| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAdmitted-Finance | ₹30.8 L | L1 | Admitted-Finance |
| 2 | L2₹33.0 L+₹2.1 L (6.95%)Admitted-Finance | ₹33.0 L+₹2.1 L (6.95%) | L2 | Admitted-Finance |
| 3 | L3₹33.0 L+₹2.1 L (6.96%)Admitted-Finance | ₹33.0 L+₹2.1 L (6.96%) | L3 | Admitted-Finance |
| 4 | L4₹33.6 L+₹2.8 L (9.14%)Admitted-Finance | ₹33.6 L+₹2.8 L (9.14%) | L4 | Admitted-Finance |
| 5 | L5₹33.7 L+₹2.9 L (9.43%)Admitted-Finance 28A RAGHAVPURAM OPPOSITE PRAGATI VIDHYA PEETH SCHOOL SLP COLLEGE ROAD CP COLONY MORAR GWALIOR 474006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | ₹33.7 L+₹2.9 L (9.43%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | S K MECHANICAL WORKS L3 | keerti enterprises L1 | BHAGIRATH CONSTRUCTION COMPANY L5 | RADHA TELECOM NETWORK L8 | ISLAM AND BROTHERS L2 | M/S Bharat Engineering L4 | BEHL CONSTRUCTION CO L6 | M/s Shanti Enterprises L9 | M/s raj construction L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down old submain wiring of any size any type complete all as specified and directed. | 1,100 | RM | 12 ₹13,200 | 2 ₹2,200 Lowest | 2 ₹2,200 Lowest | 10 ₹11,000 | 5 ₹5,500 | 5 ₹5,500 | 10 ₹11,000 | 5 ₹5,500 | 2 ₹2,200 Lowest |
| 2.00 | Taking down old TPN/VTPN/Meter Distribution Box with MCB's of any make/capacity complete all as specified and directed. | 30 | Each | 19 ₹570 | 55 ₹1,650 | 5 ₹150 | 10 ₹300 | 5 ₹150 | 5 ₹150 | 15 ₹450 | 5 ₹150 | 2 ₹60 Lowest |
| 3.00 | Taking down old MCB Enclosure & MCB DB SPN any make/capacity complete all as specified and directed. | 80 | Each | 11 ₹880 | 10 ₹800 | 5 ₹400 | 10 ₹800 | 5 ₹400 | 5 ₹400 | 10 ₹800 | 5 ₹400 | 2 ₹160 Lowest |
| 4.00 | Taking down old MCB SPN/SP of any make/capacity complete all as specified and directed. | 770 | Each | 14 ₹10,780 | 20 ₹15,400 | 2 ₹1,540 Lowest | 10 ₹7,700 | 5 ₹3,850 | 5 ₹3,850 | 10 ₹7,700 | 5 ₹3,850 | 2 ₹1,540 Lowest |
| 5.00 | S&F in renewal sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and including non metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed.
NOTE: (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface. | 400 | RM | 172 ₹68,800 | 250 ₹1,00,000 | 190 ₹76,000 | 150 ₹60,000 | 130 ₹52,000 Lowest | 180 ₹72,000 | 300 ₹1,20,000 | 400 ₹1,60,000 | 300 ₹1,20,000 |
| 6.00 | S&F in renewal sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 4 sqmm size drawn in and including non metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 4 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed.
NOTE: (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface. | 700 | RM | 154 ₹1,07,800 | 220 ₹1,54,000 | 160 ₹1,12,000 | 111 ₹77,700 | 100 ₹70,000 Lowest | 150 ₹1,05,000 | 285 ₹1,99,500 | 320 ₹2,24,000 | 250 ₹1,75,000 |
| 7.00 | S&F in renewal distribution meter box indoor type, factory made out of CRCA sheet 2mm thick complete with inside, outside powder coated independed housing for meters with transperent glass & rubber gasket packing with suitable size copper single/ two core wire for each control, cable gland, with 200 Amp rated TPN aluminium busbar duly insulated (including self insulated) maintaining proper space for each busbar and grouting panel in wall etc complete including comprising complete all as specified and directed for following fittings (i) MCCB 4 pole, 100 Amps - 01 No (For incoming) (ii) Amp Meter (0-100 Amp)- 01 Nos (iii) Volts Meter (0-500 Volts ) - 01 No (iv) Indicator Lamp set of three R,Y,B - 01 Set (v) ASS & VSS with CTs -02 Nos ( 01 Each) (vi) MCB SP 63 Amps - 04/06 Nos as per location(For outgoing) and MCB SP 20 Amps - 01 Nos (For bldg light) (vii) Nutral bus bar link mounted on insulator (viii) Refix thre energy meter as per previous location as space in distribution box- 04/06 Nos as per location, Connection MCCB to MCB to Energy Meter than QTR DB
Note;- (i) Cable entry gland made of polycarbonate of appropriated size shall be provided in each cable / wire entry as per IS standered. (ii) All internal wiring inside the panel used for metring purpose shall be PVC insulated FRLSH, ISI marked of size not less than 1.5 Sqmm. | 20 | Each | 15,245 ₹3,04,900 | 15,000 ₹3,00,000 | 26,000 ₹5,20,000 | 35,000 ₹7,00,000 | 25,000 ₹5,00,000 | 20,000 ₹4,00,000 | 7,500 ₹1,50,000 Lowest | 11,000 ₹2,20,000 | 30,000 ₹6,00,000 |
| 8.00 | S&F in renewal sheet metal enclosure double door for distribution board factory made for MCB DB load link VTPN 4 way suitable for MCCB as incomer, 100 Amp,4 pole & Including MCCB 100 amps 4 pole 16 KA complete. (when MCB's are to be used) with suitable size of busbar complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed. | 30 | Each | 7,795 ₹2,33,850 | 11,000 ₹3,30,000 | 11,000 ₹3,30,000 | 9,400 ₹2,82,000 | 9,500 ₹2,85,000 | 12,500 ₹3,75,000 | 7,200 ₹2,16,000 Lowest | 8,500 ₹2,55,000 | 9,500 ₹2,85,000 |
| 9.00 | S&F for MCB SP 63 Amps,240 volts, 'C' series 10 KA including connection with suitable size copper lugs complete all as specified and directed. | 180 | Each | 372 ₹66,960 | 280 ₹50,400 | 140 ₹25,200 | 250 ₹45,000 | 200 ₹36,000 | 350 ₹63,000 | 380 ₹68,400 | 300 ₹54,000 | 120 ₹21,600 Lowest |
| 10.00 | S&F in renewal sheet metal box Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amp complete all as specified and directed. | 30 | Each | 1,488 ₹44,640 | 800 ₹24,000 | 750 ₹22,500 | 550 ₹16,500 | 500 ₹15,000 Lowest | 900 ₹27,000 | 800 ₹24,000 | 550 ₹16,500 | 750 ₹22,500 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
17 Aug 2026, 6:00 pmClosed
Garrison Engineer Gwalior
Garrison Engineer Morar Cantt Gwalior
REPAIR/MAINT OF MCB DB AND MISC ITEM UNDER GE GWALIOR
2026_MES_780145_1
8395/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer Gwaliior
Please ref tender documents
9 documents required · 9 mandatory
₹500
Garrsion Engineer Gwalior
₹84,000
Yes
25 Aug 2026
22 Jul 2026
19 Aug 2026
22 Jul 2026
17 Aug 2026
5 Aug 2026
23 Jul 2026 - 28 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down old submain wiring of any size any type complete all as specified and directed. | 1,100 | RM | 1 | ₹1,100 |
| 2 | Taking down old TPN/VTPN/Meter Distribution Box with MCB's of any make/capacity complete all as specified and directed. | 30 | Each | 2 | ₹60 |
| 3 | Taking down old MCB Enclosure & MCB DB SPN any make/capacity complete all as specified and directed. | 80 | Each | 3 | ₹240 |
| 4 | Taking down old MCB SPN/SP of any make/capacity complete all as specified and directed. | 770 | Each | 4 | ₹3,080 |
| 5 | S&F in renewal sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and including non metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed.
NOTE: (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface. | 400 | RM | 5 | ₹2,000 |
| 6 | S&F in renewal sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 4 sqmm size drawn in and including non metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 4 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed.
NOTE: (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface. | 700 | RM | 6 | ₹4,200 |
| 7 | S&F in renewal distribution meter box indoor type, factory made out of CRCA sheet 2mm thick complete with inside, outside powder coated independed housing for meters with transperent glass & rubber gasket packing with suitable size copper single/ two core wire for each control, cable gland, with 200 Amp rated TPN aluminium busbar duly insulated (including self insulated) maintaining proper space for each busbar and grouting panel in wall etc complete including comprising complete all as specified and directed for following fittings (i) MCCB 4 pole, 100 Amps - 01 No (For incoming) (ii) Amp Meter (0-100 Amp)- 01 Nos (iii) Volts Meter (0-500 Volts ) - 01 No (iv) Indicator Lamp set of three R,Y,B - 01 Set (v) ASS & VSS with CTs -02 Nos ( 01 Each) (vi) MCB SP 63 Amps - 04/06 Nos as per location(For outgoing) and MCB SP 20 Amps - 01 Nos (For bldg light) (vii) Nutral bus bar link mounted on insulator (viii) Refix thre energy meter as per previous location as space in distribution box- 04/06 Nos as per location, Connection MCCB to MCB to Energy Meter than QTR DB
Note;- (i) Cable entry gland made of polycarbonate of appropriated size shall be provided in each cable / wire entry as per IS standered. (ii) All internal wiring inside the panel used for metring purpose shall be PVC insulated FRLSH, ISI marked of size not less than 1.5 Sqmm. | 20 | Each | 7 | ₹140 |
| 8 | S&F in renewal sheet metal enclosure double door for distribution board factory made for MCB DB load link VTPN 4 way suitable for MCCB as incomer, 100 Amp,4 pole & Including MCCB 100 amps 4 pole 16 KA complete. (when MCB's are to be used) with suitable size of busbar complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed. | 30 | Each | 9 | ₹270 |
| 9 | S&F for MCB SP 63 Amps,240 volts, 'C' series 10 KA including connection with suitable size copper lugs complete all as specified and directed. | 180 | Each | 10 | ₹1,800 |
| 10 | S&F in renewal sheet metal box Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amp complete all as specified and directed. | 30 | Each | 11 | ₹330 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
BOQ_873867.xls
BOQ • 0.39 MB
8395Tenderdocuments.pdf
Tender Documents • 1.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .