Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC SULTANPUR SULTANPUR SARDARPUR DIST DHAR M P 454001 | SULTANPUR | DHAR | MADHYA PRADESH | 454001 | ₹2.3 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹2.7 CrRejected-Finance | ₹2.7 Cr | L2 | Rejected-Finance NOT L1 |
Tender Value
₹2.5 Cr
EMD Value
₹2.5 L
Closing Date
10 Feb 2026, 5:00 pmClosed
Chief General Manager
MPRRDA HO, 3rd Floor, Vikas Bhawan, Arera Hills, Bhopal
Construction / Upgradation of Road/ CD works including maintenance for Five year after construction-UPG.
2026_MPRRD_476300_3
NIT-1245-UPG-Brg
Open Tender
Civil Works - Bridges
548 days
Dhar-1
Please refer Tender document
7 documents required · 7 mandatory
₹17,700
₹2.5 L
24 Mar 2026
20 Jan 2026
12 Feb 2026
20 Jan 2026
10 Feb 2026
21 Jan 2026
Construction/Upgradation of Rural Road and CDs under Package No. MP11UBR05 (Offer Based on SOR issued by MPPWD Effective from 11-04-2025.) as per detailed BOQ attached in Annex-II A.
Please Enable Macros to View BoQ information
MPRRDA, PIU Dhar-1
Bill of Quantity
Details for the Percentage (%) Rate Tender
Based on SSR 11-04-2025
District :- Dhar PIU :- Dhar-1 Package No. :- MP11UBR05
Badnawar
Total Bridge Length
Amount of Bridge Cost
Amount of Maintenance Cost
Total Amount of PAC
Approach work
Embankment/ Sub Grade Construction with Material Obtained from Borrow Pits Construction of embankment with approved material having CBR>7 obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-1, 300-2 and as per relevant clauses of section-300.
Granular Sub-base with Close Graded Material (Table: - 400-1) Plant Mix Method (Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401)
Prime Coat Over WMM/WBM Providing and applying primer coat with catonic bitumen emulsion on prepared surface of granular Base including cleaning of road surface and spraying primer at the rate of 0.70 to 1.00 kg/sqm using mechanical means as per clause 502 of specifications.
MPRRDA/24 (14.10)
Retro- reflectorised Traffic signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2012 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT&H specification of in the clause IRC 6.8 of the IRC 67-2012 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 80 x80 x 3mm Square pipe of 3 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back support frame of 25x50x1.25mm tubular frame with the help of suitable sizes pop rivettes of 6mm or by the help of G I / Nickle Chome plated nut & bolts to be hammered after tightening. 10 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture brand like 3M/Avery Dennison/ Orafol make as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor. Note:- Manufacture name and date of manufacture is to be printed (Embossed) at the backside of the board.
Direction and Place Identification signs more than 0.9 sqm size board. Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2022 made of high intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC: 67:2022 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2022 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2022 and Table 800-3 of MoRT&H specification of in the clause 6.8 of the IRC 67-2022 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on 2 nos. of MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back-support frame of 25mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture brand like 3M/Avery Dennison/ Orafol Make as per clause 6.9 of IRC: 67:2022 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2022 for the product offered shall be submitted by the contractor. Note: - Manufacture name and date of manufacture is to be printed (Embossed) at the backside of the board.
Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beeds on Bituminous surface. Providing and applying (Cleaning of Bituminous surface) thermoplastic compound having composition of binder (Resin) minimum 18 %, titanium dioxide minimum 10 % and intermixed glass beed, minimum 30% of brand like Asian, Burger or equivalent make of 2.5 mm thick including drop down reflectorizing, glass beeds @ 250 gms per sqm area thickness of 2.5 mm is exclusive of surface applied glass beeds as per IRC:35.The finished surface to be level, uniform and free from streaks and holes, all complete as per clause 803 of specifications. Note: - The guarantee of Thermoplastic should be minimum 3 Years.
Providing and fixing in position Marble Plates of size 0.9 m. x 1.2 m.with inscribed details as per detailed drawings.
MPRRDA/24 (10.12 ( B))
MPRRDA/24 (10.12 ( C))
MPRRDA/24 (10.13)
Bridge work
Supplying, fitting and placing HYSD bars reinforcement in super- structure complete as per confirming to IS 1786:2000 drawing and technical specifications as per relevant clauses of section 1600 (i) FE 500
Providing and laying Cement concrete wearing coat 75 mm thick with M-30 grade concrete with cement , coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 19 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with static paver, spread, compacted and finished with power trowel in a continuous operation including provision of admixtures as approved, curing compound, finishing to lines and grades as per drawing but including cost of steel etc. including reinforcement, texuring with texuring brush complete as per drawing and Technical Specifications and as per relevant clauses of sections 1500, 1700 and Clause 2702 of specifications.
Drainage Spouts complete as per MoRT&H standard drawing and Technical specificationand as per clause 2705 of specifications.
Strip Seal Expansion Joint Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 80 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation. 1. The extrusion section shall be truly monolithic, and no welding shall be allowed in the section. 2. The minimum height of the extrusion shall be 80 mm, and the total cross-sectional area of the extrusions, including the seal- holding lip, shall be at least 1500 mm². 3. The minimum thickness of the seal-holding lip shall be 6 mm. However, the thickness of the extrusion throughout the section shall not be less than 10 mm. 4. The total cross-sectional area of the anchor loop or headed shear studs on each side of the joint shall not be less than 1600 mm² per meter length of the joint. The center-to-center spacing shall not exceed 250 mm for loop anchors and 150 mm for headed shear studs. The thickness of the anchor plate shall be at least 0.7 times the diameter of the anchor loop or 12 mm, whichever is greater. 5. The steel for edge beams shall conform to any of the following
Testing of span of bridge for deflection due to live load with platforms for loading arrangements apparatus for measurement including unloading etc. complete as per approved drawing.
Painting on concrete surface Providing and applying 2 coats of water-based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m.
Construction of RCC railing with precast rails and cast in situ vertical post of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post at expansion joints of superstructure for expansion, complete as per approved drawings and technical and as per relevant clauses of sections 1500, 1600, 1700 and clause 2703 of specifications (as per MoRT&H specification drawing SD/202 or SD/305)
PCC M15 Grade leveling course below approach slab complete as perdrawing and Technical specification and as per relevant clauses of section 1700.
Reinforced cement concrete non-structural approach slab (Grade of concrete M 30) as per MoRT&H standard drawing including reinforcement and formwork complete as per drawing and Technical specification and as per relevant clauses of section 1500, 1600, 1700 and clause 2704 of specifications.
Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom as per relevant clauses of section 300 & 2100 in
Mechanical Means
Providing Plain cement concrete M-15 nominal mix in foundation as per relevant clauses of sections 1500, 1700 and 2100.
Providing & Filling Annular Space Around Footing in Rock upto top of rock with Lean cement concrete M-15 nominal mix in foundation 1.5 m in soft rock and 0.60 m in hard rock with crushed stone aggregate 40 mm nominal size and as per relevant clauses of sections 1500, 1700 and 2100. Note: - Only footing size with 15cm off set all around to be considered for pavement.
Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications and as per relevant clauses of section 1600. FE 500
Taking, exploratory boring 100mm dia at the location of piersand abutments or for high embankments in approaches in all types of strata as per IRC-78-1983 and section 2400 of specifications.
Supplying, fitting and placing HYSD bar reinforcement in sub- structure complete as per drawing and technical specifications and as per relevant clause of section 1600. FE 500
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications.
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification and as per relevant clauses 305 of specifications and as per appendix 6 of IRC-78. A Granular material
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MoRT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided behind entire surface after abutment, return wall and wing wall to the full height compacted to a firm condition complete as per drawing and technical specification.
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRT&H specifications complete including all accessories as per drawing and Technical Specifications. 1)All bearings must fulfill the latest requirement of IRC-83-II- 2018. 2) Each bearing must of its permanent Unique Identification number & manufacture logo for future traceability. 3) Each batch used in manufacturing of bearings must have minimum 60% polymer & maximum 5% of Ash content. 4) All bearings are having under the tolerance limit of IRC-83-11- 2018. 5) No reclaimed or vulcanized wastes shall be used for the manufacturing of bearing. 6) EPDM or Similar candidate elastomer use shall not be permitted. 7) In case of any issue or special railway requirement, a sample made from same batch of minimum size (200 x 200 x 20) mm shall be tested for 2 million fatigue cycle with frequency of 2hz to 3hz.
Providing and laying 1.5 m deep in rock and 1.5 m above rock 25mm dia Tor steel dowel bar in foundation including drilling 65mm dia bore hole in rock necessary bending, hooking tying reinforcement in position and grouting etc. complete as per drawing and specifications.
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications
Providing and laying suitable designed Filter material underneath pitching in slopescomplete as per drawing and Technical specification
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood, steel, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead up to 1000 meters.
Geneeral Manager
MPRRDA,PIU Dhar-1
MPRRDA,PIU-01, DHAR
Name of Roads & Length Included in Package
Details for the Percentage (%) Rate Tender
District :- Dhar PIU :- Dhar-1 Package No. :- MP11UBR05
No of Roads in Bridge :- 01
Badnawar
Total Proposed Road Length (in Km)
Amount of Construction Cost
Amount of Maintenance Cost
Total Amount of PAC
Assitant Manager/Sub Engineer
MPRRDA, PIU-1 Dhar
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.83 MB
Tendernotice_2.pdf
PDF • 4.34 MB
BOQ_560290.xls
BOQ • 0.56 MB
Download all tender documents and submit your bid