Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC NAGAR PANCHAYAT PATHARDEVA DEORIA | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.1 L+₹1.5 L (31.0%)Rejected-Finance H NO 2049 HANUMAN COLONY NEAR TCP 3 HISAR CANTT PIN 125006 HARYANA | HISAR | HARYANA | 125006 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹6.8 L+₹2.1 L (44.5%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹7.7 L+₹3.0 L (65.2%)Rejected-Finance NOT FOUND | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹7.8 L+₹3.1 L (65.9%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
1 May 2024, 6:00 pmClosed
GE (AF) SIRSA
GE (AF) SIRSA, HARYANA-125055
REPAIR/MAINT OF EXISTING EARTHING, LA SYSTEM AND CONNECTED E/M WORKS AT AF STN SIRSA
2024_MES_649827_1
GE/SRA/T-04/2024-25
Open Tender
Miscellaneous Works
Item Rate
240 days
GE (AF) SIRSA
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) SIRSA
₹30,000
Yes
6 May 2024
10 Apr 2024
2 May 2024
10 Apr 2024
1 May 2024
19 Apr 2024
Amount
M&L Checking of Earth Resistance of Chemical/Normal Earthing and maintaining the Register as per Appendix 'A' and as specified and directed here-in-after :- NOTES :- (a) Contractor will Check Earth Resistance Every Day (minimum 25 Nos. per Day) and joint measurement of earth resistance of chemical /plate electrode earthing with user, will be sole responsibility of contractor. Earthing register will maintain and signed by user also and same will be put up to the Engineer-in-Charge through JE E/M on the Very Next Day, failing which a Sum of Rs. 20.00 per Day will be recovered from the Contractor. (b) New Earth Resistance Tester will be provided by the Contractor. (Tester should be caliberated from NABL accredited labs). (c) Contractor will be responsible for pouring of water in the Earth Pits Weekly at his own arrangement with Water Tanker, etc. However, Water will be provided by the Department. (d) Checking of Earth Pits existing and improve it by watering, adding of chemical etc. (Chemical will be measured and paid separately) (e) Contractor will be responsible for marking of Earth Check date and due date on existing Plate with paint as specified by Engineer-in-Charge. (f) Contractor will be responsible for cleaning of bushes, grass, sand etc inside and all around upto 1.50 Metre Area of existing Earth Pit with tightening of Strip. (g) Repair Party will be reported every Morning and Evening to JE E/M. (h) Cost of register for noting earthing results, location wise shall deemed to be included with the unit rate. Proforma of detail column will be printed as per the direction of Engineer-in-charge. (j) Recovery for Penalty will be made as follows :- (i) Earthing left without Checked lesser by 25 No. - Rs. 50.00/Earthing (ii) Earthing left without Checked in a Month - Rs. 100.00/Earthing (iii) Earthing left without Cleaning in a Month - Rs. 50.00/Earthing (iv) Earthing left without Watering in a Month - Rs. 30.00/Earthing (k) Contractor will be responsible for maintaining permissible earth resistance in Ohms in Earthing Register, failing which he will be liable to pay penalty as per IAFW-2249 and work shall be re-done by contractor in their quoted rate.
M&L for dismantling/taking out old unserviceable Chemical/ Normal earthing pit with all accessories after disconnection of earth strips including earth work as required complete all as specified and as directed.
Supply, installation, testing of CPRI tested maintenance free earthing system a set of Copper Bonded Earth Rod of 3 meter length, 17.2 mm dia made of high tensile low carbon steel circular rods, molecularly bonded with 99.9% electrolytic grade copper on outer surface (minimum copper bonding thickness-250 microns) with exothermically jointed copper bus bar of 200x50x6mm for long lasting and connection, copper bonded rod & exothermically jointed bus bar duly CPRI tested on 25 KA fault current and earth pit filled with duly by electrodite/conductolite back fill comound (Ground enhancer) complete for achieving earth resistance not more than 01 Ohm complete all as specified and as directed. (NOTE: Boring, Pit Cover and ground enhancing compound shall be measured and paid seperately)
Supply and installation of advance encapsulated compound based CPRI tested and approved maintenance free, pipe-in-pipe technology upgraded (Zinc & Ally coated), zinc coated (80-100) microns, Earthing system conforming to to IS 3034. The dia of outer and inner pipe should be 76.2 mm and 41.9 mm witth 3 metres length, zinc coated with additional special alloy coating 300 mm on the topside for additional corrosion protection of the terminal. The annular space between the pipes shall be filled up with Compact Fill (CF) crystalline conductive compound. The Compact Fill (CF) mixture which is machine pressed in the pipes should be extended with terminals for connectivity and earth pit filled with duly by electrodite/conductolite back fill comound (Ground enhancer) complete for achieving earth resistance not more than 01 Ohm complete all as specified and as directed. (NOTE: Boring, Pit Cover and ground enhancing compound shall be measured and paid seperately)
M&L for boring in loose/soft soil 200mm dia, by means of hand/ machine drill, upto 3 Meter depth from ground level and pouring of sufficient water for at least 3 times per day (within working hours) for two days and making hole ready for pouring of Earth Enhancement Compound complete all as specified and as directed. (NOTE: Earth Enhancing Compound shall be measured and paid seperately)
Supply and pouring of RoHS tested Earth Enhancement Compound after mixing with water tested by NABL accredited lab in compliance to IEC 62561-7 with a resistivity < 0.12 ohm-m. It shall be free from bentonite and other hazardous substances. It shall be a permanent, non-corrosive material and will not leach any chemicals into the ground. It shall retain moisture even in high soil resistivity areas. complete all as specified and as directed. Note: Measurement of Chemical will be done in Powder form. Contractor shall procure the item in sealed packets directly from manufacturer)
S&F in repair Earth Pit 125mm dia with FRP Earth Pit Cover of top size 200x200mm bottom size 300x300mm with height of 150mm with lockable Lid, Earth Pit cover shall be made of Poly plastic tested at 7.5 ton load for closing of earth pits complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron wire 4 mm dia (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 25 X 4 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 32 X 6 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
M&L for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to copper strip 20 X 3 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
M&L for replacement of PCC Pit in Cement Concrete 1:3:6 type C-1 (20mm graded crushed stone aggregate) with Cast iron cover 10mm thick hinged, Cast Iron Frame, MS Rod 6mm, Funnel as shown in Electrical Plate No 3 of MES Schedule Part-I including demolition of existing damaged pit and excavation work required at site, complete all as specified and as directed. Note : Rate shall be included for dismantling and removal debris of existing PCC pit.
M&L for replacement of Pre-cast RCC Cover with Handle 01 Nos and hole of dia 40mm in Cement Concrete 1:2:4 (20mm graded stone aggregate) of size 540x540x60mm, reinforced with and including 10mm dia TMT Bars @ 250mm Centre to Centre in both ways, complete all as specified and as directed. Note : Rate shall be included for dismantling and removal debris of existing RCC cover pit.
M&L Checking of any breaking in the Link of Earth Strip/Wire of Galvanised/ Copper/Aluminium any size and jointing them by Exothermic Welding or Brazing, complete all as specified and as directed.
Taking out loose/displaced Serviceable Aluminium Strip/ Copper Strip/ GI Strip of any size and any description with Accessories and refixing the same with necessary Fixing Arrangement like Screws, Saddles, inculators, Nuts and Bolts, complete all as specified and as directed. Note : Cost of Screws, Saddles, insulators, Nuts and Bolts etc. shall be deemed to be included in Quoted Rate.
S&F in repair copper strip 20mm X 3 mm with saddles and fixing screws etc, for roof conductors and down conductors above ground including provn of porcelain insulator @ 1.0 m spacing complete all as specified and directed. Note: Cost of Screws, Saddles, Insulators, Nuts and Bolts, etc. shall be deemed to be included in Quoted Rate.
S&F in repair copper strip 25mm X 4 mm with saddles and fixing screws etc, for roof conductors and down conductors above ground including provn of porcelain insulator @ 1.0 m spacing complete all as specified and directed. Note: Cost of Screws, Saddles, Insulators, Nuts and Bolts, etc. shall be deemed to be included in Quoted Rate.
S&F in repair copper strip 32 mm X 6 mm with saddles and fixing screws etc, for roof conductors and down conductors above ground including provn of porcelain insulator @ 1.0 m spacing complete all as specified and directed. Note: Cost of Screws, Saddles, Insulators, Nuts and Bolts, etc. shall be deemed to be included in Quoted Rate.
S&F in repair Galvanised Iron Strip 32x6mm with Saddles and fixing Screws for Roof/Earth Conductors and Down Conductors, complete all as specified and as directed. Note: Cost of Screws, Saddles, Insulators, Nuts and Bolts, etc. shall be deemed to be included in Quoted Rate.
S&F in repair Galvanised Iron Strip 25x4mm with Saddles and fixing Screws for Roof/Earth Conductors and Down Conductors, complete all as specified and as directed. Note: Cost of Screws, Saddles, Insulators, Nuts and Bolts, etc. shall be deemed to be included in Quoted Rate.
S&F in repair Aluminium Strip 25x3mm with Saddles and fixing Screws for Roof/ Earth Conductors and Down Conductors above Ground, complete all as specified and as directed. Note: Cost of Screws, Saddles, Insulators, Nuts and Bolts, etc. shall be deemed to be included in Quoted Rate.
S&F in repair Aluminium Strip 25x4mm with Saddles and fixing Screws for Roof/ Earth Conductors and Down Conductors above Ground, complete all as specified and as directed. Note: Cost of Screws, Saddles, Insulators, Nuts and Bolts, etc. shall be deemed to be included in Quoted Rate.
S&F in repair Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire, complete all as specified and as directed. Note: Cost of Screws, Saddles, Insulators, Nuts and Bolts, etc. shall be deemed to be included in Quoted Rate.
S&F in repair Air Termination Single Pointed Aluminium Rod 16mm dia and 500mm long with Arrester Clamp 16mm made out of Brass/ Gun Metal including provision of Cement Concrete 1:2:4 (20mm graded stone aggregate) Block 300x300x300mm, complete all as specified and as directed.
S&F in repair Air Termination Single Pointed copper Rod 16mm dia with brass base and 500mm long with Arrester Clamp 16mm made out of Brass/ Gun Metal including provision of Cement Concrete 1:2:4 (20mm graded stone aggregate) Block 300x300x300mm, complete all as specified and as directed.
S&F in repair Test Point Terminal Block made of Gun Metal or Phosphorus Bronze size 75x75x25mm, drilled and screwed including 3 No. 8mm dia, 25mm long hexagonal Head Screw, complete all as per specified and as directed.
S&F in repair PVC conduit, 16 mm OD, medium grade for wire Protection, fixed in Walls/Floors with suitable type of Clamps, etc., complete all as specified and as directed.
S&F in repair Galvanised Iron Tubing/Pipe 15mm bore (dia), light grade for wire Protection, fixed in Walls/Floors with suitable type of Clamps, etc., complete all as specified and as directed.
S&F in repair Galvanised Iron Tubing/Pipe 25mm bore (dia), light grade for wire Protection, fixed in Walls/Floors with suitable type of Clamps, etc., complete all as specified and as directed.
S&F in repair Galvanised Iron Tubing/Pipe 40mm bore (dia), light grade for Strip Protection, fixed in Walls/Floors with suitable type of Clamps, etc., complete all as specified and as directed.
S&F in repair Galvanised Iron Tubing/Pipe 50mm bore (dia), light grade for Strip Protection, fixed in Walls/Floors with suitable type of Clamps, etc., complete all as specified and as directed.
M&L Mild Steel Work for earth marker including necessary cutting, fabrication, drilling, bolting or riveting and locking arrangement, etc. and similar work, conforming to Fe-290 Gde E-165 including dismantl ing unserviceable Mild Steel Work, complete all as specified and as directed. Note:- Rate included for painting of mild steel work and marking of Earth Plate Number/ Description of Earthing/Type of Earthing on Plate with White Paint including Earth Plate No. and Earthing Resistance with Earthing Check Date and Earthing Check Due Date.
STAR CONSTRUCTIONS
AMBIKA ENTERPRISES
shiv shanker enterprises
YOGINDER KUMAR GUPTA AND COMPANY
M/s MANN CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .