Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
3 Dec 2026, 3:00 pm6d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Executive Engineer PF DIVN Tirunelveli
Executive Engineer, PF Division , Seevalaperi road , Shanthi Nagar, Tirunelveli
Creation of New WSS
2026_TWAD_731655_1
04/FWSS/25.11.26
Open Tender
Survey
Percentage
Tenkasi and Tirunelveli
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹20,000
26 Nov 2026
26 Nov 2026
4 Dec 2026
26 Nov 2026
3 Dec 2026
26 Nov 2026
90 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Civil | |||||
| 1.01 | Surveying and levelling for the proposed alignment of pipe line by Total station method by engaging qualified Engineers with minimum qualification of B.E.(Civil), Technical Asistant Grade I & II and Mazdoor category I, using the contractor own survey instruments, Special tools and plants vehicle hire charges, transportation, initial incidental charges such as jungle clearance etc. Preparation of Tree map and alignment plan, duly incorporating salient details, such as topographical features, permanent land marks, bench marks etc. at appropriate points, alignment plans and longitudinal section plan at 30 m intervals in addition to other salient locations such as branches,bends,culverts, river crossing etc,with all field particulars in Auto Cad and submission of plan 3 set, along with LF books with making all entries with certification by above qualified Engineers with soft copy and marking TBM stones at required places with bench mark registers soft copies 3 set and hard copy 5 set etc., complete as directed by TWAD Board officers. | - | - | - | - |
| 1.02 | Feeder main for Srivilliputhur Municipality, Surandai Municipality, Kadayanallur Municipality, Ayikudi TP, Keelapavur TP, Sambavar Vadakarai, Sundarapandiapuram TP, Vasudevanallur, Rayagiri TP and Sivagiri TP | 95 | Km | 5,391.75 | ₹5,12,216.25 |
| 1.03 | Distribution system for Srivilliputhur Municipality, Surandai Municipality, Kadayanallur Municipality, Ayikudi TP, Keelapavur TP, Sambavar Vadakarai, Sundarapandiapuram TP, Vasudevanallur, Rayagiri TP and Sivagiri TP | 365 | Km | 5,391.75 | ₹19,67,988.75 |
| 1.04 | Optimal and cost effective design of pipelines as per TWAD Board’s latest pipe policy by using the WaterGEMS software and engaging qualified Engineers team with minimum qualification of B.E. (Civil/Mechanical/Structural/Hydraulic/Electrical) with design experience in WaterGEMS software, Technical Assistant Grade I, II and computer operators etc. for the proposed Distribution System Network from the Service Reservoirs to the House Service Connection location point, such that the pressure heads at the House Service Connections (HSC) are nearly the same for achieving designed discharge at HSCs during operation, by covering the total network length specified by the TWAD officials, duly divided into feasible District Metering Areas (DMAs), by avoiding the crossing of State Highways/National Highways/Railway tracks as much as possible for easier execution, and submission of output reports along with DMA-wise network AutoCAD drawings in the form of soft and hard copies (1 set) and attending remarks, revision of design and drawings as per the instructions issued from the TWAD officials till finalization of Detailed Project Report, satisfying the conditions provided by TWAD Board officials etc., complete and as directed by the TWAD Board officials. | - | - | - | - |
| 1.05 | The overall scope of the work shall be detailed water distribution network using Contractor’s own WaterGEMS software, for the population forecast given with 135 lpcd and prevailing peak factor as per CPHEEO norms; hydraulic model documentation, including input data, assumptions, and model parameters; loading elevations to the hydraulic model from the surveyed elevation data; import data into WaterGEMS and develop an accurate representation of the proposed distribution system; creation of District-Metering Areas (DMAs) for transformation to a 24/7 distribution system; performance analysis reports for various scenarios considering variations in demands, system configurations and operational conditions; calibrate the model using real-world data and conduct sensitivity analysis; optimize the chosen design based on hydraulic simulation results; ensure the definition of system boundary conditions, including demand patterns, reservoir levels, pump schedules and any other relevant parameters. Consider factors such as minimum and maximum pressure requirements, residence time for water in the system, and adherence to water quality standards. Evaluate the performance of the network under normal and extreme conditions, such as peak demand and pipe breaks. Preparation of design output in the form of legible AutoCAD drawings; preparation of DMA-wise and overall pipe summary, junction/node summary, pump report and other relevant distribution design parameters report. The pipe diameter, pressure rating type, accessories/appurtenances requirement (valves and fittings) shall abide by the latest pipe policy of TWAD Board etc., complete. | - | - | - | - |
| 1.06 | To submit the final soft copies and 4 sets of authenticated hard copies of the WaterGEMS design, including the original WaterGEMS working file, DMA-wise AutoCAD drawings etc., complete. | - | - | - | - |
| 1.07 | The output report shall comprise the following details on the designed Water Supply looped distribution network with respect to each DMA in the distribution network (with DMAs labelled appropriately for easy identification), and as directed by TWAD Board officials. | - | - | - | - |
| 1.08 | A. Junctions (Water Delivery Points) – ID, Ground Level (GL) in m, Hydraulic Grade Level (HGL) in m, Residual Head (RH) in m, Demand in lpm, X co-ordinate in m, Y co-ordinate in m, Ward of the Junction.
B. Pipes – ID, From Junction ID, To Junction ID, Existing/Proposed, Flow in lpm, Velocity in m/s, Head loss in m, Head loss gradient in m/km, Pipe nomenclature as per respective IS code, Pipe inner diameter in mm, Length in m, DMA of the pipe, Friction loss coefficient. | - | - | - | - |
| 1.09 | C. Service Reservoir – ID, Label, Number of DMAs, Intermediate population/quantity covered, Ultimate population/quantity, Low Water Level (LWL) in m, Staging Height in m, Capacity required in lakh litres (LL), Capacity provided in LL, Existing/Proposed, Ground Level (GL) in m, Designed Outflow in MLD, X coordinate in m, Y coordinate in m.
D. Abstract of the Length of Pipe – DMA- and diameter-wise as a two-dimensional table.
E. Percentage of Population/Quantity Covered – DMA- and Ward-wise as a two-dimensional table | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.65 MB
BID.pdf
Tender Documents • 25.92 MB
BOQ_878076.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .