Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.1 L+₹39,993 (2.54%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹16.2 L+₹46,861 (2.98%)Rejected-Finance 22 319 GALI NO 5 MAHABIR PARK BAHADURGARH 124507 HARYANA | JHAJJAR | HARYANA | 124507 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹16.3 L+₹61,405 (3.91%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹17.4 L+₹1.7 L (11.0%)Rejected-Finance 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
7 Apr 2025, 6:00 pmClosed
CWE
HQ CWE NO 2 DELHI CANTT-10
REPAIR / REPLACEMENT OF OLD WIRING, SUB MAIN WIRING, DBs, LED LIGHTS AND OTHER FITTING FIXTURES AT RESTRICTED AREA UNDER GE SOUTH WEST NEW DELHI-03
2025_MES_701526_1
CWE/SW/TOKEN-55/2024-25
Limited
Electrical and Maintenance Works
Item Rate
180 days
RESTRICTED AREA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE SOUTH WEST NEW DELHI
₹48,000
31 May 2025
17 Mar 2025
9 Apr 2025
17 Mar 2025
7 Apr 2025
31 Mar 2025
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Taking down old UNSV recess/ surface type distribution board SP/SPN type from wall etc
Taking down old UNSV recess/ surface type distribution board TPN type from wall etc
M&L for point wiring for light/fan for Modular Switches or normal switches with 2 x 1.5 sqmm, Single core sheathed, FRLS, multistranded copper conductor PVC insulated cable 1100 Volts grade, drawn through concealed rigid non-metallic PVC conduit with all standard fittings of suitable size as required at Site including cadmium plated screws as per IS and replacement of top modular cover plate/face plate cover, CI/GI sunken boxes/terminal boxes etc concealed in any type of wall including 1.5 sqmm size PVC insulated Copper earth continuity conductor and connected to common earth dolly for one light/fan point controlled by one switch 5 Amps one way Single pole complete all as specified and directed.
All as per item No. 4.00 above but one three pin 5 Amps socket out let on independent board.
All as per item No. 4.00 above but one three pin 5 Amps socket out let on same board.
All as per item No. 4.00 here-in-before but point wiring of Copper Conductor multistranded 2x2.5 Sqmm size for 3 pin 15 Amps socket outlet on independent board with 2.5 sqmm size of earth conductor complete all as specified and directed.
S & F modular Switch Single module 6 Amp, complete all as specified and directed.
S&F Modular switch single module pole 16 amps complete all as specified and directed.
S&F modular socket outlet 2-in-1, 3 pin ,6&16 Amp , ,two module complete all as specified and directed.
S&F modular socket outlet 2-in-1, 3 pin ,6 Amp , two module, complete all as specified and directed.
S&F modular step type fan regulator 120 watt, two module socket type complete all as specified and directed.
Supply and fixing modular switch Bell push 6 Amp 230 volt, one module complete all as specified and directed.
Supply and fixing in replacement 6 Amp, 2-in-1 switch and Socket with combined box 3 module complete all as specified and as directed.
Supply and fixing in replacement of 16 Amp & 6 Amp, switch socket combined unit PVC box, complete all as specified and as directed.
S&F ceiling rose, 6 Amps, 250 volts, AC with three terminals and PVC / Polycarbonate insulated body of 50 x 25mm size ,complete all as specified and as directed.
Supply and fixing in replacement step type electronic fan regulator , flush type complete all as specified and directed.
Supply and fixing in replacement of modular step type fan regulator 100 watt, switch type one module, complete all as specified and directed.
Supply and fixing in replacement of socket out let 2-in-1 pin 5 Amps complete all as specified and as directed.
Supply and fixing in replacement of modular socket outlet 2-in-1, 3 pin ,6 Amp , flush type complete all as specified and as directed.
Supply and fixing in replacement modular switch 6 Amp, 2 way 230 volt complete all as specified and as directed.
Supply and fixing in replacement buzzer, ding dong bell, AC, 230 volts, Single pole complete all as specified and directed.
Supply and fixing in replacement of modular white cover with frame 12 modules (2x6 module) suitable for fixing of modular Switches/sockets complete all as specified and directed.
Supply and fixing in replacement of modular white cover plate with frame 8 modules (2x4 module) suitable for fixing of modular Switches/sockets , complete all as specified and directed.
Supply and fixing in replacement of modular white cover plate and with frame 6 module suitable for fixing of modular Switches/sockets complete all as specified and directed.
Supply and fixing in replacement of modular white plate and cover suitable for fixing of modular Switches/sockets , 3 modules complete all as specified and directed.
Supply and fixing in replacement lamp holder, 230 volt AC, PVC / Polycarbonate type with back plate suitable for batten fitting complete all as specified and directed.
Supply & Fixing in replacement of sheet metal enclosure with socket plug top , single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP 25Amp of capacity 20P+E Amps complete and making good disturbed surface all as specified and directed.
Supply and fixing in replacement of Modular metal flush box suitable for fixing of modular Switches/sockets of 3 modules complete all as specified and directed.
Supply and fixing in replacement of Modular metal flush box suitable for fixing of modular Switches/sockets of 4 modules complete all as specified and directed.
Supply and fixing in replacement of Modular metal flush box suitable for fixing of modular Switches/sockets of 6modules complete all as specified and directed.
Supply and fixing in replacement of premium quality Red/ Green 0.5 watt LED light 220/240 Volt complete all as specified and directed.
S&F MCB DB, Single pole and neutral with 200 Amps rated bus bar, 230 volts, glazed, double door type, IP-43, including connecting all connections of wire to MCBs with proper lugs & making good to the disturbed surface complete for the following no of way :-
S&F distribution box 4 way, AC, TP & neutral metal enclosure, Glazed double door, 415 V, AC, IP-43, concealed type with suitable bus bar, neutral link, earth link suitable for MCB 63/100 Amps TPN as incomer and MCB SP as out going complete and making good disturbed surface complete all as specified and directed.
S&F distribution box8 way, AC, TP & neutral metal enclosure, Glazed double door, 415 V, AC, IP-43, concealed type with suitable bus bar, neutral link, earth link suitable for MCB 63/100 Amps TPN as incomer and MCB SP as out going complete and making good disturbed surface complete all as specified and directed.
Supply and fixing in replacement MCB DP/SPN, 240 Volts, AC of breaking capacity 10 KA, 'C' curve and connections by using suitable copper lugs complete of following rating :-
M&L for earthing with Galvanised Steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 meter below normal ground level, earth plate surrounded from all Sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using GI wire of size 4mm dia as earthing lead (upto the body of the equipment) by means of GI bolts, nuts, check nuts and washers and thimbles and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 2010 (Part-I) complete all as specified and directed.
Taking down carefully electric geyser of any type and capacity by disconnecting electric and water supply connection, opening nut, bolt, washer and reassembling after cleaning and replacing defective parts and re-installing the same in original position and making necessary electric and water supply connection and testing complete all as specified and directed. Note: Spare items shall be measured and paid separately
M&L for dismantling of unsv Ceiling Fan of any make/model/sweep for repair and refixing the same after repair, complete all as specified and directed.
M&L for dismantling of unsv exhaust fan upto 300mm sweep Size, complete all as specified and directed.
M&L for dismantling of unsv exhaust fan of 380/450mm sweep size, complete all as specified and directed.
M&L in repair ball bearing suitable for any type/Size/make of Exhaust Fan complete all as specified and directed.
S&F in repair capacitor 2.5/3.15 MFD suitable for C/fan incl connection complete all as specified and directed.
Supply and fixing steel fan blade assembly suitable for Exhaust fan 300 mm sweep complete all as specified and directed.
S&F geyser inner water tank 35/50Ltrs capacity steel body as per sample, duly tested complete all as specified and directed.
All as per item No. 45 above but 25 Ltrs capacity complete all as specified and directed.
S&F heating element capacity 1.5 KW (Round/Triangular) ISI marked suitable for geyser (as per sample approved by GE) complete all as specified and directed.
All as per item No. 47 above but capacity 2 KW
S&F thermostat suitable for 50/35/25 ltrs capacity geysers complete all as specified and directed.
S&F Heavy duty hot water connection pipe, SS rope threaded type with brass unions at both ends, 45cm long 15mm bore suitable upto 96 degree Centigrade temp, complete all as specified and directed.
S&F indicator lamp, Red/Green suitable for geyser of any type/capacity (as per sample approved by GE) complete all as specified and directed.
S&F geyser base plate assembly in stainless steel of any type(having 6 or 9 hole) any model (as per sample approved by GE) complete all as specified and directed.
S&F in replacement of outer cover of MS sheet/ABS body for geysers 25 to 50 Ltrs capacity complete all as specified and directed.
S&F in repair Plug top, 3 pin, 05 amps, 230 volt complete all as specified and directed.
S&F in repair Plug top, 3 pin, 15 amps, 230 volt complete all as specified and directed.
Cutting and removing the old defective/burnt winding, cleaning the core of ceiling fan motor and rewinding the fan motor with super enameled copper winding wire of same gauge with insulating material and varnishing the core assembly, drying the moisture content to get appropriate speed and re-assemble the same complete all as specified and directed. Note :- The cost of copper winding wire is deemed to be included in the quoted rate
All as per above item no 56 but for exhaust fan upto 300mm sweep size complete all as specified and directed.
All as per above item no 56 but for exhaust fan of 380/450mm sweep size complete all as specified and directed.
M&L in repair ball bearing suitable for any type/size/make of Ceiling fan/ Exhaust Fan complete all as specified and directed.
S&F (in replacement) following MCCBs in the existing panel / location and connection with using aluminum lugs incl making necessary alteration in panel/door as required for proper fixing & connection complete all as specified and directed.
Isolator 4 pole 63 amps, 10 KA breaking capacity, B'' Series, 415 Volt
Isolator 4 pole 100 amps, 10 KA breaking capacity, B'' Series, 415 Volt
MCCB 3 pole 63 amps, 16 KA breaking capacity, 415 Volt
MCCB 3 Pole 100 amps, 16 KA breaking capacity, 415 Volt
MCCB 3 Pole 125 amps, 25 KA breaking capacity, 415 Volt
MCCB 3 Pole 200 amps, 35/36 KA breaking capacity, 415 Volt
MCCB 4 Pole 200 amps, 35/36 KA breaking capacity, 415 Volt
MCCB 3 Pole 250 amps, 35/36 KA breaking capacity, 415 Volt
MCCB 4 Pole 250 amps, 35/36 KA breaking capacity, 415 Volt
MCCB 3 Pole 400 amps, 35/36 KA breaking capacity, 415 Volt
MCCB 4 Pole 630 amps, 36/50 KA breaking capacity, 415 Volt
Volt meter (0 to 500 volts) digital type, three phase of size 96mm x 96mm
Amp meter (0 to 300 amps) digital type, three phase of size 96mm x 96mm
Indicator lamp, LED type
M & L in replacement of Sub Main wiring with 2 x 2.5 Sqmm Single core, multistranded copper conductor FRLS PVC insulated cable 1100 Volts grade, including suitable size of PVC conduit recessed in any type of wall or clamped on surface at RCC portions etc including 2.5 Sqmm size PVC insulated copper earth continuity conductor to common earth and connecting to earth dolly for AC/Power point including drilling holes and making good to disturbed surfaces to match with existing surfaces complete all as specified and directed.
M & L in replacement of Sub Main wiring with 2 x 4 Sqmm Single core, multistranded copper conductor FRLS PVC insulated cable 1100 Volts grade, including suitable size of PVC conduit recessed in any type of wall or clamped on surface at RCC portions etc including 4 Sqmm size PVC insulated copper earth continuity conductor to common earth and connecting to earth dolly for AC/Power point including drilling holes and making good to disturbed surfaces to match with existing surfaces complete all as specified and directed.
M & L in replacement of Sub Main wiring with 2 x 6 Sqmm Single core, multistranded copper conductor FRLS PVC insulated cable 1100 Volts grade, including suitable size of PVC conduit recessed in any type of wall or clamped on surface at RCC portions etc including 6 Sqmm Size PVC insulated copper earth continuity conductor to common earth and connecting to earth dolly for AC/Power point including drilling holes and making good to disturbed surfaces to match with existing surfaces complete all as specified and directed.
M & L in replacement of Sub Main wiring with 2 x 10 Sqmm Single core, multistranded copper conductor FRLS PVC insulated cable 1100 Volts grade, including suitable size of PVC conduit recessed in any type of wall or clamped on surface at RCC portions etc including 10 Sqmm size PVC insulated copper earth continuity conductor to common earth and connecting to earth dolly for AC/Power point including drilling holes and making good to disturbed surfaces to match with existing surfaces complete all as specified and directed.
M & L in replacement of Wiring for circuit/sub main wiring with 2 x 1.5 Sqmm Single core, wiring along with earth multistranded copper conductor FRLS PVC insulated cable 1100 Volts grade, including suitable size of PVC conduit recessed in any type of wall or clamped on surface at RCC portions etc including 1.5 Sqmm size PVC insulated copper earth continuity conductor to common earth and Single core cable in recessed as required surface complete all as specified and directed.
S&F in replacement LED surface mounted1x1ft (300x300x70) mm luminaries fitting LED 34/36 Watt cast aluminium housing, toughened glass, silicon gasket, 4000K high power LED with lens for uniform distribution pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire including clamps and nut bolts for fixing complete all as specified and directed.
S & F in replacement of energy efficient LED Round shape surface mounted down light fitting 15 to 18 Watt,230 Volt of 6000 K cooler temp ,decorative ultra slim linear LED lighting fixture with extruded Al. heat Shrink, environmental friendly, energy efficient, wall mounted batten integrated electronic driver complete all as specified and directed.
M & L in replacement of Sub Main wiring with 4 x 10 Sqmm Single core, multistranded copper conductor FRLS PVC insulated cable 1100 Volts grade, including suitable size of PVC conduit recessed in any type of wall or clamped on surface at RCC portions etc including 10 Sqmm size PVC insulated copper earth continuity conductor to common earth and connecting to earth dolly for AC/Power point including drilling holes and making good to disturbed surfaces to match with existing surfaces complete all as specified and directed.
S&F in replacement LED surface mounted 4x1ft (1195x295x65)) mm luminaries fitting LED 34/36 Watt cast aluminium housing, toughened glass, silicon gasket, 4000K high power LED with lens for uniform distribution pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire including clamps and nut bolts for fixing complete all as specified and directed.
Disconnecting all HT/LT connection/cable connection of defective indoor transformers, 11KV/433 V of Capacities 630 KVA and re-connecting the same after repair complete all as specified and directed.
Lifting up and down of 1000 KVA by Hydra crane and Transportation to workshop for repair/rewinding of defected transformer including re-installation of repaired transformer in original position after repair complete all as specified and directed.
Dismantling of same Transformer at workshop for complete for repair/rewinding and re assembling after repair complete all as specified and directed.
Supply and fix in replacement all gasket of transformer by new brand complete all as specified and directed.
S&F in replacement, porcelain Transformer bushing on LT(440 Volts) side including brass stems conical bush and gasket for indoor transformer of capacity 630 KVA complete all as specified and directed.
S&F in replacement, porcelain transformer bushing on HT side (11 KV) including brass set stems conical bush and gasket for indoor transformer 630 KVA complete all as specified and directed.
Supply and fix new HT/LT copper coil made out of proper/ required as per the existing size copper wire enameled of high quality matching with the existing impedance and pre- insulation complete all as specified and directed.
S&F in replacement Tap changer with tapping arrangement 2.5% and 7.5% on normal tapping as required for Transformer of any capacity 630 KVA complete all as specified and directed.
S&F in replacement silica gel breather assembly including vent pipe and silica gel for indoor transformer of capacity up to 630 KVA complete all as specified and directed.
S&F in replacement, gate valve of gun metal 15 mm bore as per existing with gasket complete to prevent oil leakage from transformer of any capacity complete all as specified and directed.
Supply and topping up of transformer oil with di-electric strength not less than 50 KV in to the conservator tank/ body tank of the transformer etc at various locations complete all as specified and directed. Note-: for item no 70 to 80 BOO for inspection of repairing and rewinding of transformer during urgency of work will detailed by GE SW . BOO will check following things during urgency of work :- (a) Gate Pass issued by User, (b) Testing required for transformer rewinding work shop. BOO will visit workshop during urgency of work. (c ) Photos of rewinding work. (d) Paid vouchers and invoice issued by rewinding workshop.
SANJEEV ENTERPRISES (BID ID -3277773)
R R Associates (BID ID -3276117)
SETHI ENTERPRISES (BID ID -3277378)
SNOWY ENGINEERING INC (BID ID -3278017)
SB ENTERPRISES (BID ID -3277359)
VINAY ENTERPRISES (BID ID -3277964)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .