| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 CrAccepted-AOC | ₹40.4 Cr Quoted ₹42.3 Cr | L1 | Accepted-AOC Ist lowest Accept |
| 2 | L2₹42.7 CrRejected-Finance | ₹42.7 Cr | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical DURGA APT INDRA NAGAR NASHIK 422009 | NASHIK | NASHIK | MAHARASHTRA | 422009 | - | - | Rejected-Technical Disqualified due to sr.no 17,43,44,45,46 are not clear |
| 4 | Rejected-Technical N A | FARIDABAD | HARYANA | 121004 | - | - | Rejected-Technical Disqualied due to sr no .17 and 46 are not clear |
| 5 | Rejected-Technical OFFICE NO 515 PLOT NO 194 NMS ICON SECTOR 19 ULWE NAVI MUMBAI MAHARASHTRA 410206 | NAVI MUMBAI | THANE | MAHARASHTRA | 410206 | - | - | Rejected-Technical Disqualied due to sr no .23,43 and 46 are not clear |
Tender Value
₹38.4 Cr
EMD Value
₹19.2 L
Closing Date
28 Aug 2023, 6:00 pmClosed
Executive Engr.P.W.Division A.nagar
Executive Engr. P.W.Division A.nagar
Construction of Mahasul Bhavan Building at Ahmednagar,Tal. and Dist. Ahmednagar
2023_PWR_931242_1
E-Tender Notice No.22 for 2023-24
Open Tender
Civil Works
730 days
Ahmednagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹3,540
₹19.2 L
Chief Engineer.P.W.Region Office, Bandhkam Bhavan,
9 Jan 2024
2 Aug 2023
29 Aug 2023
2 Aug 2023
28 Aug 2023
2 Aug 2023
17 Aug 2023
Amount
Excavation for foundation in earth, soil of all types, sand, gravel and soft murumetre, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramilimetre ing, watering including shoring and strutting etcetera complete. (Lift upto 1.5 metre ) By Mechanical Means
Excavation for foundation in earth, soils of all types, sand,gravel and soft murumetre, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramilimetre ing, watering including shoring and strutting etcetera complete. (Lift from 1.5m to 3.0m) By Mechanical Means
Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramilimetre ing, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0metre ) By Mechanical Means
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murumetre, ramilimetre ing ,watering including shoring and strutting etcetera complete. (Lift from 1.5m To 3.0 metre ) By Mechanical Means
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimilimetre ing and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramilimetre ing etcetera complete. (Lift upto 1.5 m). By Mechanical Means
Filling in plinth and floors with approved excavated material in 15centimetre to 20centimetre Layers including watering and compacting etcetera complete.
Filling in plinth and floors with contractors material/brougHight from outside and approved by Engineer incharge in layers of 15 centimetre to 20 centimetre including watering and compaction etcetera complete.
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etcetera complete.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten years guarantee on bond paper.
Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap / granite/quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinfoReinforced Cement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap / granite/quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinfoReinforced Cement and structural steel).with fully automatic micro processor based PLC without SCAD Aenabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
First Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including steel centering, formwork,cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinfoReinforced Cement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade) Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and laying Cast in situ/Ready Mixcement concrete M-35 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etcetera complete. (Excluding reinfoReinforced Cement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
First Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etcetera complete. (Excluding reinfoReinforced Cement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade) Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinfoReinforced Cement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
First Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinfoReinforced Cement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade) Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinfoReinforced Cement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinfoReinforced Cement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.metre 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etcetera complete. (Excluding einfoReinforced Cement , including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing in position Thermo Mechanically Treated Steel - FE - 500 bar reinfoReinforced Cement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size ( 625x240x225)milimetre in extra fine jointing mortar of fixoblock of in foundaions and plinth of inner walls/in plinth external walls including bailing out water,striking joints on unexposed faces,racking out joints on exposed faces and watering etc.complete
Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size ( 625x240x225)milimetre in extra fine jointing mortar of fixoblock of in superstucture including,striking joints,racking out joints watering and scaffolding etc.complete
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and constructing masonry in Autoclaved Areaclaved (Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size (625x 240x100)milimetre in extra fine jointing mortar of fixoblock of in half brick thick wall including 2 hoop iron strips 25milimetre x 1.6milimetre at every third course,properly bend and bonded at ends scaffolding racking out joints and watering compete
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing internal cement plaster 12milimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6milimetre thickness or Tape Grooves 35 to 45 milimetre thickness or as required, in all position including preparing the surface, scaffolding etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and applying gypsum plaster ( with Gypsum material ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing during laying in Reinforced Cement Concrete Slab rectangular 2 milimetre thick metre S. sheet fan hook box of size 180x100 milimetre with required depth with holes or notches as required, bottom and top sides of 1.6 milimetre metre S. sheet fixed with 3.5 milimetre diamatre round headed screws together with 12 milimetre diamatre metre S. bar bent to shape with hooked ends for fan hook and painting to exposed surface
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and Fixing Galvanised Iron Elevation Fins having Sertain 75mm with blank powder coating in finish and fitting with 50 milimetre X 50milimetre X 2.90 milimetre Mild Steel Box framing in required grid size including all necessary fixtured fastener,transportaion, scaffolding the template etcetera complete. First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing of expose cladding godhara bricks etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.metre 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.metre 1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300milimetre x 300 milimetre making the junctions at the parapet rounded and tapered top for required heigHight, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etcetera complete.Fifth Floor
Providing water proof bedding for flooring of Bath and Water Closet 25 milimetre thick in C.metre 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing waterproof plaster in Water Closet and bath 12 milimetre thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogrametre per bag of cement of approved make and manufacturer and curing etcetera complete. (Excluding Tiles) (As directed by Engineer in Charge)
First Floor
Second Floor
Third Floor
Fourth Floor
Providing waterproofing in Water Closet and bath including brick bat coba in all position including providing and laying 12milimetre bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness incentimetre 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20milimetre thick brick bedding incentimetre mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and laying ceramic tiles having size 30 centimetre x 60 centimetre confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimetre x 30centimetre and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and laying vitrified matt fininsh tiles having size 590 milimetre to 605 milimetre x to 605 milimetre of 8 to 10 milimetre thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and laying vitrified stone effect finish tiles having size 590 to 605 milimetre x 590 to 605 milimetre of 8 to 10 milimetre thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including required position laid on a bed of 1:4 cement mortarincluding neat cement float, filling joints, curign and cleaning etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to IS 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc .complete. First Floor
Second Floor
Third Floor
Fourth Floor
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre x 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and laying vitrified mirror / glossy finish tiles having size 590 milimetre to 605 milimetre x 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.metre 1:3 curing and cleaning etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing machine cut mirror polished 18 milimetre to 20 milimetre thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 milimetre x 450 milimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 milimetre thick supports with kadappah top 35 to 40 milimetre thick and polished granite 16 to 20 milimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre heigHight and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etcetera complete. (Platform top size 5.00 metre x 0.60 m and heigHight is 0.75 m) First Floor
Second Floor
Third Floor
Fourth Floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 milimetre thick for door frame/ dado/ window boxing etc. On C.metre 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinfoReinforced Cement of 2 bars of 6 milimetre diameter / 2 hoop iron strips 25 milimetre X 1.6 milimetre placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etcetera complete.
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300milimetre x 40milimetre x 5milimetre with oil painting, etc. complete
Providing and fixing Country cut teak wood double or single leaf second class fully panelled door shutter with 35milimetre thick style and rail with 25 milimetre thick panels with openable fan ligHight as per detailed drawings. Excluding the door frame 60milimetre x 100milimetre stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats. (Excluding the door frame)
Providing and fixing Country cut teak wood single leaf panelled door shutter without fanligHight and 25milimetre thick as per drawing consisting of T.W. top rail size 100milimetre x 25milimetre and bottom lock rail 200milimetre x 25milimetre insert pannel 12 milimetre thick comilimetre ercial ply faced T.W. particle board with phenol formaldehyde synthetic resin (Generally confirming to ISI 3097) excluding frame, including stainless steel fixture and fastening and T.W. beading to junctions of panelled inserts and as instructed by the Engineer in charge including 3 coats of oil painting etcetera complete.
Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 milimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrougHight iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing 30milimetre thick Polyvinyl Chloride FLUSH L DOOR SHUTTER consisting of panel of hollow Polyvinyl Chloride profile of 20 milimetre thickness consisting frame made out of metre S. tubes of 19 gauge thickness and size of 19milimetre x 19milimetre inserted inside the hollow section of stiles rails top ?and bottom rails and two 19x 19 milimetre MS tubes inserted horizontally inside the hollow profile section using 4/5 milimetre sheet using screws hollow profile shall be lipped with 10 milimetre (5milimetre x2) thick x 20 milimetre width on stiles and rails using solvent cement. The inner panel shall be laminated with 5milimetre thick termite proof waterproof plain /prelam Polyvinyl Chloride sheet using solvent cement on the both sides of the panel including stainless steel fixtures and fastening etc. Complete as per direction of Engineer incharge, manufacturers specification and drawing.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 milimetre at weigHight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 milimetre at weigHight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 milimetre at weigHight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weigHight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 milimetre at weigHight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 milimetre at weigHight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising without box
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 milimetre x 1.22 milimetre box type, 5 milimetre thick sheet glass louvers, of approved quality etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Kitchen Trolley Providing and Fixing stainless steel kitchen trolley of overall 26 " heigHight and 22" depth,supported on aluminium pipes ,trolley basket made out of 5 milimetre stainless steel rod fitted on telescopic channel of size 1.5 " x 20 " x 22 " on both sides of trolley of 12 " or above size, panel having 40Kilogramload bearing capacity of trolley made out of 20 milimetre PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 milimetre s.s. decorative handle.(The width and heigHight of individual compartments shall be kept as directed by Engineer-in-charge) First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing Mild Steel grill door 24 Kilogram/ One Square Metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etcetera complete. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing High Dencity Polyethylene container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of a Cement Concrete essories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litresFifth Floor
Providing and fixing on walls/ ceiling/ floor 15 milimetre diamatre Chlorinated Polyvinyl Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing on walls/ceiling/floor 20 milimetre diamatre Chlorinated Polyvinyl Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing on walls/ ceiling/ floor 25 milimetre diamatre Chlorinated Polyvinyl Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing on walls/ ceiling/ floor 32 milimetre diamatre Chlorinated Polyvinyl Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing on walls /ceiling/ floor 40 milimetre diamatre Chlorinated Polyvinyl Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete. Fifth Floor
Providing and fixing on walls/ ceiling/ floor 50 milimetre diamatre CPolyvinyl Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing on walls/ ceiling/ floor 15 milimetre diamatre Unplasticized Polyvinyl Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing on walls/ceiling/floor 20 milimetre diamatre Unplasticized Polyvinyl Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing on walls/ ceiling/ floor 25 milimetre diamatre Unplasticized Polyvinyl Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing on walls/ ceiling/ floor 32 milimetre diamatre Unplasticized Polyvinyl Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing on walls /ceiling/ floor 40 milimetre diamatre Unplasticized Polyvinyl Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete. Fifth Floor
Providing and fixing on walls/ ceiling/ floor 50 milimetre diamatre Unplasticized Polyvinyl Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing Polyvinyl chloride Rain water pipes of 110milimetre outer diameter and having wall thickness of 2.2 to 2.7 milimetre confirming to I.S. 13592-1992 including proper rainwater receiving recess with Polyvinyl chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25milimetre to 40milimetre from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Polyvinyl chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32milimetre size of approved make including soil pipe, vent pipe up to outside face of wall ,100milimetre diametre matre G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etcetera complete. First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing 1st class white glazed earthenware Orissa Type Water Closet Pan 580 milimetre diametre including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 milimetre thick, 10 liter Polyvinyl chloride flushing cistern with all necessary pipe connection etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing white glazed earthenware Wash Hand Basin of 63cm x 45cm size including Bib cock stop tap brass heavy 15milimetre, brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including Polyvinyl chloride waste pipe and trap up to the outside face of the wall.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing wall-hung white wash basin of size 470x575x190milimetre of approved make half pedestal, pillar cock, Chrome PlatedAngular stop cock, long thread continental including S.S. bottle trap of having necessary pipe connections up to the outside face of the wall.etcetera complete. First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing White Glazed Earthenware full stall type Urinal with Polyvinyl chloride flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 milimetre diamatre Polyvinyl chloride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing 10centimetre Polyvinyl Chloride nahani trap with grating etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing Chrome Plated Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing Chrome Plated wall mixer with provision for overhead shower with 115milimetre long bend pipe and wall flange of approved make including necessary sockets/union nut etcetera complete. First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing Chrome Plated BIB cock with wall flange of approved make including necessary sockets/ union nut etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing Chrome Plated sink cock with raised J" shaped swinging casted spout ofapproved make including necessary sockets/ union nut etcetera complete." First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing 450milimetre x 550milimetre size superior type Belgium mirror with 16milimetre diametre matre nickel plated towel rod etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing chromium plated towel rod 16 milimetre diametre and 75 centimetre in length including all aCement Concrete essories complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial ligHight. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recomilimetre ended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist.
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and applying two coats of lead/zinc base oil paint/ bituminous paint of approved colour and shade to new wood work and fiber boards including preparing the surface, knotting, scaffolding if necessary, excluding primer coat etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and applying two coats of lead/zinc base oil paint/ bituminious paint of approved colour to new structural steel work and iron work in buildings including scaffolding if necessary, cleaning and preparing the surface etc. complete. (excluding primer coat).
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 milimetre diamatre and vertical pipe of 38 milimetre diametre at 0.60 m c/c or as required and horizontal pipes of 25 milimetre diametre in three rows, all pipes of 2 milimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 milimetre diametre above newel post of 75 milimetre diametre meter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use)
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Providing and fixing 900milimetre high S.S.304 Grade Stainless steel railing with 40milimetre diameter and 1.5milimetre thick at top, 40milimetre diameter and 1.5milimetre thick vertical supports spaced at 1.5m center to center and 8milimetre thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete. First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing 100milimetre diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangements and lock. [Without chamber].
Providing and fixing 15centimetre x 10 centimetre salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement Concrete Cover medium duty 140Kilogramwith frame etcetera complete.
Providing and constructing Brick Masonry inspection Chamber 90centimetre x 45cm including 1:4:8 C.C foundation, 1:2:4 Cement Concrete channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, with C.I. lead cover of 75Kilogramwith frame fixed in cement concrete.
Providing and laying machine cut machine Polished Kota stone flooring 25milimetre to 30milimetre thick and required width in plain/ diamond pattern on bed of 1:6 C. metre including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etcetera complete.
Fifth Floor
Supply and Installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel systemetre The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete systemetre Co-extruded UV protected polycarbonate panel system of min 12 milimetre thick of 900 milimetre (min.) width with angular dayligHighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility & strength. Panels with all fixing aCement Concrete essories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 One Numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge. Colour: As per Approval. Approved Make: FLUX by DPI DayligHighting or approved equivalent The 12milimetre thick panels shall be used for a roofing heigHight of upto 15 mtrs.
Fifth Floor
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Vibratory roller. to the required density. By Mechanical Means - Grading I (Using Screening Type A (13.2) milimetre Aggregate)
Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 80 milimetre thickness of having a strength of 300 Kilogram/Sq.centimetre of approved quality and shape on a bed of crushed sand of 25 to 30 milimetre thick including skirting joints and cleaning etc. complete
Providing and laying in situ cement concrete M30 with tremix treatment for 200 milimetre thickness for flooring with groove cutting of 4milimetre wide and 20milimetre deep with necessary refilling with bitumen etcetera complete.
Conveying materials obtained from road cutting including all lifts, laying in layers of 20centimetre to 30centimetre breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97% of standard proctor density for a lead of 300metre to 500metre inclusive, from the site of excavation to the site of deposition as directed.
Providing and laying concrete pipes of I.S.NP. class of 300milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450milimetre diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etcetera complete.
Providing and fixing 90 centimetre x 60 centimetre Granite plate engraving 10 centimetre HeigHight letter, figures including painting the lefters/figures with approved colour and shade complete
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 milimetre thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 milimetre is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both aCement Concrete ording to IRC 35:2015 clause 15.5. The finished surface to be level, uniformetre, and free from streaks and holes complete as per direction of Engineer-in-charge and in aCement Concrete ordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).
Providing and Laying of Rumble strips with Plastirib 2K, or equivalent 2 component cold plastic profiled material to give total width of 500 milimetre and heigHight of 10 milimetre Ramp provided to give width of 145 milimetre, width of ribs to be 55milimetre laid at centre to centre distance of 35 milimetre, with reflective glass beads @ 350 gm / One Square Metre. The finished surface to be levelled, uniform and free from streaks and holes, to be applied on the edge lines, including surface cleaning and cost of all materials etcetera complete.
Boring/drilling bore well of 300milimetre diametre for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machinery required for the job, all complete as per direction of Engineer in charge, upto 90m depth below ground level.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized Polyvinyl Chloride medium well-casing pipe of 150milimetre diametre conforming to IS:12818, including required hire and labour charges, fittings & aCement Concrete essories etc. all complete, for all depths, as per the direction of Engineer in charge.
Providing expansion joints in Reinforced Cement Concrete framed structure (interior column) with plain premoulded filler 25 milimetre thick including fixing T.W. battens on both faces and finishing as directed etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing expansion joints in Reinforced Cement Concrete framed structure (exterior Columns) with plain premoulded filler 25 milimetre thick and 3 milimetre thick alluminium plate, hold fast, fixing T.W. battens on internal face, finishing etc. complete as directed.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing expansion joints in Reinforced Cement Concrete framed structure (at floor level) with premoulded filler 25 milimetre thick and 3 milimetre thick aluminium plate as required, bitumen poured filler and fixing T.W. battens on rear faces etc. complete as directed.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing expansion joints in Reinforced Cement Concrete framed structure (exterior column) with plain premoulded filler 25 milimetre thick with 75 milimetre wide and 1 milimetre thick stainless steel plate and finishing etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing expansion joints in Reinforced Cement Concrete framed structure (at floor level) with plain premoulded filler 25 milimetre thick with 75 milimetre wide and 1 milimetre thick stainless steel plat and finishing etcetera complete.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing & Fixing in position, Carpet more than 800+ gsmetre, made with100% stain proof fibres of approved make along with 5milimetre underlay as per Architectural & Acoustical Design & Instructions & Complete in all aspects including all materials labour,finishing etc complete. First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing wooden flooring with imported make veneer paper fixed on MDF Board of 8mm thick and width of 200mm U Shaped Notch to hold the sheets in perfect flooring design brand of Stilex Wooden moulding of imported make veneer paper fixed on MDF wood with finished edges which is used at the end of wooden flooring and to the notches for affixing the wood to the flooring with 8mm Hilton below flooring and rubber adhesive to stick (Sample to be got approved from Exe. Engineer before use). First Floor
Second Floor
Third Floor
Fourth Floor
Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing frame work of anodised aluminium sections for suspended false ceiling consisting of aluminium T 50 milimetre x 40 milimetre weighing 0.39 Kilogram/metre at 60 cms c/c and fixed with ( 15 x 15 milimetre ) flanges weighing 0.119 Kilogram/m suspended on 6 milimetre diamatre mild steel rod weighing 0.22 Kilogram/m fixed on wall and beams including rounding of the edges with aluminium T of 50 milimetre x 40 milimetre weighing 0.39 Kilogram/m etc. including all labour etcetera complete. First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing false ceiling of 10 to 12 milimetre thick decorative boards of fibrous plaster of paris including scaffolding if necessary all architectural work like mouldings, cornices, coves, domes, cups as per detailed drawings and three coats of spray painting to boards etcetera complete. (excluding frame work, runners and mild steel suspenders). First Floor
Second Floor
Third Floor
Fourth Floor
Providing & fixing large heigHight file storage cupboard by 18 milimetre thick ply Indian standred:710 for top, verticals, horizontals supports, shutters and 12 milimetre thick ply Indian standred:710 for back side & 25 x 15 milimetre Teak wood leaping for grooves for hinges and external plywood finished with 1 milimetre thick laminate and internal with french polish, melamine polish respectively finished with brass hinges, screwes, handles, locks as per detail drawing. excetra . complete First Floor
Second Floor
Third Floor
Fourth Floor
Providing & fixing side storage unit using 18 milimetre thick and 12milimetre thick ply Indian standred:710 grade plywood confirming to Indian standred:710 at top,bottom,side,drawers & shutters also & Teak wood lipping on edges. exposed faces to bo finished with 1 milimetre thick. Laminate cofirming to Indian standred:2046 and internal surfaces with Melamine polish. Including all neccessary hardwares such as stainless steel hinges,telescopic channels, handles, locks, excetra complete. First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing Executive Table of approved size made of 18 milimetre thick plyIndian standred:710 grade plywood confirming to Indian standred:710 for vertical supports & top & 12 milimetre thick ply Indian standred:710 grade plywood confirming to Indian standred:710 extra for design with teak wood moulding at edges and front. Providing 1 milimetre thick texture laminate on all exposed surfaces & 12milimetre thick clear glass top with fittings. Melamine polish to teak wood molding & Internal surfaces finished excetra complete. First Floor
Second Floor
Third Floor
Fourth Floor
Providing & fixing Computer table using 18 milimetre thick ply Indian standred :710 grade plywood confirming to Indian standred:710 for top, vertical supports and top, keyboard drawer is made by using 12 milimetre thick ply Indian standred:710 grade plywood confirming to Indian standred: 710 and telescopic channels on side, external surface is to be finished with 1 milimetre thick laminate with 6 milimetre horizontal groove including 25 x 6 milimetre leaping and necessary fittings excetra complete First Floor
Second Floor
Third Floor
Fourth Floor
Providing and Supplying VIP Executive Chairs of Godrej, Basset, Lifestyle or equivalent of High Back and full heigHight push back and revolving seat with hydraulic adjestment of multi locking and wheels made of composite leather seat and adjustible fiberour foam handle, Netted chair backrest, Adjustible lumber support, Ajustible heeadrest and finished excetra complete. Model : Leoma First Floor
Second Floor
Third Floor
Fourth Floor
Providing and Supplying Officer's chair of Godrej, Basset, Lifestyle or equivalent medium back Chair of low heigHight push back and revolving seat with hydraulic adjestment and wheels made of cotton fabric finished and fiberour foam handle and finished excetra complete.Model:Greta. First Floor
Second Floor
Third Floor
Fourth Floor
Providing and Supplying Staff chair of Godrej, Basset, Lifestyle or equivalent medium back Chair of low heigHight push back and revolving seat with hydraulic adjestment and wheels made of cotton fabric finished and fiberour foam handle and finished excetra complete.Model:Pulse First Floor
Second Floor
Third Floor
Fourth Floor
Providing and supplying Visitor Chair of Godrej, Basset, Lifestyle or equivalent fix back and seat made of composite leather coushoning and fibour foam handles fixed on stainless steel frame of 45 milimetre x 45 milimetre pipe and finished excetra complete.Model:Oxbo First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing with 25 milimetre steel curtains rod with stainless steel decorative bracket with Shunnel cloth for curtains excetra complete. First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing Roller Blinds for windows finished and complete as per design. First Floor
Second Floor
Third Floor
Fourth Floor
Providing and supplying Sofa set with wooden frame Work and 75milimetre nylon spring patti with 50 density super soft 'U' foam covered with shunnile cloth of décor company make as per design and shade excetra complete First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing Conference Table of approved size made of 18 milimetre thick ply Indian standred :710 grade plywood confirming to Indian standred :710 for vertical supports and top and 12 milimetre thick ply Indian standred :710 grade plywood confirming to Indian standred :710 for front with teak wood moulding at edges and front. Providing 4 milimetre thick Venner on all exposed surfaces, Melamine polish to teak wood moulding to internal surfaces as per Design excetra complete. First Floor
Second Floor
Third Floor
Fourth Floor
Providing & fixing 75 milimetre thick Partition with Veneer and Glass finished using 18 milimetre thick Indian standred :710 grade plywood confirming to Indian standred :710 for frame work fixed to wall, floor and slab with vertical and horizontal supports and covered with 12 milimetre thickIndian standred :710 grade plywood confirming to Indian standred :710 from both sides and finished with 4 milimetre thick Veneer from both side and 12 milimetre thick glass as per design and finished.excetra complete . First Floor
Second Floor
Third Floor
Fourth Floor
Providing and Fixing Door panelling with Veneer and glass Finished using 18 milimetre thick indian standred:710 grade plywood confirnming to indian standred:710 for vertical supports and covered with 6 milimetre thick indian standred:710 grade plywood confirnming to indian standred:710 for frame also including 8 milimetre thick clear glass fixed 40 milimetrer x 6 milimetre Teak Wood moulding. External side to be finished with 4 milimeter thick veneer with 6 milimetre horizontal groove with brass hinges, round lock, door closer, fittings excetra. complete. First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing large heigHight file storage cupboard with glass shutters by 18 milimetre thick ply indian standred:710 of approved make for top, verticals, horizontals supports, shutters and 12 milimetre thick ply indian standred:710 for back side and 25 x 12 milimetre Teak wood leaping for grooves for hinges and external plywood finished with 4 milimetre thick venner, 8 milimetre thick clear glass for shutter fixed and internal with french polish and external with melamine polish finished with brass hinges, screwes, handles, locks as per detail drawing. excetra. complete.First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing side storage unit using 18 milimetre thick ply indian standred:710 grade plywood confirming to indian standred:710 at top, bottom, side, drawers and shutters also and Teak .Wood. lipping on edges. exposed faces to bo finished with 4 milimetre thick Venner and internal surfaces with Melamine polishing. Including all neccessary hardwares such as ss hinges, telescopic channels, handles, locks, excetra. complete. First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing Executive Table of approved size made of 18 milimetre thick ply indian standred:710 grade plywood confirming to indian standred:710 for vertical supports and top and 12 milimetre thick ply indian standred:710 grade plywood confirming to indian standred:710 extra for design with teak wood moulding at edges and front. Providing 4 milimetre thick venner on all exposed surfaces and glass top with fittings. Melamine polish to teak wood molding and Internal surfaces finished excetra complete. First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing Center table and Side Table using 18 milimetre thick plywood indian standred:710 grade .plywood confirming to indian standred:710 for vertical supports and frame and using 12 milimetre thick glass fixed on stainless steel glass stud for tops. External side to be finished with 4milimetre thick Venner excetra completed. First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing Wall panelling with Venner using 18 milimetre thick ply indian standred:710 grade .plywood confirming to indian standred:710 for vertical supports of size 50 milimetre x 50 milimetre and covered with 12 milimetre thick ply indian standred:710 grade .plywood confirming to indian standred:710 and external side to be finished with 4 milimetre thick Venner with Teak.Wood. beading groove and completed as per detail drawing. First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing Wall panelling with Acrylic Solid Surfaces (L.G./Euro/Solido) make using 18 milimetre thick ply indian standred:710 grade .plywood confirming to indian standred:710 for vertical supports of size 50 milimetre x 50 milimetre and covered with 12 milimetre thick ply indian standred:710 grade .plywood confirming to indian standred:710 and external side to be finished with 6milimetre thick Acrylic Solid Surfaces using arcylic adhesives for pasting on it with approved color and design which can be cut, shape, mould and thermoformed into required shape and size and completed as per detail drawing. First Floor
Second Floor
Third Floor
Fourth Floor
Providing and Supplying Conference Chair of Godrej, Basset, Lifestyle or equivalent full heigHight push back and revolving seat with hydraulic adjestment and wheels made of composite leather and adjustible fiberour foam handle and finished excetra. complete. Model: Marvel First Floor
Second Floor
Third Floor
Fourth Floor
Providing and Supplying Stage Chair of Godrej, Basset, Lifestyle or equivalent full heigHight adjustible push back and revolving seat with hydraulic adjestment and wheels made of composite leather and fiberour foam handle and finished excetra. complete. Model:Marvel First Floor
Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. Reinforced Cement Concrete pardi/ Wall and all type of Interior, Exterior Compound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 milimetre / 25 milimetre including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge) First Floor
2150milimetre H x 2745milimetre W x 900milimetre D - BASE FRAME : Base Frame shall be fabricated in channel Type from minimum 2.5 milimetre thick MS Sheet Size of Channel 25milimetre x 100milimetre x 45milimetre GUIDE RAILS : The guide rails shall be made out of 28milimetre BrigHight bar placed on 1.2 milimetre thick metre S. Plate which will be above the floor and are as per the international standard of safety. SUPER STRUCTURE : Super structure of the Mobile storage system will consist of knock down type panels. All the components such as shelves, front panel, end panel, vertical rear panel, central partition etc. Will act as an integral member of the Unit. SHELVES : Shelves made of 22SWG thick Prime Quality C.R.C.A. having 10 folds each will be provided each designed to carry a U.D.L. of 70 Kilograms. VERTICAL PANEL : Vertical panel consists of the front, Centre & rear panel shall be made out of 20SWG thick C.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to cover the entire drive mechanismetre CENTRE PARTITION : The Centre partition will comprise of a full C.R.C.A. prime quality Mild Steel 22SWG Sheet. LOCKING : System will be provided with individual rack locking as well as centralised locking arrangement on the last unit when all units are brougHight together, central lock when operated gets locked with the floor & does not allow aCement Concrete ess to the units. DRIVE MECHANISM : Driving Mechanism will be provided externally supported on special grade anti-friction bearing to have smooth & effortless movement. Entire mechanism or gear & sprockets shall be incorporated within the front panel provided in the front of the unit within an area of 1000milimetre x 200milimetre x 60milimetre DRIVING WHEEL : Fully Powder Coated three pronged drive wheel for better torque & free movement of the rack over the guide rail. INDEXING ARRANGEMENT : Acrylic card holders provided on the front panel for easy identification & retrieval. FINAL FINISH : Powder Coating (8 tanks process with 70 microns). First Floor
Second Floor
Third Floor
Fourth Floor
Providing & fixing foot rest work of 6,12,18 millimeter thick I.S.710 grade marine plywood confirming to I.S.I.710 all exposed surface shall be covered with 1 millimeter laminate including necessary hardware, labor etc. complete as per directed by Engineer in charge. First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing Notice Board outside of Court Hall of size 1.22 x 1.22 x 0.20 with 1 millimeter laminate on external surfaces & 5 millimeter plain glass with handles & lock, soft board and blazer cloth fixed on the inside back etc. complete as directed by engineer in charge First Floor
Second Floor
Third Floor
Fourth Floor
Providing and Fixing Steel Letters with 1" thick, heigHight 300 to 500 millimeter on wall including scaffolding, screwing and buffing if necessary etc. complete as per directed by Engineer in Charge First Floor
Providing Reinforced Cement Concrete parapet with M-20 Cement concrete of trap / granite / quartzite / gneiss metal with cast in situ / precast panels as per the detailed drawing heigHight of 1.1 Metric Tonne above top of road surface, with post of 225 milimetre x 190 milimetre at 2 meter or less at equal distance suitable to span having 10 milimetre reinfoReinforced Cement of minimum 4 bars and 6 milimetre stirrups and R.C.C panels of approved design at clear distance of 125 milimetre and thickness of 150 milimetre with 10milimetre diamatre 3 no.of bars reinfoReinforced Cement at top and bottom and 6 milimetre diamatre 4 no.bars as vertical or horizontal rails of size 100 milimetre x 150 milimetre and with clear speacing of 240 milimetre including scaffolding, steel centering, plywood/steel formwork, compacting finishing, uneven and honeycombed surface with C.metre 1:3 of sufficient minimum thickness to give a smooth and even surface and curing etcetera complete. (Including cost of reinfoReinforced Cement & cover block.)
Planting large flawering/Shady trees(Hight.1 Metre)- Digging pit with size 0.9m x 0,9m x 0.9m,removing and conveying unwanted stuff to a required distance as directed. Filling the pit with approved excavated material upto a heigHight of 0.30m, and remaining heigHight of 0.60m,with fresh garden soil & manure in 3:1 proportion. Mixing soil & manure thoroughly well, leveling,as directed, watering previous nigHight, planting one to two year old minimum 1 Mtr heigHight, healthy trees sapling as per specifications. Maintaining till well established by watering, weeding, stirring of soil replacing of casualties etc. complete.
Planting large flowering/Shady treesf Hight. 2 Metre)- Digging pit with size 0.9m x 0.9m x 0.9m,removing and conveying unwanted stuff to a required distance as directed. Filling the pit with approved excavated material upto a heigHight of 0.30m. and remaining heigHight of 0.60m.with fresh garden soil & manure in 3:1 proportion. Mixing soil & manure thoroughly well, leveling,as directed, watering previous nigHight, planting two to three year old minimum 2.0 MetreheigHight ,healthy trees sapling as per specifications. Maintaining till well established by watering, weeding, stirring of soil replacing of casualties etc.complete.
GARDEN SOIL:-Supplying on site garden soil well sieved 90% to pass through I.S.sieve of 10mm size free from stones rubbish like dried grass roots and other such materials. The soil should be fresh from quarry. The colour of the soil generally be red.The soil will be measured by measuring box.(Farma) Item includes royalty charges,octroi,corporation Tax Transporting,loading -unloading etc(.Lead charges per 26 kilometre considered.). (As per the Approved quotation attached)
Preparing instant Lawn :- Excavating the ground to a required depth of 20cms,removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil/silt & manure in excavated area in 3:1 proportion to a heigHight of 20cms. Mixing garden soil and manure thoroughly well, levelling, watering on previous nigHight. Planting required variety of lawn grass as directed and maintaining till weeding,clipping, rolling,etc. complete. well established by watering,
Providing and fixing of Structural Glazing with Powder Coated vertical & horizontal aluminium section size 81 mm x 67mm x 2 mm thick weigHighted 1.6 kg/ mtr Outer Frame Section 81 mm x 38.5mm x 2mm thick WeigHighted 1.3 kg/mir & including sash section 67mm x 28mum x 16mm thick weigHighted 0.6 kg/Metre using single glass 6mm St-136 Graphite (Saint-Gobin,) one way reflective toughened glass Glass Fixing with both side adhesive tape & Dow corning Structural Silicon Sealent (No. 795.) Gaps between two Glass panels filling with Dow Corning | weather silicon scalarit (No. 789) fully waterproof. As per Drawing & Design.
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and Fixing GI Elevation fins having sertien 75mm with blank powder conting in finish and fitting with 50mmX50mmX2.9mm MS box pipe framing in required grid size including all necessary fixtureand fastner, Trampartation, Scaffolding the template
First Floor
Second Floor
Third Floor
Fourth Floor
Supplying, installing, testing and commissioning of extendable/non- extendable outdoor type 11 kV 630A load break isolator switch compliant to IEC 62271 -100 200 and 102 on provided MS channels/trench/foundation as per specification no SW-HightS / LBS [5-9-3]
Supplying and erecting Hight CT multifunction DLMS compliance of accuracy of class 0.5 3x63.5V 50 Hz with optical & RS 232 port backlit LCD measures kWh kVAh V I kW 6 months history of energy load survey & displays trivector energy load survey TOD tamper detection & logging power ON /OFF events instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box. [6-3-6]
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. [6-5-2]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-24]
Supplying, erecting & terminating XLPE insulated galvanised steel formed wire armoured (strip) cable 11 kV(UE) 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-Hight [7-3-9]
Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE Hight cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/Hight [7-5-1]
Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE Hight cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/Hight [7-5-5]
Supplying and erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE [7-6-4]
Supplying and laying (including excavation) half round reinforced cement concrete pipe of IS 458 2003 NP-2 class of 150 mm internal diameter in proper line level and slope including providing and fixing collars in cement mortar 1 2 and curing etc. complete. [7-6-6]
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWater Closet) of HDPE for enclosing cable below ground/road surface to required depth complete. [7-6-12]
Supplying and erecting rolled steel joist (girder) pole 175 x 85 mm (19.6 kg/m) with provided base plate in provided foundation as per specification no. OH- PL/RSJ [8-1-12]
Supplying and erecting MS pole bracket for guarding/LT OH line fabricated from ISM channel 75x40x6mm and 550mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT [8-3-3]
Supplying and erecting end pole D. P. Structure for 11/0.415 kV 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100mm x 116 mm x 11 m Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 400 Amps as incomer & 6 Nos.200 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps D.O. fuse Set & L.A. Set. 2 Nos. Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set L.A. A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box Transformer Belt etc.as per drawing (min. 124 Kg. iron work) with necessary clamps Nut-bolts. V cross arm top clip insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete. [8-3-26]
Supplying and erecting ACSR conductor of size - 6/1-4.09 mm (Raccoon) complete. (318.00 kg/km) as per specification No. OH-CON/ACSR [8-4-10]
Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line complete as per specification no. OH-INS/DI [8-5-6]
Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line complete as per specification no. OH-INS/PN [8-5-9]
Supplying and erecting G.I. stay set for poles including loop insulators at inaccessible heigHight with anchor plate 300x300x6 mm. straining screws G.l. stay wire 7/8 SWG G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. [8-6-2]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP ( Neutral - 2 LA-2 FENSING-1) [9-1-1]
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP [9-1-4]
Supplying, installing & testing maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete and recording the results Specification no. EA-MOBI (TRANSFORMER BODY) [9-1-5]
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. [9-2-2]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA- EP. [9-2-3]
Supplying, installing, testing and commissioning of 3 phase 11/0.433 kV 50 Hz. 250 kVA Mineral oil immersed and naturally cooled outdoor type Copper wound Non-sealed transformer delta/star connected with additional neutral brougHight out on load side temperature rise should not Exceed 45? by thermometer in oil and 50? by the resistance method in winding at full load rating using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5% having 7 number of tap positions with standard accessories complete with test certificate with losses below 980 Watts at 50% load 2930 Watts at 100% load as per IS 1180 (part 1) 2014 with necessary permissions of Electrical Inspector as per specification no SS- TR-NSL. [10-1-6]
Supplying and erecting fencing of section having size 2450 mm in heigHight from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG [10-6- 18]
Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in heigHight using B class GI pipe with angle iron supports chain link wire mesh (jali) complete supported on channel iron erected in foundation and painted complete as per specification no SS-AS/DLD [10-6-20]
Providing printed instruction chart for treating persons suffering from electric shock printed in English & Marathi and duly laminated complete. [10-6-22]
Providing pair of duly tested rubber hand gloves as per IS 47705 suitable for working up to 22 kV supply complete. [10-6-23]
Supplying standard first aid box with necessary antiseptic cream medicine for use on wounds due burn crepe bandage gauge bandage medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use scissors anti-septic solution etc. (All above contents shall be of standard makes) [10- 6-24]
Supplying and fixing Polyvinyl Chloride synthetic elastomer electrically insulating mat with class A insulation conforming to IS 15652 – 2006 having 2 mm thickness up to 3.3 kV [10-6-25]
Supplying shock proof leather safety shoes of electrical grade of standard size as IS 11226 14544 duly tested with necessary test certificate from manufacturer. [10-6-28]
second class Burnt Brick masonry with conventional /I.S. type bricks in cement mortar 1 6 in foundation sand plinth of inner walls /in plinth external walls including bailing out water manually striking joints on unexposed faces raking out joints on exposed faces and watering etc. Complete. [16-2-1]
Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete. [16-2-3]
Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete of medium duty (100 Kilogram). [16-2-4]
Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete. [16-3- 1]
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1 3 6 cement concrete (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay). [16-3-6]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials testing & recording the results as per specification no. EA- EP [9-1-2]
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. [9-2-2]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA- EP. [9-2-3]
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 140 kVA output continuous rating 3 Phase 415 V 50c/s 0.8 p. f. A.C supply a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours along with standard accessories self-excited self-regulated screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 % with performance class G2 and maximum fuel consumption 22.85 Ltr/hr 75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters switchgears indicators connected with suitable wires/cables the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet sound absorbing material to restrict sound level up to 75 dB at 1.0 m provided with first filling of oil diesel not less than 290 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG [11-1-14]
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 125 kVA up to 140 kVA capacity Three phase 415 Volts 50Hz A.C. with all standard features safeties etc as per specification no. GEN-AMF. [11-2-12]
Supplying, installing, testing and commissioning of FR XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU [13-9-11]
Excavating hard murum / stone metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables pipes & clearing the site by removing debris & making the site as required complete.(4.45*1.9*0.3) [16-1- 6]
Making cement concrete foundation in 1 2 4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).(SIZE 4.2*1.9) [16-3-5]
Supplying and erecting Polyvinyl Chloride insulated Polyvinyl Chloride round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-14]
Supplying and erecting integrated LED street ligHight fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing having system lumens output of Min. 4400 Lumens min. efficacy of 110 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.95 operating range of 140- 270V inbuilt surge protection of 10 kV Life class of 50 000 Hrs. at L70B50 including driver complete with 3 Years warranty as per specification No FG- ODF/FLS2. [2-4-4]
Supplying, erecting and marking SPMCB 0.5A to 5A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-1]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-27]
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWater Closet) of HDPE for enclosing cable below ground/road surface to required depth complete. [7-6-9]
Providing and erecting 6 m high (clear heigHight) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL [8-2-12]
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT [8-2-21]
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT [8-2-22]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP [9-1-4]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA- EP. [9-2-3]
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel concrete excavation and fixing provided nut bolts with the help of template duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). [16-3-9]
Supplying and erecting HMS Polyvinyl Chloride conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-9]
Supplying and laying HMS Polyvinyl Chloride conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC [1-1-10]
Supplying and laying HMS Polyvinyl Chloride conduit FRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC [1-1-12]
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper Polyvinyl Chloride insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper Polyvinyl Chloride insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper Polyvinyl Chloride insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]
Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper Polyvinyl Chloride insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]
Supplying and erecting mains with 4x 4 sq.mm FRLSH copper Polyvinyl Chloride insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3]
Supplying and erecting mains with 2x4 sq.mm FRLSH copper Polyvinyl Chloride insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3]
Supplying and erecting green colour earthing with 1x 4 sq.mm FRLSH copper Polyvinyl Chloride insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3]
Supplying and erecting mains with 4x 6 sq.mm FRLSH copper Polyvinyl Chloride insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-4]
Supplying and erecting mains with 1x 6 sq.mm FRLSH copper Polyvinyl Chloride insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-4]
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1]
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. [1-6-2]
Supplying and erecting modular type D.P. switch 32A with indicator duly erected on provided plate and box with wiring connections complete. [1-6-8]
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10]
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-11]
Supplying and erecting modular type buzzer 220 / 250V duly erected on provided plate and box with wiring connections complete. [1-6-19]
Supplying and erecting modular type (two module) electronic step regulator for fan duly erected on provided plate and box with wiring connections complete. [1-6-23]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-35]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-36]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-40]
Point wiring for ligHight/bell concealed type in min 20 mm FRLS grade HMS Polyvinyl Chloride conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG- PW/CW [1-7-5]
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS Polyvinyl Chloride conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG- PW/CW [1-7-6]
Point wiring for independent plug in 20 mm FRLS grade HMS Polyvinyl Chloride conduit with 1.5 sq.mm (2+1E ) FRLSH grade copper wire modular type switch earthing and required accessories as per specification No WG-PW/SW [1-7- 14]
Point wiring for ligHight/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm Polyvinyl Chloride conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/HW [1-7-15]
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm Polyvinyl Chloride conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG- PW/HW [1-7-16]
Wiring for plug on board with Switch socket surface/concealed type copper wiring and earthing and with modular accessories as per specification No WG-PW/CW [1-7-26]
Supplying and erecting LED square / circular Max. 7W down ligHighter/ Panel LigHight having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 770 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-2]
Supplying and erecting LED square / circular Max. 18 W down ligHighter/ Panel LigHight having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 2000 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-5]
Supplying and erecting LED Panel LigHight(600mm X 600mm) Max. 35 W having CRCA powder coated housing polystyrene diffuser having system lumens output of Min 4200 Lumens min. efficacy of 120 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-8]
Making suitable size recess in any type of false ceiling for erection of flush type down ligHighter and finishing the background to match the original surface upto 20W. [2-1-13]
Making suitable size of recess in any type of false ceiling for erection of flush type LED panel ligHight 600mm x 600mm/1200x300mm and finishing the background to match the original ceiling surface. [2-1-14]
Supplying and erecting anodized aluminium corridor / passage / mirror ligHight LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided Polyvinyl Chloride Block / wooden board with 3 years warranty. [2-1-16]
Supplying and erecting anodized aluminium corridor / passage ligHight LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided Polyvinyl Chloride Block / wooden board with 3 years warranty. [2-1-18]
Supplying and erecting inverter LED batten 20W tube ligHight fitting with polycarbonate housing heat sink integrated HF electronic driver Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt CRI>80 CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty. [2-1- 22]
Supplying and erecting Electronic type cordless call bell erected on T.W. board having portable bell push working on 9V D.C. battery and (effective range upto 45 meter) bell on 250 V A.C. supply. [2-3-15]
Supplying and erecting fresh air cum exhaust fan of ligHight duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades wire mesh duly erected complete. [2-10-14]
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 PF>0.9 THD<10% with IR remote control/compatible speed regulator Temperature Rise of Max. 40 deg. C having external mounted control PCB completely erected in position as per specification no. FG-FN/CF [2-10-22]
Supplying and fixing anchor type fastener fan hook with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. [2-11-2]
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. [2-11-5]
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with Polyvinyl Chloride three core flexible cable 1 sq. mm copper Polyvinyl Chloride wire. [2-11-6]
Supplying, erecting, testing and commissioning of self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. AP-Water ClosetR/Water Closet [3-3-10]
Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) [3-5-1]
Supplying, installing, testing and commissioning of 3kVA capacity online pure sine wave with backup time of 0.5 hrs. PWM & IGBT based UPS with 0.8 to unity output pf single phase input & 1 phase output complete with all protections as per specification no. AP-UPS [3-7-3]
Supplying, installing, testing and commissioning of 6kVA capacity online pure sine wave with backup time of hrs. PWM & IGBT based UPS with 0.9 to unity output pf single phase input & 1 phase output complete with all protections as per specification no. AP-UPS [3-7-4]
Supplying and erecting 12V/17Ah -18Ah SMF battery with battery terminal wire duly charged with 12 months warranty complete [3-8-8]
Supplying and erecting 12V/26Ah SMF battery with battery terminal wire duly charged with 24 months warranty complete [3-8-9]
Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-2]
Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-3]
Supplying, erecting and marking TPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-10]
Supplying, erecting and marking TPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-11]
Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 4 ways/phase (12 poles) with door 1.2mm thickness surface/flush mounted IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB [5-4-1]
Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 4 ways /12 Poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB [5-4-4]
Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 8 ways /24 poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB [5-4-5]
Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-8]
Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-9]
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13]
Supplying and erecting triple pole and neutral distribution board (TPNDB) 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles) with door 1.2mm thickness surface/flush mounted on iron/GI frame (vertical busbar type) as per specification no. SW- SWR/MCBDB1 [5-4-16]
Providing and erecting 3 Pole MCCB 415 V 100A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-1]
Providing and erecting 3 Pole MCCB 415V 200A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-2]
Supplying, Erecting and Commissioning of 2 pole RCCB 16/25A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-1]
Supplying, Erecting and Commissioning of 4 pole RCCB 16/25A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-4]
Supplying, Erecting and Commissioning of 4 pole RCCB 40A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-5]
Supplying, Erecting and Commissioning of 4 pole RCCB 63A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-6]
Supplying, Erecting and Commissioning of 4 pole RCCB 100A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-8]
Supplying, fixing, and commissioning 2 pole RCBO 6/10/16/20/25A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO [5-6-9]
Supplying and erecting 75 kVAr 440 V 3 phase 50 Hz. Contactor Logic & Intelligent Relay micro APFC passive filter panel consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC [6-7-4]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-17]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-19]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL [7-1-24]
Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm heigHight complete with necessary coupler plates & hardware. [7-11-6]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA- EP. [9-2-3]
Supplying and erecting conventional spike type air termination suitable to carry ligHightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. [9-3-1]
Supplying and erecting HMS Polyvinyl Chloride conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-9]
Supplying and erecting modular type T.V. socket single outlet duly erected on provided plate and box with wiring connections complete. [1-6-14]
Supplying and erecting modular type telephone socket one gang with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-15]
Supplying and erecting Polyvinyl Chloride Surface modular switch box with double mounting plate for 1 module complete duly erected. [1-6-26]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-34]
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. [1-6-35]
Supplying and erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation polyester taped Nylon Rip Cord & grey colour sheathed with FR Polyvinyl Chloride conforming to ITD specification S/WS 113C laid in provided Polyvinyl Chloride casing capping/conduit as per specification No. WG- TW [1-8-1]
Supplying and erecting 10 pair 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier polythene sheathed G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW [1-8-13]
Supplying and erecting co-axial copper cable low voltage grade tri-shielded RG-11 as per specification No. WG-TW [1-8-18]
Supplying, Erecting and Commissioning of MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW [1-9-1]
Supplying, Erecting and Commissioning of 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW [1-9-11]
Supplying, Erecting and Commissioning of 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW [1-9-18]
Supplying, Erecting and Commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete. [1-9-26]
Supplying, Erecting and Commissioning of push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete. [1-9-29]
Supplying, Erecting and Commissioning of IP telephone instrument as per specification complete. [1-9-30]
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC [1-10-1]
Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC [1-10-7]
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC [1-10-16]
Supplying and fixing 2 m UTP patch cord of cat 6 type in position as per specification No. WG-COC/PC [1-10-18]
Supplying, fixing, and configuring 8-ports managed gigabit Layer-2 switch 10/100/1000 base-T POE smart switch plus 2 SFP erected in provided rack complete. [1-11-2]
Supplying, fixing, and configuring 24 ports with 4 (SFP+) port ethernet managed switch with web view/CLI 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWater Closet/GBS [1-11-4]
Supplying, fixing, and configuring broadband ADSL router with all accessories on provided rack as per specification No. WG-NWater Closet/ADSL [1-11- 17]
Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. [1-12-1]
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO [1-12-2]
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP [1-12-4]
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK [1-12-17]
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK [1-12-18]
Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper Polyvinyl Chloride insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper Polyvinyl Chloride insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. [1-6-2]
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-11]
Supplying and erecting Polyvinyl Chloride Surface modular switch box with double mounting plate for 4 module duly erected. [1-6-29]
Point wiring for ligHight/bell concealed type in min 20 mm FRLS grade HMS Polyvinyl Chloride conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG- PW/CW [1-7-5]
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS Polyvinyl Chloride conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG- PW/CW [1-7-6]
Wiring for plug on board with Switch socket surface/concealed type copper wiring and earthing and with modular accessories as per specification No WG-PW/CW [1-7-26]
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. THD<10% p.f. >0.95 operating range of 140-260V in built surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver IP66 IK09 rated on provided Polyvinyl Chloride Block / wooden board with 3 years warranty. [2-1-15]
Supplying and erecting anodized aluminium corridor / passage ligHight LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided Polyvinyl Chloride Block / wooden board with 3 years warranty. [2-1-18]
Supplying and erecting fresh air cum exhaust fan of ligHight duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades wire mesh duly erected complete. [2-10-13]
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF [2-10-21]
Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-3]
Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-8]
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13]
Supplying, Erecting and Commissioning of 2 pole RCCB 40A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-2]
Supplying, fixing, and commissioning 4 pole RCBO 32/40A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO [5-6-13]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-8]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 4 sq mm copper conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-9]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-32]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 10 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-33]
Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials testing & recording the results as per specification no ESE -LA [9-1-6]
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP. [9-2-2]
SITC of Duplex Lift control system for two nos. microprocessor/PLC based simplex lift controllers along with necessary software with programming and hardware e.g. logic board necessary communication/control/data cabling laying in rigid Polyvinyl Chloride conduits/trunking etc. complete. [17-1-21]
SITC of Electric Traction Passenger Lift with · Rated capacity :- 10 Passenger/680 Kg · Floors :- G+1 floor (5 Stops/5 Landings) · Travel :- 3 to 4.2 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0 mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high · Clear Car size of 1300 .mm wide x 1350 .mm deep x 2250 mm high · Lift shaft available having clear size of 2400 mm wide x 1800 mm deep, 1500 mm Pit depth, 4500 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or I d d tt tl b t ) Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED ligHights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency ligHight etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close open/close operation operation from COP etc. The system can record information information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0 MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weigHight with brackets fasteners, counter weigHight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.· General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. For Lift travelling up to six floors or at a speed of 1.0 mps add as below A2 For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid (non-cladded) landing door [Two panel] this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators extension of guide rails shaft wiring with trunking traveling cables main hoisting ropes/belts & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. ADD ON C For additional 2MP Camera along with necessary accessories at Home Landing add as given. (RS.13460*3) SO TOTAL (1299498 + 13701*3 +13460*3 = 1750971 [17-1-4]
SITC of Electric Traction Passenger Lift with · Rated capacity :- 16 Passenger/1088 Kg · Floors :- G+1 floor (5 Stops/5 Landings) · Travel :- 3 to 4.2 mtrs. · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 1000 mm wide x 2000 mm high · Clear Car size of 1600 mm wide x 1600 mm deep x 2250mm high · Lift shaft available having clear size of 2000 mm wide x 3000 mm deep, 1500 mm Pit depth, 4500 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED ligHights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency ligHight etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters, The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weigHight with brackets fasteners, counter weigHight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. ADD ON A3 For Lift having 900mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel] this includes all necessary accessories like LOP's with UP/DN buttons-arrowsindicators extension of guide rails shaft wiring with trunking travelling cables main hoisting ropes/belts & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. ADD ON C For additional 2MP Camera along with necessary accessories at Home Landing add as given. RS. 13460*3 ( RS. 1669432 + 146107*3 + 13460*3)= 2148133/- [17-1-8]
Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 4 ways /12 Poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB [5-4-4]
Supplying, erecting and marking TPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-11]
Supplying, fixing, and commissioning 4 pole RCBO 63A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO [5-6-14]
Supplying, Erecting and Commissioning of 4 pole RCCB 40A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-5]
Supplying, Erecting and Commissioning of 4 pole RCCB 63A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-6]
Supplying, erecting and marking TPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-10]
Supplying, erecting and marking FPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-12]
Supplying, fixing, and commissioning MCB type change over switch 4 pole 25A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS [5-3-24]
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13]
Supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws wall fasteners supports nuts bolts etc. complete. [6-1-12]
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars 500V 100A having 15mm (Width) X 3 mm (Thickness) with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CP-BB [6-2-1]
Supplying and erecting 525 V 3 phase 50 Hz. MPP type capacitor having minimum overcurrent capacity of 1.8 In peak inrush current capacity 300 In and minimum life 150000 hours kVAr bank of metalised polypropylene condensers (MPP) with the standard capacities of 2 3 5 7 10 12.5 and 15 kVAr units of P.F. correction for operation on 3 phase 50 Hz. with externally discharging resistances earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licensee. [6-5- 3]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 4 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-31]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials testing & recording the results as per specification no. EA-EP [9-1-3]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA- EP. [9-2-3]
Supplying and erecting minimum Three & above star rated submersible pump set of 2.25 KW/3 HP with 415 V 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 120 to 390 LPM discharge at 55 to 11 m head & discharge & delivery Pipe of Size-50mm diameter with a necessary H type clamps as per specification No. WP-SMP [12-2-1]
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 3.75 KW/5 HP with 415 V 50 c/s. A.C. supply having delivery head from 43 to 11m and discharge from 120 to 840 litres. per minute & pipe of Suction 65mm / Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP [12- 3-2]
Supplying and erecting flat flexible 3 core 4 sq.mm Polyvinyl Chloride sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. [12-4-9]
Supplying and erecting Polyvinyl Chloride insulated Polyvinyl Chloride round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-14]
Supplying and erecting Water level controller 230/415 V A.C. Four way under ground & Over head tank operation only. [12-4-15]
Supplying and erecting Polyvinyl Chloride coated 5 mm dia. Brass sensor/ electrode duly wired with nuts & bolts complete (Set of 3 Nos) [12-4-16]
Supplying and erecting automatic control panel for 3 Phase 415 volt A.C Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP S.P.P. Combined ammeter/ voltmeter phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing phase reversal phase imbalance etc . [12-4-17]
Supplying, installing, testing and commissioning of FR XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU [13-9-11]
Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. [16-5-6]
Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected to jet/submersible pump with required material complete. [16-5-18]
Supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete. [16-6-15]
Supplying and erecting non return valve 50 mm dia in position made of gun metal complete. [16-6-21]
Supplying and erecting HMS Polyvinyl Chloride conduit FRLS grade 25 mm dia. with Polyvinyl Chloride accessories on wall /ceiling as per specification No WG-MA/CON. [1-2-4]
Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper Polyvinyl Chloride insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper Polyvinyl Chloride insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1]
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10]
Supplying and erecting Polyvinyl Chloride Surface modular switch box with double mounting plate for 3 module duly erected. [1-6-28]
Supplying and erecting 3m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. [1-8-21]
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC [1-10-1]
Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC [1-10-7]
Supplying, fixing, and configuring 8-ports 1 G unmanaged gigabit POE switch erected in provided rack complete. [1-11-1]
Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. [1-12-1]
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK [1-12-18]
Supplying, installing, testing and commissioning of 2kVA capacity online pure sine wave with backup time of hrs. PWM & IGBT based UPS with 0.8 to unity output pf single phase input & 1 phase output complete with all protections as per specification no. AP-UPS [3-7-2]
Supplying and erecting 12V/42Ah SMF battery with battery terminal wire duly charged with 24 months warranty complete [3-8-10]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-14]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3 core 4 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-15]
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWater Closet) of HDPE for enclosing cable below ground/road surface to required depth complete. [7-6-9]
Supply Installation commissioning of 4 MP Full HD IP Dome / Bullet Camera Image Sensor 1/3 4 megapixel progressive scan CMOS Effective Pixels 2304 (H) × 1296 (V) Electronic Shutter Speed Auto/Manual 1-1/100000 s Min. Illumination 0.1 lux F2.1 (Color) 0 lux (IR LEDs on IR Distance - nUp to 100 ft (30 m) Day/NigHight -auto (ICR)/Color/BW BackligHight Compensation - BLC/HLC/DWDR White Balance - Auto/Manual Gain Control - Auto/Manual Noise Reduction - 3D Privacy Masking- Up to 4 areas Lens Focal Length- 2.8 mm Horizontal Angle of View 92° 86°-28 Compression H.264 (Main/High/Baseline Profile) /MJPEG Resolution 3 MP (2304×1296) 1080p Main Stream 3 MP (1-20 fps) 1080p (1-25/30 fps) Corridor Mode Support Network Protocol IPv4/IPv6 HightTP HightTPS TCP/IP UDP UPnP ICMP IGMP RTSP RTP SMTP NTP DHCP DNS PPPoE DDNS FTP IP Filter QoS Compatibility -nONVIF Profile S CGI Max User Access 20 users Mobile App - for iPhone iPad Android Phone and Tablet Power Supply PoE (802.3af) 12 V DC Working Environment -22°F to 140°F (-30°C to 60°C) 10% to 100% RH condensing Ingress Protection IP66 Vandal Resistance - IK10 Regulatory FCC Part 15B Class B
Supplying installing testing & commissioning of High defination 4 Megapixel IP IR PTZ Camera Minimum 1/3 Progressive Scan CMOS image sensor Support H.265+/H.265/H.264 Minimum 25fps 1520p (2688x1520) Focal Length 4.8 mm to 120 mm ONVIF profile conformant IR Distance min. 150 m WDR 120 dB MicroSD/SDHC/SDXC card (256 GB) Support alarm triggering by specified target types (human and vehicle) Min IR distance 150M minimum 4.8-125mm Lens min 16x digital zoom min 30x optical Zoom. White ligHight illuminator 60m 133dB HDR H.265+ H.265 H.264 MJPEG streams Intelligent Dynamic Noise Reduction BLC White Balance Pan Range 360° continuous Tilt Range -90° to 5° (Auto-flip 190°) Pan/Tilt Modes - Pan 0.1°/s - 240°/s Tilt 0.1°/s - 100°/s Presets 256 Tours Audio- 1/1 Channel In/Out Micro SD card support up to 256 32 individually configurable privacy masks Alarm inputs/outputs - 2/1 Dual Power options Any object Object in field Crossing line Entering field Leaving field Loitering Following route Idle object Removed object Counter Occupancy Crowd detection Condition change Similarity search Tampering Object filters based on
Supplying and erecting Supplying erecting and commisioning of 16 channel professional series 4 k HD network video/ audio IP video input 16 ch Two way audio 1 ch RCA network bandwidth 320 MBPS (i/c&OG) remote user 128 protected p2p U pup NTP DHQ video remote user 128 protected p2p U pup NTP DHQ video Audio output HDMI/VGA 1920 x 1080p/ 60 Hz 280x720/60 12 MP/8MP/6MP/5MP/108 Recording resolution Op/960p/720p/p1/2CIF all Audio output LCH RCA 16ch play back corridor mode 3/4 /5/7/9/10/12/16/3 Deced format H265 h 264 Live view play back 12 MP/8MP/6MP/5MP/4MP/3MP 30 16x 1080P 30X Hard disk sata 4s interface upto 10 TB for each serial interface 1xR4585 USB front panel 1xusb 20 Rear panel 1 ALARM 08CH A08um out 4 ch power supply 12 V PC power consumption 12W(without 10cnt (+14 fat 131F) environment Dimentious humidity 590% RH (non condensing) 440 mmx 30 mm (17.3 x 13.5 x 2.0 ) (WXDXH) (weigHight without hdd)< 3.14 kg (6.9216) certification with three year warrenty CE FCC UL) mAKE- HIKVISION
Supply and installation of 8TB surveillance storage Hard Disk Drive-24/7 Surveillance HDD capacity -8 TB interface - SATA III 6 Gb/s Max sustained Transfer Rate OD- 210 MB/s cache-256 MB Tamish Resistant load /unload cycles- 300 000 power on Hours/ year 8760 mean Time Between failures (MTBF) - 1 million hours operating Temperature- Ambient 41 F/5 C(min) Drive case 158 F/70C (max) Non operating Temperature Ambient -40 F/ - 40C (min). Make - Seagate
Supplying and erecting Supply installation and commi-ssioning of 43 full 4k Full HD commercial 4K Led Display monitor /42 inches or higher full HD VGA DVI HDMI LAN USB RGB RS 232C IN / OUT AV IN COMPONENT IN AUDIO IN/OUT WIFI READY SPEAKERS Make- Sony
Supplying and erecting HMS Polyvinyl Chloride conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No WG-MA/CC [1-1-9]
Supplying and erecting Polyvinyl Chloride insulated Polyvinyl Chloride round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-15]
Supplying and erecting Polyvinyl Chloride insulated Polyvinyl Chloride round sheathed 4 sq.mm (56 no. x 0.30 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-16]
Supplying and erecting flush shock proof plug socket 6 pin 6A and 16A with switch 16A combined unit erected in recess in 16 gauge M.S sheet box duly painted and connected with earth terminal and leads [1-5-11]
Supplying, installing, testing and commissioning of split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum 5.00 suitable to operate on 250V 50 Hz A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser minimum 2.5PM filter self diagnosis feature stabilizer free operation & temperature display on indoor unit noise level maximum 50dBA at position as per specification no. APAC/ WAC [3-2-9]
Supplying, installing, testing and commissioning of split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V 50 Hz A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser minimum 2.5PM filter self diagnosis feature stabilizer free operation & temperature display on indoor unit noise level maximum 50dBA at position as per specification no. APAC/ WAC [3-2-10]
Supplying, installing, testing and commissioning of split type room air conditioning unit 2.5TR to 2.7TR capacity with refrigerant R32 415V 50 Hz A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit noise level maximum 50dBA at position as per specification no. AP-AC/WAC [3-2-15]
Supplying and erecting seamless outside & inside smooth dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete. [3-2-26]
Supplying and erecting seamless outside & inside smooth dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete. [3-2-27]
Supplying and erecting seamless outside & inside smooth dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 22mm complete. [3-2-28]
Description Supplying, erecting, testing and commissioning of 20HP VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant for minimum cooling capacity as delivering 100% capacity at 47° C non stop cooling even at 56°C and coefficient of performance (COP) 3.00 to 4.00 modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area rain protection cover built in oil separator accumulator and oil receiver copper tube aluminium fin air cooled condenser condenser fan with motor suitable for 415V±10% 50 Hz 3 phase power supply (all suitable for high ambient conditions) internal copper refrigerant piping internal wiring and refrigerant etc. all housed in powder coated weather proof cabinet complete. [3-11-8]
Supplying, erecting, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.0TR (1100 cfm) to 3.2TR (1165 cfm) having EER as per BEE standards and specifications suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements fan refrigerant liquid and refrigerant piping cordless remote control and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase 230V 50Hz AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. [3-11-22]
Supplying, erecting, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.3TR (1165 cfm) to 4.0TR (1218 cfm ) having EER as per BEE standards and specifications suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements fan refrigerant liquid and refrigerant piping cordless remote control and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase 230V 50Hz AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. [3-11-23]
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system. [4-2-9]
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system. [4-2-10]
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 22 mm for solar water heater/AC system. [4-2-12]
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 28 mm for solar water heater/AC system. [4-2-13]
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13]
Supplying, fixing, and commissioning 2 pole RCBO 6/10/16/20/25A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO [5-6-9]
Supplying, fixing, and commissioning 4 pole RCBO 32/40A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO [5-6-13]
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. [6-1-1]
Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. [3-11-77]
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. [6-1-1]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3 core 4 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-15]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 95 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-24]
Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm heigHight complete with necessary coupler plates & hardware. [7-11-8]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA- EP. [9-2-3]
Supplying, installing, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850LPM at 80 to 60 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 45kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal type single stage centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-F insulation conforming to IS-325. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/SSC/EP [13-1-4]
Supplying, installing, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal/vertical type multi stage centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-F insulation conforming to IS-325. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete as per specification no. FF-MFP/JP [13-2-2]
Supplying, installing, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal/vertical type single/multi stage centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-F insulation conforming to IS-325. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/BP [13-3-1]
Supplying, installing, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following (a) Horizontal type single stage centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade) mechanical seal conforming to IS 1520. (b) Water cooled with radiator diesel engine conforming to relevant IS standard complete with auto starting mechanism 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v 50Hz AC supply diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding residential silencer instruments and protection as per standard specification stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF- MFP/SSC/DP [13-4-2]
Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-2]
Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-3]
Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-4]
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-5]
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-6]
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-P [13-6-7]
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire figHighting system. [13-6-10]
Supplying and erecting 200 mm dia Cast Iron end line strainer of Y-type flanged end pattern PN16 pressure rating screen of SS end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF- VL/ELS [13-7-8]
Supplying and erecting 100 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating as per specification no. FF-VL/SV [13- 7-14]
Supplying and erecting 150 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating as per specification no. FF-VL/SV [13- 7-15]
Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF- VL/BFV [13-7-17]
Supplying and erecting 65 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF- VL/BFV [13-7-18]
Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF- VL/BFV [13-7-19]
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF- VL/BFV [13-7-20]
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF- VL/BFV [13-7-21]
Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV [13-7-24]
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV [13-7-25]
Supplying gun metal double outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV [13-7-36]
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV [13-8- 2]
Supplying and erecting 63mm dia reinforced rubber lined (R.R.L.) hose pipe 15m in length fitted with necessary accessories complete as per specification no. FF-FFA/RRL [13-8-4]
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF- FFA/NZ [13-8-8]
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC [13-8-10]
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia for supplying water in fire tank complete as per specification no. FF- FA/FMC [13-8-11]
Supplying and erecting 300 mm dia 1.5m in heigHight air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT [13-8-12]
Supplying and erecting 20/25mm dia gun metal air release cock with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV [13-8-13]
Supplying and erecting 100 mm dia. pressure gauge 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve erected with provided G.I. pipe elbow etc. complete as per specification no. FF-FFA/PG [13-8-14]
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve G.I. nipple elbow etc complete as per specification no. FF- FFA/PS [13-8-15]
Supplying and erecting brass orifice plate having 6 mm. thickness 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP [13-8-16]
Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8 x 6 ) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) [13-8-19]
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve hose pipe hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8 x6 ) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) [13-8-20]
Supplying, installing, testing and commissioning of remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI [13-9-9]
Supplying, installing, testing and commissioning of FR XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU [13-9-10]
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel central processing unit with the 2 loop capacity and capable of supporting upto 250 devices and detectors per loop with on-board LCD display with min 16 lines of text operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition suitable provision for network connectivity interfacing with third party equipment via a MODBUS/ OPC/ L- ON interface etc. conforming to IS 15908 2021 IS 2189 2008 EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF- AFAS/CP. [13-10-2]
Supplying, installing, testing and commissioning of addressable optical smoke detector single/twin LED’s with 360 degree view suitable for low voltage 15 to 32 V DC two wires supply in-built locking mechanism to check the removal and pilferage of the detector in built isolation mode start up current 300µA and alarm condition current shall be maximum 6.5 mA operating temperature 0°C to 50°C humidity 0-95% RH IP 41 conforming to IS 2189 2008 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF-AFAS/SD . [13-10-6]
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required suitable for temperature variations from - 20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors in built isolation mode suitable for offices/ceiling cable trenches/less ventilation areas etc. with 3 years equipment replacement warranty IS 2175 - 1988 reaffirmed 2000 IS 15908 2021 standards FF-AFAS/SD. [13-10-7]
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type) made of addressable break glass plastic square in shape surface/flush mounted with Break Glass massage embedded on the glass complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP. [13-10-9]
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) 1982 reed relays EN 54 or UL Listed FF-AFAS/CRM [13-10-10]
Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) 1982 Reed relays FF-AFAS/MM [13-10-11]
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) 1982 Reed relays FF-AFAS/ISM [13-10-12]
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908 2021 with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54 conforming to IS 2189 2008 IS 15908 2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH. [13-10-13]
Supplying, erecting, testing and commissioning of 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR[ 13-11-1]
Supplying, erecting, testing and commissioning of 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF- PA/SOC[ 13-11-2]
Supplying, erecting, testing and commissioning of stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector stereo jack complete as per specification no. FF-PA/MIC[ 13-11-3]
Supplying, erecting, testing and commissioning of rust free microphone floor stand of chrome plating/powder coating or S.S. material 500 mm to 1500 mm heigHight and sturdy mechanism ensuring trouble free movement complete.[ 13-11-4]
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC[ 13-11-6]
Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wire complete.[ 13-11-10]
Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler 15 mm (½ ) dia. NBCM Body chrome finished 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR. [13-12-1]
Supplying, erecting, testing and commissioning of vane type water flow detector 75/80 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes.[ 13-12-2]
Supplying and erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. [13-15-1]
Excavating hard murum / stone metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables pipes & clearing the site by removing debris & making the site as required complete. [16-1-6]
Excavating hard murum / stone metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables pipes & clearing the site by removing debris & making the site as required complete. [16-1-6]
Making cement concrete foundation in 1 2 4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps) [16-3-5]
Supplying and erecting ISI mark GI pipe 32 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP. [16-5-10]
Supplying and erecting ISI mark GI pipe 40 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP. [16-5-11]
Supplying and erecting ABC powder type fire extinguisher as per IS 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall. [999-1-379]
Supplying and installing auto glow (Viewing up to 15 mtr length) fire signages in Polyvinyl Chloride/Vinyl 4/6mm thick sheet or as per sample approved by client viz fire hydrant fire hydrant fire extinguishers fire exists fire door fire hose box fire & Electrical & safety etc size 300mm* 100 mm (Rates are taken from previously sanctioned estimate D1104512022-23 Mumbai subdivision vide letter no 173/2022-23 ) [999-1-380]
Supplying and installing auto glow (Viewing up to 15 mtr length) fire signages viz fire hydrant fire hydrant fire extinguishers fire exists fire door fire hose box fire & Electrical & safety etc size 450mm* 150 mm (Rates are taken from previously sanctioned estimate D1104512022-23 Mumbai subdivision vide letter no 173/2022-23 ) [999-1-381]
Supply & Eracting 1000 mm long 25 mm dia. Stainless steel corrugated flexible pipe (hose)nfor dropping sprinkler below false ceiling pipe shall have 16 bar rating and with union/reducer coller clamps etc. as required.
Supply lnstaltation testing & commisrioning of flow switches in 80/100/150 mm dia pipe with all acceslories as required.
Rossette Plate powder coated in white/off white colour with 25 mm dia. Hole.
Spectrum Infrastructure
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid