Tender Value
₹1.3 L
EMD Value
₹2,605
Closing Date
22 Jun 2026, 12:00 pm
Er. Ravinder Singh
Executive Engineer, Electrical Division No. 2, 1st Floor Additional Deluxe Building Sector- 9/D, Chandigarh.
As per NIT
2026_CHD_93302_1
E2/26/55
Open Tender
Electrical Works
90 days
Chandigarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹2,605
12 Jun 2026
12 Jun 2026
22 Jun 2026
12 Jun 2026
22 Jun 2026
12 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1DSR item No.11.3 Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. | |||||
| 1.01 | 3½ X 95 sq. mm | 1 | Each | 4,565 | ₹4,565 |
| 1.02 | 3½ X 120 sq. mm | 1 | Each | 5,386 | ₹5,386 |
| 2 | Servicing, testing, and repairing of LT Air Circuit Breaker (ACB) of rating 630 Amp to 3200 Amp, 415 Volts, including withdrawal of the ACB trolley from the LT panel, dismantling, inspection, cleaning, testing, fault detection, and rectification of defects. The scope of work shall include checking and servicing of operating mechanism, auxiliary contacts, control wiring, arc chutes, spring charging mechanism, interlocks, and all associated components required for proper functioning of the ACB. (Please refer DNIT for complete specification of item no.2) | 1 | Per Job | 2,000 | ₹2,000 |
| 3 | Repairing, servicing, testing, and commissioning of 11 KV HT Vacuum Circuit Breaker (VCB) (Incomer/Outgoing) of rating 400 Amp, 630 Amp, or 800 Amp, including isolation of the feeder, disconnection of HT cables, withdrawal of VCB trolley from the HT panel, dismantling, inspection, fault diagnosis, and rectification of defects. The scope of work shall include cleaning of the flashed/burnt area, removal of moisture, servicing of operating mechanism, checking of vacuum interrupters, auxiliary contacts, control circuit wiring, spring charging mechanism, mechanical and electrical interlocks, tripping and closing circuits, and all associated components required for proper operation of the VCB.(Please refer DNIT for complete specification of item no.3) | 1 | Per Job | 3,000 | ₹3,000 |
| 4DSR item No.2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. | |||||
| 4.01 | 100 A,30KA,FPMCCB | 2 | Each | 8,127 | ₹16,254 |
| 4.02 | 125 A,30KA,FPMCCB | 1 | Each | 8,644 | ₹8,644 |
| 4.03 | 400 A,50KA,FPMCCB | 1 | Each | 44,663 | ₹44,663 |
| 5 | Locating of fault in underground laid HT cable with the help of suitable cable fault locating equipment/machine, including identification of the exact fault location through pre-location and pin-pointing techniques. (Please refer DNIT for complete specification of item no.5) | 1 | Each | 8,000 | ₹8,000 |