GEMC-511687794884297
Awarded to SPI ENGINEERS PVT LTD
₹4.8 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| FLUKE-TI450 PRO, INFRARED THERMAL CAMERA | FLUKE-TI450 PRO, INFRARED THERMAL CAMERA | - | 1 NOS | ₹4.8 L | 481,500 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.8 LQualified Make: FLUKE
Model: FLUKE-TI450 PRO, INFRARED THERMAL CAMERA 506 701 SIDDARTH BUILDING 96 NEHRU PLACE NEW DELHI 110019 | NEW DELHI | NEW DELHI | DELHI | 110019 | Make: FLUKE
Model: FLUKE-TI450 PRO, INFRARED THERMAL CAMERA | L1 | Qualified | |
| 2 | L2₹6.9 L+₹2.1 L (43.4%)Qualified Make: FLUKE
Model: FLUKE-TI450 PRO, INFRARED THERMAL CAMERA A 8 MANGALDIP APPARTMENT SAIJPUR BOGHA NARODA ROAD AHMEDABAD GUJARAT 382345 | AHMADABAD | GUJARAT | 382345 | Make: FLUKE
Model: FLUKE-TI450 PRO, INFRARED THERMAL CAMERA | L2 | Qualified | |
| 3 | Disqualified Make: Flir
Model: FLIR E75 E 366 2ND FLOOR NIRMAN VIHAR VIKAS MARG VIKAS MARG VIKAS MARG NEW DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: Flir
Model: FLIR E75 | - | Disqualified | |
| 4 | Disqualified Make: Testo
Model: 875 2i set Testo | Make: Testo
Model: 875 2i set Testo | - | Disqualified | |
| 5 | Disqualified Make: FLUKE
Model: FLUKE-TIS75, THERMAL IMAGER 7 MB 250 I G NAGAR JAIPUR JAIPUR JAIPUR CITY SOUTH RAJASTHAN 302025 | 302025 | Make: FLUKE
Model: FLUKE-TIS75, THERMAL IMAGER | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
23 Aug 2018, 5:00 pmClosed
thermal imager Thermal Imager ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values PERFORMANCE FEATURES Type Hand held - Detector Resolution (minimum) (pixel) 75000 75000 Temperature Range of Objects (Degree Celsius) -20 to +500 -20 to +250
20 to +350
20 to +500
+30 to +42 (for fever measurment & animal husbandry thermal imager) Temperature measuring accuracy of reading (or better) ± 2% oC ± 2% oC Minimum Focus distance 10 10.0 Image capture frequency/frame rate (Hz) N ≥ 9 - Image Detector Type Focal Plane Array (FPA) Uncooled Micro bolometer (for fever measurment & animal husbandry thermal imager) - Thermal sensitivity (NETD) 0.05 1/5 User selectable Emissivity setting/correction Between 0.01 and 1 - Infrared spectral band (micrometer) Between 8 and 14 - Image Palettes 9 - LENS MEASUREMENTS FEATURES Horizontal Field of View of Standard lens (degree) 20-25 - Vertical Field of View of Standard lens 14-20 - Horizental Field of View of Telephoto lens NA 9-12
13-15
15-20
20-25
NA Vertical Field of View of Telephoto lens NA 7-12
15-21
20-26
NA IFOV of Standard lens (mRad) 2.1 - IFOV of Telephoto Lens (mRad) NA 0.5
0.65
0.7
0.75
0.87
1
NA IFOV of (Spatial resolution) (mRad) 1.31 - DISPLAY Display Type Color LCD Color LCD
Color LED Display size 3.5 GENERAL FEATURES Image capture
review and save mechanism One handed image capture
review and save capability - Storage medium Mini SD card
SD Memory card
USB stick - Size of USB stick 8 - File formats JPEG
BMP
GIF
PNG
TIFF - Built-in digital camera/Visual Camera Resolution (Mpixel) N ≥ 1 N ≥ 0.5
N ≥ 1
NA Details of Operating functions SINGLE HANDED THERMAL IMAGER - Facility for the adjustment/selection of the time/date etc yes - Interface for image transfer Mini SD card
USB stick storage medium
WiFi
USB Cable with suitable drivers for downloading - 2/5 to PC Focus Manual & Auto - other features - - OPERATING CONDITION Minimum Operating Temperature -10 - Maximum Operating Temperature 50 - Operating Humidity (RH) 95 - POWER REQUIREMENT Power Requirements Battery Operated - chemistry of the battery lithium ion - Voltage of rechargeable Battery 12 - Capacity of rechargeable battery (milliAH) 3500 - Suitable charger/adapter provided yes - Battery Backup 4 - Power Management Automatic shut down User Selectable - On-screen battery level indicator yes - CERTIFICATION & SAFETY IP Protection IP54 - Safety certification UL
CE - GENERIC Size/dimension 27.7cm x 12.2 cm x 16.7 cm - Weight (including batteries) 1.04 - Automatic active temperature stabilization system of camera yes - Provision for through- the-lens direct temperature measurement capability yes - TEST REPORT DETAILS & TESTS The equipment supplied with calibration certificate yes - conformity to Dry Heat for 16 hrs at a maximum temp in true - 3/5 accordance with IS:900 0/part-3/section-5/1977 latest conformity to Cold Test for 4 hrs at a minimum temp in accordance with IS:9000/part-2/sec tion-4/1977 latest true - conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH true - Availability of the test report from Central Govt/NABL/ILAC accredited lab to prove conformity to the specification true - Test Report Number and date for the specification test (not a part of biddable parameter) - - Name and address of the Lab for the specification test (not a part of biddable parameter) - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Bijoy Kumar Kuanr 110067
SCNS Building
JNU New Campus 1 15
471619
GEM/2018/B/66666
GeM Contract
thermal imager
GeM Contract
15 days
Delhi; New Delhi
PRODUCT
Awarded to SPI ENGINEERS PVT LTD
₹4.8 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| FLUKE-TI450 PRO, INFRARED THERMAL CAMERA | FLUKE-TI450 PRO, INFRARED THERMAL CAMERA | - | 1 NOS | ₹4.8 L | 481,500 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| thermal imager Thermal Imager ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values PERFORMANCE FEATURES Type Hand held - Detector Resolution (minimum) (pixel) 75000 75000 Temperature Range of Objects (Degree Celsius) -20 to +500 -20 to +250 | - | - | - |
| 20 to +350 | - | - | - |
| 20 to +500 | - | - | - |
| +30 to +42 (for fever measurment & animal husbandry thermal imager) Temperature measuring accuracy of reading (or better) ± 2% oC ± 2% oC Minimum Focus distance 10 10.0 Image capture frequency/frame rate (Hz) N ≥ 9 - Image Detector Type Focal Plane Array (FPA) Uncooled Micro bolometer (for fever measurment & animal husbandry thermal imager) - Thermal sensitivity (NETD) 0.05 1/5 User selectable Emissivity setting/correction Between 0.01 and 1 - Infrared spectral band (micrometer) Between 8 and 14 - Image Palettes 9 - LENS MEASUREMENTS FEATURES Horizontal Field of View of Standard lens (degree) 20-25 - Vertical Field of View of Standard lens 14-20 - Horizental Field of View of Telephoto lens NA 9-12 | - | - | - |
| 13-15 | - | - | - |
| 15-20 | - | - | - |
| 20-25 | - | - | - |
| NA Vertical Field of View of Telephoto lens NA 7-12 | - | - | - |
| 15-21 | - | - | - |
| 20-26 | - | - | - |
| NA IFOV of Standard lens (mRad) 2.1 - IFOV of Telephoto Lens (mRad) NA 0.5 | - | - | - |
| 0.65 | - | - | - |
| 0.7 | - | - | - |
| 0.75 | - | - | - |
| 0.87 | - | - | - |
| 1 | - | - | - |
| NA IFOV of (Spatial resolution) (mRad) 1.31 - DISPLAY Display Type Color LCD Color LCD | - | - | - |
| Color LED Display size 3.5 GENERAL FEATURES Image capture | - | - | - |
| review and save mechanism One handed image capture | - | - | - |
| review and save capability - Storage medium Mini SD card | - | - | - |
| SD Memory card | - | - | - |
| USB stick - Size of USB stick 8 - File formats JPEG | - | - | - |
| BMP | - | - | - |
| GIF | - | - | - |
| PNG | - | - | - |
| TIFF - Built-in digital camera/Visual Camera Resolution (Mpixel) N ≥ 1 N ≥ 0.5 | - | - | - |
| N ≥ 1 | - | - | - |
| NA Details of Operating functions SINGLE HANDED THERMAL IMAGER - Facility for the adjustment/selection of the time/date etc yes - Interface for image transfer Mini SD card | - | - | - |
| USB stick storage medium | - | - | - |
| WiFi | - | - | - |
| USB Cable with suitable drivers for downloading - 2/5 to PC Focus Manual & Auto - other features - - OPERATING CONDITION Minimum Operating Temperature -10 - Maximum Operating Temperature 50 - Operating Humidity (RH) 95 - POWER REQUIREMENT Power Requirements Battery Operated - chemistry of the battery lithium ion - Voltage of rechargeable Battery 12 - Capacity of rechargeable battery (milliAH) 3500 - Suitable charger/adapter provided yes - Battery Backup 4 - Power Management Automatic shut down User Selectable - On-screen battery level indicator yes - CERTIFICATION & SAFETY IP Protection IP54 - Safety certification UL | - | - | - |
| CE - GENERIC Size/dimension 27.7cm x 12.2 cm x 16.7 cm - Weight (including batteries) 1.04 - Automatic active temperature stabilization system of camera yes - Provision for through- the-lens direct temperature measurement capability yes - TEST REPORT DETAILS & TESTS The equipment supplied with calibration certificate yes - conformity to Dry Heat for 16 hrs at a maximum temp in true - 3/5 accordance with IS:900 0/part-3/section-5/1977 latest conformity to Cold Test for 4 hrs at a minimum temp in accordance with IS:9000/part-2/sec tion-4/1977 latest true - conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH true - Availability of the test report from Central Govt/NABL/ILAC accredited lab to prove conformity to the specification true - Test Report Number and date for the specification test (not a part of biddable parameter) - - Name and address of the Lab for the specification test (not a part of biddable parameter) - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Bijoy Kumar Kuanr 110067 | - | - | - |
| SCNS Building | - | - | - |
| JNU New Campus 1 15 | - | - | - |
Exempted
31 Aug 2018
13 Aug 2018
contract_GEMC-511687794884297.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_471619.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .