PROVISION OF SF6 CIRCUIT BREAKER 66 KV AGAINST BER FOR 5 MVA TRANSFORMER AT TMS UNDER GE GURDASPUR
2020_MES_400591_3
CWE/ASR-73/2020-21
Open Tender
Civil Works
Item Rate
180 days
Gurdaspur
Class E
Category bii
8 documents required · 8 mandatory
₹500
GE Gurdaspur
₹24,000
Yes
22 May 2021
8 Mar 2021
26 Mar 2021
8 Mar 2021
24 Mar 2021
11 Mar 2021
Amount
Taking down carefully SF6 breaker 66 KV capacity, incomer/outgoing feeder complete removing with connectiong material complete and diposited to MES store for keeping in safe custody all as directed and specified
Supply, installation, testing and commissioning of Circuit breaker SF-6 outdoor type 66 KV nominal voltage 3 phase, 50 Hz as per IEC-62271-100 complete with all accessories and of the following technical specifications complete all as specified and directed by Engineer-in-Charge :- (a) Highest system voltage between phase 72.5KV (b) Rated normal current : 1650 Amps (c) Rated power frequency withstand voltage :- 140 KV (d) Rated lightning impulse with stand voltage: 325KVP (e) Short Circuit breaking current : 31.5KA (f) Short Circuit making current : 80 KA (g) Rated duration of shrot circuit 3 seconds (h) Minimum creepage distance to ground : 1813mm (j) Type of mechanism enclosed in housing, motor operating spring-spring (k) Rated operating sequence : 0-0.3 Sec CO-3 Min CO (l) Rated closing / triping voltage : 220 VDC (m) Current of closing / triping coil : 6 A max at 220 VDC (n) Rated current for terminal connections : 630 Amps all other specifications as per stand IE rules and as directed Note :- (i) Testing and commissioning of SF-6 circuit breaker including checking of compatibilty with existing 5 MVA power transformer shall be done by the PSPCL department. The contractor will deposit the calibration/testing & commisioning charges whatsoever to PSPCL department and make necessary arrangements for the testing and commissioning of new SF-6 circuit breaker. The charges of PSPCL department transportation, checking charges, tools and plants etc as required are included in the quoted rate and nothing extra on this account shall be paid.
Earthing complete with galvanized steel earth plate electrods of size 60cmx60cmx6mm thick burried directly in ground vertically(earth pit not less than 3.35 mtr deep below normal ground level) with top edge of the plate not less than 2.75 mtr below normal ground level connected to galvanized iron or steel strip of 32 x 6mm by means of bolts nuts check nuts and GI washers of Galvanised iron protected by steel pipe 15mm (light grade) all as shown in elecrrical plate No.5 of SSR Part-I and connecting to earthing test point (earth test point to be provided at 5 mtr distance from earth pit) and testing on completion including necessary excavation and earth work. The rate also include charcoal dust and comman salt in alternate layers 25 mm dia light grade GI pipe,funnel,wire mesh.concrete 1:3:6 type C-1 for pit and RCC pit cover. PCC pit shall be provided 50 cm away from earth pit and not on the earth pit itself. The extra cost of the watering pipe,bends,elbows shall be included in the unit rate.
Supply and installation of 66 KV out door oil cooled Potential Transformer of following specification :- (a) Outdoor Type (b) Voltage between phase :- 72.5 KV (c) Short circuit breaking current : 31.5 KA (d) Hermatically sealed (e) PT Ratio : 66 KV/ /√3/110V/ /√3/110V/ /√3 (f) Core 1 : class - 0.2 Burden : 100 VA (g) Core 2 : Class -3P, Burden : 100 VA other specifications as per stand IE rules and entire satisfaction of the Engineer-in-Charge Note :- (i) The foundation for fixing of PT shall be provided by the contractor as per manufacturer instructions without any extra cost
Supply and installation of 66 KV out door oil cooled Current Transformer of following specification :- (a) Outdoor Type (b) Voltage between phase :- 72.5 KV (c) Short circuit breaking current : 31.5 KA for 3 Seconds (d) Four core live tank type CT (e) Hermatically sealed (f) CT Ratio : 100/50/1-1-1-1 (g) Core 1 : class - 0.2 Burden : 30 VA (Metering) (h) Core 2 : Class -5P20, Burden : 30VA (Protection) (j) Core 3 : Class - PS (Differential) (k) Core 4 : Class - PS (Ref) other specifications as per stand IE rules and entire satisfaction of the Engineer-in-Charge Note :- (i) The foundation for fixing of PT shall be provided by the contractor as per manufacturer instructions without any extra cost
M/s Shiksha Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .