| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC | ₹34.8 L Quoted ₹35.0 L | L1 | Accepted-AOC ok |
| 2 | L2₹39.2 L+₹4.2 L (12.0%)Rejected-AOC 21 GURUKRIPA PATIL LAYOUT GOPLA NAGAR NAGPUR 440022 | NAGPUR | NAGPUR | MAHARASHTRA | 440022 | ₹39.2 L+₹4.2 L (12.0%) | L2 | Rejected-AOC ok |
Tender Value
Refer Docs
EMD Value
₹75,600
Closing Date
3 Oct 2020, 6:00 pmClosed
AGE(I)(P)(FY) AMBAJHARI
AGE(I)(P)(FY) AMBAJHARI ORDNANCE FACTORY AMBAJHARI NAGPUR 440021
SPECIAL REPAIRS TO BUILDING NO 25-A/IV.V, URC CANTEEN OF SQAE (A) CHANDRAPUR IN THE AREA OF JE B/R CHANDA UNDER AGE(I)(P)(FY) AMBAJHARI
2020_MES_374947_1
8482
Open Tender
Civil Works
Item Rate
180 days
AGE(I)(P)(FY) AMBAJHARI
As per tender documents
5 documents required · 5 mandatory
₹500
AGE(I)(P)(FY) AMBAJHARI
₹75,600
Yes
20 Nov 2020
5 Sept 2020
5 Oct 2020
5 Sept 2020
3 Oct 2020
21 Sept 2020
5 Sept 2020 - 18 Sept 2020
Amount
Dismantling of wall and ceiling boards of any description, any thickness including cover fillets complete all as specified and directed by Engineer- in -charge.
S&F for POP Gypsum Board ceiling (designer)12 mm thick fixed with following accessories complete all as specified and directed by Engineer- in -charge. (a) Gyproc ceilings designer boards. (b) Rawl plug 38mm x 12mm dia (c) Soffit cleat -1.6 mm thick (d) M6 Nut and bolt (e) Ceiling angle-25 x 10 mm (f) Perimeter channel- 20 mm x 28 mm x 30 mm all around. (g) Ceiling section @ 457 mm c/c. (h) Intermediate channel-15mm x 45 mm x 15mm x 0.9mm @ 1220 mm (i) Connecting clip- 2.64 mm dia (j) Edge bead -12.5/15 mm (k) Angle bead- 25 mm x 25 mm (l) Control joint @ every 10 m (m) Paper/Fiber tape & jointing compound (n) Dry wall screw - 3.5 x 25 mm (o) Metal to metal screw. (p) Any other accesories required. All accessories should be fixed as per manufacturer's instructions. Note :-For payment purpose, the net size of room i.e length x Breadth will be measured.
M & L for anodized aluminium snap grid frame work for false ceiling including 16 mm Non asbestos mineral fibre ceiling tiles of approved pattern fixed or laid /inserted to Aluminium framework with screws (In ceiling) of any size complete all as specified and directed by Engineer- in -charge.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings dressed stone work and precast concrete articles, complete all as specified and directed by Engineer- in -charge.
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed by Engineer- in -charge.
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick/concrete surfaces and finished even and smooth without using extra cement including taking down cement plaster of any description complete all as specified and directed by Engineer- in -charge.
M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick/concrete surfaces and finished fair and even incl taking down cement plaster of any description complete all as specified and directed by Engineer- in -charge.
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick/concrete surfaces and finished fair and even complete all as specified and directed by Engineer- in -charge.
Demolition of unreinforced concrete of any description and in any position complete all as specified and directed by Engineer- in -charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer- in -charge.
M & L for Vitrified Ceramic tiles 10mm thick (square/rectangular) polished, area of each tile exceeding 0.42 sq m but not exceeding1.00 sqm , in floors/Skirting etc set & jointed in neat cement slurry and pointed in white or coloured cement to match including over 15mm thick CM (1:6) screed bed or backing coat, spacer & grout all as specified and directed by Engineer- in -charge..
M & L for Cement concrete work in pavement/hard standing of flexural strength 40 Kg/Sqcm in field using 400 Kg of cement per cum, complete all as specified and directed by Engineer- in -charge.
M&L for cement concrete 1:4:8 Type D2 (using 40 mm graded aggregate) in foundation, filling and mass concrete complete all as specified and directed by Engineer- in -charge.
M&L for providing cement concrete 1:2:4 type B0 (using 12.5 mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed by Engineer- in -charge.
M & L for Type B0 1:2:4 (Using 12.5 mm graded aggregate) cement concrete for levelling of roof & provide suitable slope prior to roof treatment complete all as specified and directed by Engineer- in -charge.
Taking down door/window frames with shutters (without taking off ahutters from the frame) exc. 1.5 sqm but not exc.4 sqm each complete all as specified and directed by Engineer- in -charge.
S & F solid PVC door frame of size 50mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube, complete all as specified and directed by Engineer- in -charge.
S & F factory made PVC moulded door shutter 28 to 30 mm thick(stiles) with raised panel design with 2mm thick 3D wood grain moulded PVC sheet polyurethane painted on the front face & 2mm prelam PVC sheet on back face with parcticle board core complete all as specified and directed by Engineer- in -charge.
S & F stainless steel butt hinges 100mm long medium weight cold rolled complete all as specified and directed by Engineer- in -charge.
S & F 200mm long aluminum, anodized barrel tower bolts of extruded section complete all as specified and directed by Engineer- in -charge.
S & F aluminum anodised handles 150 mm long cast type complete all as specified and directed by Engineer- in -charge.
M&L for water proofing treatment in following stages:- 1. Taking down old cement plaster & treatment of any nature and rendering 15 mm thick in CM 1:3 with waterproofing liquid as per manufacturer's instruction over concrete surface finished even and smooth without using extra cement. 2. First coat of bitumen primer confirming to IS-3384@ 0.3 lit/Sqm over plastered surface.(Bitumen primer shall be TANK MASTIC of M/S STP Ltd or ‘EMW FLATE’ of M/S Texas India Ltd). 3. Third layer of APP polymeric water proofing membrane, mineral finish minimum 3mm thick and weighing not less than 3.5 Kg/Sqm with a centre core of 90 micron high density polyethylene film protected on both sides with a high quality polymeric asphaltic mix, the polymeric asphaltic mix will be protected on both sides with thermo fusable HMHDPE film as approved by AGE, black finish reinforced with non-woven polyester matt, with a thermo fusable finish.torching overlaps with a propane or a butane gas torch, with a overlap of 100mm at the sides and 150mm at the ends complete all as specified and directed by Engineer- in -charge
M&L for steel rolling shutters including top cover,Drum, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated complete, gear operated type with bevel gear box and crank handle, fully mechanised handle operated including all accessories and running channel including taking down old unserviceable steel rolling shutters complete all as specified and directed by Engineer- in -charge. (Net size of the rolling shutter including drum will be measured)
Demolition of reinforced cement concrete of any description and in any position complete all as specified and directed by Engineer- in -charge.
S & F aluminium powder coated sliding window made of the following specifications, complete all as specified and directed by Engineer- in -charge. :- (Net external size of window shall be measured. Following items are included in this unit rate.) (a) Aluminium frame powder coated all around of hollow section 100 mm x 44 mm x 1.60 mm thick. (b) Provn of 03 trade runners of size 92 x 31.75 x 1.10 mm. (c) Provn of glazed sliding shutters (02 Nos) of section 44 mm x 18 mm x 1.25 mm provided with 4 mm thick tinted glass with suitable EPDM beading and locking clips arrangement. (d) Provn of 01 No gauzed shutter of Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm with suitable EPDM beading and locking clips arrangement. Section of shutter as per para 25 (c) above. (e) Aluminium powder coated grill of weight not less than 2.60 Kg/Sqm on external side with suitable frame/aluminium runner to be fixed on the window frame.
S & F for Aluminium door chowkat hollow section frame aluminium powder coated of section 101.60 x 44.45 mm x 2 mm thick with necessary holdfasts/fastners and connected accessories fixed to wall openings with suitable fasteners/accessories complete all as specified and directed by Engineer- in -charge.
S & F for aluminium alloy powder coated starndard hollow section for door including following specifications incl 12 mm prelaminated particle board/12 mm thick PVC hollow sheet, or 5 mm thick tinted glass, snap type beads, glazing clips, joint cleats, rubber gasket etc and other accessories complete all as specified and directed by Engineer- in -charge:- (a) Bottom, middle and top rail made of section 100 x 44.45 mm of 2 mm thckness. (b) Stiles made of section 85 x 44,45 mm of 2mm thickness.
S&F 12 mm thick toughned glass door shutters fixed to wall/floor with suitable stainless steel pivot, handle, locking arrangement and all other accessories and the edges of the glass should be properly moulded/grinded complete all as specified and directed by Engineer- in -charge.
M&L for double action floor spring hydraulically regulated made up of min 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of MS heavy duty and fixed and hydraulic patch for glass doors complete all as specified and directed by Engineer- in -charge.
Dismantling of AC sheets(corrugated, semi corrugated etc) in roof coverings complete all as specified and directed by Engineer- in -charge.
S&F machine pressed Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of and colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with steel J-bolt and nut including washer and drilling to fix the J bolt, complete all as specified and directed by Engineer- in -charge.
S&F machine pressed Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of and colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with steel J-bolt and nut including washer and drilling to fix the J bolt, complete all as specified and directed by Engineer- in -charge.
M&L for 18 to 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform,WHB platform in any position including 15 mm thick screed bed in cement mortar (1:4) and pointing with white or coloured cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl dismantling/demolition of existing floors complete all as specified and directed by Engineer- in -charge.
Dismantling / taking out and removing existing unserviceable cement plaster, loose /unsound weaken cement concrete cover of any description and in any position from existing external surfaces of RCC roof slab/ beams /columns/ chajja and the like as directed roughening and cleaning concrete surfaces with steel wire brushes, washed with water and allowed to dry, incl derusting of steel reinforcement , providing fabric MS wire mesh 75 x 75 x 2 mm dia as reinforcement to concrete surfaces, applying adhesive/admixture over steel mesh and providing 40 mm thick (average thickness) guniting mix (using 1 part OPC 53 Gde and 02 parts of sand mixed with adhesive/admixture at the rate as directed with a pressure of 2 to 2.50 kg per sqcm by guniting machine and surfaces finished even and smooth incl necessary scaffolding/shuttering/form work & welding of steel reinforcement in columns, beams etc, complete all as specified and directed by Engineer- in -charge.
NOTES :- (a) Work is to be carried out in small stretches in different places (not at single place). (b) The cost of all scaffolding/formwork/safety measures or any thing else reqd to carry out the work will be included in this unit rate (except MS TMT Bars). (c) After fixing/welding the additional steel reinforcement all concrete surfaces shall be thoroughly scrubbed with brushes, washed with water and allowed to dry. To this surface apply chemistic polycrete admixture @ 2%by weight of cement or all as per manufacturer's instructions. (d) When polymix coating is in tackey condition guniting is done with polycrete admixture @ 2% by weight of cement or as per manufacturer's instructions. Polycrete admixture shall be procured from Chemical Adhesive Pvt Ltd Co or their authorised dealer only.
S & F aluminium powder coated ventilators made of the following specifications complete all as specified and directed by Engineer- in -charge.:- (Net external size of ventilator shall be measured. Following items are included in this unit rate.) (a) Aluminium frame powder coated styles, bottom, top and middle rail of hollow section 50 mm x 25 mm x 1.80 mm thick. (b) Lower portion of ventilator shall be fixed with 3 mm thick pin headed glass fixed with suitable aluminium beading clips and EPDM beading (rubber). (c) Upper portion shall be fixed with aluminium powder coated louver guides fixed with 3 mm thick pinheaded glass with suitable EPDM beading incl suitable handle and clips. (d) Aluminium powder coated grill of weight not less than 2.60 Kg/Sqm on external side with suitable frame/aluminium runner to be fixed on the ventilator frame. (e) Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with suitable frame in upper panel.
S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top hoisted and fixed in position including dismantling existing water tank and removing to store etc and including tank connection nipples and float valve 20 mm dia complete all as specified and directed by Engineer- in -charge.
S&F 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top hoisted and fixed in position including dismantling existing water tank and removing to store etc including tank connection nipples and float valve 20 mm dia complete all as specified and directed by Engineer- in -charge.
Dismantling of aluminium partitions of extruded hollow section,particle board and glass of any thickness and refixing at other places by providing suitable accessories (like EPDM,Rubber beading, Screwing, fastners etc.) complete all as specified and directed by Engineer- in -charge.
M & L for 75mm thick PCC 1:3:6 type C-2 (40 mm graded aggregate as in plinth protection) complete all as specified and directed by Engineer- in -charge.
S & F for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, angle iron chowkhats; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0, complete all as specified and directed by Engineer- in -charge.
M&L for preparation of new steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer- in -charge.
M&L for complete removal of exisiting treatment to steel and iron surface of any description over 10 cm width or girth not other wise described and applying two coats of synthetic enamel paint over a coat of red oxide primer including easening of steel window by providing lubricant oil to hinges/pivot complete all as specified and directed by Engineer- in -charge.
M&L preparation of old painted surfaces of wood and wood based surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer- in -charge.
M&L for applying two coats of plastic emulsion paint (newly plastered surfaces)over a coat of alkali resistant primer over wall care putty 2 mm thick or more as required to level the wall surface complete all as specified and directed by Engineer- in -charge.
M&L for complete removal of existing treatment of old surfaces of wall by brooming down or steel wire brushing, scrapping down smoke, efflorescent salts, oil, greesy spot or peeled off surfaces and applying a layer of Birla white putty 2mm thick even and smooth and applying two coats of plastic emulsion paint (approved quality & tint) over a coat of alkali resistant primer using painting rollar complete all as specified and directed by Engineer- in -charge.
Ditto all as per item No.44 herein before but on ceiling complete all as specified and directed by engineer in charge.
M& L for applying two coats of cement base paint (approved colour and tint) over a coat of primer including preparation of newly plastered surfaces on walls etc complete all as specified and directed by Engineer- in -charge.
M&L for complete removal of existing treatment of old surfaces of wall by brooming down or steel wire brushing, scrapping down smoke, efflorescent salts, oil, greesy spot or peeled off surfaces and applying two coats of cement base paint (approved colour and tint) over a coat of primer etc complete all as specified and directed by Engineer- in -charge.
S&F Joist, Channels, angle or tee sections, fixed independently without connecting plates etc (cut to ordinary lengths) conforming to Fe 410W (Gde E250) complete all as specified and directed by Engineer- in -charge. (The joists/channels are being provided as supporting beam for the depleted roof slabs of old vintage)
S&F in repair wooden designed frame looking mirror of size exc 1.00 Sqm and n exc 3 Sqm, bevelled edge 5.5mm thick high quality glass,dual hanging option & fixed to wooden plug with CP brass screws and cup washers complete all as specified and directed by Engineer- in -charge.
S&F in repair medium grade galvanised steel tubes with all fittings and fixed complete to walls and ceilings or laid in floors, bore of tubes 15mm complete all as specified and directed by Engineer- in -charge.
S & F in repair 110mm dia PVC (SWR) pipe single socketed in any length including all Tees and bends with rubber ring joints fixed to walls complete all as specified and directed by Engineer- in -charge.
M&L for preparation of new steel surfaces of any description over 10 cm in width and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer- in -charge.
S & F collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., erected in position and securing runners with holdfasts and brackets including taking down old unserviceable collapsible steel gate complete all as specified and directed by Engineer- in -charge.
S&F 4 mm thick Aludecor ACP sheeting having coil thickness 0.50 mm coloured as per approved colour using steel cleat, frame, sealing and backup material complete all as per manufacturers instruction and all as specified and directed by Engineer- in -charge.
S&F SS letters (English/Hindi) consisting of 200 mm high, 50 mm wide and 25 mm deep (hollow) and 1 mm thickness fixed on wall/ACP or surface of any description all as specified and directed by Engineer- in -charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer- in -charge. Note:- The damaged surfaces to be made good with plastering (1:6). & applying colour wash in required coats to matching with existing surfaces as directed by Engineer-in-charge. Cost of the same deemed to be included in coated rates & nothing extra on this account admissible.
Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as switches,sockets, ceiling roses, lamp holders, brackets, and regulators, etc. for taking scedule of credit complete all as specified and directed by Engineer- in -charge.
Taking down carefully old Distribution Board any type / any size including SP/TP switches fuse unit and all connected accessories. Dismantling carefully electric meter and keep in safe custody for reuse complete all as specified and directed by Engineer- in -charge. Note:- (a) The damaged surfaces to be made good with plastering (1:6). & applying colour wash in required coats to matching with existing surfaces as directed by Engineer-in-charge. Cost of the same deem to be included in quoted rates and nothing extra on this account admissible.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store etc complete all as specified and directed by Engineer- in -charge.
Taking down split AC of capacity 1.5 TR to 2 TR inner unit and outer unit storing refrigerant in compressor of split AC disconnecting electrical cable and copper refrigerant pipe and depositing in store complete all as specified and directed by Engr-in-Charge.
M & L for point wiring (concealed) complete with FR PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic medium grade rigid PVC conduit medium grade, ISI marked, 20 mm dia including all accessories, concealed in walls/floors/ceilings etc by cutting chases using machine and making good the disturbed surface by using putty and white/colour wash, with and including suitable modular metal boxes, and 1.5 sq mm FR copper earth continuity wire connected to earth dolly complete for the following complete all as specified and directed by Engineer- in -charge. Note:- [i] Proper colour code will be used for wiring as per the electrical rule and as directed by Engineer In Charge. [ii] Modular metal box and Modular white cover plate shall be measured and paid separately.
One light point (or) one ceiling fan/Exhaust fan controlled by one, one-way switch, SP, 6 Amps.
One switch socket outlet, 3 pin, 5 Amp, 230 volt flush type on independent board.
One socket outlet, 3 pin, 5 Amp, 230 volt flush type on same board.
Ditto all as per item No.62 herein before but with 4 sqmm cable for one 3 pin 15 Amp switch socket outlet and using 2.5 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified and directed by engineer in charge.
Disconnecting existing fluorescent tube light fitting 2'x2' from ceiling and supply and fixing new ceiling light fitting 2'x2' fully diffused recessed Mounted 2'X2' LED luminaire with UGR <19, offering comfortable experience to occupants of indoor spaces etc complete all as specified and directed by Engineer- in -charge. Type RC380B LED30S -6500 G4 L60 W60 PSU OD OC 9405 of Philips or equivalent in Wipro/Crompton Greaves.
Dismantling old fitting & Supply and fixing Street Light fitting 20 watt, GreenLine Smart luminaire with IP66 protection, clear white is perfect for secondary roads and pathways/bldg security lights complete all as specified and directed by Engineer- in -charge. Cat No : BRP022 LED 20 CW MR S1 PSU GR Make Philips or equivalent in Wipro/Crompton Greaves.
Dismantling old fitting & Supply and fix LED batten light fitting, 20W LED 6000K (4ft), with extruded aluminium heat sink, control gear , poly corbonate extruded diffuser & integrated electronic driver. 230 V etc. complete with all accessories internally pre-Wired and including connecting up with three core sheathed copper cable 1.5 sqmm complete all as specified and directed by Engineer- in -charge. Cat No BN 021C LED20S PSU CW GR S2 Make : Philips or equivalent in Wipro /Havells.
Hanging only ceiling fan (Ceiling Fan retrieved from Item No.60) and connecting up including provision of cable from ceiling rose to fan complete all as specified and directed by Engineer- in -charge.
Fixing only exhaust fan of any description or size ( Exhaust Fan retrieved from Item No.60) and connecting up including provision of cable from ceiling rose to fan complete all as specified and directed by Engineer- in -charge.
Installation of split AC of capacity 1.5 TR to 2 TR inner unit and outer unit(retrieved from item No 61) including electrical connection and copper pipe from compressor to AC inner unit including recharging of refrigerant if required and testing the split ACs upto the entire satisfaction of the user complete all as specified and directed by Engineer- in -charge.
S&F Fan step regulator, 120 W, 2 Module, etc complete all as specified and directed by Engineer- in -charge.
S&F modular white cover plate with frame for mounting switches, socket outlets, regulators, etc suitable for modular metal boxes complete all as specified and directed by Engineer- in -charge for the following sizes :
1 moudle
2 modules
3 modules
4 modules
6 modules
8 modules
12 modules
S&F modular metal flush boxes for mounting plate with frame for switches, socket outlets, regulators, etc suitable for modular metal boxes complete all as specified and directed by Engineer- in -charge for the following sizes :
1 moudle
2 modules
3 modules
4 modules
6 modules
8 modules
12 modules
S&F modular switch 1 way, 6 Amps 1 module etc complete all as specified and directed by Engineer- in -charge.
S&F modular switch 1 way, 16 Amps 1 module etc complete all as specified and directed by Engineer- in -charge.
S&F modular socket outlet ,6 Amps 2/3 pin combined 2 module etc complete all as specified and directed by Engineer- in -charge.
S&F modular socket outlet ,6/16 Amps 2/3 pin combined 2 module etc complete all as specified and directed by Engineer- in -charge.
S&F Modular blank plate for switches, 01 module etc complete all as specified and directed by Engineer- in -charge.
S&F ceiling rose, surface bakelite, 65x50mm size three terminals ISI marked etc complete all as specified and directed by Engineer- in -charge.
M & L for lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings etc etc complete all as specified and directed by Engineer- in -charge.
S & F in repairs sub main wiring with 2 runs of 6 sqmm single core 1100 volts grade, PVC sheathed and PVC insulated, copper conductor multistranded drawn through and including PVC conduit 25 mm dia medimum grade ISI marked including fittings accessories fixed on walls/roofs/ceiling etc. including one run of PVC insulated 4 sqmm multistranded copper earth continuty conductor from main DB to sub main DB etc complete all as specified and directed by Engineer- in -charge. Note:- (1) Two runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as unit length. (2) The damaged surfaces to be made good with plastering (1:6), 3 coats of colour wash matching with existing surfaces as directed by Engineer In Charge will be carried out by contractor and cost of the same deem to be included in the quoted rates. Nothing extra in this account will be admissible.
S & F in repairs sub main wiring with 2 runs of 4 sqmm single core 1100 volts grade, PVC sheathed and PVC insulated, copper conductor multistranded drawn through and including PVC conduit 20 mm dia medimum grade ISI marked including fittings accessories fixed on walls/roofs/ceiling etc. including one run of PVC insulated 2.5 sqmm multistranded copper earth continuty conductor from main DB to sub main DB etc complete all as specified and directed by Engineer- in -charge. Note:- (1) Two runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as unit length. (2) The damaged surfaces to be made good with plastering (1:6), 3 coats of colour wash matching with existing surfaces as directed by Engineer In Charge will be carried out by contractor and cost of the same deem to be included in the quoted rates. Nothing extra in this account will be admissible.
S & F in repairs sub main wiring with 4 runs of 10 sqmm single core 1100 volts grade, PVC sheathed and PVC insulated, copper conductor multistranded drawn through and including PVC conduit of suitable dia medimum grade ISI marked including fittings accessories fixed on walls/roofs/ceiling etc. including 2 run of PVC insulated 6.00 sqmm multistranded copper earth continuty conductor from main DB to sub main DB etc complete all as specified and directed by Engineer- in -charge. Note:- (1) Four runs of cable, two run of earth continuity conductor and one run of PVC conduit shall be measured as unit length. (2) The damaged surfaces to be made good with plastering (1:6), 3 coats of colour wash matching with existing surfaces as directed by Engineer In Charge will be carried out by contractor and cost of the same deem to be included in the quoted rates. Nothing extra in this account will be admissible.
Supply and fix TPN DB-VTPN DPX³ 160 MCCB distribution board double door type, TPN 8 way (for incoming MCCB & outgoing MCBs), as per IEC 61439-3 , suitable for Flush Mounting and Surface Mounting, with 250 A Copper Busbar for each phase, with 2 Neutral bar, 2 Earth bar and Cable ties for Cable management, fully insulated busbar & shrouded Neutral bars, Improved Pan assembly for ease of installation, prefitted masking sheet, Reversible Door for IP 43 and IK 9 with metal door DB's with provision for DPX³ 160 MCCB as incomer and SP/TP MCB's as outgoing etc complete all as specified and directed by Engineer- in -charge. Cat No : 5077 47 Make ; Legrand or equivalent in L&T/Havells
S&F, DB, SPN, 12 way with suitable bus bar, double door etc complete all as specified and directed by Engineer- in -charge. Make : Schneider/L&T/Legrand.
S&F, TPN DB, 4 way, with 200 amps bus bar, double door etc complete all as specified and directed by Engineer- in -charge. Make : Schneider/L&T/Legrand.
S&F, DB, SPN, 4 way with 200 amps bus bar, double door etc complete all as specified and directed by Engineer- in -charge. Make : Schneider/L&T/Legrand.
S&F MCCB 4 pole, 415 volts, DPX3 250 thermal magnetic series, 160Amp , having breaking capacity 25KA, etc etc complete all as specified and directed by Engineer- in -charge. Cat No : 4202 17 Make : Legrand or equivalent in Schneider/L&T.
S & F MCB TP. 40-63 Amps 'C' series, breaking capacity 10 Ka, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. etc complete all as specified and directed by Engineer- in -charge. Cat No 4086 59 Make : Legrant or equivalent in L&T/Havells
S & F MCB TPN. 40-63 Amps 'C' series, breaking capacity 10 Ka, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. etc complete all as specified and directed by Engineer- in -charge. Make : Legrant or equivalent in L&T/Havells
S & F MCB SPN, 6 to 32 Amps, C series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. etc complete all as specified and directed by Engineer- in -charge. Cat No : 4086 15. Make : Legrand or equivalent in L&T/Havells
S & F MCB SP, 6 Amps to 32 Amps, C series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. etc complete all as specified and directed by Engineer- in -charge. Make : Legrand or equivalent in L&T/Havells
Supply and fix time switch Alpha Rex3 D21 astro, 1 channel, for switching on/off lights and other electric devices according to the rising/setting of the sun. with combination function for creating switching programs in which the devices are switched according to astronomical time and/or fixed preset times 250 V single, Phase of 20 Amp rating with contactor fitted inside steel enclosure, etc etc complete all as specified and directed by Engineer- in -charge. Cat No 4126 54 Make : Legrand or equivalent in L&T/Schneider.
S & F Blanking plate for DB complete all as specified and directed by Engineer- in -charge. Cat No 6014 70 G Make Legrand or equivalent in L&T/Schneider.
M & L for galvanised iron pipe, light grade, with all fittings of size 40mm bore complete laid in road crossings/on poles/walls/in floors for cable protection etc complete all as specified and directed by Engineer- in -charge.
M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engineer- in -charge.
S & F Motor starter 25 A, 02 Module, etc complete all as specified and directed by Engineer In Charge. Make :- Legrand Cat No. 673031 or equivalent in L&T,HPL
S&F sheet metal enclosures single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 240V, 20 Amps etc all as specified and directed by Engineer- in -charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size size 95 sq mm 3½ core etc complete all as specified and directed by Engineer In Charge
Supply and fix GreenLED Ultima Ultra Sleek recessed downlight for low height false ceiling in round profile. Of 10.Watt.etc complete all as specified and directed by Engineer In Charge. Cat No. DN092B LED10S-6500 PSU WH Make Philips or equivalent in Wipro/Crompton Greaves
Supply and fix sky cove LED strip, 5 mtr strip especially designed for commercial use including driver in pack, 24 watt output in 3000K etc complete all as specified and directed by Engineer In Charge
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1TR complete all as specified and directed by Engineer In Charge. Make : Daikin/Hitachi/Mitsubishi.
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volts to 250 volts with output voltage stabilizer at 230 voltage with accuracy of +- 2.5% and of capacity 3KVA complete all as specified and directed by Engineer In Charge.
Supply, installation, commis-sioning of Water cooler fully stainless steel, electric driven single phase having approx storage capacity 40 ltrs and nominal cooling capacity 20 ltrs per hour.
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volts to 250 volts with output voltage stabilizer at 230 voltage with accuracy of +- 2.5% and of capacity 2KVA etc complete all as specified and directed by Engineer In Charge.
Supply and erection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 meters long) including painting of pole with black bituminous paint internally and upto 1.5m from bottom level externally and two coats of aluminium paint over a coat of red oxide parimer externally complete all as specified and directed by Engineer In Charge.
Sypply and fix street light fitting 40 watt, CW GreenLine is an IP66 road lighting luminaire with high power LED and unique peanut lens to ensure uniform light distribution, higher spacing between poles and maintenance free system complete all as specified and directed by Engineer In Charge. Cat No : BRP409 LED 040 CW HO MR FG S1 PSU GR Make : Philips or equivalent in Wipro/Havells
Supply and lay PVC insulated PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded Copper conductor of size 2.5 sq mm 2 core 1100 Volts grade (junction box to street light) confirming to IS : 7098 (Pt-1) 1988 etc complete all as specified and directed by Engineer In Charge. Make : Polycab/Havells/Finolex
M & L for cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm, 2 core laid in trenches/drawn through pipes/ fixed to walls/ laid on floors etc complete all as specified and directed by Engineer In Charge.
Supply and fixing Thermoplastic polycorbonate street light pole Cable Junction Boxes IP 66 “halogen free and weather proof” for outdoor installation (with metric knockouts for cable entryof size 167 x 125 x 82 for cable entry 10 sqmm cable including all accessories required . - Black Colour complete all as specified and directed by Engineer In Charge. Cat : KF 5105 . Make : HENSEL/Syntex.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion etc all as specified and directed by Engineer In Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide and getting out complete all as specified and directed by Engineer In Charge.
Excavation in trenches in soft/loose soil exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide and getting out complete all as specified and directed by Engineer In Charge.
Supply and spread clean dry sand in trenches 8cm below the cable and 15cm above the cable, levelled and punned down to 18cm for cushioning of cable complete all as specified and as directed by Engineer In Charge.
Returning and filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm complete all as specified and as directed by Engineer In Charge.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point in rocks complete all as specified and as directed by Engineer In Charge.
Supply and laying in trenches un reinforced pre cast concrete cable covers, class-LV, type-I, flat size 250mm X 150mm X40mm thick confirming to IS-5820-1970 complete all as specified and as directed by Engineer In Charge.
M & L plain cement concrete type C1, 1:3:6 (20mm graded stone aggregate) for coping of poles including necessary form work complete all as specified and as directed by Engineer In Charge.
Asha Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .