| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC | L1 | Accepted-AOC Being lowest amount | |
| 2 | L2₹27.1 L+₹3.3 L (13.6%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹33.8 L+₹9.9 L (41.3%)Rejected-Finance 1257 SCHEME NO 5 NEAR HB COLLEGE VIJAY NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
15 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JABALPUR
HQ CWE JABALPUR OPPOSITE SUPPLY DEPOT SADAR 482001
Repair and Maintenance of VCBs, Panel, HT cables and other connected works under GE (W) Jabalpur
2022_MES_524028_1
81956/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
JABALPUR
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE WEST JABALPUR
₹50,000
Yes
11 Aug 2022
13 May 2022
17 Jun 2022
13 May 2022
15 Jun 2022
3 Jun 2022
13 May 2022 - 26 May 2022
60 days
Amount
Repair and overhauling of gang operated drop out air break switch 33 KV double break rotating isolated fixed on 33 KV Gantry(33 KV Yard) with replacement of unserviceable parts complete all as directed by Engineer-in-Charge (Note : Labour element for replacement of unserviceable parts is deemed to be included in the unit rate quoted against this item. However, unserviceable parts will be measured and paid for separately under relevent items of this BoQ here-in-after as 'Supply only' )
Supply only tinned copper flexible jumper 400 Amps 33 KV to be fixed under item No. 01 here-in-before and testing on completion complete all as directed.
Supply only back connector plate to be fixed under item No. 01 here-in-before and testing on completion complete all as directed.
Supply only Fixed contact 33 KV for rotary type double break isolator ( GOD Switch ) to be fixed under item No. 01 here-in-before and testing on completion complete all as directed.
Supply only Male contact 33 KV for rotary type double break isolator ( GOD Switch ) to be fixed under item No. 01 here-in-before and testing on completion complete all as directed.
Readjustment, cleaning of contact, greasing and testing of out door type air break switch 11 KV, current rating upto 200 Amps including all materials required for alignment for AB switch in position and replacement of unserviceable parts complete all as directed by Engineer-in-Charge (Note : Labour element for replacement of unserviceable parts is deemed to be included in the unit rate quoted against this item. However, unserviceable parts will be measured and paid for separately under relevent items of this BoQ here-in-after as 'Supply only' )
Supply only brass terminal plate for mounting male contact of Air Break switch insulator including GI nuts and bolts, washers etc as required complete, to be fixed under item No. 06 here-in-before and testing on completion complete all as directed by Engineer-in-Charge.
Supply only male contact for Air Break switch contact suitable for 11 KV complete., to be fixed under item No. 06 here-in-before and testing on completion complete all as directed by Engineer-in-Charge.
Supply only female contact for Air Break switch contact suitable for 11 KV complete., to be fixed under item No. 06 here-in-before and testing on completion complete all as directed by Engineer-in-Charge.
Supply only post insulator for Air Break switch with metal part suitable for 11 KV complete conforming to IS : 5572-1972, to be fixed under item No. 06 here-in-before and testing on completion complete all as directed by Engineer-in-Charge.
Providing the cable fault locating Machine with necessary T&P at site for locating fault along the length of armoured 6.6 /11 KV XLPE/PILCA insulated HT cable complete all as required and directed at site
Supply only of handheld search light LED 10 watt 12 volts 7 AH with charging facality complete all as required and directed at site (Make : Kalin model KDL 10 SE or equivalent as approved by GE)
S&F, in replacement, PVC insulation tap, width 25 mm, length 5 metre complete all as directed by Engineer-in-Charge.
S&F, in replacement, HT insulation tap, width 25 mm, length 5 metre complete all as directed by Engineer-in-Charge( Make : 3M Birla or equivalent as approved by GE).
S&F, in replacement, fuse wire 100 Amp, complete all as directed by Engineer-in-Charge.
S&F, in replacement, fuse wire 200 Amp, complete all as directed by Engineer-in-Charge.
S&F in replacement DO fuse element of capacity 25 Amp to 60 Amp for 33 KV grade and testing on completion complete all as specified and directed.
S&F in replacement DO fuse element of capacity 10 Amp to 50 Amp for 11 KV grade and testing on completion complete all as specified and directed.
S&F in replacement DO fuse element of capacity 60 Amp to 100 Amp for 11 KV grade and testing on completion complete all as specified and directed.
S&F electrical rubber hand gloves suitable for 33 KV electrical pressure complete all as specified and directed. (Make - Jaipuria, Crystal or equivalent as approved by GE)
S&F electrical rubber hand gloves suitable for 15 KV electrical pressure complete all as specified and directed, (Make - Jaipuria, Crystal or equivalent as approved by GE)
Repair and overhauling the HT Panel after de screwing the panel side bolts and decarbonising the bus bar with carbon tetra chloride and tapping the bus bar with 3M birla tape compelete including tightening the electric connection complete all as required and directed by Engineer-in-Charge
Material and labour for signboard of size 2.4 M x1.2 M with and including 1.50mm thick acrylic cover , aluminium channel and making design of area running feeders with and including LED lamps and toggle switch including tube lights 1x40 watt -2 nos and fixing the sign board on the wall complete all as directed at site by Engineer-in-Charge.
Material and labour for writting letters( Block Roman, Italic or Indian) n exc. 30 cm high with and including fluorescent paint complete all as specified and as directed.
M&L for Vaccum interrupter 11 KV as per IS 13118-1991/IEC 56-1987 of 400 amps rating and testing on completion including taking down old unserviceable Vacuum Interrupter complete all as required and directed at site
Checking all the termination of control cable protection system of VCB (03 Nos), transformer 5 MVA( 02 Nos), 33 KV CTs( 09 Nos), 33KV PTs (03 Nos), cutting the faulty end of protection cable and making new connection with proper size of thimble and replacement of sliding connection if required and testing on completion complete all as directed by Engineer-in-Charge.
Checking and testing of 33 KV CTs (09 Nos) for VCBs by secondary injection current on primary side complete all as specified and directed.
Checking and testing 11 KV CT for HT VCB11 KV by secondary injection current complete all as specified and directed.
Calibration of voltmeter 33 KV ( 04 Nos), 11 KV ( 4 Nos) and Ammeter 33 KV(03 Nos), 11 KV( 12 Nos) with present system load complete all as specified and directed.
Checking for sluggish free operating mechanism including latching up of all circuit breaker i.e 33 KV VCB complete all as specified and directed.
Taking out HT OCB /VCB 11 KV (Make : Crompton Greaves) and carry out calibration with present system load complete all as specified and directed.
M&L for preparation of old steel surfaces of 33 KV VCB (05 Nos), transformers up to 5 MVA(05 Nos) and applying one coat of synthetic enamel paint as approved by GE complete all as specified and directed.
Supply and fixing of new vacuum interrupter 11 KV as per IS 13118-1991/ IEC 56-1987 of 800 Amps rating as per existing make/ as per manufacturer's instructions duly approved by Engr-in-Charge after taking out the old unserviceable vacuum interrupter and testing on completion complete all as directed.
Trimming of tree branches 4 metre all around, from the LT/HT pole, for clearing of LT/HT line, by cutting tree branches, any numbers and of any girth, on any number of conductors/earth wire complete all as specified and as directed by Engr- in- Charge. (Notes : (i) The above work includes cleaning/ pruning of tree branches falling around the conductors (ii) One length shall be measured for complete span of 4/5/6 conductors & GI wire.)
Re - stretching only of existing ACSR of any size, on HT/ LT pole including binding the ACSR with insulators, aluminium binding wire complete all as specified and as directed. (Note : One length shall be measured for complete span of 4/5/6 conductors & GI wire.)
Supply, fixing and connecting, in replacment, single pole zinc oxide (gapless surge type), heavy duty, station class, self supporting outdoor type lightning arrester having rated voltage 12 KV, discharge current 10.2 KAp, insulation level suitable for rated system voltage of 12 KV supply system with Maximum Continuous Operating Voltage (MCOV) not less than 10 KVrms with highly non-linear ceramic resister made of zinc oxide in hermetically sealed container complete with metal base, base insulator and suitable terminals for ground connections and pressure relieving arragement complete all as specified and as directed (Make : Cromption Greaves type ZLAX 15 or equivalent type in Raychem RPG Ltd/ELPRO). (Note : The unit rate quoted by the bidder is deemed to be inclusive of necessary fixing arrangement required for fixing of lightning arrester on two pole/four pole structure as per recommendation of Manufacturer.)
supply and fixing new stay assembly complete with accessories and GI stay rod 20 mm dia 1900 mm long, stay wire 7/8 SWG stranded galvanised including mild steel stay plate 300 mm X 500 mm x 6 mm and galvanised thimble, galvanised steel 14 mm dia 400 mm long stay bow and GI nuts, washers including loop type insulator vitreous porcelain white, brown or green big size with overall dimensions 90 mm x140 mm clearance of hole 25.5 mm complete all as specified and shown in electrical plate No. 1 of SSR Part - I (2009) including dismantling of existing unserviceable stay assembly complete all as specified and as directed. (Note : Loop type insulator, stay clamps, excavation and earthwork will be measured and paid for separately against relevant items of this BoQ)
Supply and fixing of new resin/ epoxy coated air cooled high tension current transformer of dual ratio of 100-50/5 Amps, 10 VA burden out put, accuracy class-0.5 conforming to IS 2705/IEC 60044-1 suitable for rated voltage system of 11KV for metering/ protection of breakers after taking out the old unserviceable CT and testing on completion complete all as directed. Make:- EEW or Alstom or Crompton Greaves or GEC or Areva as approved by GE.
M&L for painting of alternate black & white strips to four pole structure consisting of four steel tubular poles/ rail poles of HT/ LT of over head lines with and including synthetic enamelled paint, total 05 Nos each strips on each pole, each strip having 0.15M height total up to 1.50M above from PCC coping and aluminium painting on all mild steel clamps, cross arm etc on poles with and including premium quality aluminium paint after necessary preparation of all surfaces of poles & fixures and fittings complete all as specified and as directed. Note:- All necessary T&P required at site for painting shall be arranged by contractor at his own cost and quoted rate shall be deemed to be included for all these provisions and nothing extra shall be paid on this account.
M&L for painting of alternate black & white strips to two pole structure consisting of two steel tubular poles/ rail poles of HT/ LT of over head lines with and including synthetic enamelled paint, total 05 Nos each strips on each pole, each strip having 0.15M height total up to 1.50M above from PCC coping and aluminium painting on all mild steel clamps, cross arm etc on poles with and including premium quality aluminium paint after necessary preparation of all surfaces of poles & fixures and fittings complete all as specified and as directed. Note:- All necessary T&P required at site for painting shall be arranged by contractor at his own cost and quoted rate shall be deemed to be included for all these provisions and nothing extra shall be paid on this account.
M&L for painting of alternate black & white strips to steel tubular poles/ rail poles of HT/ LT of over head lines with and including synthetic enamelled paint, total 05 Nos each strips on each pole, each strip having 0.15M height total up to 1.50M above from PCC coping and aluminium painting on all mild steel clamps, cross arm etc on poles with and including premium quality aluminium paint after necessary preparation of all surfaces of poles & fixures and fittings complete all as specified and as directed. Note:- All necessary T&P required at site for painting shall be arranged by contractor at his own cost and quoted rate shall be deemed to be included for all these provisions and nothing extra shall be paid on this account.
Supply and fixing of new over current and earth fault relay having auxilary voltage 24-110 Volts + 15% AC/ DC after taking out the old unserviceable relay and testing on completion complete all as directed. Make:- Cat No. MC 61 of L&T or equivalent model of make- Schneider or any other make as approved by GE.
Supply and fixing of new digital multifunctional meter having model No. EM 6459, 0.5RS of make- ENERCON as per existing Meter duly approved by Engr-in-Charge complete all as directed.
Supply and fixing in replacement ZZ switch, trip circuit healthy of VCB and testing on completion complete all as specified and as directed.
Supply and fixing of new indicator lamp with holder for various control panels/ VCB panels as per existing make/ as per manufacturer's instructions duly approved by Engr-in-Charge after taking out the old unserviceable switch and testing on completion complete all as directed.
Supply and fixing, in replacement, common alarm relay voltage range 24-30V, DC of VCB as per existing one at site and testing on completion complete all as specified and as directed.
Supply and fixing in replacement microprocessor numerical relay of VCB as per existing one at site and testing on completion complete all as specified and as directed.
Supply and fixing in replacement self powered protection relay of RMU and testing on completion complete all as specified and as directed.
Supply and fixing in replacement digital multifunction meter for 11 KV RMU and testing on completion complete all as specified and as directed.
Supply and fixing in replacement shunt tripping coil of RMU as per existing one at site and testing on completion complete all as specified and as directed.
Supply and fixing , in replacement, load break switch mechanism assembly having two position spring assisted, Integrated line earthing switch making capacity and testing on completion complete all as specified and as directed.
Supply and fixing, in replacement, isolator switch mechanism assembly having two position spring assisted, Integrated line earthing switch making capacity as per existing one at site and testing on completion complete all as specified and as directed.
Supply and fixing in replacement master trip relay as per existing one at site and testing on completion complete all as specified and as directed.
Supply and fixing, in replacement, SF6 gas of VCB as per existing specification and testing on completion complete all as specified and as directed.
Supply and fixing, in replacement, capacitor bank , 50 KVAR, Type PP, Cn 2.68, 50 Hz, Un-7.7 KV, Insulation level 28/75 KV, single pole, outdoor type, suitable for fixing in series in 33 KV gantry and testing on completion complete including taking down old unserviceable capacitor bank complete all as specified and as directed.
S&F the rubber matting, ISI marked, not less than 2x1 mtr in size, 25mm thick complete all as required and directed at site
Supply and fixing of new post insulator for Air Break switch suitable for HT 33/36 KV as per existing make/ as per manufacturer's instructions duly approved by Engr-in-Charge after taking out the old unserviceable insulator and testing on completion complete all as directed.
Supply and fixing of sealed maintenance free battery 12V, 150 AH including making all necessary connections after taking out the old unserviceable battery and testing on completion complete all as directed. Make:- Exide or Amco or Amaron or Luminous as approved by GE.
S&F spring charging motor AC / DC of VCB trolley as per existing sample and testing on completion complete all as specified and as directed.
Supply and fixing, in replacement, motor cut off for spring charging motor of VCB trolly of Make & specifications as per existing one at site and testing on completion complete all as specified and as directed.
Supply and fixing power pack with input 220-110V,AC and output 24V, DC for VCB trolly of Make & specificatins as per existing one at site including taking down power pack as exists at site and testing on completion complete all as specified and as directed.
Supply and fixing closing coil 24 V, DC for VCB trolly of Make & specificatins as per existing one at site after taking down closing coil as exists at site and testing on completion complete all as specified and as directed.
Supply and fixing shunt tripping coil 24 V, DC for VCB trolly of Make & specificatins as per existing one at site after taking down shunt tripping coil as exists at site and testing on completion complete all as specified and as directed.
Supply and fixing, in replacement, electronic hooter of VCB and testing on completion complete all as specified and as directed.
Supply and fixing, in replacement, HRC fuse base with HRC fuse 20A,415V,80 kA and testing on completion complete all as specified and as directed.
Supply and fixing, in replacement, spring charging gear assembly for VCB trolly of Make & specifications as per existing one at site complete all as specified and as directed.
S&F control wiring with 1.5 sqmm single core FRLS PVC insulated copper flexible cable for control circuits and 2.5 sqmm single core FRLS PVC insulated copper flexible cable for CT circuits as per existing diagram including provision of cable ties, beading etc of VCB or RMU complete all as specified and directed
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 11000 volts(Earthed) grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor of cross section area 95 sqmm, 3 core after taking out the old unserviceable XLPE/ PILCA cable and testing on completion complete all as directed. Make:- Havells or Finolex or Gloster or Plaza or Universal as approved by GE.
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 11000 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor of cross section area 120 sqmm, 3 core after taking out the old unserviceable XLPE/ PILCA cable and testing on completion complete all as directed. Make:- Havells or Finolex or Gloster or Plaza or Universal as approved by GE.
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor of cross section area 120 sqmm, 3.5 core and testing on completion complete all as directed. Make:- Havells or Finolex or Gloster or Plaza or Universal as approved by GE.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95sqmm to 120sqmm and testing on completion complete all as directed. Make:- M SEAL or RAYCHEM or DENSON or CAB SEAL as approved by GE.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95sqmm to 120sqmm and testing on completion complete all as directed. Make:- M SEAL or RAYCHEM or DENSON or CAB SEAL as approved by GE.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50sqmm to 95sqmm and testing on completion complete all as directed. Make:- M SEAL or RAYCHEM or DENSON or CAB SEAL as approved by GE.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185sqmm and testing on completion complete all as directed. Make:- M SEAL or RAYCHEM or DENSON or CAB SEAL as approved by GE.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185sqmm and testing on completion complete all as directed. Make:- M SEAL or RAYCHEM or DENSON or CAB SEAL as approved by GE.
M&L for cable jointing kit for 33 KV (Earthed) grade cable for outdoor cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185sqmm and testing on completion complete all as directed. Make:- M SEAL or RAYCHEM or DENSON or CAB SEAL as approved by GE.
Relaying or refixing or repassing in trenches/ on poles/ through pipes after taking out/ taking down the existing HT 11000 volts grade PILCA/ XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor of cross section area 95/120 sqmm, 3 core from trenches/ poles/ pipes and testing on completion complete all as directed. Notes:- (i) Excavation and earth work shall be measured and paid for separately under respective items. (ii) Joints shall be measured and paid seprately under respective items. (iii) Taking out/ taking down shall be done only after disconnecting all the connections of the cable from over head lines and panels.
Dismantling of HT PCC electric poles/struts of any section & any size after dismantling of PCC coping, making necessary excavation and earth work, opening of MS cross arms/ clamps, insulators and carefully taking down of existing over head copper conductors or aluminium conductor as required including removal from site as directed.
Supply and fixing 11.0 M long steel tubular swaged pole type 410 SP-55 complete with cast iron base plate, finial taper plug, nuts, bolts, screws and washers all as specified including two coats of painting with black bituminous paint upto embedded portion before fixing of poles and two coats of painting with aluminium paint over a coat of primer on exposed surface after fixing complete all as shown in TD drawing No. CEJZ/TD/824/91, Sht No1/2 dt 16.04.91 including following items/ works complete:- (a) Excavation in post holes in any types of soil, returning fillingin, well ramming and disposal of surplus soil to a distance not exceeding 50M from the starting points complete all as specified and directed. (b) PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation up to ground level complete all as specified and directed. (c) PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in copings/ collars, bed plates, plinth block etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed. (d) M&L for writing letters or figures (Block, Roman, Italic or Indian) with and including thick enamel paint of approved shade not exc 5cm in height complete all as specified and directed. Make:- NATIONAL TUBING CO. or JINDAL or BHARAT ISPAT UDYOG or JAI BHARAT POLES as approved by GE.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised iron strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore GI pipe light grade including necessary fittings for protection of earthing strip, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge 8 mesh per linear including 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS TMT bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth strip alongwith protection pipe and testing on completion complete all as specified and directed. Note:- GI strip and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor.
Supply and fixing of new pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mils steel spindle, two galvanised iron washers and one galvanised iron nut, suitable for 33KV grade (main receiving station) after taking out the old unserviceable insulator complete all as specified and directed.
Supply and fixing of new disc type, porcelain, vitreous, white, brown or green insulator of 145mm height and 225mm dia including all necessary hard ware suitable for 33KV grade (main receiving station) after taking out the old unserviceable insulator complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point including spreading complete all as specified and directed.
M & L for 40mm crushed stone aggregate, laying and spreading complete all as required at site and as directed
Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. ( Note : Punned thickness shall be measured. )
Supply and laying un-reinforced precast concrete cable covers, Class HVP type I, with peak, size 300 mm x 180 mm x 40 mm, complete all as specified and as directed.
Supplying and fixing/ laying of 80mm bore dia GI pipe light grade in trenches/ under roads/ along pole/ wall including all fittings, ISI marked as required for cable protection including dismantling of old unserviceable GI pipe complete all as specified and directed.
Drilling (Horizontally) to existing road (maximum 10M wide) suitable for passing GI tubing of dia upto 80mm/ 100mm as required at site complete all as specified and directed. Note:- All necessary T&P required at site for drilling shall be arranged by contractor at his own cost and quoted rate shall be deemed to be included for all these provisions and nothing extra shall be paid on this account.
Supply, fixing and stretching of new aluminum conductor, steel reinforced on LT poles including copper binding wires or aluminium tape after taking out the old unserviceable aluminium conductor of any size complete all as specified and directed.
M&L for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint after taking out the old unserviceable cross arms, bracing, supports etc of any section complete all as specified and dircted.
M&L for anti climbing device; spikes type fabricated out of MS bars (round, square and flat) including bolts, buts, washers and welding in two halves made to shape to suite the cross section of the pole after taking out the old unserviceable anti climbing device of any description complete all as specified and dircted.
Supply and fixing of new pin type porcelain, vitreous, white/ brown/ green insulator 150mm high and 150mm dia including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, suitable for HT 11000 volts after taking out the old unserviceable insulator complete all as specified and directed.
Supply and fixing of new disc type insulator, porcelain, vitreous white/ brown/ green 145mm high and 225mm dia ball & socket type single disc assembly for tension with GI tension clamps for conductors for working pressure of 11000 volts after taking out the old unserviceable insulator complete all as specified and directed.
Supply and fixing of new switch air break gang operated triple pole mechanically operated out door with all fittings/ accessories mounted on & including porcelain insulators and steel frame with operating mechanism worked from ground level, horizontally operated, with & including operating rod of 25mm dia GI pipe medium grade (ISI marked) with MS handle with locking arrangement, for current rating up to 200 Amp 11000 Volts including drop out fuses of suitable capacity to suit gang operated triple pole 11 KV switch, connecting, commissioning after taking out the old unserviceable switch air break and testing on completion complete all as specified and directed. Make:- JAIPURIA or PACTIL or BHEL or MEI as approved by GE.
Supply and fixing of new switch air break gang operated triple pole mechanically operated out door with all fittings/ accessories mounted on & including porcelain insulators and steel channel frame on existing 2/4pole structure with operating mechanism worked from ground level, horizontally operated, with & including operating rod of 25mm dia GI pipe medium grade (ISI marked) with MS handle with locking arrangement, for current rating up to 400 Amp 11000 Volts including drop out fuses of suitable capacity to suit gang operated triple pole 11 KV switch, connecting, commissioning after taking out the old unserviceable switch air break and testing on completion complete all as specified and directed. Make:- JAIPURIA or PACTIL or BHEL or MEI as approved by GE.
Supply and fixing of new switch air break gang operated triple pole mechanically operated out door with all fittings/ accessories mounted on & including porcelain insulators and steel channel frame on existing 2/4 pole structure with operating mechanism worked from ground level, horizontally operated, with & including operating rod of 25mm dia GI pipe medium grade (ISI marked) with MS handle with locking arrangement, for current rating up to 400 Amp 33000 Volts including drop out fuses of suitable capacity to suit gang operated triple pole 33 KV switch, connecting, commissioning after taking out the old unserviceable switch air break and testing on completion complete all as specified and directed. Make:- JAIPURIA or PACTIL or BHEL or MEI as approved by GE.
M&L for new lightning arrestor expulsion type complete with all fittings, transmision/ distribution class 30 KA, conforming to IS-3070 (Part-III) 1993 and mounting on poles including all necessary bolts, nuts and washers and making electric connection after taking out the old unserviceable lightning arrestor and testing on completion complete all as specified and directed. Make:- SCHNENIDER or BHEL or GE POWER or W/S INSULATORS or SOUTHERN INSULATORS as approved by GE.
Routine and periodical cleaning of inside area of 11 KV Sub Stations including cutting and removal/ uprouting of unwanted grass/ bushes, small trees near all around sub station and pump houses complex complete including surface dressing and leveling by surface excavation and removal of debris to out side MD land wherever as required or as directed by Engineer-in-Charge.
Schedule of credit amount of Rs. 51,855.00 to be deducted during AOC
R K TRANSFORMER
Sachdeva Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .