Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.3 LAccepted-AOC ROOM NO 01 1ST FLOOR SIMA TRADING BUILDING SURVEY NO 268 GARACHARMA VILL SRI VIJAY PURAM 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹50.4 L+₹3.1 L (6.45%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 3 | L3₹50.7 L+₹3.4 L (7.18%)Rejected-Finance NEAR PLAY GROUND BIRDLINE CALICUT POST PORT BLAIR 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L3 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 4 | L4₹53.3 L+₹6.0 L (12.6%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 5 | L5₹54.9 L+₹7.6 L (16.0%)Rejected-Finance BRICHGUNI CHOWK PROTHRAPUR SOUTH ANDAMAN SRI VIJAYA PURAM 744103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L5 | Rejected-Finance NOT BEING LOWEST BIDDER |
| Sl No | Description | Qty | Unit | CHANDER SEKER ENTERPRISE L7 | M/s Saina Enterprises L3 | M/s Gurunath Construction L1 | ANITA VARMA ENTERPRISES L4 | RS ENGINEERING WORK L8 | SIMONS CONSTRUCTION L5 | DEEPAK AGENCIES L6 | M/s K Moorthi L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of post or struts (Wood, Steel or RCC) of any section including taking out embedded postion from natural ground and making good disturbed ground complete all as specified | 152 | RM | 58 ₹8,816 | 66 ₹10,032 | 55 ₹8,360 Lowest | 60 ₹9,120 | 70 ₹10,640 | 55 ₹8,360 Lowest | 69 ₹10,488 | 60 ₹9,120 |
| 2.00 | Dismantling of fencing wire mesh any size and description all as specified and directed | 575 | Sqm | 66 ₹37,950 | 20 ₹11,500 Lowest | 20 ₹11,500 Lowest | 20 ₹11,500 Lowest | 45 ₹25,875 | 30 ₹17,250 | 33 ₹18,975 | 25 ₹14,375 |
| 3.00 | Excavation in post holes (or similar holes) each not exceeding 0.5 cum getting out in Hard/dense soil returnig filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25cm watering and removing surplus soil to a distance not exceeding 50m and making good surfaces complete. | 169 | Each | 497 ₹83,993 | 472 ₹79,768 | 450 ₹76,050 Lowest | 495 ₹83,655 | 650 ₹1,09,850 | 477 ₹80,613 | 482 ₹81,458 | 450 ₹76,050 Lowest |
| 4.00 | M & L PCC in foundation filling and mass concrete typeType C2 1:3:6 (40 mm graded aggregate) complete all as specified and directed. | 28 | Cum | 13,807 ₹3,86,596 | 13,111 ₹3,67,108 | 12,500 ₹3,50,000 Lowest | 14,060 ₹3,93,680 | 13,500 ₹3,78,000 | 13,500 ₹3,78,000 | 13,381 ₹3,74,668 | 12,932 ₹3,62,096 |
| 5.00 | M&L for providing reinforced cement concrete type B-1 (using 20mm graded stone1 :2:4 20mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc, for fencing, average sectional area exc 100 sqcm and n.exc 250 Sqcm with or without chammfered angles and flat, splayed, rounded or mitred tops as directed and fixed etc. compete all as spd and directed. | 1.58 | Cum | 15,243 ₹24,083.94 | 14,475 ₹22,870.5 | 13,800 ₹21,804 Lowest | 15,520 ₹24,521.6 | 15,200 ₹24,016 | 14,000 ₹22,120 | 14,772 ₹23,339.76 | 14,800 ₹23,384 |
| 6.00 | M&L for high strength corrosion resistant TMT bars 10mm dia and over cut to length, bent to shape required including cranking and bending spirally for hopping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia) or securing with clips complete. | 283 | Kg | 180 ₹50,940 | 146 ₹41,318 | 139 ₹39,337 Lowest | 160 ₹45,280 | 195 ₹55,185 | 200 ₹56,600 | 205 ₹58,015 | 145 ₹41,035 |
| 7.00 | All as per item No 6 above but 5 to 10 mm dia as in stirrups, spacer etc complete. | 77 | Kg | 200 ₹15,400 | 155 ₹11,935 | 138 ₹10,626 Lowest | 160 ₹12,320 | 144 ₹11,088 | 170 ₹13,090 | 180 ₹13,860 | 140 ₹10,780 |
| 8.00 | S & F for Mild steel works as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. | 2,071 | Kg | 200 ₹4,14,200 | 195 ₹4,03,845 | 165 ₹3,41,715 Lowest | 190 ₹3,93,490 | 215 ₹4,45,265 | 200 ₹4,14,200 | 210 ₹4,34,910 | 185 ₹3,83,135 |
| 9.00 | Supply only PVC coated (1mm thick) chain link fencing exc 2.00 but n.exc 3.50 kg per sqm with size of mesh 50 x 50 mm and thickness of wire n.exc 2.83 mm all as specified and as directed. | 4,025 | Kg | 232 ₹9,33,800 | 220 ₹8,85,500 | 210 ₹8,45,250 Lowest | 240 ₹9,66,000 | 255 ₹10,26,375 | 280 ₹11,27,000 | 275 ₹11,06,875 | 225 ₹9,05,625 |
| 10.00 | Fixing only PVC coated chain link fencing including fixing of line wires any mesh, size and any type of standards, rails, straining bolts etc including provision of binding wires complete.(Supply of MS line wire and flat iron bolt & nuts measured and paid seperately) | 1,150 | Sqm | 22 ₹25,300 | 20 ₹23,000 Lowest | 20 ₹23,000 Lowest | 20 ₹23,000 Lowest | 44 ₹50,600 | 28 ₹32,200 | 30 ₹34,500 | 25 ₹28,750 |
Tender Value
₹45.4 L
EMD Value
₹90,800
Closing Date
9 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Brichgunj Sri Vijaya Puram
GE Brichgunj Sri Vijaya Puram
PROVN OF COMMAND LECTURE POST NEAR BLDG NO 299 QUARTER GUARD AT INF BN NO TWO BRICHGUNJ MIL STATION PORT BLAIR AND AND OTHER SANCTIONED WORKS UNDER GE BRICHGUNJ MIL STN SRI VIJAYA PURAM
2025_MES_721547_1
8652A
Open Tender
Civil Works
Item Rate
180 days
GE Brichgunj Sri Vijaya Puram
Class D a(i)
9 documents required · 9 mandatory
₹500
GE Brichgunj Sri Vijaya Puram
₹90,800
Yes
27 Sept 2025
19 Jul 2025
11 Aug 2025
19 Jul 2025
9 Aug 2025
4 Aug 2025
Amount
Dismantling of post or struts (Wood, Steel or RCC) of any section including taking out embedded postion from natural ground and making good disturbed ground complete all as specified
Dismantling of fencing wire mesh any size and description all as specified and directed
Excavation in post holes (or similar holes) each not exceeding 0.5 cum getting out in Hard/dense soil returnig filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25cm watering and removing surplus soil to a distance not exceeding 50m and making good surfaces complete.
M & L PCC in foundation filling and mass concrete typeType C2 1:3:6 (40 mm graded aggregate) complete all as specified and directed.
M&L for providing reinforced cement concrete type B-1 (using 20mm graded stone1 :2:4 20mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc, for fencing, average sectional area exc 100 sqcm and n.exc 250 Sqcm with or without chammfered angles and flat, splayed, rounded or mitred tops as directed and fixed etc. compete all as spd and directed.
M&L for high strength corrosion resistant TMT bars 10mm dia and over cut to length, bent to shape required including cranking and bending spirally for hopping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia) or securing with clips complete.
All as per item No 6 above but 5 to 10 mm dia as in stirrups, spacer etc complete.
S & F for Mild steel works as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
Supply only PVC coated (1mm thick) chain link fencing exc 2.00 but n.exc 3.50 kg per sqm with size of mesh 50 x 50 mm and thickness of wire n.exc 2.83 mm all as specified and as directed.
Fixing only PVC coated chain link fencing including fixing of line wires any mesh, size and any type of standards, rails, straining bolts etc including provision of binding wires complete.(Supply of MS line wire and flat iron bolt & nuts measured and paid seperately)
Supply only mild steel angles, bars, flats etc as in supports for stiffening of fencing, wall ties, hold fasts, clamps and similar small articles confirming to Fe-290 Gde E-165 All as specified and directed.
Supply only mild steel bolt with hexagonal or square head one end and screwed the other or screwed both ends each screwed is to be fitted with washers and one hexagonal or square nut exceeding 10cm long n.exc 15 cm long dia mtr of neck exc 11 to 15 mm complete all as specified and directed by Engineer-in-Charge.
M&L for preperation of new plastered surfaces of walls/posts/columns and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
Preparation of new surfaces of steel n.exc 10cm girth or width and applying two coats of synthatic Enamal paint over a coat of red oxide primer complete all as specified and as directed over .
Preparation of new or previously untreated steel surfaces & applying a two coats of synthetic enamel paint over a coat of red oxide primer over 10cm in width or girth,not otherwise described.
Dismantling mild steel work of any description complete all as specified and as directed
M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including concealed PVC conduit and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable green in colour as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets,fan regulators etc., all as specified and as directed forthe following One light point controlled by one switch
One fan point controlled by one switch and one regulator
One 3 pin switch socket outlet point 5 amps on same board with other switches
One 3 pin switch socket outlet point 5 amps on independent board
All as per item No 17 here-in-before but for 3 pin 15 Amps switch socket combination on independent board with 4 sq mm copper cable and provision of 4 sq mm FRLS PVC insulated stranded copper conductor cable for earth continuity conductor connected to common earth dolly connecting upto fittings complete all as specified and as directed.
Supply and fixing Modular switch 1 way 5 A, 1 module all as specified and directed.
Supply and fixing Modular switch 1 way 15 A, 1 module all as specified and directed.
Supply and fixing modular socket outlet, 2/3 pin combined , 6/16 Amps, combined 2 module, 230 volts all as specified and directed.
Supply and fixing modular socket outlet, 2/3 pin combined , 6 Amps, combined 2 module, 230 volts all as specified and directed.
S & F modular white cover plate with frame, 3 module all as specified and directed.
S & F modular white cover plate with frame, 4 module all as specified and directed.
Supply and fixing modular fan step regulator suitable for BLDC fan , 230 V, AC, 120W - 2 module
Supply and fix ceiling rose surface bakelite 65x50mm 3 terminal complete all as specified and as directed.
S&F ceiling fan of sweep 1200mm, 240volts, not less than 26 Watt, 5 star BEE rating & without remote control , BLDC dust resistant fan connecting up with three core 1.0 Sqmm cable from ceiling rose with required length of down rod as required at site all as specified.
Supply and fix metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, double door suitable for mounting MCBs including taking down old MCB/DB complete all as specified and directed. Note-: Incoming & outgoing connections from the DB shall be provided with proper lugs/ thimbles etc
Supply and fix MCB single pole 240 volts, 6 to 32 amps "B" series complete all as specified and as directed by Engineer-in-Charge
Supply and fix single pole and netural 240 Volts 32 amps complete all as specified and as directed by Engineer-in-Charge
Supply and fixing energy efficient aluminium housing LED batten 22 /20 Watt mounted batten fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core shethed cable from fitting to ceiling rose all as specified and as diected.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant complete with IP 65/66 protection complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR PART-I connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc all as specified and directed by Engr-in-Charge.
supply & Lay XLPE insulated, heavy duty 1100 volt grade electric armoured LT UG cable with aluminium conductor of size 10 Sqmm 2 Core in trenches/along the wall/including making all connections, saddles, spacers including scaffolding if any required for saddling the cable in walls of building of height up to 25 meter, complete with aluminium lugs as required at site and as directed by Engr-in-Charge
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out Soft/loose Soil
Returning, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25cm soil / hard dense soil.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point.Soft Soil / hard dense soil
Supply & lay cable protection pipe of HDPE double wall corrugated (DWC) incl couplers,bends etc of size 50 mm OD and ID 38mm confirming to IS 14930 -II and ISI Marked all specified and directed.
Supply and laying in trenches/on ground GI tubing 'light grade' 50 mm bore, with all fittings complete all as specified and as directed.
Material and Labour for cutting existing BT / PCCroad of size 45cm x 60cm for taking out/laying of underground cable/pipe and including necessary earth work and refilling the same in layers well ramming including watering as required and matching with the existing surface with 200mm thick PCC 1:2:4 type B1 and curing the same with wet gunny bags and removing debris to a distance not less than 50m complete all as specified and as directed .
Supply, lay/fix, connect and testing steel water tubing of 25 mm bore, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings and fixtures,Clamps and fixed to wall/ceiling or laid on floors including taking down of old unserviceable pipe complete all as specified and directed.
S&F in repairs gunmetal gate or globe valve for 25mm dia, conforming to IS-778, ISI marked, with iron wheel head screwed at both ends for iron pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc and any addition / alteration required for fixing, complete all as specified and as directed.
Supply and fix 25 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed, complete all as specified and as directed
Supplying, hoisting and fixing rotational moulded polythylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of 1000 Litre capacity etc complete all as specified and directed.
M&L for PCC in foundation filling and mass concrete type C2 1:3:6 (40mm graded stone aggregate) all as specified.
M &L Fe 410 -W (GdeE- 250) quality "A" Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated)
S&F MS steel work in tubular, trusses incl purlins, special shaped washers etc complete using ERW or induction butt welded tubes confirming to IS-1161-1979 grade 240 all as specified.
M&L for plates of plain or chequered, square cut or notched of steel welded to steel structure for base plate etc.
M&L for prepainted galvalume aluminium zinc coating GI based corrugated sheet 0.5mm thick of colour having tesile strength of 550Mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified.
M&L for prepainted galvalume aluminium zinc coating GI based plain sheet 0.5mm thick of colour having tesile strength of 550Mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil all as specified.
M&L Surface dressing n exc 15 cm deep and getting out in soft loose Soil complete all as specified.
M&L for PCC 1:4:8, type C2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete all as specified
M&L for precast cement concrete solid block masonry with solid blocks using PCC 1:3:6, type Cl (using 20mm graded stone aggregate), exc. 10cm in width, set in CM 1:6 complete all as specified
M&L rendering 10 mm thick on fair faces of concrete/block masonry surfaces in cement mortar 1:6 and finished even and smooth without using extra cement.
M&L preparing newly plastered surfaces ,and applying 2 coats of Oil Bound Distemper over a coat of alkali resistent primer incl putty with smooth finish on walls.
M& L for preparation of newly plastered wall surface and finishing wall with Acrylic smooth exterior paint of required shade two or more coat applied@t 1.67 ltr/10sqm and including priming coat of exterior primer applied @ 2.020 kg/ sqm complete all as specified.
M&L for hard core of guage n.exc.63mm using broken stone aggregate spread, levelled, watered and rammed to a true surface.
M&L for 100mm thick PCC 1:3:6 type C2 all as specified complete all as specified and directed.
M&L 75 mm thick PCC1:3:6 Type C-2 for Plinth Protection complete all as specified and directed.
S & F coloured joint free non Skid ceramic tiles10 mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc. set, jointed and pointed in white or coloured cement to match over screed bed in cement mortar 1:4, 15 mm thick, all as specified.
Supply and placing in position heavy duty supports with 8 FRP streep Metal, high quality structure powder coated outdoor water resistant three seater bench of dimension 1600x787x609mm and wt approx 50kg of colour as approved by GE complate all as specified and as directed.
M/s K Moorthi (BID ID -3385326)
M/s Saina Enterprises (BID ID -3386861)
ANITA VARMA ENTERPRISES (BID ID -3385155)
SIMONS CONSTRUCTION (BID ID -3387075)
DEEPAK AGENCIES (BID ID -3386965)
CHANDER SEKER ENTERPRISE (BID ID -3385714)
RS ENGINEERING WORK (BID ID -3385918)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .