| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC 193 E SHANTI PALLI PUSHPAHAR CO OPERATIVE KOLKATA 700107 | KOLKATA | WEST BENGAL | 700107 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹19.7 L+₹3.6 L (22.1%)Rejected-Finance 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L2 | Rejected-Finance OTHER THAN L1 BID | |
| 3 | L3₹19.8 L+₹3.7 L (22.6%)Rejected-Finance SADAR BAZAR PRINZE ROAD SAHANTOSHREE PALLY PHASE II P O P S BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700 120 WB | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L3 | Rejected-Finance OTHER THAN L1 BID | |
| 4 | L4₹22.1 L+₹6.0 L (37.3%)Rejected-Finance BHANGARMATH THAKURANI CHAWK PO SAMABYPALLY BALLY HOWRAH 711 205 WEST BENGAL | HOWRAH | WEST BENGAL | 711205 | L4 | Rejected-Finance OTHER THAN L1 BID |
Tender Value
₹18 L
EMD Value
₹38,000
Closing Date
19 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(I)(CGN)KOLKATA
DAMODAR COMPLEX GARDEN REACH ROAD KOLKATA 23
REPAIR AND MAINTENANCE TO EXTERNAL ELECTRIC SUPPLY AND ALLIED WORKS AT NAVY AREA (INS NETAJI SUBHAS, DAMODAR COMPLEX, TEESTA COMPLEX, DUMAYUNE AVENUE, MEGHNATH BLDG, BAGJOLA ETC.) UNDER GE(I)(CGN)KOLKATA
2022_MES_541317_3
8039/B/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE(I)(CGN)KOLKATA
as per tender document
11 documents required · 11 mandatory
₹500
GE (I) (CGN) KOLKATA
₹38,000
Yes
29 Dec 2022
31 Oct 2022
21 Nov 2022
31 Oct 2022
19 Nov 2022
5 Nov 2022
Amount
M&L for repair/replacement of defective/leaking HT bushings from the transformer of capacity 200 to 400 KVA by removing the transformer oil by top opening, replacement of HT bushings with new cover gaskets, refilling, and closing the transformer top cover complete including testing all as specified and as directed.
M&L for repair/replacement of defective/leaking LT bushings from the transformer of capacity 200 to 400 KVA by removing the transformer oil by top opening, replacement of HT bushings with new cover gaskets, refilling, and closing the transformer top cover complete including testing all as specified and as directed.
M&L for removing existing old paint by scraping from transformer , fins and conservator tank, and applying two coats of synthetic enamel paint (1st quality) by spraying including writing SM/MES No, any capacity in paint as specified by Engr-in-charge complete all as specified and directed.
Dehydration & filteration of transformer oil by disconnecting the device from supply and draining out the complete oil, filtering the dirt, sludge and dehumidifying by heating the same and raising the Breakdown voltage level 60 KV at 2.5 mm gap and testing and recording the result for three times in specified interval including pouring the oil in transformer tank and charging the same to restore supply complete all as specified and as directed.
Supply & filling only Transformer Oil for topping up the level( after necessry disconnection and earthing both winding) with grade as per IS : 335 complete incl opening the tank cover and refixing the same and charging the transformer to the supply voltage complete all as specified and as directed including taking out old one. Note : Die electric strength of the oil shall be ensured not less than 60 KV before filling. Make of Oil - Poweroil/ Gulf)
Maintenance of Vaccum circuit Breaker, make: PASCAL, 6.0 KV Grade, 200 to 630 Amps by licensed electrician including the following:- (a) Switiching off VCB and conforming that supply to incomming end is properly disconnecte. (b) Opening covers of the VCB and visual checking of epoxy housing and all parts for rust and wear. (c) Cleaning all parts of breaker compartment with appropriate chemical to remove dust and dirt and wipping of the envelop of the vacuum interrupeter and insulating material with a clean and dry cloths. (d) Lubricating of rotary sections and moving parts, sliding surfaces, pins, coupling section etc by applying a small amount of grease/ petrolium jelly/ machine oil as applicable. (e) Checking of PTs, CTs control circuits, closing and tripping coil and all other parts. (f) Replacement of detective or less reliable parts from OEM (to be measured and paid separately). (g) Cheaking auxilliary supply and control voltage, control circuits and tightening of all conections. Note : 1. After servicing of VCB, Health check up reports will be submitted.
Repair/ maintenance of HT Oil Isolating switch(VLE) unit of 200 Amps capacity, 3 phase manually operated fixed/draw out ID type oil isolating switch 11KV/200A, MEI make at Teesta building by removing the breaker from panel discmantling carefully its parts/accessories. Cleaning the dust/impurities and accumulations etc blowering/brushing cleaning properly with CRC-26 spray to remove rust including supply of gasket, oil seal, nut & bolts, washers, reassembles, the parts /accessories and fix in same position and connection, testing for satisfactory operation all as directed. (Note: Maintenance /repairs shall be carried out by trained technicians/mechanic (ii) All repairs shall be carried out at site only. Necessary testing,/measuring instrument shall be brought at site by the contractor at the time of work and all cost on this account should be included in the quoted rate)
Removing existing old paint by scraping from Vacuum Circuit Breaker/VLE and applying two coats of synthetic enamel paint (1st quality) by spraying including writing SM/MES No, capacity in white paint complete all as specified and directed.
Supply and replacement of heating coil of Vacuum Circuit Breaker including taking down old unserviceable all as specified as directed .
Supply and replacement of Potential transformer of Vacuum Circuit Breaker (Model and type as per sample) including taking down old unserviceable all as specified as directed .
Supply and replacement of current transformer of Vacuum Circuit Breaker (Model and type as per sample) including taking down old unserviceable all as specified as directed .
Supply and replacement of Power pack unit of Vacuum Circuit Breaker (Model and type as per sample) including taking down old unserviceable all as specified as directed .
Calibration of relays of Vacuum Circuit Breaker with secondry injection unit and check the healthiness of relays and adjust the realy settings as per ground requirements complete all as specified and as directed. Note: Report of calibration to be submitted to the department.
Supply and replacement of Vacuum interuppter for 630 Amp VCB (Model and type as per sample) all as specified and as directed. Make: ABB/Scheneider/L&T
Supply only electrical insulating mat type C conforming to IS 15652: 2006 for high tension appliance with standard width of 1.0 Mtr x 2.0 mtr length including taking down old unserviceable all as specified as directed. Note: Test report to be submitted to the department.
Supply only electrical insulating mat type A conforming to IS 15652: 2006 for low tension appliance with standard width of 1.0 Mtr and in customised length including taking down old unserviceable all as specified as directed Note: Test report to be submitted to the department.
Disconnecting, repair and maintenance of APFC panel and replacement of internal wiring by new, checking and taking out defective unserviceable parts and replaced the same to make serviceable connection, testing etc. as directed. Note: (i) Maintenance / repairs shall be carried out by trained technicians/mechanic under supervision of qualified electrical technician. (ii) All repairs shall be carried out at site only. (iii) Spare / parts shall be measured and paid seperately as ''supply only''
Supply only 5 to 15 KVAR capacitor, box series type-LTXL-Ultra heavy duty, 440V, including taking down old unserviceable all as specified as directed. Make- L&T/BCH/ABB
Supply only 20 to 50 KVAR capacitor, box series type-LTXL-Ultra heavy duty, 440V, including taking down old unserviceable all as specified as directed. Make- L&T/BCH/ABB
Supply only APFC Relay meter (8 Steps) complete including taking down old unserviceable all as specified as directed . Make- L&T Model No etaCON M or equivalent in BCH/ABB.
Supply only capacitor duty contractors of 5 KVAR rating, type MO C5, size Fr 1 including taking down old unserviceable all as specified as directed . Make: L&T/BCH/ABB.
Supply only capacitor duty contractors of 10 KVAR rating, type MO C10, size Fr 1 including taking down old unserviceable all as specified as directed . Make: L&T/BCH/ABB.
Supply only capacitor duty contractors of 20 KVAR rating, type MO C20, size Fr 1 including taking down old unserviceable all as specified as directed . Make: L&T/BCH/ABB.
Supply and fixing MCCB, 16-125 Amps, 4 pole, 36 KA breaking capacity 415 Volts with necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed. Make: L&T/BCH/ABB./Legrand.
Supply and fixing MCCB, 160 Amps, 4 pole, 36 KA breaking capacity 415 Volts with necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed. Make: L&T/BCH/ABB./Legrand.
Supply and fixing MCCB, 200 Amps, 4 pole, 36 KA breaking capacity 415 Volts with necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed. Make: L&T/BCH/ABB./Legrand.
M & L Cable jointing kit for 11 KV (Earthed) grade cable for straight though heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed. Make: Raychem/3M/Denson
M&L Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm sqmm cutting of old jointing material including taking down old one complete all as specified and as directed. Make: Raychem/3M/Denson
M & L Cable jointing kit for 1100 V grade cable for straight though (cold applied insulation and sealing system) heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185-300 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed. Make: Raychem/3M/Denson
M & L Cable jointing kit for 1100 V grade cable for straight through (cold applied insulation and sealing system) heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70-150 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed. Make: Raychem/3M/Denson
M & L Cable jointing kit for 1100 V grade cable for straight through (cold applied insulation and sealing system) heat shrink type joint complete with jointing material and accessories suitable for 3.5/4.0 core XLPE armoured aluminium conductor cable of size 25-50 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed. Make: Raychem/3M/Denson
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 16 Sqmm 4 coreincluding taking down old one complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 25 Sqmm 4.0 core including taking down old one complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS IS 7098 (Part- I)with aluminium conductor of cross sectional area 35 Sqmm 3.5 core including taking down old one complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 50 Sqmm 3.5 core including taking down old one complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 70 Sqmm 3.5 core including taking down old one complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 11000 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- II) with aluminium conductor of cross sectional area 50 Sqmm 3 core including taking down old one complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 11000 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- II) with aluminium conductor of cross sectional area 95 Sqmm 3 core including taking down old one complete all as specified and as directed.
Supply only , 1100 volts grade PVC insulated and FR PVC round sheathed, copper conductor (flexible) industrial cable of cross sectional area 10 Sqmm 4 core conforming to IS 694 with suitable size of lugs (02 sets) on a drum with handle with movable trolley (one for 100 RM length) complete all as specified and as directed.
Supply & fix hot dip galvanized steel perforated cable tray with tray cover rectanglar type (rigid & felxible) of suitable width ranging from 4 inch to 8 inch to be fixed on wall complete all specified and as directed.
M&L for painting of perforated cable tray and cover of width 4-8 inch with two coats of powder coated paint (1st quality) of approved colour by brush after removing all dust/rust all as specified and as directed.
Excavating in trenches n. exc. 1.5 m. wide and n. exc. 1.5 m. in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pire holes, etc. n. exc. 10 sqm on plan and not exc. 1.5 m. in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling including spreading levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed.
Removing excavated soil not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point in soil complete all as specified and as directed.
M&L for sand filling for cable cushioning including spreading and levelling as directed. Note : Thickness for sand shall be measured after punning down.
M & L Bricks, common burnt clay building bricks, old size sub-class ‘B’ designation 75 laid perpendicular to the axis of cable,abutting 10 mm gap in between complete all as specified and directed.
M&L for laying old brick perpendicular to the axis of cable,abutting 10 mm gap in between complete all as specified and directed.
Supplying and laying reinforced precast concrete cable cover class HV, Type 1, flat, size 300mmx 180mm x 40mm all as specified and as directed.
S&F PVC single channel wire protection cable protection cover suitable for armoured cable size up to 95 sqmm to be able to laid temporarily/permanentaly on the road and able to bear load of heavy vehicle all as specified and as directed. Make: Hensel or equivalent make approved by GE.
M & L Tubes, 'light grade', galvanised,with all fitting,laid in trenches/fixed on Wall 40 mm dia for protection of cable all as specified and directed.
M & L Tubes, 'light grade', galvanised,with all fitting,laid in trenches/fixed on Wall 50 mm dia for protection of cable all as specified and directed.
M & L Tubes, 'light grade', galvanised,with all fitting,laid in trenches/fixed on Wall 80 mm dia for protection of cable all as specified and directed.
M&L for road cutting for laying of LT UG cable /Galvanised Iron Pipe complete all as specified and directed.
M&L plain cement concrete 1:3:6 Type C1 (using 20 mm graded crushed stone aggregate) as in coping, roof kerb or similar work, rounded or chamfered on edges including necessary form work including demolition old one complete all as specified and directed.
Earthing complete with GI earth plate electrode of size 60 x 60 x 0.6 cms burried directly in ground vertically at a depth of not less than 2.25 Mtrs below normal ground level with top edge of the earth plate at a depth not less than 1.5 Mtr below normal ground level surrounded from all sides by 15 cms thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI earth strip 25 x 4 mm size upto 7.5 mtr by means of bolts, nuts, checknuts and washers made out of galvanised iron and protected by medium grade 50 mm dia 5 mtr long and connected to main control panel and GI pipe 20 mm medium grade as watering pipe including funnel, wire mesh, PCC Pit made up of PCC 1:2:4 type C2 and RCC cover 40 mm thick with 8 mm bar 15 c/c including excavation and earth work all as specified in SSR Part 1 2009.
M & L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4 mm galvanised iron strip complete incl saddles if required.
M & L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20x3 mm copper strip complete incl saddles if required.
M&L for PCC Pit for earthing made up of PCC 1:2:4 type C2 and RCC cover 40 mm thick with 8 mm bar 15 c/c including water pipe with funnel and wire mesh and also includes excavation and earth work all as specified in SSR Part 1 2009.
M&L Aluminium strip 25 x 3.15 mm with porcelein insulators , saddles and fixing screws etc. for roof conductors and down conductors including taking down old one complete all as specified and as directed.
Refixing of hanging/loosen earth strip/roof conductors of Cu/GI/Al with replacement of broken procelain connector and proper clamping, saddling and connected accessories at the original location complete all as directed. Note: Price of porcelain connector deemed inclusive of quoted rate.
Refixing of hanging/loosen earth strip/down conductors of Cu/GI/Al with replacement of broken procelain connector and proper clamping, saddling and connected accessories at the original location complete all as directed. Note: Price of porcelain connector any scaffloding required deemed inclusive of quoted rate.
Supply & fix Air termination single pointed aluminum rod 12 mm dia and 300 mm long including taking down old unserviceable one complete all as specified and as directed.
Supply & fix Test point terminal block made of gunmetal or phosphorus bronze of size 75 x 75 x 25 mm, drilled and screwed including 3 nos 8 mm dia 25 mm long hex head screw complete all as specified and as directed including taking down old unserviceable one.
M&L for outdoor LT Panel cubicle compartmentalized type panel of suitable size with 3.15 mm thick CRCA sheet with 2.0 mm thick gland plate suitable for IP 52 protection, phosphate powder coated in Siemens grey colour with suitable size of Al Bus bar with heat colour coded sleeve with provision of cable entry from bottom & top, supported on MS angle of size 40 x 40 x 6 mm complete with all fittings and fixing arrangement all as specified and as directed with following specifications:- Note: 1. Switchgears and metering equipment will be provided by department. 2. Busbars and internal wiring and connector deemed inclusive of the quoted rate. 3. Any minor spares deemed inclusive of the quoted rate. 4. PCC for foundation deemed inclusive of the rate.
M&L for indoor LT Panel cubicle compartmentalized type panel of suitable size with 1.6 mm thick CRCA sheet with 2.0 mm thick gland plate suitable for IP 52 protection, phosphate powder coated in Siemens grey colour with suitable size of Al Bus bar with heat colour coded sleeve with provision of cable entry from bottom & top complete with all fittings and fixing arrangement all as specified and as directed with following specifications:- Note: 1. Switchgears and metering equipment will be provided by department. 2. Busbars and internal wiring and connector deemed inclusive of the quoted rate. 3. Any minor spares deemed inclusive of the quoted rate. 4. PCC for foundation deemed inclusive of the rate.
S &F Indicator LED phase lamps 03 Nos (R, Y, B) including taking down old one complete all as specified and as directed.
S & F Volt meter 0-500 Volts Digital Type including taking down old one complete all as specified and as directed.
S & F Ammeter 0-500 Amps Digital Type including taking down old one complete all as specified and as directed.
M&L for painting of LT panels, APFC pannel, feeder pillar boxes, junction boxes, sheet metal enclosure and any other steel surfaces complete with two coats of powder coated paint (1st quality) of approved colour by spraying after removing all dust/rust /grease including preparation surface all as specified and directed.
M&L for shifting of LT panel from one location to another by disconnecting and/or terminating old connection, removing foundation PCC and fixing at new location if required all as specified and as directed. Note: 1. Transportation cost deemed inclusive of the quoted rate. 2. PCC for foundation shall be measured and paid separately.
Supply and fix electronic driver for LED flood light/street light as per existing capacity including fitting arrangements and taking down old one complete all as specified and as direted.
Supply and fix electronic driver for LED bollard light/post top lantern/spot light as per existing capacity including fitting arrangements and taking down old one complete all as specified and as direted.
Supply and fix flood LED light in 50 W in static mono colour (colour as specified by Engr-In-Charge) with IP 66 protection with all fittings and accesories complete all as specified and as directed. Make: Havells Model No Jeta Quanto Plus or equivalent in Philips/Bajaj
Supply and fix flood LED light in 200 W in static mono colour or as specified by Engr-In-Charge with IP 66 protection with all fittings and accesories complete all as specified and as directed.
Supply and fix LED Post top lantern in 40 W in warm white colour with IP 65 protection with all fittings complete all as specified and as directed. Make: Jaquar Model Navis or equivalent in Havells/Surya/Philips
Supply and fix LED flood light in 350 W IP 65 protection with all fittings complete all as specified and as directed. Make: Havells/Surya/Philips
S&F machine history sheet / chart with details on acrylic sandwich sheet board for display with size 450 mm x 600 mm with 4 mm thickness as directed including taking down old one complete with suitable fixing arrangement all as specified and as directed . Note: Subject material to be provided by the department.
S&F Electric Shock treatment chart in three language (Hindi, english and Bangla) with details on acrylic sandwich sheet board for display with size 450 mm x 600 mm with 4 mm thickness as directed including taking down old one complete with suitable fixing arrangement all as specified and as directed .
S&F Sign Board with details made of acrylic sheet board waterproof for display with 2.5 ft height x 6 ft width with 12 mm thickness fixed with SS clamp complete all as specified and as directed. Note: Subject material to be provided by the department.
S & F water supply/electric supply/fire fighting network diagram chart acrylic PVC sheet with size 5 ft x 3ft with 4 mm thickness complete all as specified and directed by engr-in-charge.
Supply and fix sheet steel enclosure 4 way TPN DB with 200 amps bus bar with provision for TPN MCB as incomer, double door type complete all as specified and directed. Make: Legrand/ABB/L&T/Siemens/Schenieider.
Supply and fix MCB TPN 240V, 16-32 Amps capacity 'C' Curve complete all as specified and directed. Make: Legrand/ABB/L&T/Siemens/Schenieider.
Supply and fix MCB TPN 240V, 40-100 Amps capacity 'C' Curve complete all as specified and directed. Make: Legrand/ABB/L&T/Siemens/Schenieider.
Supply only portable test kit for energy meter made up of wooden board with suitable thickness fixed with 1 Ph engery meter (5-40 Amp)-01 No (Make- L&T/HPL), MCB DP 40 Amp-01 No (Make-L&T/Legrand/ABB), 1 KW Halogen light-01 No, with connected wiring and provision for parellel load connection for checking of energy meter with necessary accessories all as specified and as directed.
Supply only portable test kit for energy meter made up of wooden board with suitable thickness fixed with 3 Ph engery meter (10-60 Amp)-01 No (Make- L&T/HPL), MCB TPN 60 Amp-01 No (Make-L&T/Legrand/ABB), 1 KW Halogen light-01 No with connected wiring and provision for parellel load connection for checking of energy meter with necessary accessories all as specified and as directed.
Supply only Aluminium cable lugs (each set of four) suitable for XLPE armourded cable for cable size of 16-300 sqmm with 3.5/4.0 core all as specified and as directed.
Supply only Aluminium ferrules (each set of four) suitable for XLPE armourded cable for cable size of 16-300 sqmm with 3.5/4.0 core all as specified and as directed.
Supply only plain rubber HT safety gloves suitable for 11KV supply protection, reusable type (in pair) of suitable size all as specified and as directed.
Supply and fix SMC junction box fix to wall/pole , Size - 300 x 200 mm, with provision of cable incoming and outging including cable glands and 4 Pole PVC Connector all fittings including taking down old unserviceable one all as specified and as directed. Make- Sintex/Hensel/RMW
MS AP CONSTRUTION AND CO
ONIEL SALES
dutta and dutta
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .