Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹33.8 L+₹5.3 L (18.5%)Rejected-AOC | L2 | Rejected-AOC MORE THAN LOWEST | |
| 3 | L3₹34.1 L+₹5.6 L (19.6%)Rejected-AOC 1ST FLOOR GURJEET MARKET DHANGU ROAD | L3 | Rejected-AOC MORE THAN LOWEST | |
| 4 | L4₹36.4 L+₹7.9 L (27.8%)Rejected-AOC | L4 | Rejected-AOC MORE THAN LOWEST |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
28 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (N) Mamun
GE (N) Mamun C/O 56 APO
REPAIR/ MAINTENANCE AND REPLACEMET OF SECUIRTY LIGHTS AND CONNECTED WORKS UNDER D-IA ZONE, D-IB ZONE, D-III ZONE, D-IV ZONE AND MAP BHASKAR AREA OF GE (N) MAMUN.
2020_MES_399167_1
GE(N)/M- /2020-21 NIT-50/20-21
Open Tender
Civil Works
Item Rate
180 days
GE (N) Mamun
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (N) Mamun
₹70,000
Yes
18 Feb 2021
28 Nov 2020
30 Dec 2020
28 Nov 2020
28 Dec 2020
14 Dec 2020
60 days
Amount
Dismantling old unserviceable steel poles/Strut any size and shifting n.exceeding 50 meters for setting aside for re-use or for disposal action all as specified and directed.
Dismantling old unserviceable concrete pole/Strut any size and shifting n.exceeding 50 meters for setting aside for re-use or for disposal action all as specified and directed.
Material and labour for prestressed cement concrete pole 9 mtr long, 102 mm x 172 mm at top and 102 mm x 289 mm at bottom class-10 complete, erected truly in vertical position and painting the poles with alternate layer of 30 cm, black and yellow paint with synthetic enamel paint upto 1.5 mtr above from the coping complete all as specified and directed.
Material and labour for erection of steel tubular swaged street light single arm pole 9 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 31, including painting the poles with alternate layer of 30 cm, black and yellow paint with synthetic enamel paint upto 1.5 mtr above from the coping complete all as specified and directed.
Material and labour for erection of steel tubular swaged, dual arm for street light,11 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 55, including painting the poles with alternate layer of 30 cm, black and yellow paint with synthetic enamel paint upto 1.5 mtr above from the coping complete all as specified and directed.
Dismantling aluminium conductor of service feeder or distributor span of LT/HT line poles after unbinding from insulators for replacement/re-stringing of damaged conductors all as specified and as directed.
Restringing and restretching aluminium conductor of service feeder or distributor span of LT/HT line poles reterived under item Sr No.06 above including necessary binding with insulators using alunimium binding wire, connections of incoming and out going cables complete all as specified and as directed.
M&L for ACSR aluminium conductor of service feeder or distributor span of LT/HT line poless including binding with insulators using aluminium binding wire, jointing jumpers etc including connections of incoming and out going cables complete all as specified and as directed.
Dismantling carefully earth wire of service feeder or distributor span of LT/HT line poless after unbinding for replacement/re-stringing all as specified and as directed.
Restringing and restretching earth wire retrieved from item No 9 here in above of service feeder or distributor span of LT/HT line including necessary binding with insulators using alunimium binding wire, connections of incoming and out going cables complete all as specified and as directed.
M&L for Galvanised steel earth wire of service feeder or distributor span of street light poles including binding with insulators using GI binding wire, jointing jumpers etc including connections of incoming and out going cables complete all as specified and as directed.
Dismantling cross-arms of M.S. channel or angle sections etc of street light poles complete and setting aside for re-use complete all as specified and as directed.
Fixing only the cross arms items retrieved from item No 12 here in above with supports/ angle iron frame etc incl nut, bolt, washer, welding, bending, hot or cold drilling holes for insulators bolts in any size or shape complete all as specified and as directed.
Material and labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
Dismantling and taking old/UNSV stay assembly including Stay wire and insulator complete all as specified and directed.
M&L for stay assembly complete with MS stay plate of size 300x300x6mm thick, stay rod 20 mm dia, stay bow, nuts, bolts and check nuts of GI all as shown in EP No 01 of SSR Part-I, 2009 ( Excavation, PCC, saty wire and loop type insulators will be measured separately) complete all as specified and as directed.
M&L in replacmement galvanized stay strand of 7/4mm size complete all as specified and directed.
M&L in replacmement loop type insulator large size with overall dimensions (90 x140) mm with clearance of hole 25.5 mm vitreous white brown or green complete all as specified and as directed.
Dismantling insulators of any type, any size complete all as specified and as directed.
Fixing only shackle type insulators retrieved from iterm No 19 all as specified and as directed.
Fixing only pin type insulators retrieved from iterm No 19 all as specified and as directed.
M&L in replacmement shackle type insulators of 100 mm high, 115 mm dia porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts complete all as specified and as directed. Make : BHEL/ Jaipuria/ Rashtriya.
M&L in replacmement Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 1100 volts grade complete all as specified and as directed.
M&L in replacmement Disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green single disc assembly for tension with tension clamps for conductors, working pressure 1100 volts complete all as specified and as directed.
Taking out from trenches or wall/ pole or pipe cable LT 1100 volts grade heavy duty , aluminium conductor of any size,type and core upto 35 Sqmm, any core , for rectification of faults or replacement. Seggregating serviceable cable and unserviceable length by meggering or any other suitable and recommended method. Removing unserviceable from site and keeping aside serviceable for reuse at same location or any other location complete all as rquired at site or directed. (Earth shall be measured and paid separately under respective item).
All as per Srl Item No 25 above but of size 50 Sqmm to 95 Sqmm
Laying only serviceable cables upto 35 sq mm retrieved from item No 25
Laying only serviceable cables of 50- 95 sqmm retrieved from item No 26
Supply,laying testing and commissioning in replacement cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 95 Sqmm 3.5 core with Aluminium termination lugs complete all as specified and directed.
All as per Srl item No 29 above but Size 70 sqmm 3.5 core .
All as per Srl item No 29 above but Size 50 sqmm 3.5 core .
All as per Srl item No 29 above but Size 35 sqmm 4.0 core .
All as per Srl item No 29 above but Size 25 sqmm 4.0 core .
All as per Srl item No 29 above butSize 16 sqmm 4.0 core .
All as per Srl item No 29 above but Size 10 sqmm 2.0 core .
M&L for Cable straight through jointing kit, heat shrinkable, 1100 volts grade complete with jointing material and accessories suitable for 2/3.5 core XLPE armoured aluminium conductor cable of size 10-16 sqmm size.
All as per Srl item No 36 above but size of 25-50 sqmm, 3.5 core.
All as per Srl item No 36 above but size of 70-150 sq mm, 3.5 core .
All as per Srl item No 36 above but size of 185-240 sq mm, 3.5 core .
Supplying and fixing in replacement 1100 volts grade heavy duty cable ,6 sq mm, PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular all as specified and directed.
All as per Srl item No 40 above but Size 10 sqmm 2.0 core.
All as per Srl item No 40 above but Size 16 sqmm 2.0 core.
Supply and fixing in replacement of GI tubing, light grade 40 mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately )
All as per Srl item No 43 above but 80 mm bore.
All as per Srl item No 43 above but 100 mm bore .
S&F in replacement MCCB 3 pole 415 volts , fixed type 25 Amps to 100 Amps with braking capacity 16 KA, thermal release adjustable from 80 to 100% & fixed magnetic release with Ics = 100% Icu, including spreadres after taking out old U/S one all as specified and directed.
All as per Srl item No 46 above but 160 amps.
S&F in replacement MCCB 3 pole 415 volts fixed type 200 Amps with braking capacity 25 KA, thermal release adjustable from 80 to 100% & magnetic release adjustable from 5 to 10 In with Ics = 100% Icu including spreadres after taking out old U/S one all as specified and directed.
All as per Srl item No 48 above but 250 amps.
S&F in replacement MCCB 4 pole 415 volts fixed type 25-100 Amps with braking capacity16 KA, thermal release adjustable from 80 to 100% & fixed magnetic release with Ics = 100% Icu , including spreaders after taking out old U/S one all as specified and directed.
All as per Srl item No 50 above but 125 amps.
All as per Srl item No 50 above but 160 amps.
S&F in replacement MCCB 4 pole 415 volts fixed type 200 Amps with braking capacity 25KA thermal release adjustable from 80 to 100% & magnetic release adjustable from 5 to 10 In with Ics-100% Icu, including spreaders after taking out old U/S one all as specified and directed.
All as per Srl item No 53 above but 250 amps.
Fixing only MCCB,415 volts,3/4 pole, 160/250/400 Amps after removing burnt/unserviceable MCCB from LT panel of any type,provided with spreader links and other accessories from OEM complete all as specified and directed. Note : MCCBs shall be issued under Sch "B" for "Free for fixing" from MES store. Cost of spreader links and other accessories shall deemed into quoted rate.
S&F in replacement MCB SP 6-32 Amps, "C" grade, 10 KA breaking capacity, 240 volts AC.
S&F in replacement MCB SP 40-63 Amps, "C" grade, 10 KA breaking capacity, 240 volts AC.
S&F in replacement MCB SPN 6-32 Amps, "C" grade, 10 KA breaking capacity, 240 volts AC.
S&F in replacement MCB SPN 40-63 Amps, "C" grade, 10 KA breaking capacity, 240 volts AC.
S&F in replacement MCB TP 6-32 Amps, "C" grade, 10 KA breaking capacity, 240 volts AC.
S&F in replacement MCB TP 40 Amps, "C" grade, 10 KA breaking capacity, 240 volts AC.
S&F in replacement post top LED light fitting ,25 watts, Powder coated aluminum die cast and spun aluminum with clear / opal diffuser. Suitable for Landscape Lighting, 5700K CCT. IP65, 25 watts,230 volts,50 Hz complete making connections with and including PVC insulated & sheathed single core cable of size 1.5 Sqmm 3 run for phase, earth,neutral complete all as spd and directed.
S&F in replacement LED post top in spherical shape polycarbonate diffuser,retrofit & IP 65 protection., 20 watts,B 22 base ,230 volts,50 Hz complete making connections with and including PVC insulated & sheathed single core cable of size 1.5 Sqmm 3 run for phase, earth,neutral complete all as specified and directed.
M&L for Painting on steel tubular pole after sanded or etched and primed coated with a minimum of two finished coats of aluminium paint including writing pole No all as specified and as directed.
Dismantling and taking down security/street light fitting of any wattage or size from pole or highmast lights for repair and shifting to MES store and refix including and after checking all wiring and serviceability of all components and repair the minor fault if any or for replacement of burnt/unserviceable accessories all as specified and as directed. Note: Cost of burnt/unserviceable items shall be measured seperately.
S&F in replacement Open construction HPSV ballast,70 watts, 220/240 volts AC, 50 Hz..
S&F in replacement Open construction HPSV ballast,150 watts, 220/240 volts AC, 50 Hz. .
S&F in replacement Open construction HPSV ballast,250 watts, 220/240 volts AC, 50 Hz..
S&F in replacement lamp HPSV 70 watts, 220/240 volts AC, 50 Hz..
S&F in replacement lamp HPSV 150 watts, 220/240 volts AC, 50 Hz. .
S&F in replacement lamp HPSV 250 watts, 220/240 volts AC, 50 Hz. .
S&F in replacement Ignitor HPSV light fitting, 230 volts, 50 Hz .
S&F, LED driver,230 Volts , AC, 50 Hz, IP -54, suitable for street light fittings, 20-50 Watts.
S&F, LED driver,230 Volts , AC, 50 Hz, IP -54, suitable for street light fittings, 60-90 Watts.
S&F in replacement T5 Lamp, 2' long, 14/18//24/28 Watt, 230 volts,50 Hz Cool day Light.
S&F in replacement Electronic Ballast, T5 2x 24 / 2x 28 watts.
S&F in replacement Electronic Ballast, T5 2x14 / 2 x 18 watts.
S&F in replacement Electronic Ballast, 1x28 watts.
S&F in replacement Electronic Ballast, 1x 36/40 watts.
S&F in replacement fluorescent lamp 28 watt,230 volts AC, 4' long .
S&F in replacement fluorescent lamp 36/40 watt,230 volts AC, 4' long .
S&F in replacement fluorescent lamp 36/40 watt,4 pin, 230 volts AC .
Supply, install, testing and commissioning in replacement LT feeder pillar box, outdoor type, floor mounted, made out of CRCA sheet 3.15 mm thick, CPRI approved,weather proof,dust and vermin proof, IP -65, powder coated with 7 tank process, with common elecrolytic, sleeve insulated Copper bus-bar for 3 phase ,4 wire system,415 volts AC, both sides openable,double door and locking arrangements for each compartment, prewired with Copper cable not less thatn 4.0 sq mm, provided with danger notice plate, panel mounted on angle iron frame fabricated out of 40x40x6mm size with leg 90 cm long, 30 cm embedded and secured in PCC foundation. Size of panel shall suitable to accommodate and comprising the following components :- (a) MCCB 100 Amps, 4 pole,16 KA, 415 volts, 50 Hz with spreaders - 01 No (Incomer). (b) MCB TP 20 Amps, 16KA, 415 volts, 50 Hz - 02 Nos (Outgoing).
Supply and fixing in replacement street light mounting bracket ,fabricated, made out of GI pipe, light grade,40/50 mm bore dia,150 cm long for mounting on PCC/Steel poles incl 02 X MS clamps of 30x5mm size with nut, bolt, washers etc and painting with two coats of aluminium paint over a coat of red oxide complete all as specified and directed.
Supply and fixing in replacement street light mounting bracket ,fabricated, made out of GI pipe, light grade,25/32 mm bore dia,150 cm long for mounting on PCC/Steel poles incl 02 X MS clamps of 30x5mm size with nut, bolt, washers etc and painting with two coats of aluminium paint over a coat of red oxide complete all as specified and directed.
S & F in replacement pole mounted street light junction box, Hot press, moulded SMC, side hinged door, suitable for outdoor PCC/Steel poles including Aluminium bus bar, 4 wire, 200 Amps, MCB SP,230 volts,10 Amps, "C" curve -01 No, minimum internal dimension 300 x 200 x 105 mm with printed sign of skull and bones for danger notice including 02x Clamp made out of MS bar 30 x 5 mm size suitable to fix on steel/PCC pole all as specified and as directed.
Supply, fixing, testing & commisioning of LED based Flood light, housing made up of pressure die cast aluminium with effective thermal management, sturdiness and embossed brand name/logo name of manufacturer. The fixture should have a minimum system efficacy of 110 lumen/Watt and a minimum system lumen output of 11000 lumens and maximum system wattage of 100 Watt. The fixture shall have a CRI of minimum 70; SDCM<5; Color temperature should be of 5700K. The fixture shall be designed for a system life of 50,000 hours @L70B50. Ingress Protection of IP66 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK07. The fixture driver should have an operating voltage range of 140-270 V, surge protection of >=4KV, PF >0.9 and THD<10%. The fixture should comply with the parameters as per IS10322. The LED driver should have Fixed output, High Cut @325V , capable to withstand 440V for 8 Hrs and auto restart feature. Driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.Suitable arrangement to be made for fixing of light in existing bracket. The Luminaires shall be aesthetically appealing and should have no extremal visible fins. LED's, driver and fixture should be BIS approved and same make, complete making connections with street light terminal box with and including PVC insulated & sheathed single core cable of size 1.5 Sqmm 3 run for phase, earth,neutral complete all as spd and directed.
Excavating in trenches in soft / loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation of poles, trenches for laying of cable, or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
All as per Srl item No 88 above but n exc 1.5 m wide and exc 1.5 m and n exceeding 3.0 m in depth.
Removing excavated material to a distance not exceeding 50 Mtr and deposting where directed at a level not exc. 1.5 mtr above the starting point.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each all as required and directed.
Supply of brick sub class 'B' laid dry in trenches over the cable adjoining each other widthwise for cable protection complete all as specified and as directed.
M&L for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed.
Material and Labour for PCC 1:4:8 type D-2 using 40 mm graded stone aggregrate for foundation filling as mass concrete including necessary form work complete all as specified.
Material and Labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregrate for coping of poles and foundation of stay complete all as specified.
M&L in replacement PVC insulated, FR PVC round sheathed, stranded Copper flexible conductor industrial cable,1100 volts grade, confirming to IS 694, 3 core, 1.5 sqmm for connecting light fitting with junction box or OH conductor drawn through and including provision of rigid PVC conduit of 20 mm duly secured with pole by means of MS clamps at 1 meter distance all as specified complete and as directed.
Trimming up of tree branches upto 3 mtr all around LT overhead lines including provision of cutting tools, supports and safety equipments, removing cut branches from site as directed. Note :- (i) The overhead lines shall be kept 3 meter clearance from the tree branches. (ii) Permission for shut down shall be informed to the concerned substation prior to the trimming and written permit shall be obtained by the contractor. (iii) Measurement shall be accountable for trimmed span only.
S&F in replacement, contactor,25 Amps, Auxilary Contacts suitable to fixing in existing street light control timer panel as per existing sample all as specified and directed.
S&F in replacement, contactor,3 pole ,40 Amps,415 volts suitable to fixing in existing street light control timer panel as per existing sample all as specified and directed.
S&F in replacement control relays, 10 Amps, with suitable coil to fixing in existing street light control timer panel as per existing sample all as specified and directed.
S&F in replacement overload relay of any range suitable to fix in existing street light control timer panel all as specified and directed.
S&F in replacement Time switch, analog type, 1P/3P Module, 24 hours program, Programmable every 15 min backup of 100 hours, current capacity 16A, with 1 changeover (1 CO) suitable to fixing in existing street light control timer panel all as specified and directed.
S&F in replacement street light timer panel with all components, 230 volts AC, 50 Hz, 32A 3 Pole, 230V, Astronomical type, Programmable every 1 min., backup of 6 years, 28 memory locations with 1 changeover (1 CO), Total 28 programs complete all as specified and directed.
S&F in replacement street light timer panel with all components, 230 volts AC, 50 Hz, 65 A 3 Pole, 230V, Astronomical type, Programmable every 1 min., backup of 6 years, 28 memory locations with 1 changeover (1 CO), Total 28 programs complete all as specified and directed.
Repair to existing street light timer control panel at site by inspecting serviceability of each component and rectify the faults if any including replacement of unserviceable parts with new one complete all as specified and as directed. Note: Cost of new components shall be measured under relevant item.
Boring of Holes under road, Pavement, hard Standing by mannual/ trenchless technology using ultra Sound technique and necessary machine including providing and insertion of HDPE pipe 100mm dia complete all as specified and as directed.
M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of earth plate not less than 1.5 meters below ground level connected by 25X4 mm GI strip as earth lead by means of nuts and bolt,thimbles, check nuts, washers of GI or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20 mm graded stone aggregate,with fair finish,internal surface of concrete chamber shall be given internal dia 300mm x 300 mm dia,15 mm thick plaster in CM 1:4 funnel with wire guage mesh ,80 mm thick RCC pit cover 320mm x 320 mm of RCC 1:2:4 Type B1 using 20 mm graded stone aggregate reinforced with XPM jelly and charcoal ,dust and common salt all as shown in electrical plate No 5 of MES SSR Part -1 (1991) and specified including provision of GI strip upto 7.5 metre long protected by 40 mm dia medium grade pipe and watering pipe shall be 20 mm bore medium grade ,including all excavation and earth work and connecting the earthing to an earthing test point and to main switch board as specified and testing on completion complete all as specified and directed. Note: RCC pit cover shall be precast of RCC (1:2:4) type B1, 80 mm thick reinforced with XPM weighting not less than 4 kg/Sqm in lieu of CI cover.
M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of earth plate not less than 1.5 meters below ground level connected by 32 X6 mm GI strip as earth lead by means of nuts and bolt,thimbles, check nuts, washers of GI or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20 mm graded stone aggregate,with fair finish,internal surface of concrete chamber shall be given internal dia 300mm x 300 mm dia,15 mm thick plaster in CM 1:4 funnel with wire guage mesh ,80 mm thick RCC pit cover 320mm x 320 mm of RCC 1:2:4 Type B1 using 20 mm graded stone aggregate reinforced with XPM jelly and charcoal ,dust and common salt all as shown in electrical plate No 5 of MES SSR Part -1 (1991) and specified including provision of GI strip upto 7.5 metre long protected by 40 mm dia medium grade pipe and watering pipe shall be 20 mm bore medium grade ,including all excavation and earth work and connecting the earthing to an earthing test point and to main switch board as specified and testing on completion complete all as specified and directed. Note: RCC pit cover shall be precast of RCC (1:2:4) type B1, 80 mm thick reinforced with XPM weighting not less than 4 kg/Sqm in lieu of CI cover.
M&L in replacement Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including and after taking out old strip all as specified and directed.
Supply & fix in replacement GI strip 32x6 mm,complete with saddles/ insulators made out of porcelain or fibere and buried in ground or fixed to wall etc for loop earthing including and after taking out old strip all as specified and directed.
M/S Vijay Punj Constructions
Vijay Kumar Contractor and Engineers
KULBHUSHAN AGGARWAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .