GE(WEST)PATHANKOT
GE(WEST)PATHANKOT
SPL REPAIR TO ROOF TREATMENT AND TOILET OF BLDG NO NP-07 OF 14 WE BN UNDER GE (WEST) PATHANKOT
2026_MES_794021_1
GE/PKT-72/2026-27
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (WEST) PATHANKOT
As per NIT and tender documents
8 documents required · 8 mandatory
₹500
GE(WEST)PATHANKOT
₹93,200
12 Nov 2026
15 Oct 2026
14 Nov 2026
15 Oct 2026
12 Nov 2026
29 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Sch 'A' Part-I B/R Portion
M&L liquid water proofing treatment to RCC roof slab including dismantling of existing roof treatment of any description such as worn-out tar felt, debris, mortar of any description & any thickness, surface cleaning of all foreign material such as shrubs/roots, fungus, moss, dust including plaster, APP membrane etc. including disposal of debris out of MoD land : (a) Prepare the surface by cleaning the surface and making free of dirt, foreign particles, laitance followed by grinding all protrusions to make surface modulated, thereafter, inspection for cracks on the surface caused by thermal expansion, contraction. Cutting the grooves with suitable cutter machine in "V" groove filled with Repair mortar/micro concrete/General purpose grout as recommended proportionally as per recommendation of manufacturer. Making of Gollas at all the corners with Polymer modified mortar (1:4 Cement: sand with acrylic polymer 3.5% by weight of cement) complete all as specified.
(b) Laying 10mm thick rendering in Cement mortar 1:3 with liquid water proofing compound (as per manufacturer’s instructions) on fair faces of concrete roof surfaces, finished even and fair to receive treatment on roof Complete
(c) Supplying and applying High performance Hybrid Polyurea waterproofing coating spray/hand applied liquid membrane with following specifications:
(i) Elongation of range 400% to 600%, (ii) Tensile strength of 8-12 N/mm2, (iii) Crack bridging ability of 3.00-4.00mm, (iv) Hardness (Shore 'A' ASTM D2240) of range 50-70.
The application shall include epoxy primer application in ratio 1:1 (resin: hardener) with 100% water dilution and laying of fiber mesh 1.5 mm thick wave in leno pattern laying weight 4.5gm/Sqm and painting it properly with overlap of 50 mm, and allowing it to dry before application of Hybrid polyurea in two coats in 6 hrs interval to achieve total min thickness 1 to 1.50mm.
The application/ treatment shall be carried out by authorized rep of approved specialist firm/manufacturer. | 1,250 | Sqm | - | - |
| 2 | Taking up or down, 15mm dia bore, GI tubing, medium grade, including removal from site, complete all as specified and as directed by Engineer-in-Charge. | 75 | RM | 2 | ₹150 |
| 3 | Taking up or down, 20mm dia bore, GI tubing, medium grade, including removal from site, complete all as specified and as directed by Engineer-in-Charge. | 75 | RM | 3 | ₹225 |
| 4 | S&F 15mm bore steel tubing medium grade galvanised with all fittings and fixed complete to walls or laid in floors complete all as directed by Engr-in-Charge | 75 | RM | 4 | ₹300 |
| 5 | S&F in 20mm tubes medium grade galvanised with all fittings and fixed complete to walls or laid in floors bore of pipe complete all as specified and directed | 75 | RM | 5 | ₹375 |
| 6 | Cutting chases ,pinning in making good to facing where required of brick walls and pointed in cement mortar 1:3 for concealed water tubing etc cutting not exc 10 cm girth. | 75 | RM | 6 | ₹450 |
| 7 | Disconnecting existing 500 ltr capacity of rotational moulded PVC water storage tank, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) , alongwith tank nipple , inlet outlet pipe and all connected fittings. | 10 | Each | 7 | ₹70 |
| 8 | S&F rotational moulded PVC water storage tank three layers of 1000 ltrs capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including inlet & outlet tank nipple 20 mm thick ball valve high pressure of PTMT with epoxy coated aluminium rod and high dinsity plastic bal screwed for iron pipe and fixed ( Minimum weight 20mm-210 gms including dismantling of old broken water tanks and refixing of inlet , outlet & over flow pipe etc complete all as specified and directed. | 5 | Each | 8 | ₹40 |
| 9 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting and reconnecting and re-fixing in position (Cleaning repairing etc. measured separately) exc 500 and n.exc 1000ltr incl all fittings | 4 | Each | 9 | ₹36 |
| 10 | Taking up or down PVC pipe incl all connections such as PVC bend, tee, etc , of 110/75 mm dia complete all as apecified | 50 | RM | 10 | ₹500 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
tender72.pdf
Tender Documents • 1.70 MB
BOQ_890510.xls
BOQ • 0.80 MB
72Coor1.pdf
PDF • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .