Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC N0 15 ASHOK NAGAR MAIN ROAD MES ROAD 3RD CROSS STREET EAST TAMBARAM CHENNAI 600 059 | CHENGALPATTU | TAMIL NADU | 600059 | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.2 L+₹10,945.98 (0.57%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹19.9 L+₹76,542.50 (4.01%)Rejected-Finance VPO MAJOD TEHSIL HANSI DISTRICT HISAR 125049 HARYANA | HISAR | HISAR | HARYANA | 125049 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹20.9 L+₹1.8 L (9.48%)Rejected-Finance NO 17 PETER GNANA PRAKASAM NAGAR MARIYAMMAN KOVIL PO THANJAVUR 611501 | 611501 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹21.9 L+₹2.8 L (14.7%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹23.6 L
EMD Value
₹47,200
Closing Date
22 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Air Force
Garrison Engineer Air Force
ADDITION ALTERATION TO BLDG No. P-128 AT AFS THANJAVUR
2024_MES_643910_1
8111/E8
Open Tender
Civil Works
Item Rate
180 days
Thanjavur
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer Air Force
₹47,200
29 Apr 2024
23 Feb 2024
23 Mar 2024
23 Feb 2024
22 Mar 2024
9 Mar 2024
Amount
Dismantling floor hearth or wall tiling including cement mortar bedding / backing removing serviceable tiles to store & rubbish of the premises complete all as specified and directed.
M & L for Vitrified Ceramic tiles dark shade 10mm thick (square / rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick screed bed in CM 1:4 to recieve tiles complete all as specified and directed.
All as per srl item no 02 here-in-before but in skirting over back coat of 10mm thick in CM 1:3 complete all as specified and directed.
S&F coloured Non Skid ceramic tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.18sqm but not exceeding 0.38sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in CM (1:4) to recieve tiles complete all as specified and directed.
All as per srl item No 04 here-in-before but in skirting over back coat of 10mm thick in CM 1:3 complete all as specified and directed.
Taking down plastering on lathing (other than wire-netting) less than 10mm thick , without removing lathing, in cement mortar complete all as specified and directed.
M & L for Vitrified chequered tiles (7 to 10 mm thick (square / rectangular) area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick screed bed in CM 1:4 to recieve tiles complete all as specified and directed.
M & L for chequered cement concrete tiles 300mmx300mm of 25mm thick,set, jointed and pointed in neat cement slurry in floors and pointed in white or coloured cement to match and including 20mm thick screed bed in CM 1:4 to recieve tiles complete all as specified and directed.
Taking down chowkhats or frames not exc. 1.5 sqm each but with shutters (without taking off shutters from the frames)all as specified and directed.
Supply and fixing factory made uPVC white colour fixed glazed window / ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8mm size for fixing frame to finished wall, plastic packers,plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per specification complete all as specified and directed. (Glass shall be paid separately). Note:- For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Taking down aluminium partition of any description complete all as specified and directed.
Taking down steel rolling shutter of any description of area exc 10sqm and not exc 15sqm complete all as specified and directed.
M & L for Plain, solid, straight chowkats using 1st class hardwood (teak) and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned adjoints, supplied and fixed complete all as specified and directed.
M & L for glazed and skeleton shutters sing 1st class hardwood (teak), open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain,chamfered or rounded. fitted withcut and mitred beads for securing glass,etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed.
M & L for plain Sheet glass of 5.5mm thick, ordinary quality and glazing with oil putty in square exc 0.5sqm in each pane complete all as specified and directed.
M & L for solar control film 25 micron reflective type exc 1.5sqm sticked to glass panes as per instructions of manufacturers complete all as specified and directed.
S & F MS hold fast similar small articles confirming to Fe 290 Gde -E- 165 complete all as specified and directed.
M & L brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in CM 1 : 6 complete all as specified and as directed.
M & L for rendering 10mm thick on fair faces of brick Work or concrete surface and finished fair & even in CM 1:6 complete all as specified and as directed.
M & L for preparation of new surfaces of walls and applying two finishing coat of oil bound distemper on walls, incl priming coat complete all as specified and directed.
M&L preparation of old decorated wall surfaces and applying one coat of distemper oil emulsion on walls complete all as specified and as directed.
M & L for preparation of surfaces on ceilings including cornices, etc and applying one finishing coat of white wash complete all as specified and directed.
M & L for preparation of old wooden surfaces of any description, not otherwise described, exceeding 10cm in width or girth and applying one finishing coat of synthetic enamel paint on wooden surfaces, complete all as specified and directed.
M & L for preparation of old painted steel and iron surfaces of any description exceeding 10 cm in width or girth and applying one finishing coat of synthetic enamel paint on steel surfaces complete all as specified and directed.
Demolition of Concrete in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified
M&L 75mm thick PCC 1:3:6 type C-2 (using 40mm graded agg) as in plinth protection and finished using extra cement complete all as specified and directed.
M&L Solid PVC Wall Lining of any colour and texture consisting of 5mm thick grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications complete all as specified and directed.
M & L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification complete all as specified and directed.
M & L for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre / intermediate channel 0.9mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55 mm thickness having curled web of 50 mm and flange of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed. Note:- Hangers will be measured and paid seperately.
Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I flat 40 x 3 mm size and not more than 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
Providing and fixing Non asbestos fibre cement building boards of 4mm thick fixed or laid/ inserted to timber/GI/Aluminium framework with screws for flat/ sloped ceiling complete all as specified and directed.
M&L preparation of old decorated surfaces of walls and applying one coat of cement based paint on wall (External borders is required dark blue or existing colour) all as specified and as directed.
S & F of brass skeleton tower bolts of 375mm size with cast brass plate and staples and rolled or drawn brass bolt and fixed complete all as specified and directed.
S & F of Butt hinges, cast brass 125mm size, with mild steel hinge pin, bright polished and fixed, type c-11 complete all as specified and directed.
S & F of Mortice lock with four levers (vertical type) brass body of size 65mm and fixed complete all as specified and directed.
S & F extruded brass handles,150mm long fabricated type polished complete all as specified and directed.
M & L for preparation of new wooden surfaces of any description, not otherwise described, exceeding 10cm in width or girth and applying two finishing coat of synthetic varnish on wooden surfaces over filler coat of wood filler liquid transparent, complete all as specified and directed.
Demolition of cement Concrete (reinforced) n. exc. 15 cm thickness below or above ground level complete all as specified and directed.
M & L for Providing precast cement concrete using type C1, 1:3:6 (20mm aggregate) in landings, coverslabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed.
Mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M & L for aluminium door closer hydraulically regulated (extruded section), designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
M & L for floor door stopper of size 150mm of brass body and tongue with hard drawn steel spring fixed in floor complete all as specified.
Taking down carefully aluminum / copper point wiring (light ,fan, socket any type, power, bell etc. ) complete including fixtures & fittings (such as ceiling rose, socket, Pendent, regulator, light fitting etc) and removing the material from site and making good the disturbed surfaces of walls ceiling etc complete all as directed.
Taking down carefully by unscrewing from boards outlet boxes like AC enclousers boxes / DB any size and type / any descriptions including MCB any type / size and making good disturbed surface / wall as per existing complete all as specified and directed
M & L for Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed (FRLS) cable, multi-stranded, copper conductor, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia med gd)and its all accessories complete concealed in wall,roof etc (making good all to the disturbed surfaces as per existing) and including modular flush metal boxes,modular frame cover & plates suitable for modular fittings, concealed type for mounting modular switches, sockets etc (after wall wall panelling & Civil work) including earth wire of PVC insulated (FRLS) copper conductor multistranded of 1.5 Sqmm size in green colour complete all as specified & directed, as described below:-
One light point controlled by one way switch 5 amp complete.
One 3 pin 5 Amps socket point controlled by one other switch on same board.
One 3 pin 5 Amps socket point controlled by one switch on independent board.
All as per srl item No. 45 but for 3 pin / 5 pin 16 Amps independent sockets outlet point with 4 Sqmm PVC insulated & unsheathed (FRLS) copper conductor cable independent complete all as specified and as directed.
Supply and Fixing Modular switch 6 Amps single pole one-way, 1 Module complete all as specified and directed.
Supply and Fixing Modular switch 16 Amps single pole one way,1 Module complete all as specified and directed.
Supply and Fixing Modular socket 2-in-1, 5 pins 6 Amps, combined 2 Module complete all as specified and directed.
Supply and Fixing Modular socket 2-in-1,3 and 5 pins 6 /16 Amps, combined 2 Module complete all as specified and directed.
Supply and Fixing ceiling rose surface bakelite with three terminals complete all as specified.
Supply and fixing decorative recessed mounted LED Panel light of 600 mm x 600 mm, 35/36 watt, 220 V AC with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp, operating Voltage 140V to 270 Volt, short circuit protection , surge protection suitable for roof ceiling including connecting up with driver three core flexible copper conductor of suitable size complete.
Taking down wall mounting fan, sealing cable end and refixing at existing site after wall panelling work including suitable screws, back plates and flexible wire loop for connection as per site requirment and making good the disturbed surfaces of walls/ ceiling etc complete all as directed.
Taking down ceiling fan complete with down rod, dismantling blade and deposited to MES store yard as directed complete.
S&F MCB distribution board, TPN 8 Way, Double door, sheet steel, powder coated painted with Copper bus-bar 200Amp, neutral link, earth bar and din rail ,cable ties for cable management, 415 V, complete all as specified.
S&F MCB distribution board, SPN 8 Way, Double door, sheet steel, phosphatised, powder painted with Copper bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified.
Supply & fixing MCB SP 5-32 Amps, ' C' series ,bracking cap10KA, 240V complete all as specified and directed.
Supply & fix MCB TPN / FP 63 Amps,' C' series , bracking cap10KA, 415V complete all as specified and directed.
Supply & fix MCB SPN 40 Amps,' C' series , bracking cap10KA, 240V complete all as specified and directed.
M & L for Sub Main Wiring for AC / Eqpt. Power with two runs single core 4 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in suitable size of rigid non-metallic PVC conduit and its all accessories complete concealed in wall/roof with and including 4 Sqmm copper green colour earth wire complete with connection all as specified and directed (02 run 4 Sq mm single core cable, one run of 4 Sq mm earth wire & One run of PVC conduit will measured as one RM).
M & L for Sub Main Wiring with two runs single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in suitable size of rigid non-metallic PVC conduit and its all accessories complete concealed in wall/roof with and including 6 Sqmm copper green colour earth wire complete with connection all as specified and directed (02 run 6 Sq mm single core cable, one run of 6 sqmm earth wire & One run of PVC conduit will measured as one RM).
M&L for earthing complete with galvanized steel earth plate electrode size 600 mm x 600 mm x 6.3 mm thick buried directly in ground vertically in a pit of depth not less than 2.25m below ground levels with top edge of the earth plate not less than 1.5m below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron wire 4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 15mm dia connected to main earth lead on pole or control board and GI pipe light grade 20mm dia for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC (1:3:6) type C-2 including necessary excavation and earth work all as shown in electrical plate No 3 connected to earthing test point and testing on completion complete all as specified & directed. Note :- GI wire and protection pipe upto 7.5m length from earth electrode shall be included in quoted rate of item.
Supply and fix modular power socket unit 16 Amp complete with SP MCB of rating 20 Amps, 240 Volt including with top plug 16Amp complete with all connection incl cutting & chases (making good all to the disturbed surfaces as per existing) as directed.
Taking down the split AC unit (any type capacity) carefully from its installed position, dismantling complete with base frame, inlet & outlet refrigent copper tube, electrical connections including stabilizer and keeping a side safely and carried out general servicing of indoor & outdoor unit and refixing at existing or dirverted location after wall panelling work with suitable arrangements for fixing of base frame and all connection and testing after installation complete. Note :- (a) Any damages/broken of any parts of AC during the work, contractor will be responsible for the repair of the same or replaced with new without any extra cost. (b) Necessary arrangement / modification work for fixing of indoor unit after wall panelling work wiil be included in quoted rate.
Supply & fix wall mounting Air Circulator fans BLDC type, single phase 230 volt and 450mm sweep complete with connection.
Kaadosh Real Estates Pvt Ltd
VIKAS INFRASTRUCTURE
M/S. SRI RAMANUJA CONSTRUCTIONS
NITHYASRI AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .