| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.6 LAccepted-AOC RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | L1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | L2₹36.9 L+₹1.3 L (3.58%)Rejected-Finance R G BARUAH ROAD NEAR SHIV MANDIR GUWAHATI AIRPORT GUWAHATI 781015 | KAMRUP METRO | ASSAM | 781015 | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹39.4 L+₹3.8 L (10.6%)Rejected-Finance KHASRA NO 716 POONIYON KI DHANI MEULASAR NAGAUR RAJ 341506 | NAGAUR | RAJASTHAN | 341506 | L3 | Rejected-Finance Other than lowest bid |
| Sl No | Description | Qty | Unit | SRI SAI CONSTRUCTION COMPANY L1 | M/S VISHNU ENTERPRISES L2 | M/S SHRI RAM CONSTRUCTIONS L3 |
|---|---|---|---|---|---|---|
| .01BOQ (PROVN OF SECURITY SHEDS AT ENTRY GATES AND ENHANCEMENT OF SECURITY INFRASTRUCTURE FOR STATION AND LODGER UNITS (VIEW CUTTER) AND DOG KENNELS AT AF STN SURATGARH) | ||||||
| 1.00 | Demolition of cement concrete in ground floors and paving not exceeding 15cm thickness (below or above ground level) un- reinforced and removing rubbish from the premises complete all as specified and direcetd. | 5 | Cum | 500 ₹2,500 | 168 ₹840 Lowest | 200 ₹1,000 |
| 2.00 | Demolition of brick masonry built in cement mortar including all quoins, arches etc. complete all as specified and directed. | 8 | Cum | 150 ₹1,200 Lowest | 165 ₹1,320 | 200 ₹1,600 |
| 3.00 | Material and labour for 15 mm thick rendering in cement mortar 1:4 mixed with approved water proofing compound on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement all as specified and directed.
Note: Water proofing compound shall be measured and paid separately. | 50 | Sqm | 270 ₹13,500 | 192 ₹9,600 Lowest | 300 ₹15,000 |
| 4.00 | M&L for prepration of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed. | 650 | Sqm | 40 ₹26,000 Lowest | 48 ₹31,200 | 60 ₹39,000 |
| 5.00 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade,with grey cement and pigment, including 25 mm thick layer of fine sand. complete all as specified and as directed. | 20 | Sqm | 650 ₹13,000 | 646 ₹12,920 Lowest | 650 ₹13,000 |
| 6.00 | All as per Sr item 05 above here in before but fixing only paver blocks (Paver blocks retrived from Ser item No 8 shall be reused after cleaning etc) | 23 | Sqm | 160 ₹3,680 | 86 ₹1,978 Lowest | 200 ₹4,600 |
| 7.00 | Demolition of stone slabs/paver block and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar, complete all as specified and directed. | 5 | X Sqm | 200 ₹1,000 | 35 ₹175 Lowest | 500 ₹2,500 |
| 8.00 | S&F PVC (SWR) pipes, 110mm dia, single socketed, in any length with rubber ring joints, laid in trenches or in floors or walls, complete all as specified & directed.Make: Finolex/Reliance/Supreme | 112 | RM | 300 ₹33,600 | 267 ₹29,904 Lowest | 300 ₹33,600 |
| 9.00 | S&F 110mm bore PVC (SWR) bends any radius, complete all as specified and directed. | 32 | Each | 60 ₹1,920 Lowest | 143 ₹4,576 | 300 ₹9,600 |
Tender Value
₹42.8 L
EMD Value
₹85,500
Closing Date
22 Jul 2025, 6:00 pmClosed
GE AF SURATGARH
GE AF SURATGARH
PROVN OF SECURITY SHEDS AT ENTRY GATES AND ENHANCEMENT OF SECURITY INFRASTRUCTURE FOR STATION AND LODGER UNITS AND DOG KENNELS AT AF STN SURATGARH
2025_MES_716518_1
8249/E8
Open Tender
Civil Works
Item Rate
210 days
GE AF SURATGARH
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE AF SURATGARH
₹85,500
Yes
11 Aug 2025
24 Jun 2025
24 Jul 2025
24 Jun 2025
22 Jul 2025
8 Jul 2025
Amount
BOQ (PROVN OF SECURITY SHEDS AT ENTRY GATES AND ENHANCEMENT OF SECURITY INFRASTRUCTURE FOR STATION AND LODGER UNITS (VIEW CUTTER) AND DOG KENNELS AT AF STN SURATGARH)
Demolition of cement concrete in ground floors and paving not exceeding 15cm thickness (below or above ground level) un- reinforced and removing rubbish from the premises complete all as specified and direcetd.
Demolition of brick masonry built in cement mortar including all quoins, arches etc. complete all as specified and directed.
Material and labour for 15 mm thick rendering in cement mortar 1:4 mixed with approved water proofing compound on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
M&L for prepration of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade,with grey cement and pigment, including 25 mm thick layer of fine sand. complete all as specified and as directed.
All as per Sr item 05 above here in before but fixing only paver blocks (Paver blocks retrived from Ser item No 8 shall be reused after cleaning etc)
Demolition of stone slabs/paver block and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar, complete all as specified and directed.
S&F PVC (SWR) pipes, 110mm dia, single socketed, in any length with rubber ring joints, laid in trenches or in floors or walls, complete all as specified & directed.Make: Finolex/Reliance/Supreme
S&F 110mm bore PVC (SWR) bends any radius, complete all as specified and directed.
Supply only integral water proofing compound complete all as specified
M&L for TMT mild steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for column, hooking end and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for TMT bars 6 mm to 8 mm dia and over cut to length, bent to shape reqd, including cranking and binding with and including MS wire annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L Cement Concrete 1:4:8 type D-2(40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required, complete all as specified and as directed.
M&L for RCC M-25 design mix using 20 mm graded stoine aggregate as in foundation, footings, fdn beam, plinth beam & mass concrete. Complete all as specified and directed.
M & L for formwork to sides of concrete foundation, footings, bases of column, plinth beams as for rough finished surfaces. Complete all as specified and directed.
S&F mild steel work as in wind ties for roof including securing bolts etc ,complete all as specified and as directed.
S&F for mild Steel work in hollow sections as in trusses, purlins ,rafters & roof members including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-4923:1997 and ammendments there to grade St.-240 including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-410 WA having Yst 240 Mpa. Complete all as specified and as directed. Note :- (i) The steel used shall be of primary producer only as given in Appx 'B'. (ii) Work shall be excuted upto 10 Meter of height (iii) All necessary precautions and safety measures shall be taken while execution of work.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes ; with riveted , bolted or welded attachment confirming to Fe 410 -W (Gde- E- 250) quality- A , complete all as specified and as directed.
S&F for Stack clamps made out of 50 mm x 5 mm flat iron and 16mm dia round iron stays for 100 mm bore pvc pipe, including bolts and nuts and securing ends of stays to wall or roof, complete all as specified and as directed.
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick (Any approved colour) having tensile streangth of 550 Mpa as in roof covering\ cladding to wall , fixed with self tapping screws ,complete all as specified and as directed
S&F for 1mm thick Mild steel, plain, black sheet in steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as require ,complete all as specified and as directed.
S&F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
S&F Mild steel screw bolts of 16-20 mm dia size (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 60 cm n exc 80 cm long , complete all as specified and as directed.
Excavating over areas n exc 1.5 m in depth and getting out in soft and loose soil,complete all as specified and as directed.
Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or manholes, pier holes, etc. not exc 10 sqm on plan and getting out in soft loose soil complete all as specified and directed.
Returning, filling in,including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft loose soil, complete all as specified and directed.
Removing excavated material not exc. 50m and depositing where directed at a level not exc. 1.5 m above the starting point, complete all as specified and directed.
M&L for surface point wiring with single core PVC insulated unsheathed 1100 volts grade FRLS cable of copper conductor multi stranded of size 1.5 sqmm (Nominal size) and including PVC casing caping of required size, floor etc, pressed MS Sunken boxes in wall of required size and colour for switches and sockets, 1.5 sqmm (Nominal size) PVC insulated (green insulation) copper conductor FRLS earth continuity cable drawn with wiring and connected to common earth dolly all as specified for one light point/Ceiling fan/ Exhaust Fan and wall mount fan controlled by one SP switch including making good distrubed surface, complete all as specified and directed. Note :- Cost for MS Sunken Boxes, Hylum sheets are cutting, chieseling and cutting the wall/Ceiling, making good to existing surfaces (Matching with existing colour) shall deemed to be included in the quoted rate.
All as per Srl item No 28 here-in-before but for one 5 pin socket out let, 6 Amps on same board with the cable 1.5 Sqmm size, complete all as specified and directed.
All as per Srl item No 28 here-in-before but for one 5 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size, complete all as specified and directed.
S & F switch piano flush button single pole one way 5 amp 240 volts, all as specified and as directed.
S & F Socket outlet, flush type 2 in 1, 3 pin, 5 amps, 240 volts all as specified and as directed.
S&F of ceiling rose, surface type, 65mm x 50mm, 3 terminal complete all as specified and as directed by Engr-in-Charge.
M&L for submain wiring with two single core 1.50 sq mm PVC insulated FRLS multistranded copper conductor cable drawing into and including PVC casing caping of reqd size and one single core 1.5 Sqmm multistranded copper conductor cable as continuous earth wire complete all as sepcified and as directed. Note- (a) The two runs of single core cable and casing caping with fitting/ acessories will be measured as one run.
S&F sheet metal enclosure for distribution board SPN (when MCBs to be used) 8 way double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail complete all as specified and as directed by Engr-in-Charge.
S&F of MCB SP, 6-32A,10KA, 'C' Curve complete all as specified and as directed .
S&F of MCB Double pole 6-32 Amp, 10KA, 'C' Curve complete all as specified and as directed.
PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and directed.
Material and labour for river washed and screened, dry sand for filling in trenches 8 cm below cable and 15 cm above cable and punned down gently to achieve 10 cm thickness of top layer for cushioning of cables etc, complete all as specified. Note: for payment purpose thickness after punning 18 cm will be measured and paid
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 10 sqmm 2 core with required aluminium cable lugs all as specified and directed.
Excavation of road cuttiug by manually including making good to disturb surface with PCC 1:2:4 type B2 on top not less than 150 mm thick including levelling and cambering according to existing road surface, refilling, watering, ramming etc complete all as specified and directed
Supply & fix 250 watt LED search light, motorised revolving aesthetically designed with excellent thermal management, pressure die-cast aluminium housing (heat sink) with toughened glass and high power LEDs and secondary lenses with IP66 protection system including epoxy powder coated with high efficiency long life 10 KV SPD inbuilt with electronic driver with APFC and connected accessories.
Supply and fix GI tubing light grade 40mm bore ISI marked on pole /wall with necessary clamps,nuts,bolts and washers/ under road crossing , for cable protection one all as specified and directed
M & L for three core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through PVC Conduit and OH line/ street light to pole box incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed.
S&F Eco round highbay light 80 watt, in PDC housing with efficacy of 110 lumens per watt and with 10 KV SPD robust design and efficient light distribution and excellent thermal management along with IP 66 protection reliable and suitable for ceiling (surface/suspended ) mount.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm all as specified and directed by Engir-in-Charge.
M&L for replacement of Earthing complete for bldg with galvanised mild steel plate electrode, 60cm x 60cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, PCC (concrete chamber of size 300mm x 300mm x 300mm inside dimension) shall be PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate with fair finish, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge, 8 mesh per liner inch, 80 mm thick PCC pit cover 320mm x 320mm of RCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) reinforced with XPM JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed.
Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary on serial page No 17 of tender documents.
M/S VISHNU ENTERPRISES (BID ID -3359367)
M/S SHRI RAM CONSTRUCTIONS (BID ID -3354789)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .