Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
8 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Col Pawan Kumar, CWE
Headquarters, Commander Works Engineer, Bhopal, Military Engineer Services, SI Line, Bhopal, Pin Code - 462001 (Madhya Pradesh)
REPAIR/MAINTENANCE OF CENTRAL AC PLANT AND CONNECTED ITEMS AT RMS AJMER UNDER GE NASIRABAD
2026_MES_799507_1
84374/E8
Open Tender
Civil Works
Item Rate
180 days
Nasirabad
AS PER NIT CONDITION
7 documents required · 7 mandatory
₹500
Yes
GE Nasirabad
₹20,000
Yes
19 Nov 2026
19 Nov 2026
10 Dec 2026
19 Nov 2026
8 Dec 2026
3 Dec 2026
19 Nov 2026 - 3 Dec 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for maintenance of complete Central AC chiller plant of capacity 3 X 78.8 TR Capacity AC Plant RMS Ajmer. (Model no: SY300AYMBB DANFOSS (DWAP No. NSB-AM-GEM-01253). The scope of work is as under:-
Checking the functioning of chiller unit/Air handling unit/Pumps/Cooling tower/Controls and such equipment covered under the contract. Checking the compressor for its proper working. Annual pumping down and restarting as & when required. Checking the microprocessor control panel, control boards, transducers of packaged chillers/condensing unit for their correctness. Replacing of parts due to normal wear & tear. Checking the refrigeration system, motor arıd starters and ensuring healthy condition of the plant. Checking the system for any leaks and rectification of leaks found Taking set of readings and evaluating to ensure satisfactory performance of the plant, Checking the Refrigeration control system for operation and adjusting the settings, Checking the functioning of compressors and its accessories, Cleaning and dust free ac plant room by vacuum cleaner, Lubricating the bearings of motors, & fans when found necessary, inspection of belts adjusting the tension and replacing the worm out belt as and when found required, Replenishment of refrigeration gas as a result of wear and tear or any other means, Overhauling the components of the equipment at site or in service station as and when required. Checking of the microprocessors PCBs and sensors of IDU/ODU units for its proper functioning and repair/ replacement of the same if found necessary to make the overall system serviceable.
Notes:- (i) Spare parts required for repair/ rectification of defects shall be measured and paid separately under respective items here in after.
(ii) Contractor will ensure proper functioning of AC plants at all working days times and maintain the adequate temperature.
(iii) Petty small parts required for repair i.e. nuts, bolts, washers screws, saddles, grease, oil/ lubricants etc. shall be provided by the contractor without any extra cost to the government. | 1 | Each Job | - | - |
| 2 | M&L replacement of Old lube oil Danfoss 320SZ POE of Screw compressor, flushing and replacement with New Lube oil all as per specification of OEM standard 320SZ/as per site requirement including testing complete all as specified and directed by Engineer-in-Charge. | 30 | Ltrs | - | - |
| 3 | M&L for servicing of electric control panel of AHU / Chiller Unit by cleaning the panel with blower, checking of electric circuits/connections, replacement of unsv burnt wire, cables with existing size & length including proper numbering, replacement of u/s fuse link, lugs, washer, nuts, bolts, checking proper electrical connection, connectivity etc. & find out defective parts and making the panel functional by replacing the unsv item complete all as specified and directed by Engr-in-charge.
Note:(i) Unserviceable parts as MCB, MCCB, contactor, relay etc. will be measure and paid separately under relevant item of Sch A as s supply only.
(ii) Minor parts like thimbles, tags, nut, bolts, washers etc shall be deemed to be included in quoted rate. | 5 | Each Job | - | - |
| 4 | M&L for taking down existing wiring & S&F for re-wiring of existing of Main Electric Panel board/Control panel board of Central/Package type AC Plant with replacement of wiring cable with existing size, & length including proper numbering, replacement of fuse link, lugs, washer, nuts, bolts, checking proper electrical connection, connectivity etc. & find out defective parts and making the panel functional by re-wiring, complete all as specified and directed by Engr-in-charge.
Note: (i) Unserviceable parts as MCB, MCCB, contactor, relay, MPD, etc. will be measure and paid separately.
(ii) Minor parts like thimbles, tags, nut, bolts, washers etc shall be deemed to be included in quoted rate. | 1 | Each Job | - | - |
| 5 | M & L for Descaling the condenser by descaling compound / hydrochloric acid by soaking method,disconnecting condensor from the system by taking out nuts, bolts, studs, valves and MS/GI pipe line from both side cover, cleaning each tube with nylon brush,flushing with alkaline solution,connecting back both side cover including replacingleather gasket 4 mm thick for following capacities of condensers suitable for AC Plant installed as indicated below complete all as specified and directed and all as per manufacturers instruction and to the entire satisfaction of Engineer-in-charge. | 12 | Each Condenser | - | - |
| 6 | M&L for vacuumization & leakage test of a unit with pressure testing with dry nitrogen to a pressure upto 1.5 times of operating pressure & find the detection of leak and vacuumization by a rotary vacuum pump to reomve the moisture and gases & Hold the Vacuume for 24 hours.complete all as specified and directed. | 3 | Each Unit | - | - |
| 7 | M&L for charging of Refrigerant R22 as per site requirement in AC Plant of any capacity complete all as specified and directed by Engr-in-Charge. Note: Refrigerant will be charged in compressor after all type of testing like leakage or vacuumizing. Any Leakage/reduction in pressure after charging will be done by contractor and no extra payment will be paid for this leakage refilling. | 205 | Kg | - | - |
| 8 | M&L for complete servicing and cleaning of AHUs of Capacity 23000 CFM with AHU Room complete with various accessories i.e. blower with casing, Chiller water coil, Hot water coil, pre filter & fine filter frame, drive motor, humidification kit, motorised control valves, control panel including descaling of chilled/hot water coils, Greasing, Lubricating of moving parts and Repair/Replacement of bush, thrust plate, gland packing, driver pully, driver shaft and re-assembling all the dismantled componenets to its original position, testing complete all as specified and as per directed.
Note :- (i) AHU chilled/hot water coils using chemical with brass brush in-order to remove all type of sledge/dust precipitatated on the coil without any damage to the copper coil then wash the cooling with fresh water and air blower upto the satisfactory of Engr-in-Charge. (ii) Iron body of the AHU inside and outside shall be scrap down and rub out with sand paper then apply one coat primer over a coat of synthetic enameld paint including part of duct portion in the AHU shall be completed upto the satisfactory of Engr-in-Charge. (iii) Complete AHU Room clean by vacuume cleaner. | 1 | Each job | - | - |
| 9 | Ditto above but 17000 CFM | 1 | Each job | - | - |
| 10 | Supply, fixing & commissioning of Air/water cooled chiller controlled PCB with display unit PCB complete set for water cooled AC plant of Capacity 78.8 TR as per sample complete all as specified and directed by Engr-in Charge. | 1 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_897020.xls
BOQ • 0.33 MB
84374TenderDocuments.pdf
Tender Documents • 1.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .