Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.9 LAccepted-AOC 790 STREET NO 1 PATEL NAGAR HISAR 125001 | HISAR | HISAR | HARYANA | 125001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹42.7 L+₹2.9 L (7.16%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹32.0 L
EMD Value
₹64,000
Closing Date
4 Jan 2020, 5:00 pmClosed
Lalit Mohan Jindal
Executive Engineer Elect. Division PWD B and R Hisar
Construction of 50 Beded to 100 Beded Hospital at Narnaund in Distt. Hisar (Pdg. E.I Internal only).
2019_HRY_113226_1
PWD/Elect-GGR/Elect-HSR/16774
Open Tender
Construction Works
Works
365 days
Hisar
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
Executive Engineer, Elect. Division PWD B and R Br
₹64,000
8 Dec 2020
19 Dec 2019
8 Jan 2020
20 Dec 2019
4 Jan 2020
20 Dec 2019
Amount
Main Switches: Supply and erection of metal clad switches / B.D.Bs with rag bolts on wall or on existing angle iron board / pedestal including bonding to earth and necessary connections. (HSR 31.12 (a). xiv) Triple pole switch with neutral link 32 amp. 415 Volts Cat-B.
xv) Triple pole switch with neutral link 63 amp. 415 Volts Cat-B.
xvi) Triple pole switch with neutral link 100 amp. 415 Volts Cat-A.
Molded case Circuit breakers.Supply and erection of molded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. (HSR 31.12 (c). i) 15 amp.to 60 amp. 415 V ,10 KA 3-phase.
ii) 100 amp.to 220 amp.415 V,10 KA 3-phase.
iii) 250 amp. 415 V , 35 KA 3-phase.
Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide. (HSR 31.13). ii) Size 40 mm x 40 mm x 6 mm.
M.S.Sheet (HSR 31.14) i) Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide.
Distrubution board with plug and socket: Supply and erection of sheet steel enclosure 2 pole / 3 pole with earth plug and socket suitable for incorporating single pole / triple pole MCB on wall / on existing pedestal complete with necessary connections etc. (HSR 31.15). ii) S.P.N. enclosure for single pole MCB 20 amp.
Blanking sheet (HSR 31.16) i) Supply and erection of blanking sheet in existing distribution board.
Miniature Circuit Breaker and Isolator: Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. (HSR 31.17) Miniature circuit breakers of 9 KA breaking capacity. ii) SP MCB 6 amp. to 32 amp.
TP MCB 6 amp. to 32 amp.
TP MCB 40 amp. to 63 amp.
TPN MCB 6 amp. to 32 amp.
TPN MCB 40 amp. to 63 amp.
Supply and erection of Fittings and Accessories (HSR 31.18) xi) Bakelite angle / straight button holder large size.
vii) Call bell 220 / 230 volts A.C. bakelite with double coil.
ix) Bell push flush type ( without flexible wire ) in existing sheet.
xxvi) Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5 cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild steel rod made into suitable suspension hook and erected in RCC slab for erection of fan , the bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete with all labour and material required to complete the job.
xxiv) Erection only of 1x40 watts or 2x40 watts 1220 mm long / 1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point.
xxviii) Supply and erection of lumineous bell indicator complete including making necessary connections and fixing the same on wall etc. to complete the job in all respect.
Erection and carriage of fans (HSR 31.20) i) Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work.
iii) Erection of exhaust fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to he site of work.
v) Making suitable hole in the wall upto 450 mm sweep exhaust fan including finishing the same and fixing of wire mesh duly fixed with Deodar wood frame of section 40 mm x 25 mm thick.
vi) Pdg. and fixing of required size of deodar wood frame of section 50 mm x 32 mm for fixing exhaust fan upto 450 mm sweep.
Pipe Laying: Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. (HSR 31.21). ix) Galvanised iron pipe 20 mm dia on flushed.
xxi) Heavy guage welded conduit pipe 20 mm dia 1.60 mm thickness flushed.
xxii) Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness flushed.
xxx) Supply and erection of PVC pipe of 6 kg. pressure laid 1 metre below ground level complete including digging refilling of the trench with jointing etc. c) PVC pipe 65 mm dia.
(Q) Earthing (HSR 31.22) i) Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required .
ii) Extra for using salt and charcoal / coke for pipe earth electrode as required.
iii) Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as equired.
iv) Earthing with tinned copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
v) Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode.
xi) Pdg. and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required .
xii) Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required .
xvi) Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required .
(b) Lightning conductor Galvanized iron (HSR 31.24). ii) Excavation of earth pit 180 cm. round at top and 90 cm. at bottom 4.5 metres deep and refilling the same in plains including supply of necessary charcoal / coke and salt mixture.
iv) Supply and erection of 60 cm. X 60 cm. X 6 mm thick galvanised Iron plate including nacessary bolts and nuts to G.I. tape.
v) Pdg. Standard watering tank including down pipe and C.I. cover with locking arrangement etc.
vi) Supply and erection of 20 mm x 3 mm thick lightning conductor G.I. tape fixed with suitable G.I. stapples of same size.
vii) Supply and erection of G.I. tape 32 mm x 6 mm thick from earth electrode directly in ground and surface , fixed with G.I. stapples of same size.
viii) Supply and erection of 25 mm dia meter 1.5 metre long lightning G.I. tube rod tapered in to a point at the top with 16 cm. X 16 cm x 3 mm thick G.I. base plate and necessary nuts and bolts with washer.
ix) Prioviding and fixing , testing joint made of 20mm x 3mm thick G.I. strips 125mm long with 4 Nos. G.I. bolts and nuits, check nuts with washer complete.
Supply and erection of underground cable ,loose in existing pipe or trenches complete with necessary connections. (HSR 31.26). xxvi) 35 Sq. mm 3.5 Core Ard. Cable.
xxvii) 50 Sq. mm 3.5 Core Ard. Cable.
xxviii) 70 Sq. mm 3.5 Core Ard. Cable.
xxxiii) 240 Sq. mm 3.5 Core Ard. Cable.
xxxix) 10 Sq. mm 4 Core Ard. Cable .
xl) 16 Sq. mm 4 Core Ard. Cable .
xli) 25 Sq. mm 4 Core Ard. Cable.
Bus Bar chamber (a) Copper: Supply and erection of metal clad bus bar chamber made from 1.6 mm thick M.S.sheet fixed with rag bolts on wall or on existing pedestal / angle iron frame including bonding to earth , detachable top and bottom painting and necessary connections etc.(Copper bars duly tinned ). (HSR 31.31) a) (xiv) 800 amp. 4 bars of 100 cm each (cross section 50 mm x 10 mm) chamber over all size 1.10 m x 70 cm x 38 cm .
Miscellaneous (HSR 31.35) i) Supply of M.S.pipe (B-Class) for suspension rod of ceiling fan including threading if required. b) 20 mm dia
iii) Supply and erection of caution notice plate in three languages.
iv) Supply and erection of shock restoration chart in glass frame
PVC Insulated wiring in recessed conduit. Wiring in 1.5 sqmm PVC insulated copper conduct cable in 1.6 mm thick conduit pipe. (HSR 31.36) i) Fan Point a) Short Point
b) Medium Point
c) Long Point
ii) Light Point a) Short Point
b) Medium Point
c) Long Point
iii) Twin Control Light point with 2 way, 5 amp. Single pole switch c) Long Point
vi) Call bell point including MS box of size 180mmx 60 mm deep for call bell. a)Short Point
c) Long point
vii) 3 pin 5 amp. Plug point including earthing the 3rd pin etc. a) Short Point
b) Medium Point
c) Long point
viii) 3 pin 15 amp. Plug point with 4 amp. PVC insulated copper conductor cable including earthing the 3rd pin etc. c) Long point
S/E of of PVC unsheathed copper conductor cable single core 1100 volts grad in pipe of suitable size excluding cost and erection of pipe. (HSR 31.40) i) Cable size 1.5 sqm(3/0.81 mm)
ii) Cable size 2.5 sqm(3/1.05 mm)
iii) Cable size 4 sqm(7/0.85 mm)
iv) Cable size 6 sqm(7/1.05 mm)
v) Cable size 10 sqm(7/1.35 mm)
S/E of double door sheet steel enclosure distribution board suitable for MCCb and ELCBs recessed in wall including bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-Charge of the work. (HSR 31.41) v) 4-way,TP&N (Horizontal)(8+12)
vi) 8-way,TP&N (Horizontal)(8+24)
vii) 12-way,TP&N (Horizontal)(8+36)
ix) 4-way,TP&N (Vertical)(8+12)
x) 8-way,TP&N (Vertical)(8+24)
S/E of PVC conduit pipe ISI marked (Medium) recessed in wall/ ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of the work. (HSR 31.44). b) 25mm dia
Supply & erection of Socket size rotary step type Electronic regulator for A.C. ceiling fan Anchor make Delux model No. 50440 ISI / SSK make PC 561 operated on 120/280 V A.C. Supply complete including cutting of existing Bakelite sheet and making necessary connection ect upto the entire satisfaction of the Engineer-in-Charge of the work. (HSR 31.55)
Supply installation testing and commissioning of wall/ free standing floor mounting dust and vermin proof compartmentalized cubical panel made out of 2mm thick CRCA street, required hardware 3 mm thick bakelite sheet provided all along with bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of zinc/ Red oxide primer followed by 2 coat of powder coating in gray or required shade after rising. The panel having PU/Neoprene rubber gasket of not less than 3 mm thickness separate detachable gland plate MS base channel hinged door with inter locking agreement for equipment / switch wear. Transparent acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3 mm thick for separately cable alley to BBC from switch chamber Extended solid copper bars upto cable alleys shall be provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. the panel will be complete with control wiring (copper) and fuse protection ( only outer area on all sides shall be measured) (HSR 31.63).
Supplying and fixing of copper bus bar duly tinned by means of SMC / BMC type insulatter high tensile nuts and bolts spring washer fixing to same in existing pannel including bending, cutting in required shape and size and insulation with colour coding heat shrinkable PVC insulation complete in all respect. (HSR 31.64).
Supply and fixing of rotary handle for on/off operation of existing MCCBs in the L.T panel including fixing the same in position with all labour and material required to complete the job in all respect.(HSR 31.66) i) Rotary handle upto 125 A MCCB
ii) Rotary handle above 125 A MCCB
Non Schedule items S/E of M.S. box for computer made of 16 guage of size 250mm x 200mm x 100 mm deep covered with 5 mm thick bakelite sheet white colour of ISI mark fixed by means of 4 nos .brass screws with cost of 1 No. 15 amp multi socket of ISI mark and 15 amp switch and 3 nos .5 amp multi socket with 5 amp switches of ISI mark including fixing the M.S. box in wall with cost of cement sand mixture including painting of M.S. Box and to complete the job in all respect upto the entire satisfatoin of Engineer-in- Charge of the work.
Supply / erection/ Testing / commissioning of 800 amp 4 pole 50 KA ACB MDO (Mannual draw out type) with microprocessor based release for over current, short circuit & earth fault in existing LT panel including labour charges complete in all respect upto the entire satisfaction of the Engineer-in Charge of the work.
Jayanti Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .