Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC | ₹34.4 L Quoted ₹34.6 L | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹35.6 L+₹95,385 (2.76%)Rejected-Finance NO 28 4TH A CROSS 1ST MAIN ROAD ATTUR LAYOUT YELAHANKA NEW TOWN BANGALORE 560064 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560064 | ₹35.6 L+₹95,385 (2.76%) | L2 | Rejected-Finance Not L1 bidder |
| 3 | L3₹36.3 L+₹1.7 L (4.87%)Rejected-Finance | ₹36.3 L+₹1.7 L (4.87%) | L3 | Rejected-Finance Not L1 bidder |
| 4 | L4₹37.7 L+₹3.1 L (8.86%)Rejected-Finance | ₹37.7 L+₹3.1 L (8.86%) | L4 | Rejected-Finance Not L1 bidder |
| 5 | L5₹38.6 L+₹4.0 L (11.5%)Rejected-Finance | ₹38.6 L+₹4.0 L (11.5%) | L5 | Rejected-Finance Not L1 bidder |
Tender Value
Refer Docs
EMD Value
₹93,000
Closing Date
1 Sept 2021, 6:00 pmClosed
GARRISON ENGINEER CENTRAL BANGALORE
MILITARY ENGINEER SERVICES GARRISON ENGINEER CENTRAL AGRAM POST BANGALORE 560007
SPECIAL REPAIR TO BUILDING NO P 17 OF ASC CENTRE AND COLLEGE UNDER GE CENTRAL BANGALORE
2021_MES_464931_1
8145E
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER CENTRAL BANGALORE
₹93,000
Yes
28 Sept 2021
3 Aug 2021
3 Sept 2021
3 Aug 2021
1 Sept 2021
18 Aug 2021
3 Aug 2021 - 17 Aug 2021
Amount
B/R PORTION/WORKS : Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing debris outside MD land complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc and removing debris outside MD land complete all as specified and directed.
Demolition of plain cement concrete (unreinforced) any description and in any position not otherwise specifically provided for such as in roof/chajja padding etc complete including removing the materials out side MD land complete all as specified and directed.
Demolition of reinforced cement concrete any description and in any position not otherwise specifically provided for etc (Manhole cover slab, linte, beam etc), cutting reinforcement steel to facilitate demolition of concrete including removing the materials out side MD land complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposing serviceable tiles to MES store and the rubbish/debris out side MD land complete all as specified and directed.
Taking down chowkats or frame, not exceeding 1.5 Sqm in each with shutters (without taking off shutter from the frame) complete all as specified and directed.
Taking down chowkats or frames, exceeding 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed.
Material and labour for cutting through brick walls for door, window and the similar other opening or enlarging existing opening converting window into door opening etc cutting out defective brick work for under pinning including providing fixing and removing shoring cleaning and stacking bricks removal of surplus bricks hardcore, rubish of the primeses to outside MD land complete all as directed.
S & F aluminium anodised coloured powder coated (minimum thickness of powder coating 50 micron) frame for doors, windows and ventilators with one or more rebates including jointing cleats for fixing etc complete all as directed.
S & F aluminium anodised coloured powder coated (minimum thickness of powder coating 50 micron) door shutter side hung type with style rails (Top, Bottom & lock rail) Top rail meeting style, lock rail of size 48 x 44mm, bottom rail size 108 x 44mm, all are made from anodised aluminium section including necessary jointing cleat, glazing clips, rubber packing, anodised aluminium snap beading, screws of suitable size & two numbers aluminium anodised handle, tower bolts, butt hinges of suitable size, etc complete all as specified and directed (Note : Thickness of aluminium section shall not be less than 1.5 mm).
S&F aluminium anodised coloured powder coated (minimum thickness of powder coating 50 micron) fixed/sliding type window/ventilators, aluminium sections weighing not less than 0.50kg per metre, all are made of from aluminium anodised section including necessary track, jointing cleat, glazing clips, rubber packing anodised aluminium snap beading, screws of suitable size, locking arrangement, aluminium grill and two numbers aluminium anodised handle, tower bolts, butt hinges of suitable size, etc complete all as specified and directed by the Engr-in-Charge.
M & L for Mild steel framed work such as grills, gratings, door, gates etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bar, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Supply only 4.00 mm thick, sheet glass, ordinary quality including oil putty/timber beads in square exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply only stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed
S&F for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed
M & L for non-skid, ceramic, heavy duty, coloured tiles, Grade B II(a), not less than 10mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.36 sqm, in floors etc, including 15 mm thick screed bed in cement mortar 1:4 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for glazed ceramic, coloured tiles, Grade B III, 450X350X6 to 7 mm thick as in skirting/dado/vertical surfaces including 10 mm thick screed bed in cement mortar 1:3 set & jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for Plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in channels and drains etc complete all as specified and directed.
M & L for extra for forming fair finished to concrete surface of drain 30cm inner girth in cement including forms, mould, mitred/stopped etc complete all as specified and as directed.
M&L for precast cement concrete block masonry type C1, 1:3:6 (20 mm graded granite stone aggregate) with solid blocks, exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
M & L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 10 mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
"Supply only" liquid water proofing compound complete all as specified and directed. (Make : Dr FIXIT/Fosroc/choksey)
M & L for roof treatment by providing 25mm thick padding in PCC 1:2:4 type B0 (Using 12.5 mm graded stone aggregate) finished fair and even and rendering 10mm thick in CM 1:4 mixed with water proofing compound by weight of cement as per manufacturer's instruction the applying oil bound bitumen primer @ 1.5 Kg/Sqm and providing 3 mm thick APP membrane weighing not less than 3.6 kg/sqm reinforced with non woven polyester matt weighing not less than 180 gm /sqm having softening point not less than 140 centigrade, having tensile strength of 650N/sqm and 350 N/sqm in longitudinal and transverse directions respectively of the reinforced tearing strength of 180N by torch application with minimum 10cm side overlap and 15cm end lap, applying a coat of blown grade hot bitumen 90/15 over the membrane @ 1.2 Kg /Sqm on top of membrane surface and then finished with solar reflective bituminious aluminium paint @ 0.10 Kg/Sqm complete all as specified and as directed. Note : Water proofing compound shall be measured and paid separately under respective item.
M&L preparation of plastered surfaces of wall and applying two coats of distemper using first quality acrylic distemper (ready mix) having VOC content less than 50 gms/ ltr of approved shade/tint all as per manufacturer's instruction including providing wall care putty two coats in minimum 1mm thick complete all as specified.
M&L complete removal of existing treatment of wall and applying two coats of distemper using first quality acrylic distemper (ready mix) having VOC content less than 50 gms/ ltr of approved shade/tint all as per manufacturer's instruction including providing wall care putty two coats in minimum 1mm thick complete all as specified.
M & L for preparation of old decorated surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
Taking up or down 15mm bore, Steel tubing and connections.
Taking up or down 20mm bore, Steel tubing and connections.
Supplying and laying of 16mm dia CPVC pipes (ISI marked) SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trenches complete all as specified.
Supplying and laying of 20mm dia CPVC pipes (ISI marked) SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trenches complete all as specified.
S&F in repair 15 mm bore bib taps cast copper alloy chromium plated with capstan head fancy type with wall flange screwed down to iron pipe complete all as specified and directed. Make: CERA Cat NO HT-F3001151 or equvelent of Make Hindware/Parryware/PRAYAG
S & F in repairs health faucet cast copper alloy with push button & 1 metre long flexible steel pipe with PVC lining suitable for 15mm bore pipe complete all as specified and directed. Make CERA Cat No F 8030103 or equvelent of Make : Hindware/Parryware/Prayag
S&F rotational moulded polyethylene water storage tanks 1000 litre capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including 20 mm dia brass ball/float valve high pressure with polythene float and flynut, 20 mm water tank nipple suitable for HDPE water tank, 20mm bore gun metal gate/globe valve with iron wheel head complete all as specified and directed.
S & F 110 mm bore, PVC (SWR), Type 'B', Soil waste and vent pipes in any length without ears, with solvent cement joints fixed to wall using MS holder bat, etc complete all as specified and directed.
S & F 75 mm bore, PVC (SWR), Type 'B', Soil waste and vent pipes in any length without ears, with solvent cement joints fixed to wall, using MS holder bat etc complete all as specified and directed.
S & F 110 mm bore, PVC (SWR) bends of any radius with acess door complete all as specified and directed.
S & F 75 mm bore, PVC (SWR) bends of any radius with acess door complete all as specified and directed.
S & F 75 mm dia outlet , PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
E/M PORTION/WORKS : Taking down copper/ aluminium surface type point wiring (light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good distrubed surfaces of wall, floors, etc complete.
Point wiring concealed type with PVC insulated and unsheathed FRLS cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS-694 1990 drawn in and including PVC rigid non metalic conduit (Medium grade) conforming to IS-9537 with all accessories including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly including cutting chases in stone masonry /concrete block masonry wall by using core cutting machine making good with cement mortar in 1:4, rendering finishing to match with existing complete all as specified for :- One light point controlled by one 6 Amps switch one way
All as per item No 43 above but for one light point controlled by one two way 6 Amps switch
All as per item No 43 above but for one 3 pin socket point 6 Amp on independent board
All as per item No 43 above but for one 3 pin socket point 6 Amp on same board with other switch.
All as per item No. 43 above but with 4 sqmm ( Nominal area ) cable (FRLS) with 4 Sqmm size copper earth continuity conductor (FRLS) for 3 pin 15 A socket outlet on independent board complete all as specified and directed. NOTE FOR ITEM NO 43 TO 47 : (i) Cost element for cutting chases to stone /concrete block masonry wall (by using core cutting machine) for point wiring including insertion of metal flush box and making good wall surface including cost of white wash or distempering wherever needed shall deemed to be inclusive in quotated rate. (ii) Cover plate and frame with metal flush box shall be measured and paid separately under respective item of BOQ.
Supply and fix modular white cover plate with frame 2 modules complete all as directed.
Supply and fix modular white cover plate with frame 3 modules complete all as directed.
Supply and fix modular white cover plate with frame 4 modules complete all as directed.
Supply and fix modular white cover plate with frame 6 modules complete all as directed.
Supply and fix modular white cover plate with frame 8 modules complete all as directed.
Supply and fix modular white cover plate with frame 12 modules complete all as directed.
Supply and fix metal flush box 2 modules for modular switch complete all as directed.
Supply and fix metal flush box 3 modules for modular switch complete all as directed.
Supply and fix metal flush box 4 modules for modular switch complete all as directed.
Supply and fix metal flush box 6 modules for modular switch complete all as directed.
Supply and fix metal flush box 8 modules for modular switch complete all as directed.
Supply and fix metal flush box 12 modules for modular switch complete all as directed.
Supply and fix blank plate one module complete all as directed.
Supply and fix blank plate two modules complete all as directed.
Supply and fix modular switch 1 way 6/10A,1 module
Supply and fix modular switch 1 way 16,1 module
Supply and fix modular switch 2 way 6/10A,1 module
Supply and fix modular socket 1 way 6/10A, 2/3 pin combined, 2 module
Supply and fix modular socket 1 way 6/16A, 2/3 pin combined, 2 module
Supply and fix Ceiling rose surface bakelite 65x50mm three terminals including supply and fix PVC blocks.
S&F in replacement 15 watts LED surface mounted down light with white powder coated polycarbonate decorative housing and pressure die-cast heat sink having high efficiency with heavy duty driver having THD <10% with all acessories internally prewired and connecting up with and including providing twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-charge. Make : Havells Cat No INTEGRANEOSURFACEDLS15WLED857S OR equivelant of make Shakti/Crompton Greaves/Bajaj
S&F 36 watts LED fitting CRESCENT LED's curved suspended design in a vision of refined beauty and gracefully blend with architectural elements of any room with its signature feature, the half moon shaped , this timeless luminare offers lelgant low-glare direct lighting and offers wider light distribution allowing greater uniformity on work planes. Introduce this eye-candy into contemporary spaces and create delight under its soft, direct light with all accessories internally pre-wired and connecting up with twin core flexible copper conductor cable of suitable size and lenth complete all as specified and directed. Make Havells Cat No CRESCENTTLP36WLED840SPCGRY or equivelent of Bajaj/phillips/CG
M & L for Sub main wiring (Concealed type) with four run of 10 sqmm (Nominal area) single core FRLS cable PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through grey colour PVC conduits, medium grade, of suitable size, fixed to wall/ceiling etc with all accessories, fittings, fixures including one run 10 sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, FRLS copper conductor as earth wire and duly connected to common earth point including PVC conduits/casing-caping of suitable size complete all as specified and as directed by Engineer-in-charge. (Note : (i) PVC Conduits, four run wiring cables and one run of earth wire will be measured as one length. (ii) Cost element for cutting chases to stone /concrete block masonry wall for wiring and making good wall surface using cement mortar 1:4 including cost of white wash or distempering wherever needed shall deemed to be inclusive in quotated rate)
M & L for Sub main wiring (Concealed type) with four run of 6 sqmm (Nominal area) single core FRLS cable PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through grey colour PVC conduits, medium grade, of suitable size, fixed to wall/ceiling etc with all accessories, fittings, fixures including one run 6 sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, FRLS copper conductor as earth wire and duly connected to common earth point including PVC conduits/casing-caping of suitable size complete all as specified and as directed by Engineer-in-charge. (Note : (i) PVC Conduits, four run wiring cables and one run of earth wire will be measured as one length. (ii) Cost element for cutting chases to stone /concrete block masonry wall for wiring and making good wall surface using cement mortar 1:4 including cost of white wash or distempering wherever needed shall deemed to be inclusive in quotated rate.)
M & L for Sub main wiring (Concealed type) with two runs of 6 sqmm (Nominal area) single core FRLS cable PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through grey colour PVC conduits, medium grade, of suitable size, fixed to wall/ceiling etc with all accessories, fittings, fixures including one run 6 sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, FRLS copper conductor as earth wire and duly connected to common earth point including PVC conduits/casing-caping of suitable size complete all as specified and as directed by Engineer-in-charge. (Note : (i) PVC Conduits, two run wiring cables and one run of earth wire will be measured as one length. (ii) Cost element for cutting chases to stone /concrete block masonry wall for wiring and making good wall surface using cement mortar 1:4 including cost of white wash or distempering wherever needed shall deemed to be inclusive in quotated rate)
Supply and fix in replacement Sheet metal enclosure (ISI marked) distribution board TPN,pre-wired 8 way (8+24 suitable for MCB/RCCB/Isolator as incomer), 415 volts, horizontal type double door type, 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface and tested on completion complete all as specified. Make : Havells Cat part No DHDMTHMLXW08 or equivalent model of Legrand/ABB/sceinder/L&T
Supply and fix Sheet metal enclosure (ISI marked) distribution board for 240 volts, SPN 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed. Make : Havells Cat part No DHDNSHODAW08 or equivalent model of Legrand/ABB/sceinder/L&T
Supply and fix Sheet metal enclosure (ISI marked) distribution board for 240 volts, SPN 4 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed. Make : Havells Cat part No DHDNSHODAW04 or equivalent model of Legrand/ABB/sceinder/L&T
Supply and fix MCB Tripple pole & neutral, 4 pole, 100 Amps 240 volts, C series,10 kA rupturing capacity providing in DB complete all as specified.
Supply and fix MCB Tripple pole & neutral, 4 pole, 40 to 63 Amps 240 volts, C series,10 kA rupturing capacity providing in DB complete all as specified.
Supply and fix MCB single pole & neutral 63 Amps 240 volts, C series,10 kA rupturing capacity
Supply and fix MCB single pole 6 to 32 Amps 240 volts, C series, 10 kA rupturing capacity
Supply and fixing 32 Amps 5 pin (3P+N+E) solution with insulated plug & socket including 32 Amps 4 pole MCB box flush to stone wall complete all as directed. Make : Havells Cat No DHDPBTN032 or equivalent model of Legrand/ABB/sceinder/L&T
Material and labour for Cutting hole/opening through stone masonry wall of 38cm thick by using core cutting machine suitable for provision of 300mm sweep exhaust fan and making good the disturbed surfaces using cement mortar 1:4 or PCC 1:2:4, type B1 as required including toothing and bonding, finished the surfaces to match with existing ie white/colour wash as required complete all as directed.
Supply and Fixing exhaust fan, 300mm sweep metal body, AC single phase 230/240 Volt including bird free louver shutter cut to fit with hole for exhaust fan including providing holes grouting bolts and 3 core flexible copper conductor cable of size 24/0.20 sqmm connecting up from ceiling rose to exhaust fan terminal complete all as directed. Make Havells/Crompton/Orient/Bajaj
S&F PVC casing caping of suitable size including all acessories such as tees, bends, elbows, junction box, reducers and fixing accessories such as couplers, lock nuts, saddles, pipe hooks screws, PVC sleeves etc. complete all as specified and directed.
Dismentling of existing serviceable LT panel by disconnecting cable connections, submains, meter etc and refixing in new location on wall surface including reconnetion of submain, meter etc complete all as directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc area not exceeding 10 Sqm on plan and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated material to a distance not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
M & L for Sand cushioning and covering with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed. (Note: Thickness after punning down shall be measured for payment)
Supply and laying well burnt bricks, locally available best quality bricks laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed.
S&F in replacement mild steel galvanized pipe light grade for protection & passing of LT cable fixed to poles/walls/laid under floor/roads complete including fittings/clamps as required at site all as specified for size of 50mm bore dia.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, GI strips armoured cable for working voltage 1100 volts, PVC insulated ,3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 70 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, culverts, under floors, through GI Pipe complete all as specified and as directed.
Design, fabrication, install and testing LT panel of CPRI approved factory, wall mounted having one side openable hinged double door shutters with locking arrangement outdoor type, weather proof, size 120cmX100cmX45cm made out of 3mm thick CRCA sheet, powder coated painting inside and outside fixing arrangement with 4 Nos clamps neoprene rubber gasket including earth terminal point, internal connection using suitable size copper conductor cable complete with the following accessories:- (a) MCCB, 4 pole, 415 volts, 25 kA, 160 Amps Capacity with thermal load release relay- 1 No (for incoming) (b) MCCB 4 pole, 415 volts, 25 kA, 63 Amps Capacity with thermal load release relay- 1 No (for outgoing) (c ) MCB TPN 63Amps, 10 KA, 'C' curve - 06 Nos (d) On load change over switch, TPN, 160 Amps - 01 No (e) 3 phase electric meter with CTs & PTs - 01 No (f) Bus bar chamber shall have 200 Amp rated copper strip Bus Bar with heat shrinkable insulating sleeve, size 40X6mm, 4 Nos of required length supported on FRP insulators, internal wiring for indicators with 10sqmm copper cable single core of required length. (g) Indicator lamps with LED bulbs for R,Y,B with copper cable wiring - 1 set. (h) Voltmeter and Ammeter with acessories complete - 01 Set (Make AT or equivalent)
S& F in replacement MCCB, 4 pole, 415 volts, 36 kA breaking capacity, 200 Amps with adjustable thermal and adjustable megnetic release fix in existing panel with spader line and other acessories complete all as directed.
M&L, Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thick buried directly in ground (earth pit depth not less than 2.25m deep below the ground level) with top edge of earth plate at a depth not less than 1.5m below ground level connected to earth using GI earth wire of 4mm dia by means of of nuts, bolts and washer and check nuts of GI or steel as shown in electrical plate No.3 of MES SSR-2009 (Part-I) and connected to earth test point all as specified or indicated including testing on completion with and including 15mm bore light grade GI protection pipe 7.5 metre long for earth including PCC (1:2:4) pit with RCC (1:2:4) type B-1 cover, 40mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hooks made out of 6mm dia MS bars, watering arrangement with 20mm dia light grade pipe, funnel, wire mesh, common salt chorcoal, necessary excavation and earth work in any type of soil complete all as specified.
Gnani Builders
HRML CONSTRUCTIONS
RASHMI BUILDERS
docileworx
RK Builders
SRI BALAJI INFRA PROJECTS
PAVAN TECHNO CONSTRUCTIONS
m/s raghavendra kulkarni
G K CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .