| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC 3082 SECTOR 20D CHANDIGARH 160 020 | CHANDIGARH | CHANDIGARH | 160020 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹24.9 L+₹50,667 (2.08%)Rejected-Finance 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹26.5 L+₹2.2 L (8.86%)Rejected-Finance V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹27.3 L+₹2.9 L (12.1%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹28.9 L+₹4.6 L (18.9%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
29 Jun 2020, 6:00 pmClosed
GE Chandigarh
GE Chandigarh
REPAIR,REPLACEMENT OF SUBMERSIBLE PUMP, SUPPLY CHEMICALS, CONNECTING ACCESSORIES AND MAINT OF CI,GI DISTRIBUTION PIPE LINES, SLUICE VALVE AND PERIODICAL MAINT OF WATER SUPPLY AND ELECTRIC SUPPLY INSTL INDOOR,OUTDOOR AT K AREA UNDER GE CHANDIGARH.
2020_MES_350991_1
GE/CHD-10/2020-21
Open Tender
Civil Works
Item Rate
270 days
Chandigarh
CLASS D CAT a ii
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹80,000
Yes
23 Jul 2020
9 Jun 2020
1 Jul 2020
9 Jun 2020
29 Jun 2020
17 Jun 2020
9 Jun 2020 - 13 Jun 2020
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5M in depth for taking out/for laying under ground pipes etc and getting out in Soft/loose soil complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers n-exc 25 cms in soft/loose soil complete all as specified and as directed.
Removing excavated soil to a distance n-exc 50mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point complete all as specified and as directed.
Taking up or down GI steel tubing 15mm dia/ bore with fittings complete and all as specified and as directed Note : Excavation, Removal and RFR will be measured and paid separately under respective item.
All as per Item No 4 above but 20mm dia/ bore.
All as per Item No 4 above but 25mm dia/ bore.
All as per Item No 4 above but 40mm dia/ bore.
All as per Item No 4 above but 50mm dia/ bore.
All as per Item No 4 above but 80mm dia/ bore.
All as per Item No 4 above but 100mm dia/ bore.
Supply, fixing, test and commssioning of GI Steel tubing medium grade 15mm dia/bore along with fittings in trenches/wall complete all as specified and directed. Make :- Jindal/Prakash/tata
All as per Item No 11 above but 20mm dia / bore.
All as per Item No 11 above but 25mm dia / bore.
All as per Item No 11 above but 40mm dia / bore.
All as per Item No 11 above but 50mm dia / bore.
All as per Item No 11 above but 80mm dia / bore.
All as per Item No 11 above but 100mm dia / bore.
Relaying the serviceable GI Pipe line 15mm dia / bore in the exsiting trenches/surface complete all as specified and as directed
All as per Item No 18 above but 20mm dia / bore.
All as per Item No 18 above but 25mm dia / bore.
All as per Item No 18 above but 40mm dia / bore.
All as per Item No 18 above but 50mm dia / bore.
All as per Item No 18 above but 80mm dia / bore.
All as per Item No 18 above but 100mm dia / bore. Note : Excavation and RFR will be measured and paid seprately under respective item.
M&L for Cutting/screwing & arresting the existing steel tubing 15mm dia / bore for inserting of Tee, Sluice valve/ gate valve, bends and elbow etc as specified and directed Note :- Each cut will be measured and paid separately under respective item
All as per Item No 25 above but 20mm dia / bore.
All as per Item No 25 above but 25mm dia / bore.
All as per Item No 25 above but 40mm dia / bore.
All as per Item No 25 above but 50mm dia / bore.
All as per Item No 25 above but 80mm dia / bore.
All as per Item No 25 above but 100mm dia / bore.
M&L for Screwing the existing steel tubing 15mm dia for inserting of Tee, Sluice valve/ gate valve, bends, socket and elbow etc of the following sizes. Note :- Each cut will be measured and paid separately under respective item
All as per Item No 32 above but 20mm dia / bore.
All as per Item No 32 above but 25mm dia / bore.
All as per Item No 32 above but 40mm dia / bore.
All as per Item No 32 above but 50mm dia / bore.
All as per Item No 32 above but 80mm dia / bore.
All as per Item No 32 above but 100mm dia / bore.
Disconnection and removing the U/S gate valve 15mm dia / bore and S&F Gun metal globe or gate valve 15mm dia /bore with iron wheel head, screwed both ends for GI Pipe complete all as specified and directed. Make :- Zoloto/Leader/Zenith/Neta/GEM
All as per Item No 39 above but 20mm dia / bore.
All as per Item No 39 above but 25mm dia / bore.
All as per Item No 39 above but 40mm dia / bore.
All as per Item No 39 above but 50mm dia / bore.
Disconnection and removing the Old U/S Pipe 80mm dia and Supply, fix, test and commssioning of DI pipes with spigot/ flanged and socket ends centrifugally cast. Class K-9, (ISI Marked) in any length, laid in trenches complete all as specified and directed. Make :- Electro steel/Kesoram/Tata/Lanco
All as per Item No 44 above but 100 mm dia / bore.
All as per Item No 44 above but 150 mm dia / bore.
Relaying the serviceable CI/DI Pipe line 80mm dia in the exsiting trenches/wall both Socket and Flanged ends complete all as specified and as directed.
All as per Item No 47 above but 100 mm dia / bore.
All as per Item No 47 above but 150 mm dia / bore.
M & L for Cutting CI/DI pipes 80mm dia and reducing to required length before laying (pipes supplied by M.D. for laying only) Note :- Each cut will be measured and paid separately under respective item
All as per Item No 50 above but 100 mm dia / bore.
All as per Item No 50 above but 150 mm dia / bore.
M&L for run lead joint in position, including removing old lead to store, etc of 80mm dia suitable for Spigot and socket pipe & fittings
All as per Item No 53 above but 100 mm dia / bore.
All as per Item No 53 above but 150/200 mm dia / bore.
M&L for Joint with rubber or fibre board gasket suitable for flanged pipes & fittings of 80mm dia
All as per Item No 56 above but 100 mm dia / bore.
All as per Item No 56 above but 150/200 mm dia / bore.
M&L for Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 150mm bore complete all as spfd and as directed
Disconnection and removing the U/S Sluice Valve and S&F Sluice Valve IS-14846, PN 1.6 stainless steel with hand wheel head, screwed both ends for GI Pipe 80 mm dia complete all as specified and directed of 80mm dia MAKE : Kirlosker/Upadhyaya/RMCO/Kartar
All as per Item No 60 above but 100 mm dia / bore.
All as per Item No 60 above but 150 mm dia / bore.
Disconnection and removing the U/S Air Release valve 80mm dia and S & F Air Release valve double chamber, IS-14845 of size 80mm dia with all fittings complete including taking down the old unsv one all as specified and as directed. MAKE : Kirlosker/Upadhyaya/RMCO/Kartar
Disconnection and removing the unserviceable/ broken Spindle Steel along with the check nuts & gate from the Sluice valve and M&L for New stainless steel with Brass Check nuts including polishing, machining, threading & necessary lathe work complete all as specified and as directed of 80mm dia.
All as per Item No 64 above but 100 mm dia / bore.
All as per Item No 64 above but 150 mm dia / bore.
Construction of valve pit chamber of size 120 x120 x120 cm with brick masonary in cement mortar 1:4, all internal surface to be plastered in cement mortar 1:4 and floor 100mm thick in cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggregate, including 6.00 mm thick MS sheet cover fixed with angle iron frame 40x40x6mm thick with locking arrangement and lifting handle including two coat of anti- corrosive synthetic enamel black paint over a coat of red oxide primer to steel surfaces including necessary earth work and PCC copping in cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate complete all as specified
Disconnection, removing from foundation stage, re-connections and transportation to defecting induction motor of 40HP from site to work shop and vice versa before & after repaired work complete all as specified and as directed by Engineer-in-charge. Note :- The cost of loading & un-loading for transportation shall be deemed to be included in the unit rate of this item. Nothing extra shall be entertained on this account
Dismantling to defective centrifugal submersible pump set suitable for 40 HP motor for repair, re-assembling to the same after repaired work including transportation of pump set from site to work shop & vice-versa, fixing to pump set on staging & motor, etc complete all as specified and as directed by Engineer-in-charge . Note : All the defecting spare parts except bronze bush shall be measured & paid separately under respective item 50 & 51 of this Sch ‘A’ as “supply only” .But fixing charges shall be deemed to be included in the unit rate of this item. Nothing extra shall be entertained on this account
Supply only ball bearing as per existing size. Make :- SSK/NBC/SKF
Supply only gun metal impeller as per existing size
Lathe work for turning of steel shaft & made as per required size
Disconnection & taking out to submersible pump with motor of any capacity 20 to 40 HP along with column pipe of any size upto 90 mtr (maximum) long and lowered the same after repaired to motor / pump along with existing / replaced column pipe, and re-connection for three phase AC Supply and tested at site to the satisfaction of Engineer-in Charge.
All as per above item No 73 here-in-before but 12.5 & 7.5 HP submersible pump set for sewage system along with column pipe of any size upto 12mtr. Note for item No 107 & 108 :- (i) Repair / replacement of pump /motor / column pipe / rubber gasket / Nut bolt and washers shall be measured and paid separately under respective items of this Schedule ‘A’. (ii) Transportation to defective motor / pump from well to work shop and vice-versa shall be deemed to be included in the unit rate of this item. Nothing extra shall be admissible on this account. (iii) The cost of T&P required for taking-out, lowering to submersible motor / pump / column pipe shall be deemed to be included in the unit rate of this item. Nothing extra shall be admissible on this account.
Dismantling to existing unserviceable submersible pump motor of 40 HP, 3 phase, 440 volts, 50 Hz, 2900 RPM and rewinding to stator with PVC insulated copper winding wire including sleeves, thimbles & minor spare parts like as bronze bushes, gland packing etc and re-assembling to the same motor after repair work . complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 75 he here-in-before but for submersible motor of 35/36 HP
All as per above item No 75 he here-in-before but for submersible motor of 25 HP
All as per above item No 75 here-in-before but for submersible motor of 20 HP.
All as per above item No 75 he here-in-before but for submersible motor of 12.5 HP.
All as per above item No 75 he here-in-before but for sewage submersible motor of 7.5 HP.
All as per above item No 75 here-in-before but for sewage submersible motor of 7.5 HP. Note for item Nos75 to 80 above,(i) Make for PVC insulated winding wire :- Finolex/ Havells/ Plaza/ Rallison. (ii) Taking out / lowering to submersible motor & pump shall be measured and paid under item No 73 & 74 of this schedule ‘A’. (iii) Defective spare parts exccept winding wire & bronze bushes etc shall be measured and paid separately under respective item of this schedule ‘A’ as “supply only” under item No 82 to 124 but fixing charges shall be deemed to be included in the unit rate this item.
Supply only bearing along-with thrust bearing plate for submersible Pump 40 HP complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 82 here-in-before but for 35/36HP.
All as per above item No 82 here-in-before but for 20HP.
All as per above item No 82 here-in-before but for 25HP.
All as per above item No 82 here-in-before but for sewage 12.5HP.
All as per above item No /82 here-in-before but for sewage 7.5 HP.
Supply only for motor bearing bush (set of five) for submersible Pump 40 HP complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 88 here-in-before but for 35/ 36HP.
All as per above item No 88 here-in-before but for 20HP.
All as per above item No 88 here-in-before but for 25HP.
All as per above item No 88 here-in-before but for Sewage submercible pump set 12.5HP.
All as per above item No 88 here-in-before but for sewage submersible 7.5HP.
Supply only for water seal & adopter (Set of two) suitable for submersible Pump 40 HP complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 94 here-in-before but for 35/ 36HP.
All as per above item No 94 here-in-before but for 20HP.
All as per above item No 94 here-in-before but for 25HP.
All as per above item No 94 here-in-before but for Sewage 12.5HP.
All as per above item No 94 here-in-before but for sewage submersible 7.5HP.(Mechanical Seal)
Supply only for stainless steel shaft suitable for submersible Pump 40 HP complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 100 here-in-before but for 35/36HP.
All as per above item No 100 here-in-before but for 25HP.
All as per above item No 100 here-in-before but for 20HP.
All as per above item No 100 here-in-before but for 12.5 HP.
All as per above item No 100 here-in-before but for 7.5 HP.
Supply only for Neck ring of impeller of gun metal for submersible Pump 40 HP complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 106 here-in-before but for 35/36HP.
All as per above item No 1066 here-in-before but for 25HP
All as per above item No 106 here-in-before but for 20HP.
All as per above item No 106 here-in-before but for 7.5/12.5HP.
Supply only for Bowl casing submersible Pump 40 HP complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 111 here-in-before but for 35/36HP.
All as per above item No 111 here-in-before but for 25HP.
All as per above item No 111 here-in-before but for 20HP.
All as per above item No 111 here-in-before but for 7.5/12.5HP.
Supply only for Shaft sleeve of stainless steel for submersible Pump 40 HP complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 116 here-in-before but for 35/36HP.
All as per above item No 116 here-in-before but for 25HP.
All as per above item No 116 here-in-before but for 20HP.
Supply only for Gun metal Impeller Model V-9 for submersible Pump 40 HP complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 120 here-in-before but for 35/36HP.
All as per above item No 120 here-in-before but for 25HP.
All as per above item No 120 here-in-before but for 20HP.
All as per above item No 120 here-in-before but for 7.5/12.5HP.
M&L for Replacement of unserviceable Rubber gasket for column pipe (80/100/125 bore) in lieu of provided with new Rubber gasket for column pipe (80/100/125bore) complete all as specified and as directed by Engineer-in-Charge.
S&F for Nut, Bolt & Washers machine made suitable for jointing of column pipe fixed as in repair complete all as specified and as directed by Engineer-in-Charge
Dsconnection and removing the u/s column pipe and S&F 80 mm bore mild steel water pipe heavy duty both end flanged as column pipe (each length of pipe 3metre long) as in repair complete all as specified and as directed by Engineer-in-Charge. Make :- Jindal/Parkash/Surya/Swastik
All as per item No 127 here-in-above but of 100mm dia Make:- Jindal/Parkash/Surya/Swastik
Disconnection and removing the U/S Heavy duty Socket connected between the lowering pipes of Submersible pumpsets and supply and fix GI Socket, Heavy duty 80mm dia and length 80mm ISI Marked complete.
All as per above item No 129 here-in-before but for 100mm
PVC insulated multi-stranded copper conductor 16 Sq mm (nominal area) 3 core submersible cable (copper) and connected to submersible pump set including submersible cable joints & LT panel board complete all as specified and directed. Make : FINOLEX/Havells/Polycab
All as per above item No 131 here-in-before but for 25Sqmm
Supply and filling of calcium based granular (Calcium hypochlorit granular) disinfectant for Chlorination of water having more stable than chlorine gas and contains no mercury, no heavy metal contamination, supported with test certificate, all as specified and including daily testing of water from different -different locations in presence of MES / Medical authority from SHO/MI Room and maintaining record of test result in a register and otaining signature of Medical Authority for all as specified. Brand Name Puri chlor. M/s BM Aqua Tech Pvt Ltd (Mark “ Baxer” brand)/ (Rayalseema/ M/s Grasim Industries Ltd Chemical Division / Declibac Tech Kolkata or any product approved by E-in-C’s Branch. Note :- (a) The supply of Grannular Chemical and testing of water samples for the period of 11 months. (b) Water samples collected and tested daily basis in presence of Medical / SHO Authority, Register in this regards shall be maintained and submitted by the tenderer to Engineer-in-Charge. (c) The tenderer fully responsible for chlorination of water every day. (c ) Supply of chemical to be given in standard package with test cert. (d) Expiry date of chemical should not be less than 12 months from the date of supply.
S&F as in repair incl testing and Commissioning of chemical dozing pump high pressure single head, adjustable dozing pump and high pressure range 0 to 100 PSI , Power 230 volts, 50 Hz, 40 Gallons per day self priming with vertical or Horizontal mounting type Make DECLIBAC model No 96NGQ51 or equivalent in Aquafit /RAMCO
S&F as in repair and Install Chemical dozing system consisting of not less than 100 Litre capacity PE/FRP tank with PE/FRP lid and level gauge alongwith agitator, shaft and blade in SS 316, (FRP / Epoxy coated) / Plastic - mounted on tank. Lid will have port hole for pouring Granular chemical and water when necessary. Lid will have provn of mounting dozing pump on the Lid / Wall motor - 90/120watts, 1440 RPM, 230 volts # 6 volts, 50 Hz with insulation class 'B' single phase, speed controller / Regulator to reduce speed upto 800 RPM Make :- M/s BM Aqua Tech Pvt Ltd (Mark “ Baxer” brand), M/s Grasim Industries Ltd Chemical Division (Mark “Aquafit brand“).Make varima / M/S Sombansi Enviro Engg Pvt Ltd (SEEPL) / any product approved by E-in-C’s Branch.
S&F as in repair agitator motor 120 Watt, copper wound, 900 RPM, Single phase 230 Volt with Shaft and impeller and all accessories suitable for mounting on FRP Tank lid or wall all as directed by Engr incharge. Make: Declibage/Aquafit/RAMCO
Supply & replacement of pump tube for chemical dozing system as per existing make and dimension and as directed complete all as specified and as directed
All as per item No 137 above but injection check valve 3/8" .
All as per item No 137 above but discharge tubing 3/8".
All as per item No137 above but Rotar Assy with bearings brackets and tolerances ring .
All as per item No 137 above but suction line strainer 3/8" .
All as per item No 137 above Roller Assy .
All as per item No 137 above but Gear motor complete 230 volt, 50 Hz .
All as per item No137 above but Gear motor Coil 250 volt 50 Hz .
Supply and installation in repair submersible pump set eletric driven 415 volts three phase specially designed for 150 mm dia bore well and 80 mm delivery with brass impellers having disscharge not less than 15 LPS at 145 mtr head complete with suitable type and capacity submerible 3 phase eletric motor. Make : Kirloskar/KSB/Crompton. Note : Cost of taking old unsv pump set from bore well along with column pipes and submersible cable carefully and lowering of new pump with coloumn pipe and submersible cable is deemed to be included in the quoted rates.
S&F FASDS suitable for 40 HP Submersible electric driven pump set, 3 Phase, AC 415 volt ,50 HZ with MS enclouser with Std proction etc complete all as specified and as directed by Engineer-in-Charge. Make : L&T/BCH
Disconnection and removing the U/S MCCB, 4 pole, 160 Amps and S&F MCCB, 4 pole, 160 Amps, 50 Hz, 415 volts, Range : 125 - 160A, rupturing capacity 25 KA including connecting the cables complete all as specified and as directed. Make : L&T/Seimens/Legrand
All as per item No. 147 above but Capacity 200Amp.
All as per item No. 147 above but Capacity 100Amp.
Disconnection and removing the U/S Automatic star/delta starter and S&F Automatic star/delta starter in SS enclosure with relay max range 28 to 42 Amps, 415V/440V and 3 Nos of Power Contactors of capacity 42 Amps, Prewired with ON/OFF Buttons complete including connecting the cable all as specified and as directed. Make : L&T/Seimens/GE/CG
Disconnection and removing the U/S Automatic star/delta starter and S & F Automatic star/delta starter in SS enclosure with relay max range 20 to 32 Amps, 415V/440V and 3 Nos of Power Contactors of capacity 40 Amps, Prewired with ON/OFF Buttons complete including connecting the cable all as specified and as directed. Make : L&T/Seimens/GE/CG
Disconnection and removing the U/S DOL starter and S&F DOL starter Type - MK1, 15A, 3 Phase, 50 Cycles, Relay Range upto 9-14 Amp, 415V/440V including connecting the cable complete all as specified and as directed. Make : L&T/Seimens/GE/CG
Disconnection and removing the U/S Electronic Timer and S & F Electronic Timer Series, Micon 225, Star Delta, Supply Voltage : 24 - 240 VAC/DC, 50 HZ, Timing : 0.3S - 120S including connecting the cable complete all as specified and as directed. Make :- L&T/Seimens/GE/CG
Disconnection and removing the U/S Thermal Overload Relay and S & F Thermal Overload Relay with Start & Off/Reset with Relay Range : 20 - 40A, 415V, 50 Hz including connecting the cable complete all as specified and as directed. Make :- L&T/Seimens/GE/CG
Disconnection and removing the U/S Contactor and S&F Power Contactor 1-40A, 220Volt AC, 50 Hz including connecting the cable complete all as specified and as directed. Make :- L&T/Seimens/GE/CG
Disconnection and removing the U/S 3P Contactor and S&F 3P Contactor MNX 32A, Coil Voltage 415V, 50 Hz including connecting the cable complete all as specified and as directed. Make :- L&T/Seimens/GE/CG
Disconnection and removing the U/S 3P Contactor and S & F 3P Contactor MNX 18A, Coil Voltage 415V, 50 Hz including connecting the cable complete all as specified and as directed. Make :- L&T/Seimens/GE/CG
Supply and installation in repair submersible Sewage pump set 7.5HP, 3PH, 50HZ, set eletric driven 415 volts three phase 6400RPM, Disharge 1200LPM, 10Mtr head. Make : Kirloskar/KSB/Crompton
Disconnection and removing the U/S MCCB and S&F MCCB, 3 pole, 125 Amps, 50 Hz, 415 volts, Range : 100 - 125A, rupturing capacity 25 KA including connecting the cables complete all as specified and as directed. Make : L&T/Seimens/Legrand
All as per item No. 159 above but Capacity 63Amp.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5Core 35 Sqmm MAKE - Havells/Polycab/Anchor
All as per item No 161 above but size 3.5core, 50 Sqmm.
M & L for sand filling using approved clean dry sand for cushioning of under ground cables incl spreading levelling and well ramming in layers not exc 25 cm.
Supply and laying of class B bricks for under ground cable protection as directed by Engineer- in - charge
M&L for trenches less cutting of road and culvert at the span of upto 4 mtr for crossing of UG Cable and GI Pipe os size up to 50mm dia
Cutting the existing road of 0.30m width and 0.60m depth for laying DI/GI GI pipe with all fittings such as bends, sockets, reducers union etc, complete incl excavation in any type of soil, rfr , removal and PCC 1:2:4 of 15 cm below the GL for making the the road cut portion good all as directed and spfd
Disconnection and removing the unserviceable/ corroded LT Panel board complete and M&L for LT Panel board cubicle type indoor floor mounted fabricated out of 3mm thick CRCA sheet and MS angle vermin proof, painted with two coats of synthetic enamel paint over one coat of red oxide both internally and externally 3 Phase 4 wire Aluminium bus bars of capacity 3X200 Amps for Phase and 1X200 Amps for neutral and fixed on insulators with digital volt meter - 01 No and digital ammeters for all the outgoings, indication lamps prewired complete comprising of the following :- Make of the Panel board confirming to CPRI specifications only.(a) MCCB 200 Amps FP 50 KA 415 Volts with adjustable thermal and magnetic setting - 01 Nos as Incomer(b) MCCB 160 Amps FP 25 KA 415 Volts - 01 Nos as outgoing(c ) MCCB 100 Amps FP 25 KA 415 Volts - 01 Nos as outgoing(d) MCCB 63 Amps 3P 25 KA 415 Volts - 02 Nos as outgoing
S&F in Repair 15mm Bib taps, Cast copper alloy Chromimum plated with screwed for iron pipe for beass ferrule and fixed complete all as specified and as directed.
S&F in Repair 20mm PVC Water tap specified and as directed.
Supply and replacement of glen dori as per side required for sluice valve fittings of the required sizes.
Supply and installation in repair booster pump set eletric driven 415 volts single phase 1/2HP Pressure booster pump are coupled to high efficient induction motor clockwise motor shaft for high quality alloy steel. The motor are totally enclosed fan cooled (TEFC), Capacitor start & run type with thermal overload protector.
Supply and installation in repair booster pump set eletric driven 415 volts single phase 1HP Pressure booster pump are coupled to high efficient induction motor clockwise motor shaft for high quality alloy steel. The motor are totally enclosed fan cooled (TEFC), Capacitor start & run type with thermal overload protector.
Construction of valve pit chamber of size 90X90X90 cm with brick masonary in cement mortar 1:4, all internal surface to be plastered in cement mortar 1:4 and floor 100mm thick in cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggregate, including 6.00 mm thick MS sheet cover fixed with angle iron frame 40x40x6mm thick with locking arrangement and lifting handle including two coat of anti- corrosive synthetic enamel black paint over a coat of red oxide primer to steel surfaces including necessary earth work and PCC copping in cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate complete all as specified
Supply and installation in repair single phase preventer for three phase panel set eletric driven 415 volts three phase starter complete all as specified and as directed. Make :- L&T/Seimens/GE/CG
Cleaning and maint of water supply installations and water tank including cutting/cleaning of grass/ bushes in surrounding of installation of clear water installation complete all as directed by Enginer-in-Charge
M&L for Cleaning of overhead water storage tank of capacity 1,00,000 gallons (450000Ltr Cap) by scraping internal and external surface of tank with brush and removing all scale / dirt / deposited silt including washed to internal surface of tank with solution of bleaching powder and applying one coat of cement base paint to internal and external surfaces of wall, top and bottom of tank , pillars / beams/ pipes etc after preperation of surface of OHT and providing one coat of synthetic enamelled paint with colour code on inlet / outlet/ washout/over flow pipes surfaces as per existing with writting the cleaning date with white colour on black base all as specified and as directed . Note : - Removing/Cleaning of Honey Bee hives shall be the responsibility of the contractor. No delay, No additional charges shall be considered on this account rates quoted against the item shall include the said element. b) Contractor is responsible for making all safety arrangments, scaffolding/jhulla for carrying out the above job with due care at a height of approx 22 Mtr
All as per item No138 above but capacity 75000 Gallons/337500 Ltrs capacity
All as per item No138 above but capacity 50000 Gallons/225000 Ltrs capacity
All as per above item No 176 here-in-before but cleaning of semi under ground water storage tank of 25,000 gallons. Note for item No 176 to 178 :- (i) The cost of required T&P, machine, motor, scaffolding shuttering shall be arranged by the contractor at own cost.
M & L Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,complete all as specified and directed.
M&L Cement concrete 1:5:10 type E-2 (40 mm graded crushed stone aggregate ) as in foundation filling complete all as specified and directed.
Steel work in tubular trusses including special shaped washer etc.complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified.
S&F Plates (plain or chequered) channels, square cut or notched(ordinary and counter sunk)forming holes, without any attachment complete.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
M&L for 100 mm thick PCC 1:3:6 type B-2 using 40 mm graded stone aggregate as in floor complete all as specified and directed.
Preparation of new steel Surfaces of any description,and applying two coat of synthetic enamel Paint to over 10cm in width or girth, not otherwise described, over a coat of red oxide primer complete all as specified and directed.
Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out soft/loose soil.
M&L for Hardcore in floor/plinth of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete
M&L for 75 mm thick Cement concrete type D- 2,1:4:8 (40mm graded crushed stone aggregate) as in sub base/Path complete all as specified and directed.
M & L for 60mm thick pre-cast cement concrete (Design mix M-40) grade pre-polished rubberized moulded vibratory compacted inter locking coloured paver block of any shape (confirming to ISI-15658-2006) laid over and including 50 mm thick ( compacted thickness ) sand cushioning and joint filled with sand complete all as specified and as directed.
M&L DI pipe 200 mm (certifugally cast) class 'K-9' (ISI Mark) in any length with spigot and socket ends complete including rubber ring joint (Tyton joint) as per IS- 1536-2001 jointed and laid in trenches or in any position, complete including taking down any type and size of pipe all as specified . Note :- Cost of rubber ring (tyton) joint is deemed to be included in the quoted rates .Make: Electro Steel/Lanco/Kesoram/Tata
Disconnection and removing the U/S Sluice Valve and S&F Sluice Valve IS-14846, PN 1.6 stainless steel with hand wheel head, screwed both ends for GI Pipe 200 mm dia complete all as specified and directed of the following sizes. MAKE : Kirlosker/Upadhyaya/RMCO/Kartar
Disconnection and removing the U/S CI Non Return valve and S&F Non return valve cast iron 100MM dia, PN-1.6 class with flanged ends at both sides complete fitted with GI pipe incl connected accessories and joining materials including taking down the old u/s one complete all as specified and as directed of the following sizes:- MAKE: Kirlosker/Upadhyaya/RMCO/Kartar
Disconnection and removing the U/S column pipe and S&F 150 mm colum pipe mild steel water pipe Heavy duty both end flangd as column pipe (each length of column pipe 3mtr) long as in repair complete all as directed by Engineer-in-charge.
Disconnection and removing the U/S thermal overload relay and S&F thermal overload relay with start & off/Reset with relay range 30 to 75 Amp .
Supply and fixing in repair electronic over current relay (BCOR-FEZ), start (Off) reset and detachable screen (EOCR 3EZ MODE: 110AC), Relay complete all as pecified and as directed. Make : BCH Electric limited or equivalent as approved by GE.
M/s badrinath Traders
Electromech Engineers
GS Engineers
M/S RAGBIR ENGINEERING SERVICES
M/s Super Trading Corporation
SKYLARK INDUSTRIES
His Construction Company
M/S BALWINDER SINGH
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .