Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹23.8 LAccepted-AOC WZ 109 PLOT NO 327 CHAND NAGAR NEW DELHI | 1 | Accepted-AOC Lowest bidder | |
| 2 | 2₹24.1 L+₹2,976.20 (0.12%)Rejected-Finance | 2 | Rejected-Finance Other than lowest | |
| 3 | 3₹25.5 L+₹1.5 L (6.19%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | 3 | Rejected-Finance Other than lowest | |
| 4 | 4₹27.4 L+₹3.3 L (13.8%)Rejected-Finance 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | 4 | Rejected-Finance Other than lowest | |
| 5 | 5₹27.9 L+₹3.8 L (15.8%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | 5 | Rejected-Finance Other than lowest |
Tender Value
₹30.7 L
EMD Value
₹61,460
Closing Date
15 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
GE(U)/PM/D-15/2020-21
2020_MES_342854_1
GE(U)/PM/D-15/2020-21
Open Tender
Civil Works
Item Rate
335 days
DELHI CANTT
MES contractor enlisted under class D category c(i) or d(v) having deposited standing security of Rs 50000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹61,460
Yes
10 Aug 2020
5 May 2020
17 Jun 2020
5 May 2020
15 Jun 2020
1 Jun 2020
60 days
Amount
SECTION -I
Maintenance and operation of AC plants of capacites 3 x 60 TR & 2 x 40 TR Central type AC Plants installed at Signal Enclave, Delhi Cantt-10, by providing Skilled AC Plant Operators (Ref Mechanic) round the clock in three shifts including Sundays and Holidays including provisioning of daily, weekly, monthly, quarterly and half yearly maintenance as per maintenance schedule stipulated and specified to the entire satisfaction of Engineer-in-Charge. The plant will be operated by three AC / refrigerator Mechanics (Skilled Labour) in three shifts by one mechanic in each shift in the following manner complete all as directed by Engr-in-Charge. (a) The details of mechanics and shifts are as under :- (i) 1st shift of 8 hours with timings 0600 hrs to 1400 hrs.-1 AC/ Refrigerator Mechanic in each shift (ii) 2nd shift of 8 hours with timings 1400 hrs to 2200 hrs.-1 AC/Refrigerator Mechanic in each shift (iii)3rd shift of 8 hours with timings 2200 hrs to 0600 hrs.-1 AC/Refrigerator Mechanic in each shift Total = 03 AC/ Refrigerator Mechanic (b) The duties of operator will be to operate the plant as per the directions of Engineer-in-Charge. The duty also includes to keep the desired temperature maintained in the rooms. Maintenance of AC plants will include daily checkup of plants, detection of leakage of refrigerant gas by nitrogen pressure testing and rectification of same in the AC plant, rectification of any leakage in water pipelines, cleaning of filters, filling of gland packing (graphite rope) of water pumps, descaling of condensors/chillers and water pipe lines & cleaning & maintenance of cooling towers including of PVC fills (New fills will be measured and paid seperately under relevent item as 'Supply only'.) (De-scaling chemical required for one times during currency of the contract period). Checking /Repairing to electrical faults in the electrical panel and motor of plants. Maintenance of plant will also include minor spares such as oil seal/packing, gasket, nuts, bolts and washers, PVC copper wires of sizes 1.5 Sqm to 6.0 Sqm (upto length 3 Mtrs Max) for electrical panels, lugs/thimbles upto 25 Sqmm complete all as specified and directed. (c) Filling/Topping up of refrigerant gas and compressor oil. (Refrigerant gas and compressor oil required for filling/topping up will be provided by the department).
(d) 3 x 60 TR AC plant comprises of the following :- (i) Water Cooled chiller package capacity 60 TR complete with condensor – 03 Nos. Make - Voltas. (ii) Mono block pump set capacity 10HP for Condenser – 02 Nos. Make - Kirloskar. (iii) Mono block pump set capacity 10HP for chiller pump 2900 RPM – 02 Nos. Make - Kirloskar. (iv) AHU complete 15000 CFM 4 RD Coil - 01 No. Make - Waves. (v) AHU complete 20000 CFM 4 RD Coil - 01 No. Make - Waves. (vi) Switch Board (LT Panel) for main plant - 01 No. Make L&T. (vii) Switch Board (LT Panel) for AHU complete - 02 Nos. Make L&T. (viii) Cooling tower complete with electric motor 5 HP - 01 No & Sintex tank of capacity 3000 ltr. Make-Mihir. (e) 2 x 40 TR Central type AC plant comprises of the following :- (i) Reciprocating type compressor - 02 Nos. Make - Voltas. (ii) Compressor motor 50 HP, 3 phase, 50 C/S - 02 Nos. (iii) Condensor shell and tube 40 TR cap – 02 Nos. (iv) Condensor water pump set 5 HP - 02 Nos. (v) AHU with coiling coil D x type and blower motor complete - 01 No. (vi) Electric control panel in plant room complete - 01 No. (vii) Control line device such as expansion valve, thermostat, solenoid valve, HP/LP cut off, oil failure gauge installed making electrical connection, testing and commissioning - 01 No. (viii) Cooling tower - 01 No. Make-Mihir.
Maintenance and operation of AC plants of capacity 3 x 115 TR AC Plant installed at HQ CAMS Delhi Cantt, having chilled water cooled type chilled plant including chilled water pump by providing AC Plant Operators (Ref Mechanic) in two shifts excluding Sundays and Holidays including provisioning of daily, weekly, monthly, quarterly and half yearly maintenance as per maintenance schedule stipulated and specified to the entire satisfaction of Engineer-in-Charge. The plant will be operated by two AC / refrigerator Mechanics (Skilled Labour) in two shifts in the following manner, complete all as directed by Engr-in-Charge:- (a) The details of mechanics and shifts are as under :- (i) 1st shift of 8 hours with timings 0600 hrs to 1400 hrs.-1 AC/Refrigerator Mechanic in each shift (ii) 2nd shift of 8 hours with timings 1400 hrs to 2200 hrs.-1 AC/Refrigerator Mechanic in each shift Total = 02 AC/ Refrigerator Mechanic (b) The duties of operator will be to operate the plant as per the directions of Engineer-in-Charge. The duty also includes to keep the desired temperature maintained in the rooms. Maintenance of AC plants will include daily checkup of plants, detection of leakage of refrigerant gas by nitrogen pressure testing and rectification of same in the AC plant, rectification of any leakage in water pipelines, cleaning of filters, filling of gland packing (graphite rope) of water pumps, descaling of condensors/chillers and water pipe lines & cleaning & maintenance of cooling towers including of PVC fills (New fills will be measured and paid seperately under relevent item as 'Supply only'.) (De-scaling chemical required for one times during currency of the contract period).. Checking /Repairing to electrical faults in the electrical panel and motor of plants. Maintenance of plant will also include minor spares such as oil seal/packing, gasket, nuts, bolts and washers, PVC copper wires of sizes 1.5 Sqm to 6.0 Sqm (upto length 3 Mtrs Max) for electrical panels, lugs/thimbles upto 25 Sqmm complete all as specified and directed. (c) Filling/Topping up of refrigerant gas and compressor oil. (Refrigerant gas and compressor oil required for filling/topping up will be provided by the department).
(d) The plant comprises of the following :- (i) Water Cooled chilled plant cap 115 TR complete with condensor – 03 Nos. Make - Voltas. (ii) Weather making unit with blower and blower motor - 06 Nos. Make - ABB. (iii) Cooling coil - 06 Nos. (iv) Pre-filter - 06 Lots. Make - Athletic. (v) FHP Pump for humidification - 06 Nos. Make - Jyoti. (vi) PVC tank for humidification - 06 Nos. (vii) Strip heaters of 3 KW for winter heating - 01 Lot. (viii) GI/MS 'B Class' ERW pipes and fittings for chilled water piping insulation - 01 Lot. (ix) Thermostat - 06 Nos. (x) Humidistat - 06 Nos. (xi) Pumping set for condenser water circulation - 02 Nos. Make - Beacon. (xii) Pumping set for chilled water circulation - 02 Nos. Make - Beacon. (xiii) Cooling tower cap 3 x 115 TR - 01 No. (xiv) GI sheet for fabricated ducts including duct insulation- 01 Lot. (xv) MS supply / return fresh air diffusers - 01 Lot. (xvi) LT Panel board complete - 01 No. (xvii) Electrical fittings - 01 Lot. (xviii) Material for electrical wiring - 01 Lot. (xix) PVC tank cap 5000 Ltr. Make-Sintex. (xx) Water softening Plant - 01. (xxi) MS expansion tank for chilled water of cap 1000 ltrs - 02 Nos.
Maintenance and operation of AC plants of capacity 3 x 8 TR AC Plant installed at HQ Delhi Area Signal Centre by providing AC Plant Operators (Ref Mechanic) in three shifts including Sundays and Gazetted Holidays including provisioning of daily, weekly, monthly, quarterly and half yearly maintenance as per maintenance schedule stipulated and specified to the entire satisfaction of Engineer-in-Charge. The plant will be operated by one AC / refrigerator Mechanics (Skilled Labour) in one shifts in the following manner, complete all as directed by Engr-in-Charge:- (a) The details of mechanics and shifts are as under :- (i) 1st shift of 8 hrs i:e from 0600 Hrs to 1400 Hrs- 01 AC/Refrigerator Mechanic per shift (ii) 2nd shift of 8 hrs i:e from 1400 Hrs to 2200 Hrs -- 01 AC/Refrigerator Mechanic per shift. (iii) 3rd shift of 8 hrs i:e from 2200 Hrs to 0600 Hrs -- 01 AC/Refrigerator Mechanic per shift. Total = 03 AC/ Refrigerator Mechanic . (b) The duties of operator will be to operate the plant as per the directions of Engineer-in-Charge. The duty also includes to keep the desired temperature maintained in the rooms. Maintenance of AC plants will include daily checkup of plants, detection of leakage of refrigerant gas by nitrogen pressure testing and rectification of same in the AC plant, rectification of any leakage in water pipelines, cleaning of filters, filling of gland packing (graphite rope) of water pumps, descaling of condensors/chillers and water pipe lines & cleaning & maintenance of cooling towers including of PVC fills (New fills will be measured and paid seperately under relevent item as 'Supply only'.) (De-scaling chemical required for one times during currency of the contract period). Checking /Repairing to electrical faults in the electrical panel and motor of plants. Maintenance of plant will also include minor spares such as oil seal/packing, gasket, nuts, bolts and washers, PVC copper wires of sizes 1.5 Sqm to 6.0 Sqm (upto length 3 Mtrs Max) for electrical panels, lugs/thimbles upto 25 Sqmm complete all as specified and directed.
(c) Filling/Topping up of refrigerant gas and compressor oil. (Refrigerant gas and compressor oil required for filling/topping up will be provided by the department). (d) The plant is comprising of the following :- (i) Reciprocating type Compressor Make- Acces/ Sebroe Model No. SMC 3-65 – 03 Nos. (ii) Compressor motor 10HP 3 phase 50 C/S AC – 03 Nos.(iii) Condenser shell & tube 8 TR Cap – 03 Nos. (iv) Condenser water pump set 3 HP – 02 Nos. (v) AHU with cooling coil & Blower Motor 3 HP - 01 No. (vi) Electric control panel in plant room - 01 No. (vii) Cooling tower FRP with water make up tank - 01 No. (viii) Humidity pump -01 No.
Notes applicable to BOQ Srl item No 1.01 to 1.05 :- (a) In case of any leakage of refrigerant gas due to mishandling of plant by the operator / mechanic, topping up of Refrigerant gas and finding of leakage including repairing shall be the responsibility of the contractor. (b) General cleanliness and upkeeping existing plants and vegetation within the premises of the plant with T&P if required at any time and all as directed by Engineer-in-Charge. (c) Contractor shall made payment through authorised bank and photocopy of receipt of payment shall be attached with RAR/FB. (d) Contractor shall monitor the duties of all AC/ refrigerator mechanic ands submit report to concerned Engr-in-Charge/JE E/M regarding availability of manpower and also monitor for watch and guard of installation . Any loss of damage to the plant equipment installed and Govt property in the E/M installation premises shall be made good by the Contractor. Rates quoted by the Contractor are deemed to be included for this clause. (f) Duty roster will be submitted by the contractor before commencement of the month for obtaining the approval of JE and Engineer-in-charge. Any change the duty roster will be made by the contractor, only after approval of Engineer-in-charge. (g) Contractor should arrange proper uniform with name plate displayed in shirt for the mechanics and its cost shall be deemed to be inclusive in the quoted rate. (h) The mechanics shall also be responsible to inform any complaint of non functioning of AC Plant to the Engr-In-Charge.
Notes applicable to BOQ Srl item No 1.01 to 1.05 (Contd...):- (j) The contractor shall provide reliever of AC/ Refrigerator mechanic/Electrician as per labour rules & regulations and the rates for which are deemed to be included in the quoted rate. (k) Contractor shall be responsible to monitor the duties of all AC/ Refrigerator mechanic/Electrician during change of shift and submit report to concerned Engr-in-Charge/ JE E/M the cost of same is deemed to be included in the quoted rate. (l) The rates quoted against providing manpower in Schedule ‘A’ item(s) (BoQ) is found to be less than the existing minimum labour wages (inclusive of EPF, ESIC, LWC and taxes), the bids will be declared as “Non-Bonafide” tender and will be rejected in financial evaluation. In such case the lowest tender shall be determined by lowest amount amongst valid bonafide bids for acceptance, whose rates found to be reasonable. The tender will be considered for financial evaluation only if the Section-I is found bonafied.
SECTION -2
Supply only PVC fills size 600x300x165 for cooling towers complete all as specified & directed by Engr-in-Charge. (Note:- Labour charge for taking down and fixing of new fills shall deemed to be included in the quoted rate in serial item No. 1.01, 1.03 & 1.05.)
M&L for preparation of surfaces of Cenral AC Plant of capacity 3x115 TR at HQ CAMS, trap door, condensers,chillers,compresors, Induction motors, pumps, hot water boiler, C channels, all pipe lines, valves and outer body of cooling towers and AHU's with different colors following the color code system as directed by the site-in-charge.Job includes removing the old paint by rubbing, brushing and applying one coat of red oxide zinc chrome primer and two coats of Synthetic Enamel Paint (1st grade quality) complete all as specified and directed by the Engr-in-Charge. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
-ditto- all as per item No. 4 above but Capacity of 3X60 TR at TRC Signal Enclave
-ditto- all as per item No. 4 above but Capacity of 2X40 TR at ASDC Signal Enclave
-ditto- all as per item No. 4 above but Capacity of 3X8 TR at HQ Delhi Area Signal Centre.
M & L for dismantling the existing old unserviceable Monoblock Pump set of any capacity and supply and fixing new monoblock pump set of 3.0 HP (2.2 KW) suction/delivery of size 65 mm x 50 mm CI casted, head 14.0 Mtrs, discharge, 8.4 LPS, Stainless steel impeller & pump shaft, mechanical seal, including 3.0 HP electric motor, copper wounded with 'F' class insulation & IP-55 protected, Cast Iron body, suitable for voltage range 300 to 440 Volts, ISI Marked, including making all electrical connections and testing for any leakage complete all as specified and directred by Engineer-in-Charge. (Make - Kirloskar pumps Model No. KDS 325++ or of equivalent in CROMPTON GREAVES/BEST & CROMPTON/BEACON/ KSS/ MOTHER & PLATT GRANDFOS).
M & L for dismantling the existing old unserviceable Monoblock Pump of any capacity and supply and fixing new monoblock pump set of 5.0 HP (3.7 KW) suction/delivery of size 80 mm x 65 mm CI casted, head 16.0 Mtrs, discharge, 14.30 LPS, Stainless steel impeller & pump shaft, mechanical seal, including 5.0 HP electric motor, copper wounded with 'F' class insulation & IP-55 protected, Cast Iron body, suitable for voltage range 300 to 440 Volts, ISI Marked, including making all electrical connections and testing for any leakage complete all as specified and directred by Engineer-in-Charge. (Make - Kirloskar pumps Model No. KDS 527++ or of equivalent in CROMPTON GREAVES/BEST & CROMPTON/BEACON/ KSS/ MOTHER & PLATT GRANDFOS).
M & L for dismantling the existing old unserviceable Monoblock Pump of any capacity and supply and fixing new monoblock pump set of 7.5 HP (5.5 KW) suction/delivery of size 100 mm x 100 mm CI casted, head 16.0 Mtrs, discharge, 24.00 LPS, Stainless steel impeller & pump shaft, mechanical seal, including 7.5 HP electric motor, copper wounded with 'F' class insulation & IP-55 protected, Cast Iron body, suitable for voltage range 300 to 440 Volts, ISI Marked, including making all electrical connections and testing for any leakage complete all as specified and directred by Engineer-in-Charge. (Make - Kirloskar pumps Model No. KDS 822++ or of equivalent in CROMPTON GREAVES/BEST & CROMPTON/BEACON/ KSS/ MOTHER & PLATT GRANDFOS). (Note for Item Nos. 8.00 to 10.00:- Any adjustment in existing pipe line and fixing arrangement in base frame required to be made to fit the new monoblock pump. The rate for the same is deemed to be included in the quoted rate.)
Sanjay Associates
P S TRADERS
SNOWY ENGINEERING INC
RUCHIKA ENGG.WORKS
Chauhan Associates
The new hut furnitures
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .