Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.4 LAdmitted-Finance 16 JAIN NAGAR TALAB TILLO JAMMU JAMMU KASHMIR 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L1 | Admitted-Finance | |
| 2 | L2₹64.5 L+₹10,000 (0.16%)Admitted-Finance JABALPUR | L2 | Admitted-Finance | |
| 3 | Rejected-Technical | - | Rejected-Technical CONDITIONS OF TECHANICAL BIDS NOT FULFILLED |
| Sl No | Description | Qty | Unit | AVG Contracts and Supplies pvt ltd L1 | UDAIRAJ INFRA POWER PRIVATE LIMITED L2 |
|---|---|---|---|---|---|
| 1.00WSS THATHRI (LIFT) | |||||
| 1.10 | Providing, installation, testing and commissioning of 2500 GPH x 150 meter head submersible pump set (with 1no. standby), lowering and fitting of GI column delivery pipes,length as per site conditions (approximately 100 meters) with the help of chain pulley block and tripod stand & other tools & tackles, together with nipples, adopters, sockets, valves, flanges, bends, clamps complete with requisite grooves, slots, welding work etc. and other allied work. Job includes providing, fitting and laying of 6mm2 flat submersible copper cable 3 core approximately 360 meters in length Job also includes providing and fabrication of M.S Gantry together with 5 ton chain pulley bloc for extraction/lowering of pumping machinery alongwith allied works. Job includes providing and fitting of 100 ampere MCCB. Complete job includes cost of machinery, equipments, material, hire charges of tools and tackles, manual carriage, transportation, loading / unloading and labour charges. | 1 | Job | 4,32,203.38 ₹5,10,000 | 4,00,000 ₹4,00,000 Lowest |
| 1.20 | Design, fabrication, installation, testing and commissioning of 50 ampere rating, 3 phase, LT control panel cum protection panel cum automatic star delta starter and MUG 30 as standby along-with allied works by way of fabrication of panel with 3 pole Main and delta power contactors of 50 rating 01 no. each and star power contactor of 50 A rating-1no., complete with all protection safety control devices / mechanism compatible with the design / rating of the prime mover, of reputed make, conforming to ISI standards. The system should be provided with fault analyzer cum controller unit or equivalent of standard and reputed make. The complete system should be enclosed in MS steel enclosure box of suitable dimensions. The enclosure should be finished with powder coated painting from inside as well as from outer surface of approved colour. Providing / laying of copper conductors of proper rating alongwith insulation material as per site requirement. The enclosure should be front shutter mounted with key locking system having glass window. Digital electronic voltmeter & ampere meter should be provided along with the required current transformer and selector switches. The internal control wiring should be done with flexible PVC LT cable with proper thimbling at each end. The system should trip the motor on power failure and on appearance of an electrical fault mentioned below which may otherwise damage the motor field coils and should not restart automatically until unless the system is reset manually, thus providing automation to the system and protection to the motor .The system / star delta auto starter should not fall into delta if it does not fall into star mode first and should remain de-energized to avoid damage to the motor / machinery and also to the power source / transformer. The system / star delta auto starter should trip off if it does not fall into delta & remains in star mode for more than 10-20 seconds. The system shall provide protection against: - Low voltage below 350 V, High Voltage above 450 V, Single phasing, Reverse phasing, Un Balanced phasing, Dry running, Overloading. In addition the system should have the following audio & visual features for a quick and accurate diagnosis of the appeared fault / status for a speedy rectification of the system-- Separate LED fault / status indicators, LED phase indicators. Isolation by pass system, for fault analysis of system, with a blinking indicator. An audio warning system/Siren which activates only on starter failure to trip the motor on appearance of any electrical fault mentioned above, to warn the operator to switch off the motor manually.3 LED, contactor ‘COIL OK’, indicators, one for each of the contactors / coils. LED star & delta indicators to access the star to delta timing. A tamper proof starting system to avoid manipulations by the motor operator to keep the system in a permanently ON position Testing of panel after making all incoming / outgoing connections on no load and then on full load. Proper chemical earthing of equipment should be done. Job includes cost of machinery, equipments and material, transportation charges, manual carriage charges, labour charges, loading /unloading charges, hire charges of tools and tackles etc. | 1 | Job | 1,24,576.28 ₹1,47,000 | 1,20,000 ₹1,20,000 Lowest |
| 1.30 | Providing, installation, testing and commissioning of 5000 GPH x 360 meter head HC pump set with suitable rating prime mover in compliance with the technical conditions and allied works by way of surveying of site, designing of pump machinery and prime mover in conformity with site conditions. Laying of M-20 grade RCC foundation block for each pump of size 6’x3’x4’ by using reinforcement steel of 10mm dia. The foundation block as per size of pump set should have additional margin of 6” on all sides. Providing, fabrication and laying of 80/100mm dia. MS suction pipe line to the pump set of length as per site conditions condition and upto maximum of approximately 6 meters each including 80/100mm dia. MS bends, MS flanges, expanders/reducers / dismantling joints / saddles/ pipe extension pieces, 80/100mm dia. Cast Iron sluice valve-1no. (PN rating 1.0), gaskets, nuts, bolts, washers as per site requirement. Providing, fabrication and laying of 80 mm dia. MS delivery pipe as per site conditions including MS bends, MS flange, expanders/reducers / dismantling joints/ saddles/ pipe extension pieces, Cast steel Sluice valve 80mm dia. and NRV 80mm along with bypass arrangement (class 300 accompanied with manufacturer’s in house test certificate)gaskets, nuts, bolts, washers. Job includes greasing work, P/F of graphited gland packing and thereafter testing on no load and then on full load and commissioning thereof. Job includes providing / fitting and laying of copper cable 35mm2 from motor to panel in six leads approximately 36 meters, then p/f and laying 50mm2 copper cable upto MCCB-bus bar-voltage stabilizer in three leads approximately 30 meters in length alongwith neutral wire conforming to ISI standards with proper thimbling and insulation material. Job covers providing and fitting of 250 ampere MCCB of 50 KA breaking strength Proper chemical earthing of the equipment should be done for safety of machinery. Job includes cost of machinery, equipments and material, transportation charges, manual carriage charges, labour charges, loading /unloading charges, hire charges tools tackles and material handling equipment etc. | 2 | Jobs | 7,66,949.15 ₹18,10,000 | 9,00,000 ₹18,00,000 Lowest |
| 1.40 | Making connection of sump outlet pipes with suction lines either directly / through 100/150mm dia MS pipe manifold (as per site conditions). Making connection of delivery lines with rising main through 100 mm dia. MS pipe manifold. Job includes providing laying and fixing of insulation rubber mats around electro mechanical machinery on the floor of the pump house. Job includes providing of welding set-1no maintenance took kit as per enclosed annexure. Job includes cost of machinery, equipments and material, transportation charges, manual carriage charges, labour charges, loading /unloading charges, hire charges of tools, tackles, and material handling equipment etc | 1 | Job | 84,745.76 ₹1,00,000 Lowest | 1,00,000 ₹1,00,000 Lowest |
| 1.50 | Design, fabrication, installation, testing and commissioning of 140 ampere rating, 3 phase, LT control panel cum protection panel cum automatic star delta starter along-with allied works by way of fabrication of panel with 3 pole Main and delta power contactors of 140 rating 01 no. each and star power contactor of 110 A rating-1no. complete with all protection safety control devices / mechanism compatible with the design / rating of the prime mover, of reputed make, conforming to ISI standards. The system should be provided with fault analyzer cum controller unit or equivalent of standard and reputed make. The complete system should be enclosed in MS steel enclosure box of suitable dimensions. The enclosure should be finished with powder coated painting from inside as well as from outer surface of approved colour. Providing / laying of copper conductors of proper rating along with insulation material as per site requirement. The enclosure should be front shutter mounted with key locking system having glass window. Digital electronic voltmeter & ampere meter should be provided along with the required current transformer and selector switches. The internal control wiring should be done with flexible PVC LT cable with proper thimbling at each end. The system should trip the motor on power failure and on appearance of an electrical fault mentioned below which may otherwise damage the motor field coils and should not restart automatically until unless the system is reset manually, thus providing automation to the system and protection to the motor .The system / star delta auto starter should not fall into delta if it does not fall into star mode first and should remain de-energized to avoid damage to the motor / machinery and also to the power source / transformer. The system / star delta auto starter should trip off if it does not fall into delta & remains in star mode for more than 10-20 seconds. The system shall provide protection against:-Low voltage below 350 V, High Voltage above 450 V, Single phasing, Reverse phasing, Un Balanced phasing, Dry running, Overloading. In addition the system should have the following audio & visual features for a quick and accurate diagnosis of the appeared fault / status for a speedy rectification of the system-- Separate LED fault / status indicators, LED phase indicators. Isolation by pass system, for fault analysis of system, with a blinking indicator. An audio warning system/Siren which activates only on starter failure to trip the motor on appearance of any electrical fault mentioned above, to warn the operator to switch off the motor manually.3 LED, contactor ‘COIL OK’, indicators, one for each of the contactors / coils. LED star & delta indicators to access the star to delta timing. A tamper proof starting system to avoid manipulations by the motor operator to keep the system in a permanently ON position Testing of panel after making all incoming / outgoing connections on no load and then on full load. Proper chemical earthing of equipment should be done. Job includes cost of machinery, equipments and material, transportation charges, manual carriage charges, labour charges, loading /unloading charges, hire charges of tools and tackles etc. | 2 | Jobs | 1,81,355.93 ₹4,28,000 | 2,00,000 ₹4,00,000 Lowest |
| 1.60 | Providing, carriage and installation of testing and commissioning of 150 KVA voltage stabilizers copper wound first quality CRGO silicon steel core naturally oil cooled manually operated 12 gauge container along with allied works . Job includes providing of 150 KVA voltage stabilizers complete with mineral insulating oil. MCCB change over switch complete with safety and protection devices etc. Job includes providing and fitting single core armoured al. cable 185 mm2 from electric pole to 400 Ampere main switch in four leads approximately 50 meters each and then providing and fitting of 50 mm2 copper cable from 400 main switch to voltage stabilizer approximately 20 meters in length. The voltage stabilizer should have 5 upwards steps and 2 downwards steps from the line voltage i.e. it should work from 180V to 400+5%. Voltage stabilizer should also be provided with T-oil, change over switch and MCCB of suitable rating. Proper chemical earthing of the equipment shall be done. Complete job include cost of machinery equipment and material, transportation charges, manual carriage charges labour charges loading /unloading charges hire charges tools and tackles etc. | 1 | Job | 5,08,474.58 ₹6,00,000 | 5,50,000 ₹5,50,000 Lowest |
| 2.00WSS THATHRI BUG (LIFT) | |||||
| 2.10 | Providing, installation, testing and commissioning of 2500 GPH x 120 meter head submersible pump set (with 1no. standby), lowering and fitting of GI column delivery pipes,length as per site conditions (approximately 110 meters) with the help of chain pulley block and tripod stand & other tools & tackles, together with nipples, adopters, sockets, valves, flanges, bends, clamps complete with requisite grooves, slots, welding work etc. and other allied work. Job includes providing, fitting and laying of 6mm2 flat submersible copper cable 3 core approximately 270 meters in length Job also includes providing and fabrication of M.S Gantry together with 5 ton chain pulley bloc for extraction/lowering of pumping machinery alongwith allied works. Job includes providing and fitting of 100 ampere MCCB. Complete job includes cost of machinery, equipments, material, hire charges of tools and tackles, manual carriage, transportation, loading / unloading and labour charges. | 1 | Job | 4,32,203.38 ₹5,10,000 | 5,00,000 ₹5,00,000 Lowest |
| 2.20 | Design, fabrication, installation, testing and commissioning of 50 ampere rating, 3 phase, LT control panel cum protection panel cum automatic star delta starter and MUG 30 as standby along-with allied works by way of fabrication of panel with 3 pole Main and delta power contactors of 50 rating 01 no. each and star power contactor of 50 A rating-1no., complete with all protection safety control devices / mechanism compatible with the design / rating of the prime mover, of reputed make, conforming to ISI standards. The system should be provided with fault analyzer cum controller unit or equivalent of standard and reputed make. The complete system should be enclosed in MS steel enclosure box of suitable dimensions. The enclosure should be finished with powder coated painting from inside as well as from outer surface of approved colour. Providing / laying of copper conductors of proper rating alongwith insulation material as per site requirement. The enclosure should be front shutter mounted with key locking system having glass window. Digital electronic voltmeter & ampere meter should be provided along with the required current transformer and selector switches. The internal control wiring should be done with flexible PVC LT cable with proper thimbling at each end. The system should trip the motor on power failure and on appearance of an electrical fault mentioned below which may otherwise damage the motor field coils and should not restart automatically until unless the system is reset manually, thus providing automation to the system and protection to the motor .The system / star delta auto starter should not fall into delta if it does not fall into star mode first and should remain de-energized to avoid damage to the motor / machinery and also to the power source / transformer. The system / star delta auto starter should trip off if it does not fall into delta & remains in star mode for more than 10-20 seconds. The system shall provide protection against:-Low voltage below 350 V, High Voltage above 450 V, Single phasing, Reverse phasing, Un Balanced phasing, Dry running, Overloading. In addition the system should have the following audio & visual features for a quick and accurate diagnosis of the appeared fault / status for a speedy rectification of the system-- Separate LED fault / status indicators, LED phase indicators. Isolation by pass system, for fault analysis of system, with a blinking indicator. An audio warning system/Siren which activates only on starter failure to trip the motor on appearance of any electrical fault mentioned above, to warn the operator to switch off the motor manually.3 LED, contactor ‘COIL OK’, indicators, one for each of the contactors / coils. LED star & delta indicators to access the star to delta timing. A tamper proof starting system to avoid manipulations by the motor operator to keep the system in a permanently ON position Testing of panel after making all incoming / outgoing connections on no load and then on full load. Proper chemical earthing of equipment should be done. Job includes cost of machinery, equipments and material, transportation charges, manual carriage charges, labour charges, loading /unloading charges, hire charges of tools and tackles etc. | 1 | Job | 1,20,338.98 ₹1,42,000 | 1,20,000 ₹1,20,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
10 Nov 2023, 3:00 pmClosed
XEN JAL SHAKTI PHE MECHANICAL DIVISION UDHAMPUR
MH MORH
Providing, installation, testing and commissioning of electro-mechanical machinery alongwith allied works at Thathri (lift) and Thathri Bug (Lift)
2023_PHE_235553_1
ENIT NO. 65-JJM OF 2023-24
Open Tender
Repair and Maintenance Works
Item Rate
120 days
XEN JAL SHAKTI PHE MECHANICAL DIVISION UDHAMPUR
Providing, installation, testing and commissioning of electro-mechanical machinery alongwith allied works at Thathri (lift) and Thathri Bug (Lift)
8 documents required · 8 mandatory
₹500
XEN JAL SHAKTI PHE MECHANICAL DIVISION UDHAMPUR
₹1.3 L
Yes
6 Dec 2023
2 Nov 2023
11 Nov 2023
2 Nov 2023
10 Nov 2023
2 Nov 2023
Amount
WSS THATHRI (LIFT)
Providing, installation, testing and commissioning of 2500 GPH x 150 meter head submersible pump set (with 1no. standby), lowering and fitting of GI column delivery pipes,length as per site conditions (approximately 100 meters) with the help of chain pulley block and tripod stand & other tools & tackles, together with nipples, adopters, sockets, valves, flanges, bends, clamps complete with requisite grooves, slots, welding work etc. and other allied work. Job includes providing, fitting and laying of 6mm2 flat submersible copper cable 3 core approximately 360 meters in length Job also includes providing and fabrication of M.S Gantry together with 5 ton chain pulley bloc for extraction/lowering of pumping machinery alongwith allied works. Job includes providing and fitting of 100 ampere MCCB. Complete job includes cost of machinery, equipments, material, hire charges of tools and tackles, manual carriage, transportation, loading / unloading and labour charges.
Providing, installation, testing and commissioning of 5000 GPH x 360 meter head HC pump set with suitable rating prime mover in compliance with the technical conditions and allied works by way of surveying of site, designing of pump machinery and prime mover in conformity with site conditions. Laying of M-20 grade RCC foundation block for each pump of size 6’x3’x4’ by using reinforcement steel of 10mm dia. The foundation block as per size of pump set should have additional margin of 6” on all sides. Providing, fabrication and laying of 80/100mm dia. MS suction pipe line to the pump set of length as per site conditions condition and upto maximum of approximately 6 meters each including 80/100mm dia. MS bends, MS flanges, expanders/reducers / dismantling joints / saddles/ pipe extension pieces, 80/100mm dia. Cast Iron sluice valve-1no. (PN rating 1.0), gaskets, nuts, bolts, washers as per site requirement. Providing, fabrication and laying of 80 mm dia. MS delivery pipe as per site conditions including MS bends, MS flange, expanders/reducers / dismantling joints/ saddles/ pipe extension pieces, Cast steel Sluice valve 80mm dia. and NRV 80mm along with bypass arrangement (class 300 accompanied with manufacturer’s in house test certificate)gaskets, nuts, bolts, washers. Job includes greasing work, P/F of graphited gland packing and thereafter testing on no load and then on full load and commissioning thereof. Job includes providing / fitting and laying of copper cable 35mm2 from motor to panel in six leads approximately 36 meters, then p/f and laying 50mm2 copper cable upto MCCB-bus bar-voltage stabilizer in three leads approximately 30 meters in length alongwith neutral wire conforming to ISI standards with proper thimbling and insulation material. Job covers providing and fitting of 250 ampere MCCB of 50 KA breaking strength Proper chemical earthing of the equipment should be done for safety of machinery. Job includes cost of machinery, equipments and material, transportation charges, manual carriage charges, labour charges, loading /unloading charges, hire charges tools tackles and material handling equipment etc.
Making connection of sump outlet pipes with suction lines either directly / through 100/150mm dia MS pipe manifold (as per site conditions). Making connection of delivery lines with rising main through 100 mm dia. MS pipe manifold. Job includes providing laying and fixing of insulation rubber mats around electro mechanical machinery on the floor of the pump house. Job includes providing of welding set-1no maintenance took kit as per enclosed annexure. Job includes cost of machinery, equipments and material, transportation charges, manual carriage charges, labour charges, loading /unloading charges, hire charges of tools, tackles, and material handling equipment etc
Providing, carriage and installation of testing and commissioning of 150 KVA voltage stabilizers copper wound first quality CRGO silicon steel core naturally oil cooled manually operated 12 gauge container along with allied works . Job includes providing of 150 KVA voltage stabilizers complete with mineral insulating oil. MCCB change over switch complete with safety and protection devices etc. Job includes providing and fitting single core armoured al. cable 185 mm2 from electric pole to 400 Ampere main switch in four leads approximately 50 meters each and then providing and fitting of 50 mm2 copper cable from 400 main switch to voltage stabilizer approximately 20 meters in length. The voltage stabilizer should have 5 upwards steps and 2 downwards steps from the line voltage i.e. it should work from 180V to 400+5%. Voltage stabilizer should also be provided with T-oil, change over switch and MCCB of suitable rating. Proper chemical earthing of the equipment shall be done. Complete job include cost of machinery equipment and material, transportation charges, manual carriage charges labour charges loading /unloading charges hire charges tools and tackles etc.
WSS THATHRI BUG (LIFT)
Providing, installation, testing and commissioning of 2500 GPH x 120 meter head submersible pump set (with 1no. standby), lowering and fitting of GI column delivery pipes,length as per site conditions (approximately 110 meters) with the help of chain pulley block and tripod stand & other tools & tackles, together with nipples, adopters, sockets, valves, flanges, bends, clamps complete with requisite grooves, slots, welding work etc. and other allied work. Job includes providing, fitting and laying of 6mm2 flat submersible copper cable 3 core approximately 270 meters in length Job also includes providing and fabrication of M.S Gantry together with 5 ton chain pulley bloc for extraction/lowering of pumping machinery alongwith allied works. Job includes providing and fitting of 100 ampere MCCB. Complete job includes cost of machinery, equipments, material, hire charges of tools and tackles, manual carriage, transportation, loading / unloading and labour charges.
Providing, installation, testing and commissioning of 5000 GPH x 200 meter head HC pump set with suitable rating prime mover in compliance with the technical conditions and allied works by way of surveying of site, designing of pump machinery and prime mover in conformity with site conditions. Laying of M-20 grade RCC foundation block for each pump of size 6’x3’x4’ by using reinforcement steel of 10mm dia. The foundation block as per size of pump set should have additional margin of 6” on all sides. Providing, fabrication and laying of 80/100mm dia. MS suction pipe line to the pump set of length as per site condition and upto maximum of approximately 6 meters each including 80/100mm dia. MS bends, MS flanges, expanders/reducers / dismantling joints / saddles/ pipe extension pieces, 80/100mm dia. Cast Iron sluice valve-1no. (PN rating 1.0), gaskets, nuts, bolts, washers as per site requirement. Providing, fabrication and laying of 80 mm dia. MS delivery pipe as per site conditions including MS bends, MS flange, expanders/reducers / dismantling joints/ saddles/ pipe extension pieces, Cast steel Sluice valve 80mm dia. and NRV 80mm along with bypass arrangement (class 300 accompanied with manufacturer’s in house test certificate)gaskets, nuts, bolts, washers. Job includes greasing work, P/F of graphited gland packing and thereafter testing on no load and then on full load and commissioning thereof. Job includes providing / fitting and laying of copper cable 25mm2 from motor to panel in six leads approximately 36 meters, then p/f and laying 35mm2 copper cable upto MCCB-bus bar-voltage stabilizer in three leads approximately 30 meters in length alongwith neutral wire conforming to ISI standards with proper thimbling and insulation material. Job covers providing and fitting of 250 ampere MCCB of 50 KA breaking strength Proper chemical earthing of the equipment should be done for safety of machinery. Job includes cost of machinery, equipments and material, transportation charges, manual carriage charges, labour charges, loading /unloading charges, hire charges tools tackles and material handling equipment etc.
Making connection of sump outlet pipes with suction lines either directly / through 100/150mm dia MS pipe manifold (as per site conditions). Making connection of delivery lines with rising main through 100 mm dia. MS pipe manifold. Job includes providing laying and fixing of insulation rubber mats around electro mechanical machinery on the floor of the pump house. Job includes providing of welding set-1no, maintenance took kit as per enclosed annexure. Job includes cost of machinery, equipments and material, transportation charges, manual carriage charges, labour charges, loading /unloading charges, hire charges of tools, tackles, and material handling equipment etc.
Providing, carriage and installation of testing and commissioning of 100 KVA voltage stabilizers copper wound first quality CRGO silicon steel core naturally oil cooled manually operated 14 gauge container along with allied works. The job includes providing of 100 KVA voltage stabilizer complete with mineral insulating oil. MCCB change over switch complete with safety and protection devices etc. Job includes providing and fitting of single core armoured al. cable 120mm2 from electric pole to 250 Ampere main switch in four leads approximately 50 meters each and then providing and fitting of 35mm2 copper cable from 250main switch to voltage stabilizer approximately 20 meters in length. The voltage stabilizer should have 5 upwards steps and 2 downwards steps from the line voltage. i.e. it should work from 180V to 400+5%. Voltage stabilizer should also be provided with T-oil, change over switch and MCCB of suitable rating. Proper chemical earthing of the equipment shall be done. Complete job include cost of machinery equipment and material, transportation charges, manual carriage charges labour charges loading /unloading charges hire charges tools and tackles etc.
UDAIRAJ INFRA POWER PRIVATE LIMITED
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .