Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹37.0 L+₹3.7 L (11.1%)Rejected-AOC FLAT NO 06 BLDG NO B 2 PLEASANT PARK WANWADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L2 | Rejected-AOC NOT BEING LOWEST | |
| 3 | L3₹37.4 L+₹4.1 L (12.3%)Rejected-AOC | L3 | Rejected-AOC NOT BEING LOWEST | |
| 4 | L4₹37.7 L+₹4.4 L (13.2%)Rejected-AOC | L4 | Rejected-AOC NOT BEING LOWEST | |
| 5 | L5₹38.8 L+₹5.5 L (16.6%)Rejected-AOC | L5 | Rejected-AOC NOT BEING LOWEST |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
22 Jul 2023, 6:00 pmClosed
GE AF LOHEGAON
GE AF LOHEGAON LOHEGAON PUNE-411032
REPAIR, REPLACEMENT AND MAINTENANCE OF DEFECTIVE EXTERNAL WATER SUPPLY PIPELINE AND VALVES,MISC ITEMS AT VIMAN NAGAR,509 AND 1020 AREA, 9BRD AND WSA OF 2 WING AFS PUNE UNDER GE (AF) LOHEGAON
2023_MES_607265_1
8732
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
2WING AND 9BRD
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE AF LOHEGAON
₹72,000
Yes
28 Dec 2023
30 Jun 2023
26 Jul 2023
30 Jun 2023
22 Jul 2023
17 Jul 2023
Amount
Taking up or down unserviciable / old GI tubing any grade and fittings connections ( including dewatering of trench) and removal from site all as directed by Engr-in-charge.
15mm dia bore
20 mm dia bore
25mm dia bore
40mm to 80mm dia bore
Taking up or down unserviciable / old GI tubing any grade and fittings connections including cleaning for re-fixing or removal from site all as directed by Engr-in-charge.
15 mm dia bore
20 mm dia bore
25mm dia bore
40mm to 50mm dia bore
Supply & lay and jointing tubing medium grade galvanised iron pipes, ISI marked with all fittings such as bends, tees, elbows, nipple, unions, short pieces, sockets etc and laid in trenches all as specified of following sizes :-
15mm dia bore
20 mm dia bore
25mm dia bore
40mm dia bore
50mm dia bore
80mm dia bore
Taking up cast iron water mains with fittings ( including dewatering of trench) with spigot and socket ends and lead joint including burning out joints and recovering lead.
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
M&L for Caulking existing leaking lead joint including jointing materials such as lead, lead wool, spurn yarn for the following sizes of CI pipe lines complete all as directed.
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
M&L bends (any type, radius and angle) tapers any type (straight bend, increasing, decreasing or double socked etc) tee pieces , single branch, junction, double branch, cross ( all sockets or socket and spigot) collars, caps plugs suitable for the pipe upto 150 mm bore.
M&L bends (any type, radius and angle) tapers any type (straight bend, increasing, decreasing or double socked etc) tee pieces , single branch, junction, double branch, cross ( all sockets or socket and spigot) collars, caps plugs suitable for the pipe 200 mm to 300 mm bore.
Taking down and S&F PVC Float valves , high pressure ,with polythene float and flynut complete ,screwed for iron pipe of size:
a)15 mm dia
b)20 mm dia
c) 25 mm dia
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil for cleaning surface area and cutting shurbes/grass & bushes and remove the material at various installation at site. all as directed by Engr-in-charge.
Taking down unserviceable gun metal gate valves including S & F gun metal gate valves with iron wheel head screwed both end for iron pipe and fixed.
a) 20mm dia bore
b) 25mm dia bore
c) 40mm dia bore
d) 50mm dia bore
Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth for laying of GI tubing / taking out of GI tubing and getting out in
a) Soft /loose soil
b) Hard / dense soil
c) Soft disintegrated soil
Returning filling in including spreading levelling, watering and well ramming in layers n. exc 25cm with soil obtained from excavation complete all as specified and directed.
Removing excavated soil / material n. exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above the starting point.
Demolishing or dismantling Concrete in ground floors and pavings n exc 15 cm thickness
M&L for Cement concrete D-2 (1:4:8) using 40mm graded stone aggregates as in foundations, filling and mass concrete complete all as specified and directed.
M & L for taking out unserviceable butterfly valve and replace with new butterfly valve of same dia including all nuts and bolts of following sizes:-
a)50mm dia size
b) 80 mm dia size
b) 100 mm dia size
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
M&L for Construction of brick masonry valve pit inside measurement 1.2 m x 1.2 m x 90 cm in replacement complete with MS Sheet 3.00 mm thick cover and angle iron frame (40m x 40mmx 40mm) as per existing size including locking arrangement suitable for sluice valve 200 mm to 300mm and sheet cover with one coat of red oxide and two coat of Synthetic enamel paint and complete leveling refilling the unwanted existing trenches ,as per ground requirement including demolition of existing/old valve chamber all as per direction by Engineer in charge.
M&L for Construction of brick masonry valve pit inside measurement 0.90m x 0.90m x 0.90m in replacement complete with MS Sheet 3.00 mm thick cover and angle iron frame (40m x 40mmx 40mm) as per existing size including locking arrangement suitable for sluice valve 80 mm to 150 mm and sheet cover with one coat of red oxide and two coat of Synthetic enamel paint and complete leveling refilling the unwanted existing trenches ,as per ground requirement including demolition of existing/old valve chamber all as per direction by Engineer in charge.
M&L for MS Mechanical Joint clamp of (minimum thickness of 6mm) type,flap type,GP joint type/any type as per site requirement for CI,DI Pipe of size 80mm along with MS nut bolt washer complete all as specified and directed.
M&L for MS Mechanical Joint clamp (minimum thickness of 6mm) type,flap type,GP joint for CI,DI Pipe of size 100mm along with MS nut bolt washer complete all as specified and directed.
M&L for MS Mechanical Joint clamp (minimum thickness of 6mm) type,flap type,GP joint type/any type as per site requirement for CI,DI Pipe of size 150mm along with MS nut bolt washer complete all as specified and directed.
M&L for MS Mechanical Joint clamp (minimum thickness of 6mm) type,flap type,GP joint type/any type as per site requirement for CI,DI Pipe of size 200mm along with MS nut bolt washer complete all as specified and directed.
M&L for MS Mechanical Joint clamp (minimum thickness of 6mm) type,flap type,GP joint type/any type as per site requirement for CI,DI Pipe of size 250mm along with MS nut bolt washer complete all as specified and directed.
M&L for MS Mechanical Joint clamp (minimum thickness of 6mm) type,flap type,GP joint type/any type as per site requirement for CI,DI Pipe of size 300mm along with MS nut bolt washer complete all as specified and directed.
M&L DI water pipes with spigot and socket ends including rubber gasket joint Class K7, in any length, including all fittings likes bend, elbow,tail piece,tee,reducer etc in trenches.
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
Taking out and S&F unserviceable CI sluice valve from exisiting position by opening the nuts , bolts and breaking of valve chamber including necessary earth work and excvation in any type of soil and S & F CI sluice valve with PN rating 1:6 conforming to IS 14846 duly ISI marked with iron wheel head HSS spindle and all other conected accessories such as gland packing, bolts, and nuts rubber gasket etc complete and making good the vlave chamber to match with the adjacent surface including brick / PCC block works, plastering etc for the following sizes complete all as directed .
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
Taking out water sample in clean container gettng the same tested from NABL accredited LAB for chemical and bacteriological test complete as per IS 10500: 2012 standard for drinking water and in case of STP water suitable for gardening all as directed by Engr -in-Charge.
Repairing of leakages/blockage GI pipeline of size 15 mm,20mm,25mm by replacing the Tees, bends, sockets, unions,nipple and providing the other materials required to complete the job including material, excavation and earth work either manually or by JCB complete all as per the direction of engr in charge. Notes:- a).Fitting required to rectify will be included in above item of size mentioned. b).Defect should be rectified within 24 hrs of intimation otherwise recovery of rupees @ 300 per day will be carried out. c). contractor should be responsible to rectify any defects at any place including restricted area in AF lohegaon.
Repairing of leakages/blockage GI pipeline of size 40mm,50mm by replacing the Tees, bends, sockets, unions,nipple and providing the other materials required to complete the job including material, excavation and earth work either manually or by JCB complete all as per the direction of engr in charge. Notes:- a).Fitting required to rectify will be included in above item of size mentioned. b).Defect should be rectified within 24 hrs of intimation otherwise recovery of rupees @ 300 per day will be carried out. c). contractor should be responsible to rectify any defects at any place including restricted area in AF lohegaon.
Repairing of leakages/blockage CI/DI pipeline of size 80mm to 300mm by replacing the Tees, bends, sockets, unions,nipple and providing the other materials required to complete the job including material, excavation and earth work either manually or by JCB/Machinery complete all as per the direction of engr in charge. Notes:- a).Fitting required to rectify will be included in above item of size mentioned. b).Defect should be rectified within 24 hrs of intimation otherwise recovery of rupees @ 300 per day will be carried out. c). contractor should be responsible to rectify any defects at any place including restricted area in AF lohegaon.
S&F Bib taps of size 15mm stainless steel crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed as per sample approvd by Engineer in charge.
Supply only Calcium Hypo Chlorite 65% chlorine content (Calcium based granular)
Supply and fixing of digital flow water meter of size 100 mm/150mm, including all the fittings reuired for replacement. Notes :- Cost incurred for testing of meter from PMC also included in quoted price
Labour only for maintenance servicing and overhauling of diesel engine for DG set cap of 10 KVA to 25 KVA, including cleaning OF DG set and fuel tank,descaling of battery terminals replacement of the spares etc and reassembling & alignment of the generator & engine including trial testing all as specified & directed at site by Eng - in - Charge . Note :- Cost of spares shall be measured & paid separately as supply only)
All as per item no 35 above but 40 KVA to 62.5KVA
All as per item no 35 above but 100 KVA to 160 KVA
Material only for the following item of DG set 10 KVA to 25 KVA to be incorporated in repairs for item No 35,
Air filter,Fuel Filter, Oil Filter element with 'O' ring
Fan belt
Alternator belt
Radiator hose pipe inlet/outlet
Solended switch 12 volts,DC
Oil Pressure Pipe
Deisel ,Fuel Pressure Pipe
Material only for the following item of DG set 40 KVA to 62.5 KVA to be incorporated in repairs.
Air filter,Fuel Filter, Oil Filter element with 'O' ring
Fan belt
Alternator belt
Radiator hose pipe inlet/outlet
Solended switch 12 volts,DC
Oil Pressure Pipe
Deisel ,Fuel Pressure Pipe
Material only for the following item of DG set 100 KVA to 160 KVA to be incorporated in repairs ,
Air filter,Fuel Filter, Oil Filter element with 'O' ring
Fan belt
Alternator belt
Radiator hose pipe inlet/outlet
Solended switch 12 volts,DC
Oil Pressure Pipe
Deisel ,Fuel Pressure Pipe
Supply only coolant for radiators.
Replacement of engine oil of grade as recommended by manufacturer for DG set any type any capacity.
Replacement of battery 12 Volt,150 AH and making all electrical connection testing complete all as directed
Replacement of battery 12 Volt,80 Amp and making all electrical connection testing complete all as directed
Replacement of battery charger 12 Volt,10 Amp and making all electrical connection testing complete all as directed
M&L for De-scaling & cleaning , painting (except fins area) & welding / soldering / brazing of radiator of any capacity & any type complete all as directed
Servicing and Maintenance of Dry air compressor by OEM or as directed by Engineer in charge . Notes :- servicing includes deep cleaning of equipment checking of electrical connection ,change of Oil and cupling connection,change all the parts as per OEM recommended 4000hrs kit.
Replacement of pre Filter having flow rate 125 CFM as directed by Engineer in charge.
Replacement of Fine Filter having flow rate 125 CFM as directed by Engineer in charge.
Replacement of Carbon Filter having flow rate 125 CFM as directed by Engineer in charge.
Servicing and Maintenance of Laminar Cum Fume hood big size by OEM or as directed by Engineer in charge. Notes :- Testing certificates need to be furnished by the contractor.
Servicing and Maintenance of Horizontal laminar flow cabinet or as directed by Engineer in charge. Notes :- Testing certificates need to be furnished by the contractor.
Supply and fix Rotational moulded water storage tank (cylinderical, vertical with closed top) hoisted and fixed in position with all connection such as in let,out let,air vent pipe overflow etc all as specified and directed of size 500 Ltr including disconnecting existing unserviceable water tanks.
Chaulya Enterprises
Maruti Abhiyantriki
D H L ENTERPRISES
Suchit constructions
MAHIMA CONSTRUCTION
Arihant Construction
Abhiraj Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .