Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹48.0 L+₹1.7 L (3.67%)Rejected-AOC 3 C DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L2 | Rejected-AOC Being L2 | |
| 3 | L3₹49.4 L+₹3.1 L (6.70%)Rejected-Finance | L3 | Rejected-Finance BeingL3 |
Tender Value
Refer Docs
EMD Value
₹92,600
Closing Date
14 Aug 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, Bardhaman Electrical Division,
Purta Bhavan, 1st Floor, Purba Bardhaman
Electrical work for power back up supply at every establishment under Centre for Co operative Management ( C C M ) Barsul, Purba Bardhaman
2025_WBPWD_886257_1
WBPWD/EEBED/NIQ-15/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
Purba Bardhaman
Please refer Tender documents.
4 documents required · 4 mandatory
₹92,600
11 Dec 2025
1 Aug 2025
18 Aug 2025
1 Aug 2025
14 Aug 2025
1 Aug 2025
Amount
Supplying and fixing Sheet steel 32 A, 240 V Main Switches on ( 240 V DP with fuse on L & N ) flat iron frame on wall.(D-1/1a)( make - Standard / Havells / HPL )
Supplying and fixing Sheet steel 32 A, 415 V Main Switches on ( 415 V TP with fuse on L & N ) flat iron frame on wall.(D-1/1)( make - Standard / Havells / HPL )
Supplying and fixing 63 A, 415 V Sheet steel Main Switches on angle iron frame on wall.( D-1/b ) ( make- Standard / Havells / HPL )( For Computer Center)
Supplying and fixing 32 A Changeover switch with sheet ( 240 V DP) Steel enclosure on flat iron frame on wall with nuts,bolts etc.( D-1/2a ) ( make- Standard / Havells / HPL )
Supplying and fixing 63 A Changeover switch with Sheet( 240 V DP) Steel enclosure front handle operated on flat iron frame on wall with nuts bolts etc(D-1/2b)(make- Standard / Havells/ HPL )
Supplying and fixing Sheet steel enclouser front handle operated 100A , 415V TPN Main Switches with S & F 3 nos 100 A HRC fuses on angle iron frame on wall (D-4/b)(make-L&T/Havells/ Siemens/)
Supplying & fixing sheet metal (16 SWG) Iron Clad 415 V, 100/125 A ( Dimension of Cu. bars [450mm long] ,Size 4 x 15x3mm) (Dimension of Sheet Metal Box (600 x 500x150mm) Cu Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991)[D13-19.b]
Supplying and fixing 8 way double door Vertical TPN MCB Distribution board for isolator incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment ( upto 160A ) [ D-11/15 ] [Make LEGRAND/ABB ITUS/ Schneider]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, on wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [D9/13). [Make LEGRAND/ABB ITUS/ Schneider] a) (2+12 way)
Supplying and fixing 240 V, 40 A DP MCB Isolator on din rail of existing DBs and necessary connection.(D-5/6)[Make LEGRAND/ABB/ Schneider]
Supplying and fixing double door sheet steel (16SWG). powder coated cable end box for VTPN enclosure with IP- 42/43 protection, concealed in wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment (8 way) [D-12/16), [Make LEGRAND/ABB ITUS/ Schneider](For VTPN DB)
Supplying and fixing 415 V 100 A Four Pole Isolator of on din rail in existing DBs / enclosure and necessary connection(make-Legrand /Semiens) (D-5 /6)
Supplying and fixing 240/415 V , 32 A TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. [Make LEGRAND/ABB/ Schneider](D6/7)
Supplying and fixing 240/415 V(6-32 A) SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection for SPN / VTPN & HTPN Outgoing [Make LEGRAND/ABB ITUS/ Schneider](D-6/7)
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make:Polycab/RR kabel/Havells) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Make:Legrand Myrius/ABB IVIE/Crabtree Murano) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC (E-25 /4) ( PVC conduit on ceiling portion and remaining portion concealed ) (Avg. Run- 6 mtr)
(Avg. Run- 8 mtr)
Distribution wiringin1.1KVgrade 2x22/0.3 (1.5sqmm) single core stranded'FR' PVC insulated & unsheathed copper wire (Make:Polycab/RR kabel/Havells) partly in 20mmsize PVC rigid conduit 'FR' (Precision MMS make) [for horizontal run& above false ceiling portion only] and in19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5sqmm)single core stranded'FR' PVC insulated & unsheathed copper wire for ECC, tolight/fan/call bell points with Modular types switch (Make:Legrand Myrius/ABB IVIE/Crabtree Murano) fixed on Modular GI switch board complete with 2no.suitable size“Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish.[PVC Rigid Conduit only for horizontal run & above ceiling and vertical run concealed] (Avg. Run- 6 mtr) (E-25/5)
(Avg. Run- 8 mtr)
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make:Polycab/RR kabel/Havells) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S/F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Make:Legrand Myrius/ABB IVIE/Crabtree Murano) incl. S&F earth continuity wire fixed on G I Modular switch board with Modular top cover plate flushed in wall incl. mending good the damages as to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC .. on board ( E-24/3(a) )
Supplying and fixing PVC Rigid Conduit 'FR' [Make: Precision Medium] on wall, ceiling with saddles and other accessories as required and mending good damages to building works (E16/7) a. 20 mm size
b. 25 mm dia
Cutting channel of on masonry wall electric operated cutting machine incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works, a) 19 mm dia 3 mm thick polythene pipe without earth continuity wire in 40 mm X 40 mm channel (E3/6 a)
b) 25 mm dia 3 mm thick polythene pipe without earth continuity wire in 43 mm X 43 mm channel (E3/7 a)
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make:Polycab/RR kabel /Havells) of the following sizes in the prelaid polythene pipe/ Pvc rigid conduit and by the prelaid GI fish wire and making necy. connection as required.(E-9/1) 2 x 84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC ( MS to SPN) [E-9/1y]
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC.( SPN to power plug and Computer point) [E-9/1s]
3 x 22/0.3 (1.5 sqmm).(SPN to 2x 6A plug) [ E-9/1b]
4 x 50 sqmm ( From DG output panel to VTPN DB via Main switch ,changeover switch etc. ) (Non Schedule)
4x 80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC. (F-5/9) ( VTPN to change over swtich ) (E9/1d1)
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC( SPN to AC point) [E-9/1v]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes etc. 4x396/0.4 (50 sqmm) (F-5/8b/xvi)
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC. (F-5/9)
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC .(F-5/9)
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC( SPN to AC poin)
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC .(F-5/9)
3 x 22/0.3 (1.5 sqmm).(F-5/9)
Supplying & Fixing iron beam fan clamp of two piece type, as per approved specification, fabricated from 40 mm x 9 mm MS sheet flat suitable for beam having flange upto 150 mm wide – (As per Drawing no. 476 of PWD Specification Book – May 1991).[D-14/30]
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Make:Legrand Myrius/ABB IVIE/Crabtree Murano) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. As per GS. (E18/10)
Supply of 240V,1-Ph., 48" (1200mm) sweep, high speed AC ceiling fan, the capacitor of fan must be P-2 type brust proof & must have safety wire directly linked from fan hook to stator of fan. including safety wire and complete with all accessories like blades, canopy, fork, rubber bush, downrod etc. [Make :Crompton Aura Prime/Orient Quaser/Usha Striker PWD]Warranty atleast 02 years from final billing period.
Fixing ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. (C3/21a)
Supply & Fixing 240 V, 1 x 16 A + 1 x 6A, 5 pin Modular type plug socket (Make:Legrand Myrius/ABB IVIE/Crabtree Murano)with 16A & 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/1b, 3(a & b) & 4(a & b)]
Supply & Fixing 240 V, 1 x 16 A 3 pin Modular type plug socket (Make:Legrand Myrius/ABB IVIE/Crabtree Murano) without plug top on 2 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 1 x 16 A Modular type switch, on 2 Module GI Modular type switch board with top cover plate (Make:Legrand Myrius/ABB IVIE/Crabtree Murano) flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 3 nos. 6 A 3 pin Modular type plug socket & 1 no 16 A 5 pin Modular type plug socket with 3 nos. 6A and on1 no 16 A Modular type switch (Make:Legrand Myrius/ABB IVIE/Crabtree Murano) without plug top on 2 row 12 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(Computer point) [E-17 /1e, E-17 /4 a,b, & E-17 /3a,b]
Supply & Fixing 240 V, 2 nos 6 A, 3 pin Modular type plug socket (Make:Legrand Myrius/ABB IVIE/Crabtree Murano) with 2 nos 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17 /1b + E-17 /3a,b]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Make:Legrand Myrius/ABB IVIE/Crabtree Murano) without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. (AC point) [E-17/5a]
Supply & Fixing 240 V, 25 A, Modular type starter (Make:Legrand Myrius/ABB IVIE/Crabtree Murano)with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(AC Starter) As per GS. [E-19 /17 ]
Supply and delivery of Twin LED Fitting (2 X 18/20Watt 230VAC 50Hz, 4000K NW. THD<10%, built in 2.5KV SPD) with all accessories and 2 nos 18/20 Watt LED Tube(PC Body) 2100 lumen and Aluminium heat sink [Make: PHILIPS Cat No-TMC502 P 2 x TLED/CROMPTO/ Jaquar Warranty atleast 02 years from final billing period.
Supply and delivery of Single LED Fitting (1X 18/20Watt, 230VAC, 50Hz, 4000K NW. THD<10%, bult in 2.5KV SPD) with all accessories and 1 no 18/20 LED Tube(PC Body) 2100 lumen and Auminiuml heat sink. [Make: PHILIPS Cat No-TMC 502 P 2 x TLED,, CROMPTON/WIPRO/Jaquar. Warranty atleast 02 years from final billing period.
Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling with HW block and ceiling plates, nipples etc. as required as per direction of EIC( C-2/14d)
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length (C2/17)
Supply & delivery 300mm (12") 1420 r.p.m. sweep A.C. single phase heavy duty exhaust fan complete set ready to use x as per G.S. (Make - E.P.C Electrical Pvt. Ltd./USHA/ORIENT) Warranty atleast 02 years from final billing period.
Supply & delivery 225mm (9") 1370 r.p.m. sweep A.C. single phase heavy duty exhaust fan complete set ready to use x as per G.S. (Make - E.P.C Electrical Pvt. Ltd./USHA/ORIENT) Warranty atleast 02 years from final billing period.
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy, length of PVC Insulated wire and making connection for exhaust of following diameter: 30 cm (12") (C-4/28]
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy, length of PVC Insulated wire and making connection for exhaust of following diameter: 23 cm (9") (C-4/28]
Supply & Finishing louver shutter on wall with necy bolts & nuts (6 mm dia x 62 mm long)-For Al-30 cm Exhaust fan (12") [D- 14/32a]
Supply & Finishing louver shutter on wall with necy bolts & nuts (6 mm dia x 62 mm long)-For Al-23 cm Exhaust fan (9"[D- 14/32a]
Supply and fixing Gesto 6W Curve Shape Led Mirror Light-(Make Philips Gesto/Crompton/Havells)
Supply 230 V. 9 W pin type LED bulb (Philips, CG, Havells Make) for batten / angle batten holder.
Fixing only lamp on batten / angle batten holder (C2/11)
Supplying & Fixing Steel sheet metal waterproof hooded type looping cable box with hinged type rubber gascated door of size 250 x 200 x 100 mm deep having 16 SWG thick sheet with provision for fixing one no SP MCB & supply & fixing (1) One No 4 way 32 A capacity bakelite base terminal Block , one compression type brass cable gland for upto 4.core 16 sqmm cable and having lined with gasketted Gl top cover with brass machine screws etc, earthing terminal fixed on wall by means of flat iron frame including painting with anti corrosive paint.
Supply and fixing of 20/25 watt outdoor type LED fitting light fittings with 1 mtr long 32 mm dia pipe bracket fixed on wall by means of G I shaddle and screws incl connection . (Make:-CG -LSTS -20 -CDL NL-M or eqv Philips BRP029 LED25CW MR PSU Gr DX/ Jaquar)(Warranty at least 2 years from final billing period)
S / Fixing bulk head light fitting (Havells make) ceiling fitting on wall / ceiling by screws incl S/F 12 watt LED lamp complete set inc. connection etc. (D13/23)
Excavation of Soft soil for installation of Earth Electrode and filling & ramming. (G1/1a)
Earthing with ISI-Medium GI pipe 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: (G1/2)
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. (G2/4a)
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required – 40mm dia. (F6/11c)
Supply and delivery of 1.1 KV grade, 4 Core 10 sq mm. XLPE Insulated & Sheathed Armoured Aluminium Conductor cables. [Make: HAVELES/ POLYCAB/ RR KABLE/ Gloster]
Supply and delivery of 1.1 KV grade, 4 Core 35 sq mm. XLPE Insulated & Sheathed Armoured Aluminium Conductor cables. [Make: HAVELES/ POLYCAB/ RR KABLE/ Gloster]
Supply and delivery of 1.1 KV grade, 4 Core 16 sq mm. XLPE Insulated & Sheathed Armoured Aluminium Conductor cables. [Make: HAVELES/ POLYCAB/ RR KABLE/ Gloster]
Supply and delivery of 1.1 KV grade, 2 Core 10 sq mm. XLPE Insulated & Sheathed Armoured Aluminium Conductor cables. [Make: HAVELES/ POLYCAB/ RR KABLE/ Gloster]
Laying of one No. cable underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed [F-2/1 ] a) upto 35 sqmm
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc. with 1 X 10 swg G I wire
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. a) 4 core 35 sqmm [F-4/7c & F-5/8(b)
c) 4 core 16 sqmm [F-4/7(c) & F-5/8(b)
c) 2 core 10 sqmm [F-4/7(a) & F-5/8(b)
d) 4 core 10 sqmm [F-4/7(c) & F-5/8(b)
Supply and delivery 2 core 6 sq mm PVC insulated unmoured Aluminium cable from nearest pole to building pipe bracket by means of Catenary / Hanging manner with 1 X 8 SWG G I wire for strengthening support and binded by 9 SWG Soft Aluminium wire ( 2 nos binding in 1 mtr length ) incl connection. ( I 1 /2)
Supply and delivery 2 core 10 sq mm PVC insulated unmoured Aluminium cable from nearest pole to building pipe bracket by means of Catenary / Hanging manner with 1 X 8 SWG G I wire for strengthening support and binded by 9 SWG Soft Aluminium wire ( 2 nos binding in 1 mtr length ) incl connection. ( I 1 /2)
Supply and fixing 32 A 230 volt automatic change over switch double pole on flat iron frame on wall incl wire connections Make - Havells/ L&T/ Schneider)
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board(D13/20a)
Supply , delivery at site on foundation , commissioning of 58.5 KVA, 415V, 50Hz, 3Phase silent new DG Set, comprising of Engine, alternator, separate AMF panel, Base frame, Fuel tank, Battery, CPCB-IV approved Engine & Acoustic Enclosure having following specifications. ENGINE: Make : Cummins (Jakson)/Greaves Power/Ashok Leyland Engine Type : 4 Stroke Diesel Engine RPM : 1500 Rated Output : 74.4 ВНР or Higher Duty : PRIME Cooling : Liquid Cooled (EG Compleat 50:50) with radiator Cylinder : 4 Aspiration : Turbo Charged Type of Govemer : Electronic Fuel: HSD Fuel Tank Capacity : Minimum capacity 163 Ltrs. Fuel Consumption at 75% rated Load with Radiator or Fan : 13.6 Ltr./ Hr. or Less Fuel Consumption at 100% rated Load with Radiator or Fan : 16 Ltr./ Hr. or Less Overload Capacity : 10% overload for one hour for every 12 hours continuous running at full load or better Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, coolant temperature Indicator, RPM indicator and hour meter. Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Water Temp, warning/ Shutdown, Sensor failure Indicator, Engine over speed indicator, Battery charging and low battery indicator
Exhaust Silencer : Residential Type Starting system: 12V./ 24 V. starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard. Battery Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning Emission Norms : CPCB IV ALTERNATOR Make : Stamford/ Leroy Somer/Kirloskar/ABB /GE/ Alsthom/ Crompton Rating : 415 V., 3Ph. 50 Hz., 58.5 KVA, 1500 rpm, 47KW Type : Brushless, self excited and self regulated through on AVR Insulation : Class H Protection : Over/Under Voltage, Over/Under Frequency, Loss of AC sensing. Overspeed, Over Current, kW Overload Power Factor 0.8 Lagging , RPM 1500 Voltage Regulation (max) : ±0.5% Winding connection : Star with Neutral Total Distortion factor : Less than 1.5%on No Load,Non Distorting Balance Liner Load <5% Total Harmonic distortion in output waveform : < 5% AMF PANEL Cubical type floor mounted AMF panel made from 16 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 58.5 KVA DG set having following specification/features. i) 160A , MDO type ACB with O/L, S/C, E/F protection and microprocessor based protection release, U/V release etc. -2 sets (L&T/Siemens/ABB) ii) In Built By-Pass switch (160A) / CHANGE OVER Switch (160A). iii) On -delay timer for load change over iv) On-delay timer for engine shut off v) Engine On-Off switch (Push button type)
11 tank pretreatment process and UV resistant powder coating of all parts to withstand extreme environment Use of special hardware for longer life Fluid drains for lube oil and fuel External Fuel filling arrangement outside the enclosure must be certified as per CPCB-IV norms. BASE FRAME Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting hook. TERMS & CONDITIONS (i) Rate should be quoted inclusive of all applicable taxes and Duty etc. (ii) All materials, equipments & accessories must conform to relevant IS /IЕС specifications. The DG Set to be supplied must be from the authorized OEM of the respective Engine Manufacturer. iii) Necessary manufacturer's test certificate for Diesel Engine, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment. iv) Copy of "Type Approval Certificate" and Certificate of "COP" must be produced at the time of delivery issued from OEM (As per CPCB-IV). (v) Circuit Diagram for AMF Panel must be submitted from the Manufacturer / OEM. (vi) The entire set must be warranted at least 24 months from the date of Delivery/12 months/ 5000 Hrs from the date of Commissioning whichever is earlier. However Engine & Alternator should be warranted of 2 years/5000 Hrs, whichever is earlier. NOTE: (For item no. 64 to 64.03) 1.The Agency must procure the materials from the manufacture /OEM or from their authorised sales channel so that the standard warranty/support of the manufacture /OEM becomes applicable to the products to be delivered and installed by them 2.Documents that authenticates such procurement from the manufacture /OEM or from their authorised sales channel and standard warranty/support should be sent from the e-mail of the manufacture /OEM /authorised sales channel to the e mail of Engineer -in charge and hard copy of it to be submitted during execution of work/submission of Bill.
Providing cement concrete foundation for the DG set with 1:2:4 (1 cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size)[M20 grade ] including excavation, providing base concrete with 1:5:10 cement concrete, required centering/ shuttering, finishing the exposed portion etc. as reqd. ( Item will be paid based on measurements for 1:2:4 CC, but excluding the 1 : 5: 10 leveling course of base concrete) as per direction of E-in-Charge and manufacturer recommendation. (Size-4000 mm X 2450mm X 1500 mm)
Supply of HSD Oil.
Supply of Mobil Oil.
S & F exhaust pipe of 80 mm. dia MS black pipe (Thickness 4 mm) including connection with the existing silencer attached with the flexible coupler and S&F flange, nuts, bolts & washers etc. & necessary fixing materials etc. as required from DG set to nearest building (Horizontal Run) with suitable high temperature painting.
Making insulation by 2" glass wool including netting arrangement and covered with aluminium clading as per direction of the EIC. a) 80 mm. dia exhaust pipe.
b) Residential type silenser pipe
S&F special type MS angle iron structure support 20 feet height made of 50x50x6 mm M S angle (4 Nos), to be erect on ground level structure by C C foundaion for vertical support with flat iron 40mmX6 mm for horizontal support of the above angle like lattice structure with gap not greater than 300 mm with clamping arrangement for holding the M S pipe (Vertical Run) by means of M S flat iron clamp with nuts, bolts , washers etc. for clamping pipe line vertically.incl painting.
S&F rain protection canopy.
S& delivery of 200 ltrs. Capacity heavy gauge MS sheet barrel.
Supply & delivery of best quality oil motor pump set with 1" dia PVC flexible pipe (12' ft. approx.)
S & F compression type metal gland for 100 mm dia flexible pipe.
Commissioning & testing of the Diesel Generator Set along with AMF panel with agency's own tools & tackles in presence of EIC.
Cutting RCC floor by special tools & tackles very carefully without any damaging and removing the shifted rubbish & leveling up and restoring the surface for 8 nos. earth-pit as per direction of EIC.
Supply & laying of 1.1 KV grade 12 core 2.5 sq.mm. PVC copper conductor control cable by shaddle on wall to interconnect DG set with AMF panel.
S & F compression type brass cable gland suitable for 12 core 2.5 sq. mm. PVC/Ar copper cable.
Providing D G shed of size suitable for covering above 58.5 KVA D G set by Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (including the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm thick . washer etc. complete with 150 mm end lapa and one corrugation minimum side lap with M.S. structural works with 6 Nos M S pillars ( 3" X 3 " square bar of length 12 ft 3.2 mm thick 6.71 kg per mtr) and roof trusses with tubular sections ( 32 mm X 32 mm square bar 2.6 mm 2.26 kg per mtr ) conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The side portion of this sheded room is protected by MS wire net mesh ( 1" X 1" square net of 10 SWG wire) with suitable supporting M S bar or MS angle with 1 No opening ( 4 ft X 7 ft height ) door with locking arrangement incl all painting ( The dimention of this room / shed is 5000 mm X 3500 mm X height 3000 mm )
SUB-HEAD 1--DISTRIBUTION WIRING for D G Room Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make:Polycab/Havells/RR kabel) partly in 20mm size PVC rigid conduit 'FR' (Precision MMS make) on wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish. [ PVC Rigid Conduit on ceiling and remaining portion ] E 14/ 2b Avg Run:6 Mtr.
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make:Polycab/Havells/RR kabel) in 20mm size PVC rigid conduit 'FR' (Precision MMS make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish a) On board.[ 4a / E-15 ]
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS.19 mm dia 3 mm thick [ 6 (a)/ E- 3 ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Make:Havells/Polycab/RR Kabel of the following sizes in the prelaid polythene pipe as per GS. 2x(2.5 sqmm)+1x(1.5 sqmm) [ 1(s) / E-9 ]
2x(6 sqmm)+1x (4 sqmm) [ 1(b1) / E- 9 ]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes 2.5 sq.mm [9(i)/F-5]
6 sq.mm [9(i)/F-5]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall as per GS 175 x 100 x 65 [11(c)/E-4]
Supplying & Fixing bakelite/perspex cover on existing inspection board by brass screws. 175 x 100 x 65 [12(c)/E-4]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+8 Way [ Legrand ] [ 13 / D- 9 ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand ] 40 A DP [ 6 / D- 5 ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ] 6-32 SP [ 7 / D- 6]
Supplying and fixing 32A Dp Sheet steel Main Switches on flat iron frame on wall [ 1a / D- 1]
Supply of 4/2 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make KEI / Havells/R R Kabel ) 2 Core 10 Sq. mm [ NS ]
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes. 2.5 to 35 Sq. mm [ 5(i)/ F- 3 ]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. 2 Core 10 Sq. mm [7(c)/F4 & 8(b) /F5]
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Anchor) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [22/E-6]
Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS. [14(d)/C-2]
Supply of 4 Ft. 20 Watt single / twin LED light fitting for indoor application,complete with all accessories & Lamps having following Model / Cat No.( Make -Philips)Single LED 20W fitting (Crompton, Cat No-DIJB12L8-20/TMC 502 P 1xT-LED 22W P3241) 18W LED tube (PC body)) with tube (Cat No-LGT8-16-865-2) /Bajaj
Supply & Fixing 240V,Socket type fan regulator (Step type) (Brand approved by EIC) on existing switch board as per GS. [18a/E-6]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS [ 1 (a) /C-3]
Fixing only exhaust fan after making holes in wall as per GS. (9") [ 28(a)/C-4 ]
Supply & Fixing louver shutter ( Aluminum)on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS. (9") [ 32(a)/D-14 ]
Supply of 240V,1-Ph., 48" (1200mm) sweep, high speed AC ceiling fan, the capacitor of fan must be P-2 type brust proof & must have safety wire directly linked from fan hook to stator of fan. including safety wire and complete with all accessories like blades, canopy, fork, rubber bush, downrod etc. [Make :Crompton Aura Prime/Orient Quaser/Usha Striker PWD]
Supply & delivery 225mm (9") 1370 r.p.m. sweep A.C. single phase heavy duty exhaust fan complete set ready to use x as per G.S. (Make - E.P.C Electrical Pvt. Ltd./USHA/ORIENT) Warranty atleast 02 years from final billing period.
Excavation of soil for installation of Earth Electrode and filling & ramming as per GS For Morum Soil [1(b)/G-1 ]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With ISI-Medium GI pipe as per GS ISI Medium [ 2(a)/G-1]
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Extra for connecting the neutral of Transformer/Earth busbar to earth electrode including S & F 25 mm x 6 mm Galvanized (Hot Dip) steel strip on wall/floor with GI saddles & insulating the same by one layer of PVC strip over one layer of ampere tape
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts,washers, cable lugs etc. as required and mending good damages. 4 SWG [5(a)iii/G-2]
Dismantling the existing damaged electrical installations by Co’s own Skilled labour tools and tackles and mending surface as far as practicable [NS] ( 14 Nos Quarter )
Supply & Delivery of split type AC machines having Cooling Capacity range (min 6.6 kw to 7.0 kw),[Tonnage range 1.9Tr. -2.1Tr.] with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating -3 (EER range 3.5 to 3.99), Air flow range CFM (780-850), both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments (Make- Mitsubishi Electric/O-General /Mitsubishi Heavy)
Supply & Delivery of split type AC machines having Cooling Capacity range (min 5.05 kw to 5.30 kw), (Tonnage range1.5 to 1.6 Tr) with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating -3 (EER range 3.5 to 3.99), Air flow range CFM (560-600), both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments (Make- Mitsubishi Electric/O-General /Mitsubishi Heavy)
Supply & Installation of Extra Add-on items- HVAC grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above AC machine as per direction of EIC.( Maker for Cu pipe - Rajco,/ Royku,/ Mandev,/ Nippon & Make of Nitrile Rubber insulation - m Aeroflex/ K-flex/Accroflex/Armacell)
Supply & laying 3 core 4 sqmm PVC unarmoured "FR" copper Cable ( from OLP starter to A.C outdoor Connection) (Make- Gloster /Havells /Finolex/Polycab as approved by E.I.C)
Supply & laying 4 core 2.5 sqmm PVC unarmoured "FR" copper Cable ( from Split A C indoor to A.C outdoor Connection) (Make- Gloster /Havells /Finolex/Polycab as approved by E.I.C)
Providing for Installation of the above-said split AC outdoor unit by fixing iron angle frame / table on wall/ roof top & mending good the damages as per direction of E.I.C.
S & F of 5/8inch or 20mm dia PVC breaded flexible drain pipe without insulation.(Make: Supreme -as per direction of EIC)
S/F of 20 Amp plug top with necessary interconnection etc. ( Make Crabtree/ North West/ Anchor)
SITC OF 32 A 2 KW Single Phase Street light Timer Panel with 24 Hours / Astronomical Timer panel .(i) Enclosure: CRCA Sheet Steel duly phosphatized and powder coated with 7 tank process, with lock arrangment. (ii)414 V 32 A DP MCB- 1 No, (iii) Single phase 9 -24 A power contactor-1 L &T, (iv)Astronomical Timer - 1 no,(v) 16-20 A 230 V SPMCB-1 Nos. including connection wire & necessary connection.(L&T/Legrand/Havells)
Supply and Installation of 230Volt , 50Hz 10 ltr 2000watt water heater ( Geyser) 5 Star BEE Energy Rating ( make: Venus/ V- guard/ Bajaj)(Warrenty should be minimum 2years from OEM)
Rates to be quoted will be inclusive of all the taxes incl. GST. No other additional charges will be applicable in addition to the quoted rates.
S. A. ENTERPRISE (BID ID -6840969)
DELTA BROTHERS (BID ID -6840270)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .