Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAdmitted-Finance | ₹2.0 L | L1 | Admitted-Finance |
| 2 | L2₹2.1 LAdmitted-Finance | ₹2.1 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | IMPLA GENERAL SUPPLIERS L1 | Heaven Electricals L2 |
|---|---|---|---|---|---|
| 1.00Work items identified; | |||||
| 1.01 | Dismantelling of 63 KVA existing transformer and transportation of same to Divsional workshop complete in all respect as per Standards. | 1 | No. | 2,000 ₹2,000 | 5,000 ₹5,000 |
| 2.01 | Supply, installation, testing and commisioning of 100 kVA ,11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound , and with LV
Cable Box having detachable Aluminium Gland plate 11/0.433KV, 3-phase(EE Level-II) complete in all respect as per Standards. | 1 | No. | 1,60,000 ₹1.6 L | 1,58,000 ₹1.6 L |
| 3.01 | Supply,Carraige upto site, fixing and installation of GI Channels of different sizes including clamps and braces. | 50 | Kg | 120 ₹6,000 | 120 ₹6,000 |
| 4.01 | Supply,Carraige upto site,Installation,testing and Commissioning of 11kV Polymeric composite Pin Insulators 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance
320mm complete in all respects as per standards. | 3 | No. | 175 ₹525 | 200 ₹600 |
| 5.01 | Supply, Carraige upto site, installation, testing and Commissioning of Gapless Surge Arrestor 9 kV, 10 kA, LA with polymer housing, Stn. Type complete in all respects as per standards. | 1 | Set | 1,500 ₹1,500 | 4,000 ₹4,000 |
| 6.01 | Supply, Carraige upto site, installation, testing and Commissioning of 11 kV G.O AB Switch 3-phase, 3 pole 200-Amp, vertical Type with fittings complete in all respects as per standards. | 1 | Set | 8,000 ₹8,000 | 10,500 ₹10,500 |
| 7.01 | Supply, Carraige upto site, installation, testing and Commissioning of LT Temporary fuse set as per KPDCL drawings complete in all respects as per standards. | 1 | No. | 2,000 ₹2,000 | 5,500 ₹5,500 |
| 8.01 | Supply, Carraige upto site, laying, stringing, tensioning, binding of 185mm² (1Ckt )1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type cable complete in all respects as per standards. | 44 | mtr | 250 ₹11,000 | 350 ₹15,400 |
| 9.01 | Supply,Carraige upto site, fixing of Aluminium Thimbles of size 185 Sqmm. | 12 | No. | 35 ₹420 | 40 ₹480 |
Tender Value
₹2.4 L
EMD Value
₹4,820
Closing Date
24 Jan 2026, 2:00 pmClosed
Executive Engineer ED Budgam KPDCL
ED Budgam, KPDCL
Augmentation of 63 KVA Substation to 100 KVA at Ahanger Mohalla Lalpora.
2026_PDD_300728_1
EDB/110 of 2025-26
Open Tender
Electrical and Maintenance Works
30 days
ED Budgam, KPDCL
AS PER SBD
7 documents required · 7 mandatory
₹200
Executive Engineer ED Budgam KPDCL
₹4,820
27 Jan 2026
15 Jan 2026
24 Jan 2026
15 Jan 2026
24 Jan 2026
16 Jan 2026
15 Jan 2026 - 16 Jan 2026
Work items identified;
Dismantelling of 63 KVA existing transformer and transportation of same to Divsional workshop complete in all respect as per Standards.
Supply, installation, testing and commisioning of 100 kVA ,11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound , and with LV Cable Box having detachable Aluminium Gland plate 11/0.433KV, 3-phase(EE Level-II) complete in all respect as per Standards.
Supply,Carraige upto site, fixing and installation of GI Channels of different sizes including clamps and braces.
Supply,Carraige upto site,Installation,testing and Commissioning of 11kV Polymeric composite Pin Insulators 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm complete in all respects as per standards.
Supply, Carraige upto site, installation, testing and Commissioning of Gapless Surge Arrestor 9 kV, 10 kA, LA with polymer housing, Stn. Type complete in all respects as per standards.
Supply, Carraige upto site, installation, testing and Commissioning of 11 kV G.O AB Switch 3-phase, 3 pole 200-Amp, vertical Type with fittings complete in all respects as per standards.
Supply, Carraige upto site, installation, testing and Commissioning of LT Temporary fuse set as per KPDCL drawings complete in all respects as per standards.
Supply, Carraige upto site, laying, stringing, tensioning, binding of 185mm² (1Ckt )1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type cable complete in all respects as per standards.
Supply,Carraige upto site, fixing of Aluminium Thimbles of size 185 Sqmm.
Supply,Carraige upto site, fixing and Commissioning of Aluminium Solderless Clamps of size 185 Sqmm.
Earthing of substation-Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 25 mmx3 mm, for connection of transformer body,G.O set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover complete in all respects as per standards.
Supply and fixing of GI barbed wire Anti climbind Device with clamps complete in all respects as per Standards
Paint Mark of Scheme
NOTE: 1.The rates quoted by the bidder for all the items shall be inclusive of GST/freight/insurance/storage/installation/testing and any other charges FOR Augmentation of 63 KVA Substation to 100KVA at Ahanger Mohalla Lalpora under the jurisdiction of ED Budgam, KPDCL..
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.65 MB
Tendernotice_2.pdf
PDF • 1.64 MB
BOQ_975450.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid