| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC N S T COLONY CIRCULAR ROAD HOUSE NO 04 DMC DIMAPUR 797 112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹11.0 L+₹90,710.10 (8.96%)Rejected-Finance NEAR RAM JANAKI HIGHER SECONDARY SCHOOL H NO 03 THAKURBAR DIMAPUR NAGALAND 797112 | DIMAPUR | DIMAPUR | NAGALAND | 797112 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹11.2 L+₹1.1 L (10.4%)Rejected-Finance BR GADGIL ROAD PUNE MAHARASHTRA 411030 INDIA | PUNE | MAHARASHTRA | 411030 | L3 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹18,520
Closing Date
13 Feb 2021, 6:00 pmClosed
AGE I ZAKHAMA
AGE (I) Zakhama C/o 792 FPO PIN-900792 C/O 99 APO
SPECIAL REPAIRS TO BLDG NO T-368, T-369 AND T-692 AT ZAKHAMA MILITARY STATION
2021_MES_415527_1
8897 SPR ZMS
Open Tender
Civil Works
Item Rate
180 days
ZAKHAMA
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
AGE I Zakhama
₹18,520
Yes
29 Jun 2021
23 Jan 2021
15 Feb 2021
23 Jan 2021
13 Feb 2021
30 Jan 2021
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) and removal of debris out of MD land at the location decided by the Engineer-in-charge complete all as specified and as directed.
Dismantling timber scantling 40 Sqcm and over in section, unframed work in any position,complete all as specified and as directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including similar pattern roof covering.complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets.complete all as specified and as directed.
Taking down shutters of any description exc 1 sq.m and n exc 2 sq.m each, complete all as specified and as directed.
Taking down shutters of any description n.exc 1 Sqm each.complete all as specified and as directed.
Taking down cement plaster on brick, concrete or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and removal of rubbish out side MD land at the location decided by the Engineer-in-charge complete all as specified and as directed.
M& L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in Cement Mortar (1:4) and even and smooth without using extra cement including mixing of water proofing compound wherever required .complete all as specified and directed. Note :WPC shall be measured & paid seprately.
M&L rendering 15mm thick on fair faces of brick work or concrete surfaces in Cement Mortar (1 :6) and finishing even and smooth without using extra cement. complete all as specified and directed.
Supply only water proofing compound ISI Marked, complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B-0 using(12.5mm graded stone aggregate) as in flooring for level course, complete all as specified and directed.
M&L for 15mm thick screed bed or bedding layer of cement mortar (1:4) for laying under floor finishes,complete all as specified and directed.
M&L for joint free Non skid ceramic tiles 7 to 8 mm thick (square/rectangular ) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles.complete all as specified and directed.
All as per Item No 13 above hereinbefore but in skirting including necessary cutting of tiles.
M&L for second class hardwood as in scantlings clean sawn timber framed and fixed. complete all as specified and directed.
M&L for 4mm thick plywood, grade BWR,type BB, fixed with nails to timber frame work as in walls, complete all as specified and directed.
M&L for 4mm thick plywood, grade BWR,type BB, fixed with nails to timber frame work as in ceiling, complete all as specified and directed.
S&F 0.63 mm thick Galvanized, corrugated mild steel sheeting with two corrugations side lap, fixed with L-type /J-typer or cranked hook bolts and washers, in roofs, etc with zinc coating 275 grade ,complete all as specified and directed.
Labour only for refixing 0.63 mm thick Galvanized, corrugated mild steel sheeting with two corrugations side lap, fixed with L-type , J-typer or cranked hook bolts and washers, in roofs, etc ,complete all as specified and directed. Note :New L-type/J-typer or cranked hook bolts and washers required shall deemed to be includede in quoted rates
S&F 0.63mm thick plain galvanised, mild steel sheeting, in stepped flashing (measured as the minimum rectangle from which the pieces can be cut) etc and fixed with nail complete all as specified and directed.
Labour only for refixing 0.63mm thick plain galvanised, mild steel sheeting, in stepped flashing (measured as the minimum rectangle from which the pieces can be cut) complete with grade of zince coating 275. fixed with nail complete all as specified and directed.Note :Nails (length and girth as fixed) required shall deemed to be includede in quoted rates
M&L for 20mm to 25mm thick IInd class HW weathering boarding, wrought both sides and edges shot and chamfered ( on exposed edges) , rebated on thick edge to give 20mm laps. complete all as specified and directed
S&F mild steel wind tie bar for roof including securing nuts bolts and washers conforming to Fe.290 Gde- E-165.complete all as specified and directed
S&F 30 mm thick Flush shutters, solid core construction, with particle board core and and plywood face panels, commercial type on both sides with lipping/frame to match, complete all as specified and as directed.
S&F 35mm thick II nd class hardwood panelled shutters (any number of panels) with panels of timber flat on both sides (feather edged) or of vennered particle board medium density, wood particle board with commercial face veneers.complete all as specified and directed
All as above as in windows shutters 30mm thick divided into squares, with plain, chamfered or rounded , mitred or rebated sash bars with stiles and rails as specified in SSR part I section 8 clause 8.24 (b) . complete all as specified and directed
S & F as in replacement mild steel galvanized iron wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 and fixed with tinned tacks or staples complete all as specified and as directed.
Hacking out old broken glass ( any thickness,size,quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads. Complete all as specified and directed.
M&L for 3mm sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm each pane. Complete all as specified and directed.
M&L for 100 mm long Butt hinges med weight cold rolled mild steel and fixed.Complete all as specified and directed.
M&L 75mm long Butt hinges med weight cold rolled mild steel and fixed, Complete all as specified and directed.
S&F 150 mm long Aluminium anodised barrel tower bolt of extruded section and fixed. Complete all as specified and directed.
S&F 100mm long Aluminium anodised barrel tower bolt of extruded section and fixed. Complete all as specified and directed.
S& F 150mm long extruded aluminium alloy handles, fabricated type, anodised and fixed. Complete all as specified and directed.
S & F 100 mm long extruded aluminium alloy handles, fabricated type, anodised and fixed, Complete all as specified and directed.
S& F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp staple (Bolt type) and fixing clips of sheet, cast or extruded section or cast aluminium alloy and fixed. Complete all as specified and directed.
S&F in repairs 300mm long mild steel, ordinary rat tail rod pattern springs including roller and roller plate, Complete all as specified and directed.
S & F 140mm long floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring fixed in floor, Complete all as specified and directed.
S&F 2nd class hardwood small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all neacessary' labours ; articles nexc 200 cu.cm each.Complete all as specified and directed.
M&L in repairs. for Prelaminated Particle Board 18/19 mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancig white lamination, fixed with nails for pelmet boxes, complete all as specified and directed.
S & F in repairs 20mm dia mild steel chromium plated curtain rods with and including fixing socket complete all as specified and as directed.
M&L for preparation of old wooden surfaces and wood based materials of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new wooden surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.complete all as specified and directed
M&L for preparation of new painted surfaces of steel and iron work of any description over 10 cmwidth or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of redoxide on new surfaces in any tint complete all as specified and directed.
M&L for preparation of old painted surfaces of steel and iron work of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paiint complete all as specified and directed.
M&L for preparation new plastered surfaces of walls and applying two coats of oil distemper over coat of primer, complete all as specified and directed.
M&L for preparation new plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant paint complete all as specified and directed.
M & L for 75 mm thick cement concrete (1:3:6) type C-2, using 40mm graded stone aggregates as in sub base even.complete all as specified and directed.
M& L for provinding cement concreter type C1(1:3:6) using 20mm stone aggregate as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directing. complete all as specified and directed.
Extra for forming fair finished drain or channel 20 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc.complete all as specified and directed.
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes .complete all as specified and as directed.
M&L for point wiring with single core PVC insulated unsheathed multistranded copper conductor FRLS cable of size 1.5 Sqmm nominal area 1100 volt grade drawn through and including PVC casing-capping/conduit of suitable size with all fittings and accessories including PVC board with cover of suitable size for housing/mounting the switches/socket etc including 1.5 Sqmm PVC insulated unsheathed single core copper conductor as earth continuty wire connected to common earth dolly for one light/exhaust fan point control by one switch.one way compleate all as specified and directed.
All as per item No 52 here- in- above but with stranded copper conductor 2.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed multistranded FRLS cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amp socket outlet, independent, including PVC insulated multistranded FRLS copper conductor 2.5 Sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly.
All as per item No 52 above but for 3 pin, 5 Amp Socket on the same board.
All as per item No 52 above but for 3 pin,5 Amp Socket on independent board
S&F switch piano flush button single pole one way 5 Amp.complete all as specified and as directed.
S&F switch socket combination 2 in 1, 3 pin 05 Amp flush type universal. complete all as specified and as directed.
S&F switch socket combination 5 Pin, 16 Amp flush type.complete all as specified and as directed.
S&F ceiling rose surface back light 65 x 25mm, two to three terminal.complete all as specified and as directed.
M&L Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F LED lamps 10W, LM 80 tested LED technology,Wide voltage range 150-300VAC complete all as specified and as directed. Make -Wipro or eqvt make of philips, bajaj, Havells
Taking down old unserviceable light fitting of any type any rating and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes .complete all as specified and as directed.
S&F LED T/L 20 W, Fixture size (1150x25x40) mm (for 20 W), complete with batten and luminaries and as per the technical spevifications given below . Note:LED used shall conform to IS- 16103: 2012 &IS-16101:2012 should be of SMD type only. ii. LED efficiency shall be greater than 100 lumens per Watt/ max latest efficacy available. iii. Colour rendering index (CRI: Greater than or equal to 70). iv. Min efficiency of driver: 85%. v. Power factor of complete fitting: Greater than 0.95. vi. Input Operating Voltage: 140 V to 277V AC. vii. In-built high and low voltage cut-offs: 140 V Low and 277 (high). viii. Short circuit, Over load protection. ix. Housing of luminaries: Pressure die-cast aluminum LM6/ADC 12/LM 24housing
Taking down old unserviceable DB/Main switchs incl MCBs wooden block of any size and type and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes .complete all as specified and as directed.
S&F PVC rectangular block of size 250x200x50mm depth, complete all as specified and as directed.
S&F sheet metal enclosure for DB when MCB to be used 8 way 200 amp rated bus bar, SPN 240V, double door complete all as specified and directed..
S&F MCB Single pole and neutral 240 Volts, 6-32. Amps, 10 A,C-series,complete all as specified and directed. Make -havells, cat No.DHMGCSNF006-032 or same as equivalent.
S&F MCB Single pole 240 Volts, 6-32. Amps, 10 A,C-series, complete all as specified and directed.Make -havells, cat DHMGCSPF006-032 or same as equivalent.
Taking down the existing unserviceable sub main wiring/Under ground cable of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes .complete all as specified and as directed.
S&F 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor surved with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire, one twin core cable flat or rouind or 10 sq mm cable.
M&L Exaust fan 300mm sweep domestic (Metal) complete incl making hole in ply wood wall with framing and making good disturbed surface as existing matching to wall complete all as specified and directed Make-Havells or equivqlent and all as specified.
SHRIi Bachulal shah
M/S RAHUL TRADING CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .