Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹7,000
Closing Date
13 Nov 2020, 11:30 amClosed
EE EnM WnS South II
Apollo B.P.S., Sarita Vihar (Near Apollo Hospital) New Delhi 110076
Repair and Renovation of LT Starter Panel of Shamshan Ghat M.B. Extn. Booster Pumping Station in Badarpur Constituency.
2020_DJB_196445_7
NIT No. 17 EE EnM WnS South II (2020-21)
Open Tender
Miscellaneous Works
Works
30 days
EE EnM WnS South II
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
A/c No. 50448339804
₹7,000
1 Jan 2021
6 Nov 2020
13 Nov 2020
6 Nov 2020
13 Nov 2020
6 Nov 2020
Dismantling the Main electric connection with the main line to panel with all safety tools.
Replacement and refining with wiring incomer consisting of following:-1 no. automatic Phase Sequence Correcting Power Switch Circuit with a provision for manual operation: 250 Amps 4P, 415 VAC 50 Hz Make:-Havel’s / L&T/ ABB/Schneider/Siemens, 1 no. MCCB TP 250 Amps 36 kA Thermal Magnetic with adjustable Trip Setting for Overload and Short Circuit Protection Make:-Siemens/L&T/ABB/Schneider/ Havells, 1 No. CT 250 / 5 Amps Class : 0.5 for metering Make:- Kappa / AE , 1 No. CT 250 / 5 Amps for Power Factor Control Make:- Kappa / AE , 3 Set On / Off / Trip Indication Make:-L&T / ABB / Schneider , 1 No. CBCT based Earth Fault Protection System to trip the MCCB in case of Earth Fault , Make:- Havells / Siemens / Schneider / ABB / L&T
Replacement and refining with wiring Control consisting of following:- 1 No. Transformer 415 VAC / 220 VAC 500 VA Make:- Logicstat / Eq ,2 Nos. Control MCB DP 10 Amps Make:- Siemens/L&T/ABB/Schneider/ Havells , 1 No. Control On Indication Make:- L&T / ABB / Schneider
Replacement and refining with wiring Starter Section consisting of following:-60 HP Star / Delta Starter (1W + 1S) with following total material for both2 Nos. MCCB TP 36 kA Motor Duty Suitable for 60 HP Make:-Siemens/L&T/ABB/Schneider/ Havells, 4 Nos. Contactor TP 95 Amps AC3 Duty 220 VAC Make:- Siemens/Havells /L&T/ABB/Schneider , 2 Nos. Contactor TP 63 Amps AC3 Duty 220 VAC Make:- Siemens/L&T/ABB/ Havells /Schneider, 2 Nos. Thermal Over Load Relay 45-63 Amps Make:- Siemens/L&T/Havells /ABB/Schneider, 2 Nos. Single Phase / Phase Reversal Protection Make:- Minilec / L&T , 4 Set Start / Stop PB Make:- L&T / ABB / Schneider , 4 Set On / Off / Trip Indication Make:- L&T / ABB / Schneider , 4 Nos. Star / Delta Timer Make:- Siemens/L&T/ ABB/ Schneider/ Havells., 1 No. Contactor 16 Amps TP 230 VAC Make:- Siemens/L&T/ABB/Schneider/ Havells , 1 No. Over Load Relay 2.8 - 4 Amps Make:- Siemens/L&T/ Havells /ABB/Schneider , 1 No. Single Phase / Phase Reversal Protection Make:- Minilec / L&T , 2 Set Start / Stop PB Make:- Siemens/L&T/ABB/Schneider , 2 Set On / Off / Trip Indication Make:- L&T / ABB / Schneider/Havells
Replacement and refining with wiring Power Factor Section of 50 KVAR APFC System having Replacement:-1 No. MCCB TP 160 Amps Thermal Magnetic 36 kA for APFC section isolation Make:- Siemens/L&T/ABB/Schneider / Havells , 1 No. Microprocessor based APFC Relay 6 Steps Make:-Havells / L&T / ABB, 2 Nos. Capacitor Heavy Duty MPP 10 KVAR 415 VAC Make:-Havells / L&T / ABB 2 Nos. Capacitor Heavy Duty MPP 5 KVAR 415 VAC Make:-Epcos / L&T / ABB / Havells
Replacement and refining the all above material and reconnection the main line with all internal wiring and testing on full load
Goodwill Enterprises
INSTANT TRADE CORPORATION
S.T.ENTERPRISES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .