| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | L1 | Accepted-AOC Being overall rate reasonable | |
| 2 | L2₹31.0 L+₹56,282 (1.85%)Rejected-Finance GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹33.4 L+₹3.0 L (9.70%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹33.5 L+₹3.1 L (10.2%)Rejected-Finance PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹35.1 L+₹4.7 L (15.4%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
22 Oct 2022, 6:00 pmClosed
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE-411003
REPAIR REWIRING AND REPLACEMENT OF INTERNAL WIRING FITTING AND FIXTURES FLAME PROOF LIGHT CEILING FAN EXHAUST FAN WALL MOUNTED FAN AND GEYSERS FOR CQA A PTL SQAE AND NAI UNDER GE CENTRAL KIRKEE
2022_MES_554582_1
8693/E8 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
EM2 area
Class D Category b(i)
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹90,000
Yes
10 Nov 2022
27 Sept 2022
24 Oct 2022
27 Sept 2022
22 Oct 2022
10 Oct 2022
27 Sept 2022 - 8 Oct 2022
Amount
Taking down existing unserviceable aluminum / copper point wiring of any description & in any position including all fitting and making good the disturbed surface to match with the existing surfaces complete all as specified and directed.
Material and labour for point wiring in PVC conduit of suitable size but not less than 20mm including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sqmm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sqmm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and incl PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall all as specified and directed by Engineer in charge.
All as per Srl item No 2 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.
All as per Srl item No 2 above but point wiring for 5 pin socket outlet, 5 Amps on independent board.
All as per Srl item No 2 above but point wiring for one five pin socket outlet, 15 Amps & 5 Amp on independent board using 2.5 sqmm two run and one run 2.5 sqmm (nominal area) stranded copper conductor cable.
Material and labour for point wiring in casing & caping of suitable size but not less than 20mm including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sq.mm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sq.mm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and including sunk pressed steel terminal boxes made out of 2 mm thick MS sheet concealed in walls with 3mm thick laminated Hylem sheet top cover fixed with brass screws for housing switches, socket, fan regulator etc. for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall all as specified and as directed by Engineer in charge.
All as per Srl item No 6 above but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables1.5 sq.mm. Size.
All as per Srl item No 6 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.
All as per Srl item No 6 above but point wiring for 5 pin socket outlet, 5 Amps on independent board.
All as per Srl item No 6 above but point wiring for one five pin socket outlet, 15 Amps & 5 Amp on independent board using 2.5 sqmm two run and one run 2.5 sqmm (nominal area) stranded copper conductor cable.
Material and labour for point wiring for one light/ fan/ bell point controlled by one switch in steel conduit with all steel enamelled fittings such as elbow bends, junction boxes, supporting clamps for proper hanging arregements made out from 20x1mm flat aluminium patti including nuts, bolts and bending to shape etc. of appropriate size but not less than 20mm on surface with two run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 Sqmm nominal cross sectional area 1100 volts grade and including one run of 1.5 sqmm (green colour) PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire incl. suitable size sunken type Galvanised pressed sheet steel 1.6 mm thick terminal box of suitable size with 3 mm thick laminated hylum sheet for mounting switches, sockets etc. and making good the disturbed wall and painting the same with matching colour of the existing wall, incld material all as specified and directed.
All as per Srl item No 11 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.
All as per Srl item No 11 above but point wiring for 5 pin socket outlet, 5 Amps on independent board.
All a s per Srl item No 11 above but point wiring for one five pin switch socket outlet combination, 15 Amps & 5 Amp (independent) with using 2.5 sqmm two run and one run 2.5 sqmm (nominal area) stranded copper conductor .
Supply and fix switch flush type, 5 Amps, single pole, one way , 230 volts AC circuit complete all as specified & directed
Supply and fix switch flush type, 5 Amps, Bell push , flush type , 230 volts AC circuit complete all as specified & directed
Supply and fix socket outlet, five pin, 5 Amps, flush type, multipurpose, 230 volts AC circuit complete all as specified & directed
Supply and fix switch flush type, 15 Amps, single pole, one way , 230 volts AC circuit complete all as specified & directed
Supply and fix Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type , flush type, 230 volts AC circuit complete all as specified & directed
Supply and fix ceiling rose PVC/polycarbonate, isolated body, three terminals, complete all as specified & directed .
Supply and fix in repairs Stepped type electronic fan regulator flush type suitable for ceiling fans, prewired 230 volts AC 50Hz supply 100Watt complete all as specified & directed.
Dismantling and Taking out old unserviceable copper/aluminium sub main wiring/Unarmoured cable (used as Sub main wiring) from any height of any Size and Core with all connecting accessories incld. conduit or casing caping and incld. making good to the disturbed wall and painting the same with matching paint as of existing wall including material all as specified and directed by Engineer in charge.
Material and Labour for Sub main wiring at any height with 2 single core PVC insulated, multi stranded copper conductor cable (FRLSH), unsheathed, 2.5 sqmm, 1100 volt grade conforming to IS drawn through and including New 20 mm size steel conduit and including one single core PVC insulated multi stranded unsheathed copper conductor cable, 2.5 sqmm,, FRLSH green in colour as continuous earth wire including all accessories and fixing arrengements, supporting clamps, bends, sockets and connecting items etc. all as specified and directed.
Material and labour for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 4.0 Sqmm, 1100 volts grade, drawn through and including New PVC non metallic conduit 20 mm dia including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 4.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire all as specified and directed by Engineer in charge.
Material and labour for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 4.0 Sqmm, 1100 volts grade, drawn through and including casing caping including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 4.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire all as specified and directed by Engineer in charge.
Material and labour for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 6.0 Sqmm, 1100 volts grade, drawn through and including casing caping including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 4.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire all as specified and directed by Engineer in charge.
Dismantling and drawing out old unserviceable Sub Main Aluminium/copper wiring from Existing Steel/PVC Conduit of any size and any type from any height with all connecting accessaries (excluding conduit or casing caping) and making good the disturbed wall and painting the same with matching to existing wall including material all as specified and directed by Engineer in charge.
Material and labour Sub main wiring at any height including using two single core PVC insulated copper conductor cable (FRLSH) of size 1.5 sqmm 1100 volt grade conforming to IS drawn through existing Steel/ PVC conduit including 1.5 sqmm. PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and directed.
Material and labour Sub main wiring at any height including using two single core PVC insulated copper conductor cable (FRLSH) of size 2.5 sqmm 1100 volt grade conforming to IS drawn through existing Steel/ PVC conduit including 2.5 sqmm. PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and directed.
Material and Labour for Sub main wiring at any height with four single core PVC insulated copper conductor cable (FRLSH) of size 6 sqmm 1100 volt grade conforming to IS drawn through Existing Steel / PVC conduit including two single core 6.0 sqmm PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and directed. (Note for item No 27 to 30) - (a). Two/Four runs of wiring cable and One/two runs of earth continuity wire shall be measured as one length.
Disconnecting and taking down old existing damaged metallic rigid steel conduit of any size and any type from any height with all fittings complete.
Supply and fix in repairs hot galvanised rigid steel conduit 25 mm dia, light grade, at any height with and incld. of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, screws, clips, plugs, clamps etc. for securing , conduits etc. to walls,ceiling, steel joists etc. complete all as directed by Engr-in-Charge. MAKE :- Jindal/Kalinga/ BEC.
Supply and fix in repairs hot galvanised rigid steel conduit 20 mm dia, light grade, at any height with and incld. of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, screws, clips, plugs, clamps etc. for securing , conduits etc. to walls,ceiling, steel joists etc. complete all as directed by Engr-in-Charge. MAKE :- Jindal/Kalinga/ BEC.
Disconnecting and taking down old distribution Box with MCB/fuse grip TPN/SPN DB 2 Way to 12 Way old type DB including taking out all cable connections of any description and in any position and making good the disturbed surface of walls, to match with the existing surfaces complete all as specified and directed by Engineer in charge.
Supply and fix in repairs connecting & testing of VTPN DB of 12 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damage like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed of Make Legrand Cat.No. 507748 or equivalent in Schneider/L&T. NOTE :- MCCB , MCB will be measured and paid separately under relevant item of this schedule.
Supply and fix in repairs connecting & testing of VTPN DB of 8 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed of Make Legrand Cat.No. 507745 or equivalent in Schneider- Acti-9/ L&T-Exora. NOTE :- MCCB , MCB will be measured and paid separately under relevant item of this schedule.
Supply and fix connecting & testing of VTPN DB of 4 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed of Make Legrand Cat.No. 507745 or equivalent in Schneider- Acti-9/ L&T-Exora. NOTE : MCCB , MCB will be measured and paid separately under relevant item of this schedule.
Supply and fix connecting & testing SPN DBs of 8 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed of Make Legrand Cat.No. 507611 orequivalent in Schneider/L&T.
Supply and fix connecting & testing SPN DBs of 12 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed of Make Legrand Cat.No. 507612 or equivalent in Schneider/L&T.
Supply and fix Thermal magnetic adjustable MCCB 160 Amps 4 pole with breaking capacity 25 KA & shall be Ics=Icu 100%, complete all as specified and directed equivalent to Make Legrand-DPX3 cat No 420057 / Schneider-NSX/L&T.
Supply and fix Thermal magnetic adjustable MCCB 100 Amps 4 pole with breaking capacity 25 KA & shall be Ics=Icu 100%, complete all as specified and directed equivalent to Make Legrand-DPX3 cat No 420057 / Schneider-NSX/L&T.
Supply and fix Thermal magnetic adjustable MCCB 63 Amps 4 pole with breaking capacity 25 KA & shall be Ics=Icu 100%, complete all as specified and directed equivalent to Make Legrand-DPX3 cat No 420057 / Schneider-NSX/L&T.
Supply and fix MCB 40 to 63 Amps, TP "C" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly complete all as specified and directed. Make - Legrand/ABB/L&T/ Seimens.
Supply and fix MCB 6 to 32 Amps, single pole and neutral, "C" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly complete all as specified and directed. Make - Legrand/ABB/L&T/ Seimens.
Supply and fix MCB 6 to 32 Amps, single pole 'C' curve, 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded on/ off indication on dolly, complete all as specified and as directed. MAKE :- Legrand/ABB/L&T/ Seimens.
Supply and fix connecting and testing in replacement Industrial Earth Plug & socket with sheet metal enclosure of IP44 rating electric driven single phase including MCB 'C' series SP 20 Amps and supplied with neutral links complete all as specified and directed.
Supply and fix connecting and testing in replacement Industrial Earth Plug & socket with sheet metal enclosure of IP44 rating electric driven three phase including MCB 'C' series TP 20 Amps and supplied with neutral links complete all as specified and directed.
Dismantling and Taking down unserviceable any light fitting from any location/height after disconnecting of electrical connection complete including all connected accessories all as directed by Engr-in-Charge.
Supply and fix LED tube light fitting suitable for and including 1x20 Watt 4 feet long tube with polycarbonate diffuser complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed. Make Crompton Cat part no-Bright Linea CCS-100-20-65-HL2-DP-NWH or equivalent
Supply and fix LED tube light fitting suitable for and including 1x10 Watt 2 feet long tube with polycarbonate diffuser complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed. Make Crompton Cat Part no-Trim Linea New CCS-100-20-65-HL2-DP-NWH or equivalent
Supply and fix 18 Watt 1' x 1' LED recessed mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed. Make Crompton Cat Part no-Polaris Nio-I LCTLRNE-18-CDL or equivalent
Supply and fix 36 Watt 2' x 2' LED recessed mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed. Make Crompton Cat Part no-Polaris Nio-I LCTLRNE-36-FO-CDL or equivalent
Supply and fix 18 Watt 1' X '1 LED Surface mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed. Make Crompton Cat Part no-Polaris Nio-III LCTLSNE-18-FO-CDL or equivalent
Supply and fix 36 Watt 2' x 2' LED Surface mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed. Make Crompton Cat Part no-Polaris Nio-III LCTLSNE-36-FO-CDL or equivalent
Supply and fix 12W LED Round recessed mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed. Make Crompton Cat Part no-Pearl Ultima -R LSCRM-12W-CDL or equivalent
Supply and fix 1X18W,4 Feet LED Ceiling suspended light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed. Make Crompton Cat Part no - Vogue line CCP-121-18-57-SL-NWH or equivalent
Supply and fix 40W,1ft x 4 ft LED recessed mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed. Make Crompton Cat Part no-SPAN LCTLRNE-40-CDL(1X4) or equivalent
Supply and fix 20W, 4 ft LED recessed mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed. Make Crompton Cat Part no-Trend-II LCLR66-30-CDL or equivalent
Supply and fix 1X16W, 4 ft LED Flame proof light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed. Make Crompton Cat Part no-FIAMMA EXTN1LT8-16/20 or equivalent
Supply and fix 20W Double End LED Tube rod including connecting up in existing normal/flameproof fitting & make batten functional complete with all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed. Make Crompton Cat Part no Ultron LT8-20-865(2) or equivalent
Supply and fix 20W Single End LED Tube rod including connecting up in existing fitting & make batten functional complete with all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed. Make Crompton Cat Part no ECO DIJB12LT8-20 or equivalent
Material and labour for earthing complete with galvanised steel pipe electrode, 40 mm bore, medium grade, 2.5 meters length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthling lead of 32x6 mm galvanised iron or steel strip all as shown in Plate No. 4 to the earthing test point all as specified and indicated including testing on completion including excavation and earth work opf any strata, pit cover , funnel etc and connected items complete all as specified and directed.
Supply and fix in replacement GI strip 32 mm x 6 mm to be buried in ground as earth continuity conductor to be fixed from test point to test point complete all as specified and directed.
Taking down and servicing of ceiling fan 1200/1400 mm sweep at site and removing of old grease from bearing of ceiling fan and re-filling new grease including replacement of worn out nut bolt/ washer, rubber seal bush, canopy and reassembling the fan complete and hanging on its original/ new position as directed by Engr-in-charge. NOTE :- MS nut bolts with spilt pin, Ball bearing and Gun metal bush will be paid and measured seperately.
Supply only MS Nut bolts with split pin as per sample and as directed by Engineer-in-Charge.
Supply only Ball bearing suitable size of ceiling fan and exhaust-fan of any type and size .
Supply only gun metal bush suitable for ceiling fan and exhaust fan any type and size including removing old one. NOTE :- Item No. 65 to 67 will be fixed under Item No 64
Material and labour opening the body cover of Ceiling fans 1200/1400 mm sweep any type and make and cutting the existing worn out winding with out damaging the startor removing the coil insulation and putting new insulation of polyster paper, winding with super enameled copper wire of suitable gauge with correct number of turns of auxillary and main winding and varnishing and backing complete including the soldering new lead of copper wire testing complete including transportation to work shop and back all as directed. NOTE : - a) Contractor have to make the arrangement for testing of Rewinded fan upto 24hrs at Complaint cell of AGE E/M-II (C) Kirkee and in case of failure to above said testing a penalty of Rs 200/- per fan is deducted from contractors due and rewinding of same once again is bonded b) Fan should be return to MES yard after rewinding within 10 day from the date of issue otherwise a penalty of RS 10/- per day per fan is deducted from contractor due.
All as per Srl item No 68 above but exhaust fan Upto 300 to 350mm sweep.
All as per Srl item No 68 above but wall mounted fan 400mm sweep.
Material and labour flexible wire of size 23/0.0076 for ceiling fan connection including taking down the old unserviceable wire complete all as specified & directed by Eng-in-charge.
Material and labour for Preparation of old painted surface of ceiling fan and applying one coat of synthetic enamel paint with spraying paint on machine including making MES number on body of the fan including taking down and refixing and connection and testing complete all as specified & directed by Engr-in- charge.
Supply and fix in repair fan capacitor 2.5 mfd 240 V AC supply. MAKE :- Havells/Siemens/Epcos
All as per item No 73 above but 4 mfd. MAKE :- Havells/Siemens/Epcos
Supply and fix exhaust fan louvers suitable upto 300 mm inplace of taking out old one louvers/grills/jalli including necessary grouting nuts and bolts holding for louvers from outside of building.
Supply and fix insulated enclosure 2 pole suitable for SPN MCB including taking out old one. Note : MCB shall be measured and paid separately.
Supply and fix LED Driver for ffittings 10W/ 20W. MAKE :- CG/HPL/Bajaj
Taking down carefully storage type 25 liters capacity water heater (Geyser) after disconnecting inlet/outlet/vent pipes, electric/earth connections etc cleaning of the body inlet/outlet/vent pipes stop cocks non return valves etc leakage arresting of inner copper/steel tank by welding/brazing etc reassembling the geyser by replacing gaskets worn out nuts washetrs etc refixing the same in position by replacing mounting bolts and nuts reconnecting all inlet/outlet/vent pipes electric/earth connections and carrying out testing for proper functioning all as directed by Engineer-in-Charge for geyser of capacity. NOTE :- Non return valve stop cock, PVC/Copper connections cable glass wood thermostat etc shall be measured separately.
All as per Srl item No 78 above but for water heater (Geyser) 50 liters capacity.
Supply and fix in repairs heating element of storage type water heater of compatible type including making all connections by replacing inter connecting copper conductor cables and removal of old unserviceable elements all as directed by Engineer-in-Charge of capacity 1.5 Kilo Watt ISI Marked. MAKE :- DITZ
All as per Srl item No 80 above but for water heater of 2.0 Kilo watt capacity.
Supply & fix thermostat suitable for 25/50 litre capacity storage type water heater including removal of old unserviceable ones as directed by Engineer-in-Charge. MAKE :- DITZ
Supply and fix in repairs non return valve (gun metal) suitable to 15mm bore of pipe.
Supply and fix in repairs non return valve (gun metal) suitable to 20mm bore of pipe.
Supply and fix fusible plug suitable for 25/50 litre capacity storage type water heater including provn of necessary GI fittings removal of existing valves.
Supply and fix CPVC SDR 11 fittings union of size 16 mm dia bore including taking down old u/s GI union.
Supply and fix indicator lamp assembly complete for water heater (geyser) suitable to work on AC 230 V supply and to match the existing size any type including disconnecting and removal of old ones.
Preparation of old painted surface of 50/25 liters storage type water heater and applying two coats of white synthetic enamel paint of approved make as directed.
Supply and fix ceiling fan of 1200 mm sweep 3 star rating including provision of cable from ceiling rose or connector to fan,anchor bolt for fixing of ceiling fan,ceiling fan rod at any height Complete all as specified & directed by Eng-in charge. Make: Bajaj Cat part No. Sabse Tez EE03 251119 or equivalent
Supply and fix exhaust fan (Metal body) AC single phase 230/240 V of size 225 mm sweep with louvres and provn of flexible copper cord from ceiling rose to fan including making hole in wall without making disturbed the good surface Complete all as specified & directed by Eng-in charge. Make :Bajaj Cat part No: Bahar 70000 or equivalent
Supply and fix Wall mounted fan 400mm sweep 230V, AC, SP oscilating swing type with all acceessories and fixing arrengement Complete all as specified & directed by Eng-in charge Make: Bajaj Cat part No.Neo spectrum Grey 250890 or equivalent
Supply and fix in repairs of CPVC pipes of 16mm bore SDR 11 and plain CPVC SDR 11 fittings on wall/ ceilings or laying on floors complete all as Specified
Supply and fix in repairs of CPVC pipes of 20mm bore SDR 11 and plain CPVC SDR 11 fittings on wall/ ceilings or laying on floors complete all as Specified
Supply and fix modular switch one way 6 Amp 1 module. MAKE :- Anchor/Crabtree/Havells/ Indo Asian (Shynora)
Supply and fix modular white cover plate with frame ,3 module. MAKE :- Anchor/Crabtree/Havells /Indo Asian (Shynora)
Supply and fix modular white cover plate with frame ,6 module. MAKE :- Anchor/Crabtree/Havells /Indo Asian (Shynora)
Supply and fix modular white cover plate with frame ,8 module. MAKE :- Anchor/Crabtree/Havells /Indo Asian (Shynora)
Supply and fix metal flush box 3 module. MAKE :- Anchor/Crabtree/Havells /Indo Asian (Shynora)
Supply and fix metal flush box 6 module. MAKE :- Anchor/Crabtree/Havells /Indo Asian (Shynora)
Supply and fix metal flush box 8 module. MAKE :- Anchor/Crabtree/Havells /Indo Asian (Shynora)
Supply and fix modular switch one way 16 Amp 1 module. MAKE :- Anchor/Crabtree/Havells /Indo Asian (Shynora)
Supply and fix modular socket , 6 A -2/3 pin combined 2 module. MAKE :- Anchor/Crabtree/Havells /Indo Asian (Shynora)
Supply and fix modular socket , 15 A -2/3 pin combined 2 module. MAKE :- Anchor/Crabtree/Havells /Indo Asian (Shynora)
Supply and fix modular fan step regulator 120 W-2 module.
Supply and fix PVC insulated and overall PVC sheathed circular flexible 3 core 4 sqmm copper conductor cable including disconnecting and removal of old cable .
Supply and fix PVC flexible pipe connection suitable size with brass chromium plated coupling nut and PVC washers on both ends complete including removal of old ones
ONKAR ELECTRIC AND GENERAL STORE
metro electrical services
ASHWAMEDH ENGINEERS
M/S. Niksun Electro-Infra Private Limited
M/S. OM ENTERPRISES
SHREE VAIBHAV ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .