| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹17.2 L+₹1.4 L (8.73%)Rejected-Finance | L2 | Rejected-Finance Rejected being 2nd Lowest Bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical NO Slow Progress remarked in WLR of QE Mar 2020 submitted by GE Faridkot |
Tender Value
₹20.9 L
EMD Value
₹41,900
Closing Date
2 Jul 2020, 6:00 pmClosed
COMMANDER WORKS ENGINEER, SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO. CWE SGNR-68 OF 2019-20 SPECIAL REPAIRS TO BUILDING NO. P-44 (HERITAGE BUILDING) AT MILITARY STATION FARIDKOT
2020_MES_323901_1
CA NO. CWE SGNR - 68 OF 2019-20
Open Tender
Civil Works
Item Rate
180 days
FARIDKOT
Class E
Category a(i)
10 documents required · 10 mandatory
₹500
GE FARIDKOT
₹41,900
Yes
28 Jul 2020
26 May 2020
4 Jul 2020
26 May 2020
2 Jul 2020
18 Jun 2020
Amount
Taking down of chowkats or frames n.exc 1.5 Sqm each with shutters (without taking of shutters from the frames) complete all as specified and directed by Engineer-in-Charge.
Taking down of chowkats or frames exc 1.5 Sqm but n exc 4 sqm each with shutters (without taking of shutters from the frames) complete all as specified and directed by Engineer-in-Charge.
M&L for Taking down & Refixing of Shutter in same opening of any description exc 1 sqm nexc 2Sqm each complete all as specified and directed by Engineer-in-Charge.
M&L for mild steel framed work of Fe-290 (Gde E-165) as in grills/guard bars shouldered with steel windows/ventilators frames. Cooler stand, ladder etc including redoxide primer coat complete all as specified and directed by Engineer-in-Charge.
S&F for Anodised aluminium door/window shutters (Power coating of any colour) , aluminium section weighting .55 kg/m including necessary joining cleats , glazing clips, rubber packing , anodised aluminium snap beading , screws, rubber neoprene packing, handle 2 nos in each door, hinges, locking arrangement ,heavy duty hydraulic door closer , stopper of any size etc complete all as specified and directed by Engineer-in-Charge.
S&F for 4.8 mm thick frosted (tuffen glass) sheet glass ordinary quality and glazing with oil putty/any type of beading in square n exc 0.5 sqm in each pane window/ ventilators complete all as specified and directed by Engineer-in-Charge.
S&F for Anodised aluminium frame(power coated of any colour) for door , window ,ventilators or frame with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engineer-in-Charge.
S&F for aluminium anodized handles 150mm long dia "D" type fixed to doors with screws complete all as specified and directed by Engineer-in-Charge.
M&L for preparationof new or previously untreated steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
S&F for Solid wood moulded grain printed PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. Square tube, egdes will be painted to match printed sheets, in opening as per specification complete all as specified and directed by Engineer-in-Charge.
S&F for Factory made 28 to 30 mm thick stiles with 2,4 or 6 raised panel design with particle board core and 2 mm thick 3 D wood grain moulded PVC Sheet polyurethane painted on the front face & 2 mm plain colour PVC sheet on back face complete all as specified and directed by Engineer-in-Charge.
S&F for 150 mm long Aluminium handles cast type anodised complete all as specified and directed by Engineer-in-Charge.
S&F for 200 mm long Aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge.
S&F for 125 mm long Aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge.
S&F for 250 mm long aluminium alloy, anodised, sliding door bolt with hasps staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extuded sections or cast aluminium alloy and fixed complete all as specified and directed by Engineer-in-Charge.
S&F for 140 mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new or previously untreated steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
S&F in repair MS powder coated decorative drapery rod (colour as approved) of 20mm dia approved pattern & design including decorative knobs (wall side and free side) & powder coated mild steel flat iron brackets fixed with steel screws & PVC rawl plugs/grips complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C0 using (12.5mm graded aggregate) as in back filling of pressed steel frames, bed blocks, coping, fixing of hold fasts etc including necessary formwork complete all as specified and directed by Engineer-in-Charge.
Demolition of concrete (unreinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed by Engineer-in-Charge.
M&L for Vitrified ceramic tiles 10mm thick (Square/rectangular) light shade polislhed area of each tiles not exceeding 0.36 Sqm in floors set and jointed in neat cement slurry and pointed in coloured cement to match, 15mm thick screed bed or bedding layer CM 1:4 for laying finishes complete all as specified and directed by Engineer-in-Charge.
M&L for Vitrified ceramic tiles 10mm thick (Square/rectangular) light shade polislhed area of each tiles not exceeding 0.36 Sqm in skirting/dado set and jointed in neat cement slurry and pointed in coloured cement to match, 10mm thick CM 1:4 for laying finishes complete all as specified and directed by Engineer-in-Charge.
S&F for Non skid ceramic tiles 7 to 8 mm thick (square/rectangular) (coloured tiles) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors set and jointed in neat cement slurry and pointed in coloured cement to match the coloured tiles15mm thick screed bed or bedding layer CM 1:4 for laying finishes, complete all as specified and directed by Engineer-in-Charge.
S&F for Glazed ceramic tiles (coloured tiles) in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 15 mm thick rendering in CM 1:4 on fair face of brick work complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 50mm thick type C2, 1:3:6 using 20mm graded aggregate as in plinth protection/path finishing surfaces even and fair (without using extra cement) complete all as specified and directed by Engineer-in-Charge.
M&L for taking down of cement plaster and rendering 15 mm thick in cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for taking down of cement plaster and rendering 15 mm thick in cement plaster 1:4 on surface other than fair face of brickwork or stone masonry surfaces or on one side of lathing, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed by Engineer-in-Charge. Note : Payment for providing grooves shall be made separately.
M&L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered or unplastered surfaces of wall by mechanical method i.e. electric grinder and applying two coat of distemper oil emulsion white/tinted with a wall care putty finished surface over one coat of primer by mechanical roller/ hand roller complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment of old decorated surfaces of wall by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by mechanical method i.e. Electric grinder and applying two coat of distemper oil emultion white/tinted with a wall care putty finished surface over one coat of primer using mechanical roller/hand roller complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment of old decorated surfaces of ceiling by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of distemper oil emulsion by mechanical roller white/tinted with a wall care putty finished surface over one coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered or unplastered surfaces of wall and applying two coat of cement base paint over one coat of primer complete all as specified and directed by Engineer-in-Charge.
Demolition of Brickwork or stone/boulder masonry,built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
M&L for old size brickwork with fly ash bricks straight or curved on plan exc 6 m mean radius wall built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
Taking up or down 15mm dia GI Tubing and connection including, cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
Taking up or down 20mm dia GI Tubing and connection including, cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
S&F 15mm bore GI tubing medium grade with all fittings fixed to walls or laid in floors complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 40 here-in-before but for except tubes complete all as specified and directed by Engineer-in-Charge.
S&F 20mm bore GI tubing med grade with all fittings fixed to walls or laid in floors complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 42 here-in-before but for except tubes complete all as specified and directed by Engineer-in-Charge.
S&F 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge
S&F in repair 15 mm fancy type chromium plated Angle valve/stop valve, screwed down high pressure,with crutch or butterfly handle scresed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge
S&F in repair 15mm bib taps, long body, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge
S&F in repair 15mm brass CP wall/basin/sink mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge
S&F in repair Vitreous china wash down water closet pan (pedestal pattern), white with fixing bolts, and flush pipe including 10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level ,white, with inlet ball valve, float and handle including brakets, PTMT health faucet and seat cover with one PVC connection 15x450mm complete all as specified and directed by Engineer-in-Charge
S&F for Vitreous china squatting pan, 'Orissa' pattern, size 580x440 mm white, with integral foot rests, including 10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level ,white, with inlet ball valve, float and handle including brakets & Trap, 01 Nos PVC connection 15x450mm, lime concrete bedding, etc complete all as specified and directed by Engineer-in-Charge
S&F for Vitreous china bowl urinal flat back, size of 465 x 355 x 265mm white (minimum), with grating and union for discharge pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws complete with flush pipe and half turn valve 15mm more complete all as specified and directed by Engineer-in-Charge
S&F for vitreous china wash basins, size 550x400mm white flat back including cutting for and pinning in ends of brackets or erecting stand including 32mm waste fittings, waste pipe with long screwed shanks & fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed by Engineer-in-Charge
S& F PVC connections 15 mm size, 450 mm long with PTMT nuts complete all as specified and directed by Engineer-in-Charge
S&F brass CP Toilet paper holder complete all as specified and directed by Engineer-in-Charge
S&F in repair Rotational moulded polythylene 1000 capacity water storage tank(Cylindrical vertical with closed top) hoisted and fixed in position including PVC float valve 20 mm bore, high pressure with polythene ball & float & dismantling of old water tank complete all as specified and directed by Engineer-in-Charge
S&F in repair Rotational moulded polythylene 500 capacity water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position including PVC float valve 20 mm bore, high pressure with polythene ball & float & dismantling of old water tank complete all as specified and directed by Engineer-in-Charge
S&F repair Gypsum board 12 mm thick in ceiling fixed with screws as per manufacturer instructions plain/ colour fixed with steel snap grid (power coated bottom side )with 'T' and 'L'(25 mmx30mmx1mm thick )section of size 600 mmx600mm placed in ceiling 'L' section fixed with wall with PVC rawal plugs and steel screws @ 600 mm centre to centre and suspended /provided5.0 mm dia galvanised bar @ 1.00 sqm hanging arrangement and levels incl adjustable clips, as specified in clause 10.38 of MES schedule part-I complete all as specified and directed by Engineer-in-Charge Note:- if any minor electrical fitting and fixtures distributed their in will be match and fixed as existing.
S&F for Hollow PVC wall lining interlocking type 7 mm thick/plain /coloured fitted into the wall with PVC rawal plugs and steel screws including fillet to joints as per manufacturer instruction complete all as specified and directed by Engineer-in-Charge Note:- if any minor electrical fitting and fixtures distributed their in will be match and fixed as existing.
M&L for roof treatment as specified below and as directed:- (a) cleaning, washing of surface and removing all existing bitumen coating completely with intense wire brushing or high speed water jet surface should be free from any loose paint, dust or grease.(b) All crack up to 3 mm at corner joints, channels and parapets should be treated with crack seal and bigger cracks, damaged portions and hollow areas must be repaired with polymer modified cement mortars. (c) Applying one coat of prime seal/Epoxy primer/ Shali Urethane BTD white diluted with potable water in the ratio of 1:1 and apply @ 0.40 kg/sqm(0.20 kg BTD +0.20 KG water) (d) Laying polyster reinforced fibre net/ 50 gsm Geotextile mesh , up to 300 mm on walls. (e) Applying three coat of Hydroshield PUD microfibre reinforced UV resistent polyurethane (solid content 68%)/Damp proof ultra UV stable fibre reinforced elastomeric liquid waterproofing membrane formulated with PU hybrid polymers(solid content 55%)/smartcare PU Magnum elastomeric waterproofing coating based on hydrophobic polyurethane (solid content 85% ) /single component elastomeric liquid membrane Shaliurethane BTD white/oloured (Elongation 400%+-50, solid content >80% & specific gravity @ 30 OC 1.5 +- 0.03) @ TOTAL 2.00 Kg per sqm in two coats for maintaining thickness of 1.5 mm, with paint brush/roller up to 300 mm on walls.(f) The complete treatment to be carried out by authorised applicator of waterproofing manufacturer . Make:- Dr fixit/Asian /STP
M&L for 40mm thick PCC 1:2:4 TYPE B0(12.5 mm graded aggregate) with WPC in roof complete all as specified and directed by Engineer-in-Charge Note:- WPC will be measured and paid separetely
Taking down carefully existing aluminium/copper point wiring on batten or in PVC conduit or in MS conduit with GI earth wire etc (for light, fan, socket or power ) complete and making good the disturbed surfaces of walls, Floors, ceilings etc to match with existing all as specified and directed.
M&L for point wiring complete concealed with PVC insulated and unsheathed, flame retardant ( FR ) 1100 volt grade conforming to IS 694 electric cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core in and including rigid PVC concealed conduit recess in wall panelling or in brick wall after necessary opening and making good to disturbed surface not less than 19 mm dia, clip, with suitable MS terminal boxes ( not less than 1.0 mm thick )and painted with one coat of red oxide primer all around and two coats of black bituminous paint including earth dolly with 3 mm thick plastic laminated sheet top cover of approved colours including 1.50 sqmm green solid copper conductor as continuous earth wire with all accessories including lugs required for one light / fan point controlled by one switch, complete all as specified and directed for the following :-
All as per Srl item No. 61 here-in-before but for 5 Amp socket outlet 3/5 Pin controlled by one switch on independent board complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 61 here-in-before but for 5 Amp socket outlet 3/5 Pin controlled by one switch on same board complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 61 here-in-before but for one bell push controlled by one switch complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring complete concealed with PVC insulated and unsheathed, low smoke 1100 volt grade conforming to IS 694 electric cable of 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant Low Smoke ( FRLS ) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 2.5 sqmm green solid copper conductor as continuous earth wire with lugs complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring complete concealed with PVC insulated and unsheathed, FRLS 1100 volt grade conforming to IS 694 electric cable of 4 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 4 sqmm green solid copper conductor as continuous earth wire with lugs complete all as specified and directed by Engineer-in-Charge.
S & F for Bell AC 230V single pole DING DONG type complete all as specified and directed by Engineer-in-Charge.
S&F for switch bell push button type 6 Amp single pole complete all as specified and directed. Cat Part No F-902 for switch and F-919 for Switch frame complete all as specified and directed by Engineer-in-Charge.
S&F for ceiling fan regulator stepped type electronic fan regulator flush type including connections complete all as specified and directed. Cat Part No. F-911 for regulator and F-920 for socket frame complete all as specified and directed by Engineer-in-Charge.
S&F for switch 6 amps 250 V AC one way with ISI mark including 6 amps switch frame. Cat Part No F 900 for switch and F-919 for Switch frame complete all as specified and directed by Engineer-in-Charge.
S&F for socket 5 pin shuttered 6A 250 V AC including 6 A Socket frame. Cat Part No F 904 for socket and F- 920 for Socket Frame complete all as specified and directed by Engineer-in-Charge.
S&F for Switch single pole mini with porcelain Base 16 A 250 V AC with ISI mark including switch frame.Cat Part No F 954 for Switch and F-919 for Switch Frame complete all as specified and directed by Engineer-in-Charge.
S&F for socket 5 pin shuttered 6A/16Amp 250 V AC including 16 A Socket frame. Cat Part No F 951 for socket and F- 920 for Socket Frame complete all as specified and directed by Engineer-in-Charge.
S&F for Ceiling rose three terminals polycarbonate isolated body complete all as specified and directed by Engineer-in-Charge.
S & F for LED light fitting 1 x 07W attractive wall / ceiling mounted type with metalic channel and LED lamp 07W, white reflactor suitable for mirror fittings lamp holders connector block etc complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for LED light fitting 1 x 20 watt including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 1700 lumens, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed by Engineer-in-Charge.
S&F for decorative wall light fitting with 1 x 3 W with 3W LED Lamp B-22 base complete all as specified and directed by Engineer-in-Charge.
S & F for bed side light fitting with LED bulb 5W B-22 base complete all as specified and directed by Engineer-in-Charge.
S & F for Lamp holder angular batten insulated body PVC/polycarbonate with LED bulb 5W complete all as specified and directed by Engineer-in-Charge.
S&F for LED Bulk head 10Watt with opral diffuser , etc complete with accessories pre wired and including connecting with flexible cord of suitable size complete all as specified and directed by Engineer-in-Charge.
S&F for 15 W LED surface mounted luminaire comprising of epoxy powder coated aluminium heat sink with system wattage of 6W and 72 Nos LEDs. The LED Make must be of CREE/NICHIA/OSRAM / EVERLIGHT with 120 degree view angle, >100 lumen/watt, lumen maintenance >70% at 50000 hrs, colour temperature of 5000-6000K, >70 color rendering and LM 80 test compliance. The driver must be integral APFC and constant currtent type having THD <15% and power factor >0.95 with short circuit protection, open circuit protection, reverse polarity protection, high voltage protection complete all as specified and directed by Engineer-in-Charge.
Taking down and Refixing ceiling fan 1200 mm sweep complete AC single phase 230 Volt 50 HZ connecting with flexible cable 3 core copper conductor of size 23/0.0076 of suitable length from ceiling rose to ceiling fan including spary painting complete match with existing and hanging of fan with new hook nut bolts complete all as specified and directed by Engineer-in-Charge.
S&F for Exhaust fan light duty AC single Phase 230 V / 240V 50 Hz of size 300 mm sweep, complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed by Engineer-in-Charge.
S & F for Storage water heater 25 ltrs cap vertical mounting AC 230 Volts including connecting cord and plug, safety valve, nuts and bolts, complete including grouting of nuts and bolts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for wall mounting fan 400mm sweep 230 Volt with sturdy blades close mesh guard with spokes and pull chain arrangement for speed control and provision for fitting up and down complete sound proof complete all as specified and directed by Engineer-in-Charge.
S&F for sheet metal enclosure with socket plug top , single pole and neutral enclosure with two pin earth plug and socket complete with one MCB of capacity 20-32 Amps complete all as specified and directed by Engineer-in-Charge.
S&F for Vertical type load line distribution board, acrylic double door, 4 way, AC ,3 Phase, 415 volts ,TPN bus bar 200 Amps rating and earth bus & din rail complete, with MCB SP40Amp C Curve-12Nos complete all as specified and directed by Engineer-in-Charge. Note : Rate for half concieling the DB in brick wall deemed to be included in the quated rate.
S&F for MCCB 4pole, 415 Volt 160Amps with breaking capacity 16 KA with spreader links complete all as specified and directed by Engineer-in-Charge.
S&F for factory made, acrylic door sheet steel distribution board MCB SP&N 8way, suitable IP-42 for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 duly half recess in wall and making good to disturbed surface complete all as specified and directed by Engineer-in-Charge.
S&F for MCB SP40 Amp 240 V , 50 Hz, complete all as specified and directed by Engineer-in-Charge.
S&F for MCB SP6 to 32 Amp 240 V , 50 Hz, complete all as specified and directed by Engineer-in-Charge.
M &L wiring for circuit /sub main wiring with under mentioned runs of single core PVC insulated but unsheathed FRLS cable of specified size with multi stranded copper conductors, 1100 volts grade, IS-694 marked, drawn-through in and including PVC conduit concealled/surface along walls roofs etc and fittings / accessories including the specified run and size earth continuity conductor of similar type cable complete all as specified and directed by Engineer-in-Charge. The under mentioned specified runs of single core cables and run of earth continuity conductors shall be measured as one run length For 4 runs of 10Sqmm main cable and 2X6 sqmm size earth continuity conductor.
M &L wiring for circuit /sub main wiring with under mentioned runs of single core PVC insulated but unsheathed FRLS cable of specified size with multi stranded copper conductors, 1100 volts grade, IS-694 marked, drawn-through in and including PVC conduit concealled/surface along walls roofs etc and fittings / accessories including the specified run and size earth continuity conductor of similar type cable complete all as specified and directed by Engineer-in-Charge. The under mentioned specified runs of single core cables and run of earth continuity conductors shall be measured as one run length For 2 runs of 6 Sqmm main cable and 1X6 Sqmm as a earth continuity conductor
M &L wiring for circuit /sub main wiring with under mentioned runs of single core PVC insulated but unsheathed FRLS cable of specified size with multi stranded copper conductors, 1100 volts grade, IS-694 marked, drawn-through in and including PVC conduit concealled/surface along walls roofs etc and fittings / accessories including the specified run and size earth continuity conductor of similar type cable complete all as specified and directed by Engineer-in-Charge. The under mentioned specified runs of single core cables and run of earth continuity conductors shall be measured as one run length For 2 runs of 4Sqmm main cable and one run of 4Sqmm as a earth continuity conductor
S & F for PVC flexible conduit 40 mm dia complete all as specified and directed by Engineer-in-Charge
S & F for PVC sleeves for connection of conductor to MCB DB any type any size complete all as specified and directed by Engineer-in-Charge
Supply & Laying LT under ground cable XLPE insulated armoured and PVC sheathed 3.5 core 50Sqmm cross sectional area heavy duty electric with aluminium conductor 1100Volts grade in trenches / passing through pipes including including cable connecting lugs, glands, jointing fixing materials after taking out exisisting unserviceable cables complete all as specified and directed by Engineer-in-Charge
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in any type of soil (soft/loose/hard/dense soil) for foundation and getting out and leveling of bottom surface to required level complete all as specified and directed by Engineer-in-Charge
Returning filling in, including spreading, levelling, watering and well ramming soils in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge
Removing the excavated meterials not exeeding 50 m and depositing where directed at level not exeeding 1.5 m above the starting level complete all as specified and directed by Engineer-in-Charge
M & L for sand cushioning with dry and clean fine river sand for underground cable 8cm before laying the cable and 15cm after laying and punned to 18cm after laying of cable complete all as specified and directed by Engineer-in-Charge
Supplying and laying well burnt clay bricks old size class 'B' laid dry and flat for protection over the cable with equal to the length of cable, complete all as specified and directed by Engineer-in-Charge.
M&L for GI pipe light grade 40 mm dia for cable protection on road crossings /plinth protection or fixed to the pole/ wall etc for cable protection complete all as specified and directed by Engineer-in-Charge
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 Mtr below ground level with top edge of earth plate at a depth not less than 1.5 Mtr below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts and washers of galvanized iron or steel and thimbles upto equipment and other end of the earth wire connected to earthing test point and protected by galvanized iron pipe light grade 20mm dia upto earthing test point / equipment fixed with 2 Nos. of mold steel clamps made out of 25mm x 3mm flat iron and preforated water pipe 20mm dia galvanized iron pipe heavy grade 2.25 Mtr long and top with socket and plug and bottom connected to earth plate by silt and two bolts / nuts / washers complete with funnel and wire mesh, PCC chamber in cement concrete (1:3:6) type C-1 and cast iron cover with frame all as shown on electrical plate No. 3 of MES Schedule Part - I of SSR-2009 complete all as specified and directed by Engineer-in-Charge. Note : (i) Outer edge of earth pit will be 1 Mtr away from the outer edge of PCC Chamber. (ii) Galvanized iron earth wire 4mm dia upto earthing test point / equipment is encluded in this item. (iii) Water pipe shall be provided in slainting position. (iv) 20mm dia galvanized iron pipe for watering shall be provided with a socket and plug and shall be 10cm above the ground level.
Supply, fixing and testing LED street/Security light fitting of 25 watt including LED lamps complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy including fixing on wall with 1.2 mtr long GI pipe 32 mm dia medium grade bracket at 120 degree angle with help of suitable GI clamps, nuts, bolts and washers etc complete all as directed. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP 65 protection as per IS - 10322-1982 with latest amendments and input voltage range 140 - 300 V, AC, frequency 50-60Hz,PF should be more than 0.9 with Total Harmonic Distoration THD(I) less than 15%,cool white colour and lamp statring time should not be more than 10 second. Fitting should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage with standing capacity upto 300 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from (-) 10 degree centrigrade 50 degree centrigrade and humidity level 10 % to 90 % RH. Covers should be polycarbonate/toughened glass to ensure IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM - 79 test report complete all as specified and directed by Engineer-in-Charge. -------------------------------------------------------------------------------------------------------------- Note : A sum of Rs. 38,722.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 32 & 33(R) (Schedule of Credit) of Tender document
M/s Balvinder Singh Engineer and Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .