR Part-1 complete all as specified and directed. ( 4 storey high building)
Disconnecting of existing tanks 1000 ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) etc, compete all as directed. (04 storey High of building).
Chipping off 25mm average thickness for slabs, Chajja, lintel & roof unsound /week concrete materials up to 4 story bldg by any means as directed by Engr-in-charge including tapering all edges, making regular shape, size and cleaning of exposed concrete surface completely out of any loose foreign materials/aggregate etc and disposal of all debris up to lead of 50mtr complete all as specified & directed by Engr-in-Charge.
All as per above Item but 50 mm average thickness for beams/Lintel
All as per above Item but 60 mm average thickness for Column
Removal of concrete all around above 12mm dia reinforcement including from behind the reinforcing bars to give an average 25mm by manual methods of hammering bar using wire brushing, chiselling etc and removing rust including from behind the reinforcing bars by emery paper and cleaning the area thoroughly by water and allow it to dry and applying alkaline rust removal Reebaklens RR or any equivalent chemical complete all as specified & directed by Engr-in-Charge.
Removal of concrete all around up to 12mm dia reinforcement including from behind the reinforcing bars to give an average 25mm by manual methods of hammering bar using wire brushing, chiselling etc and removing rust including from behind the reinforcing bars by emery paper and cleaning the area thoroughly by water and allow it to dry and applying alkaline rust removal Reebaklens RR or any equivalent chemical complete all as specified & directed by Engr-in-Charge.
M & L for providing single coat of epoxy bond adhesive of prepared non-metallic surface (existing surface) up to 4th Story Bldg and applying by brush all as per manufactures instruction/ specification complete all as specified & directed by Engr-in-Charge.
M & L for applying Zinc rich Anti-corrosive Coating primer on the prepared reinforced surface by brush up to 4 Story Bldg and the primer(n.exc 10 cm width/girth) shall have a minimum specific gravity 1.75 minimum weight film thickness/ coat 40 microns and minimum adhesive bond strength with steel is 1.5N/mm2 complete all as specified & directed by Engr-in-Charge.
M & L for introducing new reinforcement bars n. exc 12 mm dia bar restricted up to 4 storey building for structural connection in RCC beams, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and up to 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc complete all as specified & directed by Engr-in-Charge.
M & L for introducing new reinforcement bars exc 12 mm dia bar restricted up to 4 storey building for structural connection in RCC columns including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and up to 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc complete all as specified & directed by Engr-in-Charge.
M & L for providing and placing in position free flow non-shrink cementitious micro concrete of grade of M-50 to the effected columns etc and the micro concrete shall have a minimum 1 day compressive strength of 10 Mpa and 28 days strength of 60 Mpa, minimum tensile strength 5N/mm2 @ 28 days, minimum flexural strength 5N/mm2 @ 28days complete all as specified & directed by Engr-in-Charge. 60 mm average thickness of column (04 storey High of building).Make : Micro concrete manufacture by M/s Fosroc Chemicals or equivalent make M/s Sika India Pvt Ltd, M/s SNI Infratech Pvt Ltd,M/s STP Limited or any approved of E-in-C's Branch. Note: The rates shall be include all necessary scaffolding and shuttering etc
M & L for providing and placing in position free flow non-shrink cementitious micro concrete of grade of M-50 to the effected beam,chajja etc and the micro concrete shall have a minimum 1 day compressive strength of 10 Mpa and 28 days strength of 60 Mpa, minimum tensile strength 5N/mm2 @ 28 days, minimum flexural strength 5N/mm2 @ 28days complete all as specified & directed by Engr-in-Charge.30 mm average thickness of beam (04 storey High of building).Make : Micro concrete manufacture by M/s Fosroc Chemicals or equivalent make M/s Sika India Pvt Ltd, M/s SNI Infratech Pvt Ltd,M/s STP Limited or any approved of E-in-C's Branch. Note: The rates shall be include all necessary scaffolding and shuttering etc
Supply, mixing and application 'Polymer modified Mortar-Patch repair (Up to Grade M45) Providing and laying Renderoc SP 40 or any equivalent - shrinkage controlled polymer modified single component, alkaline resistant fibre reinforced, thixotropic, cementitious patch repair mortar supplied in 25 kg moisture resistant bag when mixed with clean water at w:p ratio 0.18, achieves compressive strength (BS 1881 Pt.116) -> 20 Mpa at 1 day & > 45 Mpa at 28 days, Tensile Strength(BS 6319 Pt.7) > 2.5 Mpa at 28 Days, Flexural Strength(BS 6319 Pt.3)>7 Mpa at 28 days, Drying shrinkage to ASTM C 157-93, 28 days < 1000 microstrain. Typical application inclues mixing entire bag with clean water about 4.25L to 4.5 L, mixed in suitable container with heavy duty slow speed mixer machine to achieve uniform lump free mortar consistency, placing and finishing the same with trowel carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface on the chajjas, slabs etc., where the thickness of application is less than 50 mm in patches as per specification after applying bonding coat. Item rate is inclusive of materials all labour, tools and tackles, and transportation etc. complete as per specification and as directed by Engg.-in-charge. Payment shall be made as per actual site measurement and upto 4 storey High. Make : SP 40 manufacture by M/s Fosroc Chemicals or equivalent make M/s Sika India Pvt Ltd, M/s SNI Infratech Pvt Ltd,M/s STP Limited or any approved of E-in-C's Branch. Note: The rates shall be include all necessary scaffolding and shuttering etc.
M & L for application of Injection Grouting Providing and executing injection/pressure grouting in cracks in the parent concrete by fixing PVC/Aluminium nipples at 150 mm to 200 mm distance or specified distances as per design and detailed specifications. Pressure grouting using low viscous epoxy grout Conbextra EP10(M) – Moisture insensitive epoxy resin injection material supplied in 1.0 Litre pack which can grout gaps ranging from 0.25mm to 9mm, having mix density 1060 kg/m3, Compressive Strength(ASTM D695)-60/mm2, Tensile Strength(ASTM C307)-20 N/mm2, Flexural strength(BS 6319)-45 N/mm2. Pressure grouting shall be carry out after surface preparations includes fixing nipples and filling cracks with epoxy mortar one day before grouting, injecting low viscous grout mechanically about pressure 3.5 - 7.0 kg/cm² , removing nipple after grouting and sealing with epoxy mortar etc complete as directed by Engr-in-charge. Make : EP10(M) manufacture by M/s Fosroc Chemicals or equivalent make M/s Sika India Pvt Ltd, M/s SNI Infratech Pvt Ltd,M/s STP Limited or any approved of E-in-C's Branch. Note: The rates shall be include all necessary scaffolding and shuttering etc.
Supply and applying two coats of High performance elastomeric cementitious waterproof coating sandwiched with 45 GSM glass fibre reinforcement on the entire floor and 1.0 m of all walls of all toilets as per following methodology:- Cleaning of exposed concrete surface by mechanical means or by hydro blasting to remove laitance, loose particles, contamination etc. which may hinder bonding. Covering of RCC joints with PCC (1:1.5:3) mixed with Integral Water Proofing compound. Applying one coat of Waterproofing membrane to concrete surfaces followed by application of 45GSM glass fibre on the wet surface. Applying second coat of waterproofing membrane at the right angles to the direction of first coat. Second coat shall be applied after the first coat gets dry. Sprinkling fine aggregate immediately after the application of second coat to get the mechanical key for protective plaster. Curing to Water proofing membrane to be carried out for minimum period of 3 days with ponding complete. The Water Proofing Product Should have Mixed density: 1.68g/cc (brushable consistency). Adhesion to concrete : >1N/mm2. Static crack accommodation: 1mm. (upto 04 storey high building). Note: The rates shall be include all necessary scaffolding and shuttering etc.
M&L for uprooting of bushes/scrubs/vegetation from walls of buildings up to extended root and spraying of acid of required quantity complete from any location of buildings up to 4 storied and making good disturbed surfaces with cement mortar (1:4) including necessary scaffolding complete for tree of girth up to 5 to 10 cm & area n. exc 1sq. m complete all as specified & directed by Engr-in-Charge.
Demolition of cement concrete of any description and in any position not other wise specifiy provided for complete in all respect asspecified. (upto 4 storey High of building)
M&L for PCC 1:5:10 Type E2 (using 40mm graded crushed stone aggregate) as in filling sunken floor complete all as specified and as directed by Engineer-in-charge.. (upto 04 storey High of building)
M&L for PCC 1:2:4 type B1 using 20mm graded aggregate for fixing hold fasts, angle etc. complete all as specified and as directed by Engineer-in-charge (upto 04 storey High of building)
M&L for 75mm thick PCC (1:3:6), type C2, using 40mm graded stone aggte as in plinth protection surfae finished even & smooth without using extra cement as complete as specified and directed.
M&L for 150mm thick PCC 1:3:6 type 'C-2' (using 40mm grded stone aggregate ) under floors or pavings etc. complete all as spd and as directed.
M&L Chequered cement concrete tiles 30cm x 30cm x 25mm thick with pigment, set, jointed and pointed in neat cement slurry in floors over 15mm thick screed bed with CM (1:6) complete all as specified and as directed by the Engr-in-Charge.
Stripping of old tarfelt including layer of plaster or mortar of any thickness of earlier treatment carefully from roof surfaces without damaging the roof and roughening of surface of old concrete roofing by picking, sweeping, cleaning and washing down with water to remove dust particle complete all as specified & directed by Engr-in-Charge.
M&L cutting out cracks to "V" section in existing roofs of terracing cleaning out, wetting, grouting, with cement sand slurry 1:3 complete all as specified and as directed by the Engr-in-Charge.(upto 4 storey High of building)
M&L for 15mm thick screed bed or bedding layer in CM 1:4 surface finished even and smooth without using extra cement for padding ccomplete all as specified and as directed by the Engr-in-Charge.
Material and labour for applying tack coat industrial bitumen 85/25 at the rate of 1.2 kg /sqm including cleaning of surface and laying of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on Priming surfaces by forced application and preparation of the new surface and apply one coat of Aluminium paint complete all as specified and as directed by the Engr-in-Charge.
Taking down carefully unserviceable copper / aluminium point wiring (light, fan, bell socket or power) including all fittings such as switches, socket, ceiling roses ,light fittings of any type, regulators and fittings complete and making good the disturbed surfaces all as directed by Engineer-in-Charge.
Material and Labour Point wiring with 1.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core, unsheathed, copper conductor cables drawn through and including PVC conduits Concealed in walls, ceiling etc with all fittings and accessories of PVC conduits (like Tee, bend etc.) complete fixed to walls/ceiling etc. with and including 1.5 Sqmm (nominal area) FRLSH PVC insulated, unsheathed, multistranded, single core, copper cable green in colour as in earth continuity wire connecting to common earth point and 1.6 mm thick mild steel sunken terminal boxes of suitable size with 3 mm thick hylam sheet top cover fixed with suitable size of brass screws for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one, one way switches complete including cutting, chasing the surface and then making good the same in CM 1:3 complete all as specified and directed by the Engr-in-Charge. Note: Colour coding for wiring to be followed, Red/Blue/Yellow for phase, Black for neutral and Green for earthing at all times.
All as per item No. 125.00 here-in-before but one 3 pin 5 amp switch socket out let independent .
All as per item No. 125.00 here in-before but for one 3 pin 5 amps socket outlet on the same board with other switch with PVC conduit complete 1.5 sqmm multistraded all as specified and directed by Engineer in-charge.
All as per item No. 125.00 here-in-before but using 2.5 Sqmm size stranded copper conductor cable for one 3 pin 16 Amp socket outlet point on independent board complete PVC insulated and sheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified and directed by Engineer-in-Charge.
All as per item No. 125.00 here in before but using 4 sqmm for AC starters point wiring as specified and directed by engineer in charge.
M&L for point wiring for one light controlled by 2 way switch with 1100V grade FRLSH PVC insulated sheathed multistranded copper conductor cable conforming to IS : 694 of size 1.5 Sqmm two runs single core for phase and neutral drawn through in and including PVC concealed conduit of suitable size (minimum 20mm dia medium grade ISI Marked) complete with one run of 1100V grade FRLSH PVC insulated multistranded copper conductor cable 1.5 Sq mm single core green colour for earth continuity conductor and connecting to common earth dolly incl provn of modular type galvanized MS sheet pressed sunken box not less than 1.00 mm thick concealed on wall including fixing of modular cover plate of suitable modules with fixing screws, for fixing of modular type switches etc. complete including cutting chases making good of disturbed surfaces of wall/ceiling/floor in same specification as per existing surrounding surface complete all as specified and directed. Note : Proper colour code of wiring to be maintained.
S & F switch piano flush type 2 way for 10 watt led in stairs complete all as directed and specified.
S&F switch piano flush type, single pole one way, 6 Amp complete all as specified and as directed.
Supply & fix switch socket combination multi - purpose 3 pin, 5 &15 amp controlled by one switch flush type complete.
S&F socket out let 2 in 1 ,3 pin 5 Amps on the same board with other switch complete all as specified and directed by engineer incharge.
S&F switch socket combination 2 in 1 3pin switch socket outlet 5A on independent board complete all as specified and directed by Engineer- in-charge.
Supply and fix bell push switch, flush type 5 Amp complete all as specified and as directed.
S & F call bell, ding dong AC 230 volts,50Hz single pole complete all as specified and as directed.
S&F ceiling rose, surface bakelite, 65 x 50 mm,three terminals complete all as specified and directed.
S&F ceiling fan regulator electronic Step type, solid state, , 240 volts, complete all as specified and as directed.
S & F surface & wall mounted mirror light LED 2 feet with 1X10 watt LED tube light fittings indoor decorative luminaries with all necessary connection and fixing arrangements with the following specification:- (i) Housing- Extruded polycarbonate (ii) IP rating- IP 20 (iii) Front cover - Acrylic/ polycarbonate cover (iv) Mounting - Suitable for wall/ Ceiling Mounting (v) Finish- Smooth Finish (vi) Lamp- high bright LED (vii) LED efficacy (Lm/Watt) - Not less than 120 Lm/Watts (viii) Colour Temperature- Not less than 5700K (ix) Colour Rendering Index (CRI)- Not less than 80 (x) Life- Not less than 25000 hours of operation (xi) Optics- designed for optimum light distribution (xii) Control Gear - Inbuilt Electronic driver with APFC PF not less than 0.95 and THD not more than 20% of the standard operating voltage 180-270V AC 50 Hz (xiii) Surge protection- Inbuilt surge protection of minimum 2 KV (xiv) aluminium heat sink- As per OEM's Design (xv) Bidder has to compulsorily submit the LM-79 and LM-80 NABL accredited lab test report for the offered LED has to be structured in the sequence.
S & F surface & wall mounted LED 2 feet with 1X10 watt LED tube light fittings indoor decorative luminaries with all necessary connection and fixing arrangements with the following specification:- (i) Housing- Extruded polycarbonate (ii) IP rating- IP 20 (iii) Front cover - Acrylic/ polycarbonate cover (iv) Mounting - Suitable for wall/ Ceiling Mounting (v) Finish- Smooth Finish (vi) Lamp- high bright LED (vii) LED efficacy (Lm/Watt) - Not less than 120 Lm/Watts (viii) Colour Temperature- Not less than 5700K (ix) Colour Rendering Index (CRI)- Not less than 80 (x) Life- Not less than 25000 hours of operation (xi) Optics- designed for optimum light distribution (xii) Control Gear - Inbuilt Electronic driver with APFC PF not less than 0.95 and THD not more than 20% of the standard operating voltage 180-270V AC 50 Hz (xiii) Surge protection- Inbuilt surge protection of minimum 2 KV (xiv) aluminium heat sink- As per OEM's Design (xv) Bidder has to compulsorily submit the LM-79 and LM-80 NABL accredited lab test report for the offered LED has to be structured in the sequence.
S & F surface & wall mounted LED 4 feet with 1X20 watt LED tube light fittings indoor decorative luminaries with all necessary connection and fixing arrangements with the following specification:- (i) Housing- Extruded polycarbonate (ii) IP rating- IP 20 (iii) Front cover - Acrylic/ polycarbonate cover (iv) Mounting - Suitable for wall/ Ceiling Mounting (v) Finish- Smooth Finish (vi) Lamp- high bright LED (vii) LED efficacy (Lm/Watt) - Not less than 120 Lm/Watts (viii) Colour Temperature- Not less than 5700K (ix) Colour Rendering Index (CRI)- Not less than 80 (x) Life- Not less than 25000 hours of operation (xi) Optics- designed for optimum light distribution (xii) Control Gear - Inbuilt Electronic driver with APFC PF not less than 0.95 and THD not more than 20% of the standard operating voltage 180-270V AC 50 Hz (xiii) Surge protection- Inbuilt surge protection of minimum 2 KV (xiv) aluminium heat sink- As per OEM's Design (xv) Bidder has to compulsorily submit the LM-79 and LM-80 NABL accredited lab test report for the offered LED has to be structured in the sequence.
Supply and fixing LED fittings with lamps of 35 watts for bldg security light IP 66 power Coated pressure die cast aluminium compact high power LED street lightcomplete all as specified and as directed.
Supply and fixing sub main wiring with two run of single core 6 Sqmm PVC insulated unsheathed stranded cable copper conductor drawn through PVC conduits Concealed in walls, ceiling etc with all fittings and accessories of PVC conduits (like Tee, bend etc.) complete fixed to walls/ceiling etc than 25 mm dia with all fittings including 6 sq mm PVC insulated unsheathed single core copper conductor as earth wire and including PVC conduit all as specified and as directed. Note : (i) Two run of single core cable 6 sq mm and one run earth wire 6 sq mm will be measured as one length.
Supply and fixing sub main wiring with two run of single core 4 Sqmm PVC insulated unsheathed stranded cable copper conductor drawn through PVC conduits Concealed in walls, ceiling etc with all fittings and accessories of PVC conduits (like Tee, bend etc.) complete fixed to walls/ceiling etc with all fittings including 4 sq mm PVC insulated unsheathed single core copper conductor as earth wire and including PVC conduit all as specified and as directed. Note : (i) Two run of single core cable 4 sq mm and one run earth wire 4 sq mm will be measured as one length.
Taking down unserviceable sub main wiring any size including conduit/ casing caping and making good to the disturbed surface complete all as specified and directed.
Taking down unserviceable rusted / damaged MCB DBs of any type and way along with any type MCB and keeping serviceable MCB in safe custody in re-use in the work or depositing to MES store and making good to the distubed surfaces of walls etc. complete all as specified and as directed.
Supply and fixing sheet metal double door enclosure for DB's when MCBs to be used 8 way single pole and neutral double door with 200 amps rated bus bar complete including connection all as specified and directed.
Supply and fixing sheet metal double door enclosure for DB's when MCBs to be used 4 way single pole and neutral double door with 200 amps rated bus bar complete including connection all as specified and directed.
Supply and fixing MCB 6 to 32 Amps, SP, 240 Volts ,C- Curve breaking capacity 10 KA as directed by the Engr-in-Charge
Supply and fixing MCB 32 Amps, DP 240 Volts ,C- Curve breaking capacity 10 KA as directed by the Engr-in-Charge.
Supply and fixing MCB TPN DB made up with sheet metal double door, phosphorised, power coated, neutral link, earth bar and din rail, 6 way TPN with 200 amps rated bus bar, 415 volts complete all as specified and as directed.
Supply and fixing MCB TPN 63 Amps, 415 Volts ,B- Curve breaking capacity 10 KA all as directed by the Engr-in-Charge.
Taking down fans,opening the blades and keeping its in safe coustody and refixing the ceiling fan upto 1400mm Sweep later at its own position complete all as directed by Engineer-in-Charge.
Materials and labour for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, pre-cast RCC (1:2:4) type B-1 normal mix of size 540 x 540 x 50 mm thick cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed.
Supply and fixing of Bulb holder angular PVC/Polycarbonate suitable for batten fittings complete all as specified & directed.
S & F LED bulb 9 Watts 240Volts 50 hz in bulb holder having luminous Efficacy of minimun 110 Lm/ Watts and life of atleast 15000 Hours with in built surge protection of Minimum 2 KV ,opearting temperature of 0 C to 35 C , colour rendering index of 80 , colour temoerature of Min 6000K with start up time less than 2seconds, voltage withstand range of 140V- 270V complete all as directed.
Taking down exhaust fan 200 mm to 300 mm sweep of any make sealing cable ends, dismantling blades , refixing the same in original position including provision of cable from ceiling rose or connector to fan, complete all as specified and as directed by Engr In Charge.
Supply and fix A C starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amps plug top complete all as directed.
Taking down carefully electric geyser any type any size and refixing in original position complete all as directed.
Material and labour for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised iron strip of 25x4 mm dia as earthing lead by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 15 mm bore (light grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1(using 20 mm graded aggregate) and pre-cast RCC (1:2:4) type B-1 normal mix of size 540 x 540 x 50 mm thick, reinforced with 8 mm dia TMT bars both ways and one handle for lifting made with 10 mm dia mild steel bar,funnel, wire mesh 20 mm bore galvanised (light grade) for watering, charcoal and salt in alternate layers including necessary execuation and eath works in any types of soil complete all as shown on Electrical plate No 3 of MES SSR-I including taking out the old earthing material complete all as specified and directed.
Supply and fixing of air termination single pointed aluminium rod of size 12 mm dia and 300 mm long along with GI pipe complete all as specified and as directed.
Supply and fixing of test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex head screw complete all as specified and as directed.
Supply & fixing of aluminium strip 20x3.15 mm in proper position saddles on porcelain insulator and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed.
Taking down old U/s GI strip of any size and making good surfaces all complete as specified and directed by Engg-in-charge
Taking down old U/s Aluminium strip of any size and making good surfaces all complete as specified and directed by Engg-in-charge.
S&F single galvanised strip of size 25x4mm galvanised iron in proper position saddles on porcelain insulator and fixing screws for roof conductor from top to the bldg ring point ot the test point of the bldg as required all as specified and directed.
NIRMAL SALES CORPORATION (BID ID -3253642)
SHREE KRISHNA INFRASTRUCTURE (BID ID -3253950)
BALAJI MATRIX HOLDINGS (BID ID -3253607)
surendra infrastructure pvt ltd (BID ID -3253718)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ.xls
BOQ • 0.51 MB
Tenderdocument.pdf
Tender Documents • 1.61 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .