Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹21.1 LAccepted-AOC PATOLI BRAHMANA WARD NO 02 PO MUTHI TEH DISTT JAMMU J K PIN 181205 | JAMMU | JAMMU AND KASHMIR | 181205 | L-1 | Accepted-AOC Being lowest bidder | |
| 2 | L-2₹21.9 L+₹72,991 (3.46%)Rejected-Finance SIMBAL CAMP WARD NO 5 NEAR GURUDWARA SAHIB R S PURA DISTT JAMMU J K 1812104 | R S PURA | JAMMU | J K | 1812104 | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹26.3 L+₹5.1 L (24.3%)Rejected-Finance | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹26.3 L+₹5.2 L (24.5%)Rejected-Finance 201 GANAPATI SANKUL AGASHIVNAGAR MALKAPUR KARAD SATARA MAHARASHTRA 415539 | SATARA | MAHARASHTRA | 415539 | L-4 | Rejected-Finance Other than lowest bidder | |
| 5 | L-5₹28.1 L+₹6.9 L (32.9%)Rejected-Finance | L-5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
30 Nov 2024, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-900277
REPAIR / REPLACEMENT OF INTERNAL WIRING WITH FITTING AND FIXTURES DBs SUB MAIN WIRING, METER BOXES AND SERVICE CABLE IN OTM ACCN AT DAMANA UNDER GE JAMMU
2024_MES_679447_1
GEJC-56/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
GE Jammu
₹90,000
Yes
30 Dec 2024
30 Oct 2024
2 Dec 2024
30 Oct 2024
30 Nov 2024
13 Nov 2024
Amount
Taking down old unserviceable copper / aluminium point wiring concealed / batten (light, fan, socket or power) complete including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type of switch board wooden / iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
Taking down carefully unserviceable distribution board of any type / size with MCB's and disconnecting and making good disturbed surfaces complete all as specified and as directed.
Material and labour for complete point wiring with 1.5 Sqmm single core multistranded copper conductor FRLS insulated and unsheathed heavy duty cable in colour code including continuous earth wire with cable of size 1.5 Sqmm copper conductor flexible FRLS insulated drawn in and including concealed PVC rigid conduit medium grade ISI marked after cutting chases in wall, plastering after concealing conduit, including modular galvanised flush boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc and including making good the disturbed surface as per existing complete all as specified and as directed by Engineer-in-Charge for the following: -
Description all as per Ser item No 3.00 here-in-before but for multi 5 pin 5 amp socket outlet on same board ISI marked complete all as specified and as directed.
Description all as per Ser item No 3.00 here-in-before but for multi 5 pin socket outlet 5 amp socket on independent board ISI marked complete all as specified and as directed.
Description all as per Ser item No 3.00 here-in-before but for one bell / buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 Sqmm size complete all as specified and as directed.
Description all as per Ser item No 3.00 here-in-before but for multi 6 pin 15 Amp socket outlet independent controlled by 15 Amp switch with 2.5 Sqmm copper conductor multistranded cable PVC insulated FRLS and unsheathed cable in and including PVC rigid concealed conduit 20/25 mm dia and unsheathed copper conductor multistranded cable 2.5 Sqmm as earth wire FRLS PVC insulated in green color complete all as specified and as directed by Engineer-in-Charge.
Material and labour for point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into existing concealed PVC rigid / steel conduit and into existing cast iron / pressed steel sunken / terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed.
Description all as per Ser Item No 8.00 here-in-before but for one 5 pin socket outlet 5 amps on the same board complete all as specified and as directed.
Description all as per Ser Item No 8.00 here-in-before but for one 5 pin socket outlet, 5 amps, independent complete all as specified and as directed.
Description all as per Ser Item No 8.00 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.
Supply and fixing in repair modular socket, 6A - 5 pin combined 2 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in repair modular switch 1 module 6 A, 1 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in repair modular bell push 6 A, 1 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in repair ceiling rose, 3 Pin / PVC / polycarbonate isolated body ISI marked complete all as specified and as directed.
Supply and fixing in repair modular switch 1 way 16 A, 1 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in repair modular socket 6 A / 16 A - 6 pin combined 2 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in repair calling bell Ding Dong / buzzer AC 230 Volts, single pole ISI marked complete all as specified and as directed.
Material and labour in repair for lamp holder, modular type, PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Supply and fixing in repair LED light fitting 1 x 20 W, 220 V, AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor > 0.9, 100 Lumen / Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fixing in repair of vertical distribution board (V.TP&N) 4 way double door suitable for TPN 4 pole 125 Amp 16 KA four pole as incomer, it should be IP-43 protected with copper bus bars, neutral links, earthing bar complete all as specified and as directed.
Material and labour in repair earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 metre deep below normal ground level with top edge of the earth plate not less than 1.5 metre below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 precast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion all as specified and as directed.
Supply and fixing in repair LED light fitting 10 W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing in repair 415 V, 10 KA 'B' curve miniature circuit breaker (MCB) TPN 4 Pole, upto 125 Amps of following poles and current carrying capacity in the distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in repair fan step regulator, 100 W - 1 module 240 volts ISI marked complete all as specified and as directed.
Material and labour in repair for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 Sqmm 2 core complete all as specified and as directed by Engineer-in Charge.
Material and labour in repair for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 6 Sqmm 2 core complete all as specified and as directed by Engineer-in Charge.
Material and labour in repair for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 4 Sqmm 2 core complete all as specified and as directed by Engineer-in Charge.
Material and labour in repair for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 6.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and as directed.
Material and labour in repair for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 4 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and as directed.
Material and labour in repair for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 2.5 Sqmm for phase and neutral and one run of 2.5 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and as directed.
Supply and fixing in repair LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable and flexible pipe of suitable size complete all as specified and as directed.
Supply and fixing in repair wall mounted decorative type luminaries IP-65 with diffuser 10 watt, 230 Volts LED type complete with 10 watt LED bulb complete all as specified and as directed by Engineer-in-Charge. Note: - The cost of LED lamp, 10 watt deemed to be included in the quoted rates.
Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof, ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
Material and labour in repair distribution board, double door, made of 2mm thick stainless steel sheet, powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Material and labour in repair distribution board, double door, made of 2mm thick stainless steel sheet, powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Material and labour in repair distribution board, double door, made of 2mm thick stainless steel sheet, powder coated for MCB with copper bus bar and neutral link earthing stud SPN 6 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Material and labour in repair distribution board, double door, made of 2mm thick stainless steel sheet, powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing in repair 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp, in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in repair 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 Amp, in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in repair SPN 32 Amp rating 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in repair SPN 40 to 63 Amp rating 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in repair for switch piano, flush type single pole one way 5 Amp, 240 volts complete all as specified and as directed.
Supply and fixing in repair socket outlet 2 in 1, 3 pin, 5 A complete all as specified and as directed.
Supply and fixing in repair switch socket outlet combined 5 pin 5 amp flush type, 240 volts complete all as specified and as directed.
Supply and fixing in repair switch socket outlet combined 2 in 1, 3 pin 5 amp and 15 amp flush type, 240 Volts complete all as specified and as directed.
Material and labour in repair for lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep in loose / soft soil and getting out for underground cable / erection of poles, stays etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for sand cushioning for cable with river washed sand and punning to provide required cover as per SSR Part-I complete all as specified and as directed by Engineer-in-Charge.
Supplying and laying bricks common burnt clay sub class 'B' old size for cable protection complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.
Removal of excavated material not exceeding 50 metre away and depositing where directed at a level not exceeding 1.5 metre above from the starting point complete all as specified and as directed by Engineer-in-Charge.
Disconnecting and taking out defective underground cable any size and any type from trenches, roof, pole, pipe, floor, wall etc complete all as specified and as directed.
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 10 Sqmm 4.0 core laid in trenches / on poles / road crossing or passing through existing / new pipe under road crossing, clamping on wall etc complete all as specified and as directed.
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 Sqmm 4.0 core laid in trenches / on poles / road crossing or passing through existing / new pipe under road crossing, clamping on wall etc complete all as specified and as directed.
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 25 Sqmm 3.5 core laid in trenches / on poles / road crossing or passing through existing / new pipe under road crossing, clamping on wall etc complete all as specified and as directed.
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 35 Sqmm 3.5 core laid in trenches / on poles / road crossing or passing through existing / new pipe under road crossing, clamping on wall etc complete all as specified and as directed.
Disconnecting and taking out defective service cable any size and any type from roof, pole, pipe, floor, wall etc complete all as specified and as directed.
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 10 Sqmm 2 core laid in trenches / on poles / road crossing or passing through existing / new pipe under road crossing, clamping on wall etc complete all as specified and as directed.
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 Sqmm 2 core laid in trenches / on poles / road crossing or passing through existing / new pipe under road crossing, clamping on wall etc complete all as specified and as directed.
M/s Sahib Construction and engineers (BID ID -3172697)
Harsh Electricals (BID ID -3170682)
Prakash Trading Corporation (BID ID -3171841)
Sarbat Construction Co (BID ID -3167522)
BMMJ TRADERS AND ENGINEERS (BID ID -3169345)
M/s K K CONSTRUCTION (BID ID -3171127)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .