| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹1.1 Cr | L1 | Accepted-AOC Being 1st lowest |
| 2 | L2₹1.1 Cr+₹1.2 L (1.04%)Rejected-Finance SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | ₹1.1 Cr+₹1.2 L (1.04%) | L2 | Rejected-Finance Being 2nd lowest |
| 3 | L3₹1.1 Cr+₹2.2 L (1.97%)Rejected-Finance | ₹1.1 Cr+₹2.2 L (1.97%) | L3 | Rejected-Finance Being 3rd lowest |
| 4 | L4₹1.2 Cr+₹6.1 L (5.50%)Rejected-Finance 15 BOH ROAD DEFENCE ENCLAVE AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | ₹1.2 Cr+₹6.1 L (5.50%) | L4 | Rejected-Finance Being 4th lowest |
| 5 | L5₹1.2 Cr+₹6.7 L (6.03%)Rejected-Finance HIMACHAL BUILDING SHOP NO 10 CD BARFYWALA ROAD JUHU LANE ANDHERI W MUMBAI 400058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | ₹1.2 Cr+₹6.7 L (6.03%) | L5 | Rejected-Finance Being 5th lowest |
| Sl No | Description | Qty | Unit | Mahadev Enterprises L4 | Advait Enterprises L6 | M.K Enterprises L1 | pk Enterprises L2 | VARDHAMAN CONSTRUCTION COMPANY L7 | Nexus Infratech L3 | BALAJI TRADERS L8 | M/s PIONEER CONTRACTORS L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Note :- These items are to be executed in galleries of jetty (Restricted Work Environment arise during High tide ). The Rate quoted shall be accordingly considered for deemed to be include scaffolding , mobilization equipment and other safety equipment as work will be carried out in sea area along the Jetty. Nothing will be paid extra on account of Working in difficult area. | - | - | - | - | - | - | - | - | - | - |
| 2.00 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed by Engr-in-Charge. | 60 | Qtl | 450 ₹27,000 | 384 ₹23,040 Lowest | 409 ₹24,540 | 390 ₹23,400 | 550 ₹33,000 | 440 ₹26,400 | 600 ₹36,000 | 710 ₹42,600 |
| 3.00 | Material and Labour for Framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and fencing angle similar work conforming to Fe-290 Gde E-165, complete all as specified and directed by Engr-in-Charge. | 1,050 | Kg | 150 ₹1,57,500 | 112 ₹1,17,600 Lowest | 129 ₹1,35,450 | 118 ₹1,23,900 | 138 ₹1,44,900 | 140 ₹1,47,000 | 166 ₹1,74,300 | 140 ₹1,47,000 |
| 4.00 | Supply and Fix MS plate Fe 410-W (Gde E-250 quality A) (Plane/Chequered) 5 mm and over as open drain covers with 02 Nos of 150mm handle in each plate etc complete all as specified and directed by Engr-in-Charge. | 3,280 | Kg | 96 ₹3,14,880 | 94.5 ₹3,09,960 Lowest | 129 ₹4,23,120 | 118 ₹3,87,040 | 110 ₹3,60,800 | 101 ₹3,31,280 | 111 ₹3,64,080 | 105 ₹3,44,400 |
| 5.00 | Supply and Fix Rolled section Fe 410-W (Gde E-250 quality A) as in main and cross beams, hip and jack rafters; purlins, vertical post, plates, pipes where connected to common rafter and running rails and fixing with angle cleats or other connecting plates also fixing wind tie bars etc, complete all as specified and directed by Engr-in-Charge. | 890 | Kg | 98 ₹87,220 Lowest | 108 ₹96,120 | 119 ₹1,05,910 | 116 ₹1,03,240 | 122 ₹1,08,580 | 118 ₹1,05,020 | 130 ₹1,15,700 | 105 ₹93,450 |
| 6.00 | Supply and Fix MS Flat iron wind ties and stays for gutter including securing with bolts and all necessary drilling, bolting or riveting, etc conforming to Fe 410 or Fe 310, complete all as specified and directed by Engr-in-Charge. | 150 | Kg | 114 ₹17,100 Lowest | 136 ₹20,400 | 129 ₹19,350 | 123 ₹18,450 | 134 ₹20,100 | 120 ₹18,000 | 128 ₹19,200 | 150 ₹22,500 |
| 7.00 | Material and Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement, complete all as specified and directed by Engr-in-Charge. | 650 | Kg | 554 ₹3,60,100 Lowest | 694 ₹4,51,100 | 749 ₹4,86,850 | 745 ₹4,84,250 | 707 ₹4,59,550 | 572 ₹3,71,800 | 680 ₹4,42,000 | 600 ₹3,90,000 |
| 8.00 | Material and labour for welding grinding, buffing, and polshing of existing stainless steel railing with approved chemical for buffing complete all as specified and directed by Engr-in-Charge. | 250 | RM | 95 ₹23,750 Lowest | 250 ₹62,500 | 269 ₹67,250 | 271 ₹67,750 | 261 ₹65,250 | 278 ₹69,500 | 150 ₹37,500 | 395 ₹98,750 |
| 9.00 | Supply and Fix in repair 0.5 mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall fixed with self tapping screws, including dismentling of old sheet complete all as specified and directed by Engr-in-Charge.
Note:- Work shall be carried out on roof at 20 meter height. Unit rate shall also include the same as quoted by the contractor (non accessible roof/ wall cladding). | 200 | Sqm | 888 ₹1,77,600 Lowest | 968 ₹1,93,600 | 939 ₹1,87,800 | 945 ₹1,89,000 | 1,050 ₹2,10,000 | 889 ₹1,77,800 | 1,088 ₹2,17,600 | 923 ₹1,84,600 |
| 10.00 | Supply and Fix pre-painted galvalume aluminium zinc coating Gl based Plain steel sheet 0.5mm thick of any colour having tensile strength of 550 MPa as in roof covering / cladding to wall, fixed with self tapping screws, including dismentling of old sheet complete all as specified and directed by Engr-in-Charge.
Note:- Work shall be carried out on roof at 20 meter height. Unit rate shall also include the same as quoted by the contractor (non accessible roof/ wall cladding). | 20 | Sqm | 788 ₹15,760 | 768 ₹15,360 Lowest | 809 ₹16,180 | 800 ₹16,000 | 820 ₹16,400 | 789 ₹15,780 | 800 ₹16,000 | 800 ₹16,000 |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
22 Jul 2025, 6:00 pmClosed
CWE Karanja
CWE Karanja, Naval Station Karanja, Uran, Raigad, Maharashtra
REPAIRS / REPLACEMENT TO STEPS, RAILINGS, FENDERS, PVC LADDERS, ROOF SHEETS AND REPAIR / REPLACEMENT OF STREET LIGHT, ELECTRIC POLES, DUCT COVERS, LT CABLE AND MISC ITEMS AT EXPLOSIVE JETTY AND PIM JETTY UNDER AGE B/R-II AT NAVAL STATION KARANJA
2025_MES_716330_1
84457-K/E8
Open Tender
Civil Works
Item Rate
180 days
Naval Station Karanja
Please refer Tender Documents
8 documents required · 8 mandatory
₹1,000
GE (NW) Karanja
₹1.9 L
24 Sept 2025
24 Jun 2025
24 Jul 2025
24 Jun 2025
22 Jul 2025
15 Jul 2025
Amount
Note :- These items are to be executed in galleries of jetty (Restricted Work Environment arise during High tide ). The Rate quoted shall be accordingly considered for deemed to be include scaffolding , mobilization equipment and other safety equipment as work will be carried out in sea area along the Jetty. Nothing will be paid extra on account of Working in difficult area.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and fencing angle similar work conforming to Fe-290 Gde E-165, complete all as specified and directed by Engr-in-Charge.
Supply and Fix MS plate Fe 410-W (Gde E-250 quality A) (Plane/Chequered) 5 mm and over as open drain covers with 02 Nos of 150mm handle in each plate etc complete all as specified and directed by Engr-in-Charge.
Supply and Fix Rolled section Fe 410-W (Gde E-250 quality A) as in main and cross beams, hip and jack rafters; purlins, vertical post, plates, pipes where connected to common rafter and running rails and fixing with angle cleats or other connecting plates also fixing wind tie bars etc, complete all as specified and directed by Engr-in-Charge.
Supply and Fix MS Flat iron wind ties and stays for gutter including securing with bolts and all necessary drilling, bolting or riveting, etc conforming to Fe 410 or Fe 310, complete all as specified and directed by Engr-in-Charge.
Material and Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement, complete all as specified and directed by Engr-in-Charge.
Material and labour for welding grinding, buffing, and polshing of existing stainless steel railing with approved chemical for buffing complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair 0.5 mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall fixed with self tapping screws, including dismentling of old sheet complete all as specified and directed by Engr-in-Charge. Note:- Work shall be carried out on roof at 20 meter height. Unit rate shall also include the same as quoted by the contractor (non accessible roof/ wall cladding).
Supply and Fix pre-painted galvalume aluminium zinc coating Gl based Plain steel sheet 0.5mm thick of any colour having tensile strength of 550 MPa as in roof covering / cladding to wall, fixed with self tapping screws, including dismentling of old sheet complete all as specified and directed by Engr-in-Charge. Note:- Work shall be carried out on roof at 20 meter height. Unit rate shall also include the same as quoted by the contractor (non accessible roof/ wall cladding).
Material and Labour for 18 to 20 mm thick granite (of any type) work (rough surface) in steps, jambs, pillars, window- cills, cooking platforms and like in 20 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite in any position etc including dismantling of old Stone slab/tiles complete all as specified and as directed by Engr-in-Charge.
Material and Labour for 18 to 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in 20 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite in any position etc including dismantling of old Stone slab/tiles all as specified and as directed by Engr-in-Charge.
Chipping , removing carefully concrete work by low impact hammer, breaker without damaging the structure and cleaning and disposal of debris outside the premises etc, complete all as specified and directed by Engr-in-Charge. Hard concrete should not be removed by force.
Material and Labour for Clean existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. complete and applying two coats of alkaline rust converting primer on the rebars, including cleaning the reinforcement, wire brushing to remove loose rust spalls, wash the rebars with clean water within 3 minutes and wipe it dry, complete all as specified and directed by Engr-in-Charge
Material and Labour for applying two coats of Epoxy based Zinc primer in a span of four hours over the treated rebars and allow to dry for six hours, complete all as specified and directed by Engr-in-Charge. The application shall be by brush.
Material and Labour for cleaning all loose laitance on the concrete substrate and applying one coat of epoxy bonding agent on exposed concrete surface to ensure bond between old concrete and new concrete by brush application on railing / drain, complete all as specified and directed by Engr-in-Charge.
Material and Labour for ready to mix polymer cement plaster with high quality polymer additives (Polymer plaster) with 4 MPa compressive strength of required thickness over the entire cleaned surfaces including all tools and tackles, etc in damaged areas in 40 to 50 mm thickness including levelling profiling etc, complete all as specified and directed by Engr-in-Charge.
Material and Labour for applying concrete protection coating on finished structural members exposed to atmosphere, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes, complete all as specified and directed by Engr-in-Charge. Works shall be carried out as under :- (i) Cleaning of holes. Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles. Insert 12mm dia Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for minimum 12 hours. (iii) Cutting of nozzles. Cut the nozzles by chiesel after completion of grouting without damaging structural elements. (iv) In case crack upto 2 mm wide, fix the injection nozzles directly over the cracks, at intervals of 6 to 9 inches, using a drilling machine. Fix PVC/MS nozzles in these holes with fast-setting epoxy putty and let it dry for 2 to 3 days. Also, seal the crack between the ports with epoxy putty. (v) In case where the crack is wider than 2 mm upto 4 to 5 mm, drill holes at the sides of the crack in a staggered fashion, at intervals of 6 inches and affix them with epoxy putty as mentioned above. (vi) Also, seal the face of the crack with a liberal application of the epoxy putty.
Material and Labour for Injecting of site mixed cement slurry grout, mixed in specified proportion containing cement, sand water with addition of plasticizers (approved make) & migratory corrosion inhibitors, water cement ratio shall be varied between 0.5 to 1.0 for each hole, shrinkage compensating cement slurry mixed to a lump free fresh creamy consistency, Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 3-5 Kg/sqcm etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Injecting low viscosity (3-5 cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, including Mixing of materials : Mixing of material components (part a&b) in the required quantities as per manufacturer's instruction by weigh batching. Grouting : Fill the grouting gun with concrete penetrating corrosion inhibitor. Maintain desired pressure in the gun by air compressor; maintain the pressure at exit (2 to 3kg/sqcm) by monitoring pressure gauge at exit. Grout the material through prefixed nozzles in the structural elements @ 100ml per nozzle. Repeat the process for all the nozzles, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Providing and applying jacketing around columns with Micro concrete (Molith-MC) M40 including all lifts, shuttering, drilling holes and fixing shear anchor as per specification, complete all as specified and directed by Engr-in-Charge. Note:- Reinforcement and Formwork shall be measured and paid separately under relevant item. (Rates are including jacketing and micro concrete)
Material and Labour for Providing reinforced cement concrete type B-1, 1:1:2 (12.5 mm graded aggregate) in railing/parapet /Drain wall /Concrete anchor for mooring system and other similar items for any size at any height including demolition complete all as specified and directed by Engr-in-Charge.
Material and Labour for Pre-Cast Factory made RCC 1:1.5:3 (20mm Graded crushed stone aggregate) as in cover slab of manholes, septic tanks, drainage, flooring, bedded, and jointed in cement mortar 1:6 and pointed in cement mortar 1:3 with edges of slab covered with MS angle sections or similar articles with plain faces and set in Cement Mortar 1:4, including formwork & reinforced with 8mm dia TMT steel 100mm c/c both way, size and shape and pattern as approved by Engr-in-Charge/Garrison Engineer including demolition of existing, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified and directed by Engr-in-Charge. Note:- Replacement of steel reinforcement with TMT bars of appropriate size where 30% of cross section is reduced including dismantling of rusted steel complete all as specified and directed.
Providing and fixing additional main steel bars or stirrups of 5 mm dia and over and including 10 mm dia in various structural elements like column, beams and foundations including drilling, bending, welding and fixing the bars with epoxy putty etc (Steel provided on the basis of 1% of volume of concrete), complete all as specified and directed by Engr-in-Charge.
Material and Labour for Formwork to sides of concrete foundations, footings, columns, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finished surface complete all as specified and directed by Engr-in-Charge.
Material and Labour for Formwork to sides of pillars, posts, struts, piers, columns and stanchions square or rectangular in plan to provide rough finished surface to concrete complete all as specified and directed by Engr-in-Charge.
Material and Labour for formwork to edges of rough finished surfaces of concrete flats, treads, breaks in floors, window cills, concerte railings, opening in concrete walls, floors and roof not exc 20 cm wide and side of RCC /PCC bands in walls, horizontal or sloping and similar work exc 10 cm but not exc 20 cm wide, complete all as specified and directed by Engr-in-Charge.
Removing of unserviceable fender, and connected assessories from jetty as per site condition, complete all and directed by the Engr-in- Charge.
Supply and fixing SQUARE D FENDER of 400mm x 400mm and inner " D" 200 mm x 200 mm and upto length 8000mm long (as per drawing), the fender is to be homogeneous black colour and as per site requirement and with all properties as per relevant IS code IS-13848 -1993 and fixed in front of Concrete surface on the sea face of jetty wall with 3 numbers M30 SS 316 bolts per meter of length 300 mm. The fender shall be fixed with a MS galvanized flat Iron of size 100mm x 12mm covering the full length both side of fender complete all as specified & directed by Engr-in-Charge. The property of rubber shall be as follows :- Deflection - 50%, Reaction force - 34.8 Ton/Meter, Energy absorption - 3 ton-M per meter with a tolerance of -+10%. Before ageing : Tensile strength shall not be less than 17 MPa, Elongation shall not be less than 360% as per ASTM D412, Hardness Max 70° + 5 degree, shore 'A' as per ASTM D2240. After ageing at 96 hours at 70 (degree) : The tensile strength shall not be less than 80%, Elongation shall not be less than 80% as per ASTM D573 HARDNESS + 8 degree shore A as per ASTM D573, Tear strength shall not be less than 70KN/M, Compression set at 70° C for 24 hours 25% maximum - as per ASTM D395, Abrasion Resistance Maximum 1.5CC as per IS3400 PART III and Ozone resistance - No cracks as per ASTM D 1171. Complete test reports shall be submitted to the accepting officer through GE for approvals. Necessary factory inspection from a rep of accepting officer shall be carried out during manufacturing process, shall be arranged by the contractor . Cost for testing and factory inspection arrangements shall be deemed to be included in the rate quoted by the contractor and complete all as specified and as directed by Engineer-in-charge. Make :- IRM offshore and Marine Engineers Pvt Ltd / Lion Rubber Industries Pvt Ltd / High Tech Elastomers Ltd / Brahans Polymer Pvt Ltd. Note :- (i) The item rate shall also include the cost of SS M30 SS 316 bolt, Nuts and chemical for fixing the bolt as recommended and supplied by the manufacturer of rubber fender. Necessary arrangement of scaffolding, grouting of bolts as required and applicable is deemed to be included in item however necessary bolts, plate, chain, flat bar, shackle except Hilti epoxy resin etc will be paid separately. Any other left over details shall be as per manufacturer's instructions. (ii) D- fender shall be as per typical drg attached.
Taking down cement plaster on brick / concrete surface built in cement mortar including raking out joints, hacking for key, scrubbing down with water including taking down of old steel wire fabric etc, complete all as specified and as directed by Engr-in-Charge.
Material and Labour for cleaning all loose laitance on the concrete substrate and applying one coat of epoxy bonding agent on exposed concrete surface to ensure bond between old concrete and new concrete by brush application on wall, complete all as specified and directed by Engr-in-Charge.
Supply and fixing welded steel wire fabric, cut to length, fixed to steel members / reinforcement steel, weight per sqm not exc 4 Kg, complete all as specified and directed by Engr-in-Charge.
Material and Labour for rendering minimum 20mm thick polymer modified mortar in cement mortar (1:3) with graded quartz sand with additive Monolith - PMM of Fosroc/Krishnaconchem or polymer mortar HB of Dr. Fixit or Shalifix RM SG 01 of STP Ltd. 15% by weight of cement in one coat with and including curing as per manufacturer's instruction, complete all as specified and directed by Engineer-in-Charge.
Material and Labour for taking down defective street light/flood light fittings of any size/type/capacity from any height of LT pole/wall/high mast of any location exceeding 7.0 metre height for repair work and refixing in same position after repair work including checking, inspecting, testing and commissioning complete all as directed by Engr-in-Charge. Notes :- (i) Electronic driver, surge protection device etc shall be measured and paid separately under relevant item of BoQ. (ii) Necessary tools like ladders and other T&P required etc shall be arranged by the contractor and cost of the same including minor spares like nuts, bolts, washers etc.
Supply, fixing, connecting and testing in replacement integral LED flood light fitting, 120 watts energy saving & environmental friendly long life versatile pressure die cast aluminium body with clear toughened glass, individual LEDs with secondary lens optics with IP-66 ingress protection, over voltage protection, short circuit protection, open circuit protection, surge protection, LED CCT is 5700 K as light source suitable making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5/2.5 Sqmm, complete all as specified and directed by Engr-in-Charge.
Supply, fixing, connecting and testing in replacement integral LED flood light fitting, 200 watts energy saving & environmental friendly long life versatile pressure die cast aluminium body with clear toughened glass , individual LEDs with secondary lens optics with IP66 ingress protection ,over voltage protection, short circuit protection ,open circuit protection ,external surge protection, LED CCT is 5700 K as light source suitable making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5/2.5 Sqmm complete all as specified and directed by Engr-in-Charge.
Supply, fixing, connecting and testing in replacement integral LED Street light fitting, 60 watts energy saving & environmental friendly long life versatile pressure die cast aluminium body with clear toughened glass with over voltage protection, short circuit protection ,open circuit protection ,surge protection, LED CCT is 5700 K and IP-66 as light source suitable making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5/2.5 Sqmm, complete all as specified and directed by Engr-in-Charge.
Supply, fixing, connecting and testing in replacement integral LED Street light fitting, 90 watts energy saving & environmental friendly long life versatile pressure die cast aluminium body with clear toughened glass , individual LEDs with secondary lens optics with IP66 ingress protection, over voltage protection, short circuit protection, open circuit protection, surge protection, LED CCT is 5700 K as light source suitable making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5/2.5 Sqmm, complete all as specified and directed by Engr-in-Charge.
Supply, fixing, connecting and testing in replacement integral LED Street light fitting, 120 watts energy saving & environmental friendly long life versatile pressure die cast aluminium body with clear toughened glass, individual LEDs with secondary lens optics with IP66 ingress protection , over voltage protection, short circuit protection ,open circuit protection ,external surge protection ,LED CCT is 5700 K as light source suitable making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5/2.5 Sqmm, complete all as specified and directed by Engr-in-Charge.
Material and Labour for preparation of old painted surfaces of steel tubular pole/strut, of any description and in any position of any height and scrapping of pole with emery paper and applying two coat of aluminium paint on all the metallic surfaces including protection pipe, clamps, GI pipe bracket of street/security light, and pasting reflector tape, self adhesive, water proof in 3 different colour as directed for around the pole with applying one coat of white wash painting on coping of pole and numbering of poles, complete all as specified and directed by Engr-in-Charge.
Supply and fixing 1.5 Sqmm FRLSH PVC insulated three core unsheathed industrial multistrand cable with flame retardant low smoke (FRLSH) properties with flexible bright annealed bare copper conductor for voltage grade upto 1100 V confirming to IS-694:2010, complete all as specified and directed by Engr-in-Charge.
Supply and fixing 2.5 Sqmm FRLSH PVC insulated three core unsheathed industrial multistrand cable with flame retardant low smoke (FRLSH) properties with flexible bright annealed bare copper conductor for voltage grade upto 1100 V confirming to IS-694:2010, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing, Laying, jointing, connecting & testing XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminium conductor in trenches / pipe ducts/drawn through DWC pipe of following sizes including taking out old unserviceable cable, complete all as specified and directed by Engr-in-Charge :-
(a) 4 core 16 Sqmm
(b) 3.5 core 50 Sqmm
Supply and fixing SS nut bolts, clamp, screw of different size and sample, complete all as specified and directed by Engr-in-Charge.
Dismantling old unserviceable high mast light control panel including foundation and all accessories and Supply, installation, testing of street light control panel three phase with ingress protection IP-65 made of 14 SWG CRCA sheet metal (850 mm x 5000 mm x 400 mm), self supporting, floor mounted, dust, vermin, weather proof for outdoor switching ON/OFF of luminaires (150/200 W - 10-20 Nos), . suitable rating power contactors, timer and one incoming and required Nos of outgoing MCBs of suitable ratings and main load circuit wiring of suitable size, complete all as specified and directed by Engr-in-Charge. Note :- The rate is deemed to be inclusive of necessary PCC foundation for panel mounting.
Material and Labour for taking down existing rusted pole with all accessories from existing position and set a side for further disposal and Supply and erection of steel tubular pole high mast pole of shape as per OEM or as directed of 12 metre length in 02 segment, 3.3 mm thickness, top and bottom having internal dia 150/360 mm, base plate size 550x18 mm, suitable for J drum winch, provision for mounting 06/09 Nos LED flood lights or as directed complete including 2 coats of aluminium paint over one coat of red oxide zinc chrome primer on external exposed surfaces and 2 coats of black bituminous paint on portion embedded in concrete in internal surfaces of pole, complete all as specified and directed by Engr-in-Charge.
Material and Labour for PCC 1:3:6 type C2 using (40 mm graded stone aggregate) as in foundation of pole, complete all as specified and directed by Engr-in-Charge.
Material and Labour for PCC type B-1, 1:2:4 using (20 mm graded stone aggregate) as in coping, including form work, complete all as specified and directed by Engr-in-Charge.
Material and Labour for SP of 6-32 A ,240 V with breaking capacity 10 KA Conforming to IS/IEC 60898-1:2015 , complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair Driver for 120-150 Watts LED lights as per existing make for the following capacity including taking down unserviceable drive, complete all as specified and directed by Engr-in-Charge.
Material and Labour for providing reinforced cement concrete (design mix) foundation M-30 grade including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete including demolition and dismantling of old RCC, complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable defective induction motor of any description and capacity from high mast including stainless steel wire rope 6 mm dia (7/19 construction), gear mechanism and all accessories and supply, install, testing and commissioning of induction motor of capacity 1/1.5 HP winch motor, 3 phase and including wire ropes, trailing cable, lugs, winch drum assembly etc, complete all as specified and directed by Engr-in-Charge.
Supply, install, testing of LED aviation LED light fitting of capacity 50 watts complete with die cast aluminium housing, red polycarbonate dome, integral driver, IP-65, operating of 100-270 Volts AC complete including dismantling old unserviceable light fitting, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Earthing complete with GI earth plate electrode 60cm x 60 cm x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level connected to and including GI strip 32 x 6 mm by means of bolts, nuts and check nuts and washers etc made of GI & connected to Earthing test point and earth dolly all as shown in elect plate No 3 of SSR Pt-I including all necessary earth work, excavation, PCC chamber, chamber cover with handle (PCC 1:2:4) including 40 mm dia protection pipe & 20 mm dia watering pipe and wire mesh funnel etc, complete all as specified and directed by Engr-in-Charge.
Supply, installing, testing and commissioning in replacement of factory made Outdoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50 Hz supply system including bus bar chamber in centre ( vertically) and cable alley either side, outer shell shall be made out of 3.0 mm thick CRCA sheet duly powder coated siemens grey shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitable to accommodate the following mentioned fittings and inner shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear including front openable single door with half nob type locking, including provision for taking out incoming and outgoing cables duly marked with riveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry etc including double compression type cable gland with bottom frame made out of angle iron 40mm x 40mm x 4 mm and 450mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accessories, complete all as specified and directed by Engr-in-Charge. :-
Supply and Fix in replacement LED Tiranga rope light 18 metre length, IP-65, input power 10W/metre, input voltage 220-240V AC, 50 Hz, PF 0.95, 120 LED/metre, having 6 metre length orange, white, green each, suitable for (-) 20 degree Celsius to (+)45 degree Celsius etc including driver for each cut piece, complete all as specified and directed by Engr-in-Charge.
Supply and erection of steel tubular swaged pole 410 SP 22, 8.5 metre long ,complete with cast iron base plate, finial Taper plug, bolts, nuts, and screws as specified type conforming to IS 2713 complete including 2 coats of aluminium paint over one coat of red oxide zinc chrome primer on external exposed surfaces and 2 coats of black bituminous paint on portion embedded in concrete in internal surfaces of pole including taking out old pole, complete all as specified and directed by Engr-in-Charge.
Material and Labour for in replacement of floor mounted manual revolving LED search light of capacity 400 watt, 220V, AC complete with all accessories prewired, complete all as specified and directed by Engr-in-Charge.
Material and Labour for taking street light terminal connector block for repair/replacement housed inside junction box/octagonal pole and replace with new as per existing including nuts, bolts etc, making cable connection fresh and replacement of aluminium cable lugs and providing screw to pole cover opening and replace the cover plate where required or directed cut to match with the shape and size as per existing and fixing complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exc 1.5 metre wide and not exc 1.5 metre depth and getting out in soft/loose soil, complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling watering and well ramming in layers not exc 25cm, complete all as specified and directed by Engr-in-Charge.
Removing excavated materials to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the Starting point, complete all as specified and directed by Engr-in-Charge.
Material and Labour for dry river sand as sand cushioning for protection of UG cable including punning of sand in layers, complete all as specified and directed by Engr-in-Charge.
Supply & laying un-reinforced precast concrete cable cover class LV type 1, flat size 250mm x 150mm x 40 mm, complete all as specified and directed by Engr-in-Charge.
Material and Labour for GI pipe light grade with all fittings complete laid in trenches all as specified for 100 mm bore of pipe, complete all as specified and directed by Engr-in-Charge.
Demolition and dismantling existing damaged/cracked PCC foundation of street light poles and including taking down and dismantling of pole and set a side for carrying out necessary repair work on damaged/cracked portion if required or complete where directed including removing loose foundation bolts if any and refixing in same position complete and erecting the pole in the same position with all necessary connections etc, complete all as specified and directed by Engr-in-Charge.
pk Enterprises (BID ID -3367204)
Nexus Infratech (BID ID -3367619)
Mahadev Enterprises (BID ID -3363076)
M/s PIONEER CONTRACTORS (BID ID -3365982)
Advait Enterprises (BID ID -3366955)
VARDHAMAN CONSTRUCTION COMPANY (BID ID -3367540)
BALAJI TRADERS (BID ID -3364367)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .