Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC VILL MANKAR NORTH RAIPUR PO MANKAR DISTT PURBA BARDHAMAN PIN 713144 WB | MANKAR | PURBA BARDHAMAN | WB | 713144 | L1 | Accepted-AOC Accepted being Lowest Bid Value | |
| 2 | L2₹11.1 L+₹1.4 L (14.7%)Rejected-AOC | L2 | Rejected-AOC Rejected being Higher Bid Value | |
| 3 | L3₹12.4 L+₹2.8 L (28.5%)Rejected-AOC | L3 | Rejected-AOC Rejected being Higher Bid Value | |
| 4 | Rejected-Technical ROOM NO 262 PART II NEAR SANKER MANDIR GANESH MURTHI NAGAR COLABA MUMBAI 05 | MUMBAI | - | Rejected-Technical Rejected due to not enlisted in approriate category | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected due to not enlisted in approriate category |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
4 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE PANAGARH
HQ CWE PANAGARH, MES, PO - PANAGARH, DIST - BURDWAN, WB, PIN - 713420
REPAIR / MAINT OF EXT ELECTRIC SUPPLY INSTALLATION AND CONNECTED ITEMS AT NMS UNDER CWE PANAGARH
2024_MES_643700_1
8895/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NABAGRAM
Pls refer Tender Documents
7 documents required · 7 mandatory
₹500
AGE (I) NABAGRAM
₹24,000
Yes
30 May 2024
22 Feb 2024
12 Apr 2024
22 Feb 2024
4 Apr 2024
21 Mar 2024
Amount
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth; for foundation laying of cables ,etc or for shafts,wells,cesspits,manholes,pier holes,etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/lose soil, complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil under floor, complete all as specified and directed.
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed.
M&L and filling clear, dirt less, river sand as 8 cm bedding layer & covered with 15 cm & ultimately punned down 5 cm as sand cushioing for cable protection, complete all as specified and directed.
Supply and laying Sub Class "B" Bricks Designation 75 as in cable Protection, complete all as specified and as directed.
M&L boring of horizontal holes/trenchless hole for 80 mm bore pipe under the road below 1.50 mtr from the road/hard surface by trencheless technology using ultrasonic technique and including necessary machine without damaging the existing road and getting out in any type of soil and disposal of soil to a distance not exceeding 50 m from the site of work, complete all as specified and directed. (Note : Pipe Shall be measured and paid seperately.)
S&F galvanised iron tubing 80 mm bore, light grade with all fittings & fixture as in cable protection laid in trenches/floor or on the Pole etc., complete all as specified and directed.
Suppy and laying, testing complete XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volt grade, cross sectional area 240 Sqmm 4.0 core including taking up of old unserviceable cable, complete all as specified and directed.
Suppy and laying, testing complete XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with aluminium conductor, 11000 volts Earthed grade cross sectional area 95 Sqmm including taking up of old unserviceable cable, complete all as specified and directed.
S&F cable jointing kit for 11 KV grade cable for straight through heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95 sqmm, complete all as specified and directed.
S&F in repairs Bus bar chamber fabricated by using sheet steel (CRCA) of 3.15mm thickness and impact resistant epoxy powder coated to give superior & lasting finish of size approximately 900 mm (h) X 800 mm (w) x 700 mm (d) 4 strip aluminum busbar of size 400 Amps rating for phase and neutral ,400 mm long,duly fixed on porcelain insulator made out of 3.15 mm thick M.S Sheet and with proper weather protection (rain protection canopy) having four legs of 1.5 mtr with angle iron 80 mm x 80 mm x 5mm thick on floor with PCC foundation 450 mm x 350mm x 250mm type B1 (1:2:4) (using 20 mm crushed stone aggregate), duly powder coated paint having two parts front & back opening door including earth terminal point, cable connection and including one three pole MCCB 125 Amp 16 KA of fixed thermal magnetic setting as incoming, complete all as specified and directed.
M&L in repairs Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade, complete all as specified and directed.
M&L in repairs Anti-climbing device; spikes type fabricated out of M.S. bars (round square and flat) including nuts,bolts, washers and welding in two halves made to shape to suit the cross section of the pole, complete all as specified and directed.
M&L in repairs Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size, complete all as specified and directed.
M&L in repairs Lightning arresters, expulsion type, suitable for 11000 volt complete with all fittings, transmission class, discharge capacity 65 kilo amp, complete all as specified and directed.
M&L as in repairs switches air break 11000 volt, gang operated, triple pole mechanically operated, mounted on insulators and steel frame with operating mechanism worked from ground level for current rating upto 400 Amps, frequency 50 Hz incl dismantling old unserviceable one, complete all as specified and directed.
M&L as in expulsion fuse, single pole, 11000 volts, above 25 and upto 50 amp incl dismantling old unserviceable one, complete all as specified and directed.
Repair/replacement & servicing of two pole & four pole structure by greasing of mechanical linkage gang operated switch, DO, dismantling of existing detoriated ACSR jumper, replacing of unserviceable 11000 volt Pin insulator & reconnected with new ACSR jumper, using new drop out fuse unit, changing of lever hook and locking arrangement complete all as specified and directed. (Note : Contractor shall be taken proper 11 KV shut down and do the work in presence of 11 KV license holder Electrician with proper electrical safety guard equipments.)
M&L painting to HT Two pole and four pole structure with cross arm, support arm complete with one coats of aluminium paint, complete all as specified and directed. (Note : Contractor shall be taken proper 11 KV shut down and do the work in presence of 11 KV licecnse holder Electrician with proper electrical safety guard equipments.)
M&L painting to 250 KVA stepdown transformer of existing colour with one coats of synthetic enamel paint, complete all as specified and directed. (Note : Contractor shall be taken proper 11 KV shut down and do the work in presence of 11 KV license holder Electrician with proper electrical safety guard equipments.)
S&F cable jointing kit for 11 KV grade cable for Outdoor termination heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95 sqmm, complete all as specified and directed.
S&F cable jointing kit for 11 KV grade cable for Indoor termination heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95 sqmm, complete all as specified and directed.
Taking down the defective air breathers from the transformers, supply and fix new breathers suitable for step down distribution transformers of any make and capacity 250 KVA including filling of new silica gel in breathers, complete all as specified and directed.
Supply and topping up transformer oil conforming to IS:335 (1993), dielectric strength not less than 60 KV at 2.5 mm gap in various capacities distribution transformers installed at various indoor and outdoor sub stations, complete all as specified and directed. (Note : Original Purchase Voucher, Test Certificate shall be submitted to Engr-in-Charge for claiming of payment.)
Dehydration of transformer oil of various capacities distribution transformers installed at various indoor and outdoor substations with ultra high vacuum filtration machine to obtain the dielectric strength of 60 KV at 2.5 mm gap, complete all as specified and directed. (Note : Test Report shall be submitted duly approved for claiming of payment.)
M&L testing earthing complete with galvanised steel earth plate electrode 60 X 60 X 6.3 mm thick buried directly in ground vertically at a depth (earth pit not less than 2.25M deep below ground level with top of the plate not less than 1.5 meter below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal, dust & common salt filling in alternate layer and electrode connection by using galvanised iron strip 32X6mm as eatrhing lead(up to the test point) by means of boltts nuts, check nuts and washers made of GI tubing 40 mm bore, GI pipe connected upto test point and GI pipe light grade 20mm bore for watering and including funnel, wire mash, RCC pit cover (1:1.5:3) (using 20 mm graded stone aggregate) including using 8 mm dia Tor reinforcement 100 mm c/c both way & MS handle on top and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate no 3 of SSR-2009 (Part-1) and testing earth resistance upto satisfactory level, complete all as specified and directed.
SAI ENGINEERING
M/S SAIMON ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .