| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹83.4 LAccepted-AOC 102 R RESIDENCY PLOT 39 SEC 19 BEHIND HOTEL MALWAN ULWE NODE NAVI MUMBAI | NAVI MUMBAI | MAHARASHTRA | L1 | Accepted-AOC L1 | |
| 2 | L2₹95.8 L+₹12.4 L (14.9%)Rejected-AOC ADHYARU INDUSTRIAL EST STORE NO 3 1ST FLOOR SUN MILL COMPOUND LOWER PAREL MUMBAI 400013 | MUMBAI | MUMBAI | MAHARASHTRA | 400013 | L2 | Rejected-AOC L2 | |
| 3 | L3₹1.0 Cr+₹21.5 L (25.8%)Rejected-AOC NO 3 BALAKRISHNA BUILDING NG ACHARYA MARG CHEMBUR MUMBAI MUMBAI MAHARASHTRA 400071 | MUMBAI SUBURBAN | MAHARASHTRA | 400071 | L3 | Rejected-AOC L3 | |
| 4 | L4₹1.1 Cr+₹21.9 L (26.3%)Rejected-AOC OFFICE NO 206 D WING EXTENSION RAIKER CHAMBERS DEONAR VILLAGE ROAD GOVANDI EAST MUMBAI 400088 | MUMBAI | MUMBAI | MAHARASHTRA | 400088 | L4 | Rejected-AOC L4 | |
| 5 | L5₹1.2 Cr+₹33.2 L (39.8%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹1.1 Cr
Closing Date
29 Dec 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer (GSS)
3rd Floor, V.S.Bhavan, Anushaktinagar, Mumbai-400094
Replacement of old MS street light poles and associated works at Anushaktinagar and Old Mandala colonies, Mumbai
2021_DCSEM_662733_1
DCSE/CQD/QSC/GSS/21-22/NIT-18 dt.09.12.2021
Open Tender
Electrical Works
Item Rate
180 days
Anushaktinagar and Old Mandala, Mumbai
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
Exempted
12 May 2022
15 Dec 2021
30 Dec 2021
15 Dec 2021
29 Dec 2021
15 Dec 2021
15 Dec 2021 - 22 Dec 2021
120 days
Amount
Street light poles
Fabrication, supply, installation of 11 mtrs. bracket type high swaged ERW hot dip galvanized MS tubular pole (410SP-49) as per IS 2713-1980 for pole with pipe material as per IS 1161 grade Yst-240 part II with MS base plate of 460mm x 460mm x 12 mm, 4 nos. of 150mm length MS webs made up of 5 mm thick MS plate shall be provided between pole & base plate, 2 nos. of 10 mm dia. G.I. earthing studs welded to pole, 900mm long 5mm thick MS collar welded to the pole ,the pole and the bracket shall be hot dipped galvanized after fabrication minimum of 65 micron thickness, pole shall be embedded 1800 mm below ground level in all types of soil/rock with 1:2:4 PCC on 150 mm thick 1000 mm, square base concrete, upon that 1800 mm depth 750 mm square base concrete up to ground level & 350 mm dia. 300 mm high coping above ground level around the pole in level, plumb line & plaster finish, terminal boxes mounting arrangement shall be made on the pole 1500 mm from ground level. Earthing of street light pole with 2 nos. of 8 SWG G.I. earth wires each 8 M long coiled at a depth of 1800 mm below ground level and connected to the pole. Scope also includes excavation in all types of soil/foot path cutting,treatment of pole with bituminous preservatives for embedded portion for 2 meters from base plate of the pole, 50mm dia. 2meter length HDPE pipe - 2nos. for enrty of cable, pole numbering with paint all as per above specifications and instruction of E.I.C.
Fabrication, supply, installation of 9 mtr. bracket type high swaged ERW MS tubular pole (410SP-28) as per IS 2713-1980 for pole with pipe material as per IS 1161 grade Yst-240 part II with MS base plate of 460mm x 460mm x 12 mm, 4 nos. of 150mm length MS webs made up of 5 mm thick MS plate shall be provided between pole & base plate, 2 nos. 10 mm dia. G.I. earthing studs welded to pole, 900mm long 5mm thick MS collar welded to the pole , hot dipped galvanized, Pole shall be embedded 1500 mm below ground level in all types of soil/rock with 1:2:4 PCC on 150 mm thick 1000 mm square base concrete, upon that depth 1500 mm, 750 mm square base concrete upto ground level & 350 mm dia 300 mm high coping above ground level around the pole in level, plumb line & plaster finish, under protection terminal boxes mounting arrangement shall be made on the pole 1500 mm from ground level. Earthing of street light pole with 2 nos. of 8 SWG G.I. earth wires each 8 M long coiled at a depth of 1500 mm below ground level and connected to the pole. Scope also includes excavation in all types of soil/foot path cutting, treatment of pole with bituminous preservatives for embedded portion for 2 meters from base plate of the pole, 50mm dia. 2meter length HDPE pipe - 2nos. for enrty of cable, pole numbering with paint all as per above specifications and instruction of E.I.C.
Design, manufacture, testing at works,supply, assembling, installation, and erection of single arm 6 m (above ground level ) Octagonal pole internally & externally hot dipped galvanised, fabricated out of 3mm thick sheet as per S355JO or relevant I.S, complete with built in junction box, base plate size 200 X 200 X12 mm, one arm of galvanised pipe of 32 NB medium class and 1.0Mtr in length on one side of pole shaft with 15deg. up angle with horizontal as per detailed specifications. Junction box should be provided 500 mm above base plate with 4 Nos brass terminals on epoxy insulator, 1 no 6A SP MCB (will be supplied by dept. free of cost) & 1 no. neutral link mounted on 4 mm thick bakelite sheet, 2mm GI gland plate, suitable arrangement for atleast 3 nos. of 4Cx10sqmm etc. Base plate should have 4 nos holes suitable for mounting on RCC foundation as per standard drawing 200 mm above FGL. The cost of pole shall include the cost of RCC foundation , foundation bolts, anchor plates, nuts, washers, min 2 nos. HDPE PLB pipe 40/33 mm dia bend to shape approx. 1.0 m in length, & including excavation in all types of soil/foot path cutting , temporary reinstatement, back filling, dewatering, consolidation, disposal of excess earth within the radius of 3000 m and making good to the original finish etc as per enclosed detailed specifications & drawings, as required to complete the work in all respect as per instructions of the E-I-C. Note: For foundation please refer standard drawing 4-6 meter pole
Only installation of 11 mtrs. bracket type hot dip galvanized MS tubular pole with bracket, pole shall be embedded 1800 mm below ground level in all types of soil/rock with 1:2:4 PCC on 150 mm thick 1000 mm, square base concrete, upon that 1800 mm depth 750 mm square base concrete up to ground level & 350 mm dia. 300 mm high above ground level around the pole in level, plumb line & plaster finish, terminal boxes mounting arrangement shall be made on the pole 1500 mm from ground level. Earthing of street light pole with 2 nos. of 8 SWG G.I. earth wires each 8 M long coiled at a depth of 1800 mm below ground level and connected to the pole. Scope also includes excavation in all types of soil/foot path cutting,treatment of pole with bituminous preservatives for embedded portion for 2 meters from base plate of the pole, 50mm dia. 2meter length HDPE pipe - 2nos. for enrty of cable, pole numbering with paint all as per above specifications and instruction of E.I.C. Note: The poles dismantled under Item No.12 shall be used for installation.
Only installation of 9 mtr. bracket type hot dipped galvanizedMS tubular pole with bracket, Pole shall be embedded 1500 mm below ground level in all types of soil/rock with 1:2:4 PCC on 150 mm thick 1000 mm square base concrete, upon that depth 1500 mm, 750 mm square base concrete upto ground level & 350 mm dia 300 mm high above ground level around the pole in level, plumb line & plaster finish, under protection terminal boxes mounting arrangement shall be made on the pole 1500 mm from ground level. Earthing of street light pole with 2 nos. of 8 SWG G.I. earth wires each 8 M long coiled at a depth of 1500 mm below ground level and connected to the pole. Scope also includes excavation in all types of soil/foot path cutting, treatment of pole with bituminous preservatives for embedded portion for 2 meters from base plate of the pole, 50mm dia. 2meter length HDPE pipe - 2nos. for enrty of cable, pole numbering with paint all as per above specifications and instruction of E.I.C. Note: The poles dismantled under Item No.12 shall be used for installation.
Bracket for poles
Fabrication, supply & installation of hot dip galvanized MS pole single arm bracket of 1500 mm. long 32mm NB medium pipe welded on 100 NB medium pipe as per IS 1239 pipe for an overlap length of 1200 mm over the pole, the bracket shall be at an angle 15˚ up from the horizontal, 5 mm thick 300 mm MS web, 3 sets of 3 nos. 8mm of GI nut-bolts for fixing arrangement , pole mounting cap of 150 mm. long suitable for overlap section with nut-bolts for fixing arrangement
Fabrication, supply & installation of hot dip galvanized MS pole double arm bracket of 1500 mm. long 32mm NB medium pipe welded on 100 NB medium pipe as per IS 1239 pipe for an overlap length of 1200 mm over the pole, the bracket shall be at an angle 15˚ up from the horizontal, 5 mm thick 300 mm MS web, 3 sets of 3 nos. 8mm of GI nut-bolts for fixing arrangement , pole mounting cap of 150 mm. long suitable for overlap section with nut-bolts for fixing arrangement
Fabrication,supply,fixing of hot dipped galvanised MS angles/flats /channel of required sizes & as per site requirement including fixing with suitable size of G.I. fixing fasteneners on pole / wall/ceiling etc. for electrical installtions/cables etc.
Supply, installation, testing and commissioning of 1.1 kV grade PVC/XLPE insulated, inner sheath PVC tapped and outer sheath extruded PVC, multi stranded aluminum conductor, GI strip armoured 4 C x 10 sq. mm aluminum conductor cable power cable, conforming to relevant IS’s, fixed on wall/columns/slab in existing hume pipe/trench/G.I. sleeves/pipes or on 5 mm thick hot dip GI flats/4mm thick hot dip G.I. spacer/GI angle support fixed with coach screws grouted in wall/anchor fasteners / 2 mm thick hot dip G.I. fabricated saddle, all fixing accessories/in existing trench at a depth of 900 mm below ground level including excavation in all types of soils/soft rock if any, sand bedding, laying of baked bricks as per IS on side and top, including consolidating, temporary reinstatement, back filling, dewatering, if necessary, disposal of excess earth within the radius of 3000 mtrs, all as per drawings, specifications, and as per instructions of E.I.C.
In ground in all types of soil including excavation.
In existing RCC hume pipes/G.I. pipes trench/wall/beam/column with necessary spacers/saddles/MS clamps etc.
End jointing of 4 C x 10 sq. mm / 4C x 16sq. mm aluminum conductor cable by crimping, with supply of all jointing materials like solder less heavy duty tinned copper socket, long nipple cable gland, insulation tape, flux, Suitable brass earth tag for duplicate earthing for cable gland with 8SWG GI wires interconnecting GI pole/Al. pole and as per the instructions of E.I.C.
Supply, installation, testing & commissioning of External terminal box of aprox. size 300 x 200 x 125 mm made of FRP/SMC of M/s. Syntax / M/s. Hensel make complete with front openable cover with SS allen-key screw locking arrangement, 2 mm thick hot dipped GI gland plate, water proof gasket, 32A, 4 way, 415V resin cast stud type connector suitable termination cable of size 16 sq. mm, SP MCB 6A -1no. (supplied by dept) mounted in the box with channel etc. including 2nos. clamping arrangement made up of 25 x 3mm hot dipped G.I strip for mounting on street light pole with suitable GI nut-bolts etc. as per the instructions of E.I.C.
Supply & installation of 50 mm dia. HDPE pipe with all fixing arrangement to above poles & across drains/road with necessary fixing arrangements and all as per the instructions of E.I.C.
Supply & installation of RCC hume pipes of 150 mm Φ(non pressure type) jointing with collars & necessary mortar, including excavation in soft soil and as per instructions of Engineer-in-charge
Earthing of octagonal poles with 25mm class B GI pipe of 1.5M length installed bellow ground level and to be coonected to pole using 8SWG GI wire to existing foundation bolts and as per instructions of Engineer-in-charge
Supply, installation, testing & commissioning of following LED luminaries having a minimum efficacy of 130 lm/watts with cool white/ neutral white colour temperature & pressure die cast Aluminium housing having IP65 protection etc. All the accessories shall be housed in side light fixture with suitable connector. Scope also includes providing interconnection with 3Cx2.5 sq. mm copper conductor PVC insulated PVC sheathed flexible cable, earthing of fixture etc. (Independent wiring to be done for each fixture from external terminal box). Note: The fixture to be got approved by department before manufacturing/supply. The fixtures shall have replacement warranty of 5 years from date of supply. Warranty certificates shall be submitted to department at the time of supply. Scope work also includes dismantling of the exisitng fixtures and depositing the same in DCSEM stores.
Street light LED luminaries having minimum output of 11000 lumens and efficacy of 130 lm/watts.
Street light LED luminaries having minimum output of 13000 lumens and efficacy of 130 lm/watts.
LED flood light luminaries having minimum output of 17000 lumens and efficacy of 130 lm/watts.
Only installation of dept. supplied Street light LED luminaries.
Earth excavation in hard rock/soft rock & breaking the existing drain walls & reinstatment
Excavating of soft soil including shorting or dewatering, removing of bricks/tiles etc. refilling and consolidation of the surface. Disposing the excess earth within a 3000 meter radius as directed by engineer-in- charge.
Cutting of asphalt road / concrete flooring /drain of 200 mm depth by using hydraulic drilling machine as required and stacking of rocks, refilling and consolidation of the surface. Disposing the excess earth within a 3000 meter radius as directed by engineer-in-charge
Excavating in hard rock including shorting or dewatering, removing of bricks/tiles etc. refilling and consolidation of the surface. Disposing the excess earth within a 3000 meter radius as directed by engineer-in- charge.
Providing Plain cement concrete 1:3:6 using graded stone aggregate of 20 mm maximum size including consolidation, stacking, soling, frame work, shuttering, finishing, curing etc. Complete all as directed by Engineer in charge. Complete all as per specification & as directed by EIC.
Breaking of Concrete foundation of 9M/11M tubular pole (street light) including dismantling of poles with due safety to avoid any damage to pole /GI pipe,including excavation of sorrounding area as required for breaking of foundation size of approx. 750mm x 750mm x 1500mm to 1800mm including disposing the excess concrete within a 3000 meter radius as directed by Engineer-in-charge. Scope also includes transportation of dismantled poles to desired locations in Aushaktinagar for installation against Item No.1.4 & 1.5
Disconnection and dismantling of existing 11M / 9M M.S pole with bracket and light fixture. Dismantled materials like M.S pole, bracket, terminal boxes, cables, lighting fixtures etc. to be deposited at DCSEM stores/ TV stores including loading, unloading and arrangement of suitable vehicle. Measurement will be made based on per removed pole is equal to one job.
Removing and relaying of old Shahabad stone and paver blocks (60/ 80 mm thick) with care with out causing any damages to adjacent footpath and paved area etc , stacking properly the serviceable materials and disposal of unserviceable materials within 150 m lead all as per specification and as per direction of Engineer-in-charge.
Ramesh Electrical and Mechanical Works
K Sharma Electricals Private Limited
Arathi Electricals
MAHITHA ELECTRO TECHNICS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .