| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 CrAccepted-AOC N A | ₹7.9 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹8.1 Cr+₹23.6 L (2.99%)Rejected-Finance 20 SC BOSE COLONY GALL NO 2 DEFENCE LAB ROAD RATNADA JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹8.1 Cr+₹23.6 L (2.99%) | L2 | Rejected-Finance Not lowest |
| 3 | L3₹9.9 Cr+₹2.0 Cr (25.9%)Rejected-Finance 8 51 PLOT NO 6 LIC COLONY SUJATA NAGAR PENDURTHY MANDAL VISAKHAPATNAM 530042 AP | 530042 | ₹9.9 Cr+₹2.0 Cr (25.9%) | L3 | Rejected-Finance Not lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not fulfills NIT Criteria |
| 5 | Rejected-Technical HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | - | - | Rejected-Technical Not fulfills NIT criteraia |
| Sl No | Description | Qty | Unit | SKYLIGHT INNOVATIONS L1 | M K ENGINEERS CO. L2 | LEOENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 0.00NOTE (Applicable for all items):- The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE 'A' | ||||||
| 1.00 | Design, Supply, Installation, Testing and commissioning including comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 15 Kw (Minimum 18 KWp) (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications complete all as specified and directed.
Note: Contractor shall also ensure the following:- (i) Annual maintenance contract for 5 Years complete all as specified and directed. (ii) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer. (iii) Repairing of all installation if required will be carried out on site or at service centre. Quoted rates shall be inclusive and includes for required spares, services, labour, handling and transportation charges etc.. (iv) The Engineer/Electrician shall submit reports in soft copy format as required by the Engineer in Charge. (v) Security of all SPV equipment’s shall be complete responsibilities of Station Authorities. | 1 | EACH JOB | 9,90,000 ₹9,90,000 Lowest | 10,80,000 ₹10,80,000 | 12,47,942 ₹12,47,942 |
| 2.00 | Design, Supply, Installation, Testing and commissioning including comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 20 Kw (Minimum 24 KWp) (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications complete all as specified and directed. Note: Contractor shall also ensure the following:- (i) Annual maintenance contract for 5 Years complete all as specified and directed. (ii) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer. (iii) Repairing of all installation if required will be carried out on site or at service centre. Quoted rates shall be inclusive and includes for required spares, services, labour, handling and transportation charges etc.. (iv) The Engineer/Electrician shall submit reports in soft copy format as required by the Engineer in Charge. (v) Security of all SPV equipment’s shall be complete responsibilities of Station Authorities. | 3 | EACH JOB | 13,20,000 ₹39,60,000 Lowest | 14,40,000 ₹43,20,000 | 16,63,923 ₹49,91,769 |
| 3.00 | Design, Supply, Installation, Testing and commissioning including comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 30 Kw (Minimum 36 KWp) (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications complete all as specified and directed. Note: Contractor shall also ensure the following:- (i) Annual maintenance contract for 5 Years complete all as specified and directed. (ii) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer. (iii) Repairing of all installation if required will be carried out on site or at service centre. Quoted rates shall be inclusive and includes for required spares, services, labour, handling and transportation charges etc.. (iv) The Engineer/Electrician shall submit reports in soft copy format as required by the Engineer in Charge. (v) Security of all SPV equipment’s shall be complete responsibilities of Station Authorities. | 4 | EACH JOB | 19,80,000 ₹79,20,000 Lowest | 20,88,000 ₹83,52,000 | 24,95,885 ₹99,83,540 |
| 4.00 | Design, Supply, Installation, Testing and commissioning including comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 35 Kw (Minimum 46 KWp) (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications complete all as specified and directed. Note: Contractor shall also ensure the following:- (i) Annual maintenance contract for 5 Years complete all as specified and directed. (ii) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer. (iii) Repairing of all installation if required will be carried out on site or at service centre. Quoted rates shall be inclusive and includes for required spares, services, labour, handling and transportation charges etc.. (iv) The Engineer/Electrician shall submit reports in soft copy format as required by the Engineer in Charge. (v) Security of all SPV equipment’s shall be complete responsibilities of Station Authorities. | 2 | EACH JOB | 25,30,000 ₹50,60,000 Lowest | 26,22,000 ₹52,44,000 | 31,50,000 ₹63,00,000 |
| 5.00 | Design, Supply, Installation, Testing and commissioning including comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 40 Kw (Minimum 48 KWp) (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications complete all as specified and directed. Note: Contractor shall also ensure the following:- (i) Annual maintenance contract for 5 Years complete all as specified and directed. (ii) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer. (iii) Repairing of all installation if required will be carried out on site or at service centre. Quoted rates shall be inclusive and includes for required spares, services, labour, handling and transportation charges etc.. (iv) The Engineer/Electrician shall submit reports in soft copy format as required by the Engineer in Charge. (v) Security of all SPV equipment’s shall be complete responsibilities of Station Authorities. | 5 | EACH JOB | 26,40,000 ₹1,32,00,000 Lowest | 27,36,000 ₹1,36,80,000 | 31,23,000 ₹1,56,15,000 |
| 6.00 | Design, Supply, Installation, Testing and commissioning including comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 45 Kw (Minimum 54 KWp) (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications complete all as specified and directed. Note: Contractor shall also ensure the following:- (i) Annual maintenance contract for 5 Years complete all as specified and directed. (ii) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer. (iii) Repairing of all installation if required will be carried out on site or at service centre. Quoted rates shall be inclusive and includes for required spares, services, labour, handling and transportation charges etc.. (iv) The Engineer/Electrician shall submit reports in soft copy format as required by the Engineer in Charge. (v) Security of all SPV equipment’s shall be complete responsibilities of Station Authorities. | 2 | EACH JOB | 29,70,000 ₹59,40,000 Lowest | 30,24,000 ₹60,48,000 | 37,43,827 ₹74,87,654 |
| 7.00 | Design, Supply, Installation, Testing and commissioning including comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 50 Kw (Minimum 60 KWp) (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications complete all as specified and directed. Note: Contractor shall also ensure the following:- (i) Annual maintenance contract for 5 Years complete all as specified and directed. (ii) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer. (iii) Repairing of all installation if required will be carried out on site or at service centre. Quoted rates shall be inclusive and includes for required spares, services, labour, handling and transportation charges etc.. (iv) The Engineer/Electrician shall submit reports in soft copy format as required by the Engineer in Charge. (v) Security of all SPV equipment’s shall be complete responsibilities of Station Authorities. | 1 | EACH JOB | 33,00,000 ₹33,00,000 Lowest | 33,60,000 ₹33,60,000 | 41,59,808 ₹41,59,808 |
| 8.00 | Design, Supply, Installation, Testing and commissioning including comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 70 Kw (Minimum 84 KWp) (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications complete all as specified and directed. Note: Contractor shall also ensure the following:- (i) Annual maintenance contract for 5 Years complete all as specified and directed. (ii) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer. (iii) Repairing of all installation if required will be carried out on site or at service centre. Quoted rates shall be inclusive and includes for required spares, services, labour, handling and transportation charges etc.. (iv) The Engineer/Electrician shall submit reports in soft copy format as required by the Engineer in Charge. (v) Security of all SPV equipment’s shall be complete responsibilities of Station Authorities. | 6 | EACH JOB | 46,20,000 ₹2,77,20,000 Lowest | 46,20,000 ₹2,77,20,000 Lowest | 54,44,444 ₹3,26,66,664 |
| 9.00 | Design, Supply, Installation, Testing and commissioning including comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 75 Kw (Minimum 90 KWp) (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications complete all as specified and directed. Note: Contractor shall also ensure the following:- (i) Annual maintenance contract for 5 Years complete all as specified and directed. (ii) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer. (iii) Repairing of all installation if required will be carried out on site or at service centre. Quoted rates shall be inclusive and includes for required spares, services, labour, handling and transportation charges etc.. (iv) The Engineer/Electrician shall submit reports in soft copy format as required by the Engineer in Charge. (v) Security of all SPV equipment’s shall be complete responsibilities of Station Authorities. | 1 | EACH JOB | 49,50,000 ₹49,50,000 Lowest | 49,50,000 ₹49,50,000 Lowest | 62,39,712 ₹62,39,712 |
Tender Value
₹7.3 Cr
EMD Value
₹6.9 L
Closing Date
9 Jun 2025, 6:00 pmClosed
CE SHILLONG ZONE
HQ CE SHILLONG ZONE, SPREAD EAGLE FALLS, MES COMPLEX, SHILLONG, MEGHALAYA
PROVISION OF ROOF TOP SOLAR PLANTS TOTALLING 1100 KW AT CERTAIN BLDGS AT RANGAPAHAR MIL STN UNDER GE 868 EWS
2025_MES_705457_1
89832/RANG
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Rangapahar
All as per tender document
2 documents required · 2 mandatory
₹3,000
GE 868 EWS
₹6.9 L
Yes
8 Oct 2025
25 Apr 2025
11 Jun 2025
25 Apr 2025
9 Jun 2025
26 May 2025
Amount
NOTE (Applicable for all items):- The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE 'A'
Design, Supply, Installation, Testing and commissioning including comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 15 Kw (Minimum 18 KWp) (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications complete all as specified and directed. Note: Contractor shall also ensure the following:- (i) Annual maintenance contract for 5 Years complete all as specified and directed. (ii) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer. (iii) Repairing of all installation if required will be carried out on site or at service centre. Quoted rates shall be inclusive and includes for required spares, services, labour, handling and transportation charges etc.. (iv) The Engineer/Electrician shall submit reports in soft copy format as required by the Engineer in Charge. (v) Security of all SPV equipment’s shall be complete responsibilities of Station Authorities.
Design, Supply, Installation, Testing and commissioning including comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 20 Kw (Minimum 24 KWp) (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications complete all as specified and directed. Note: Contractor shall also ensure the following:- (i) Annual maintenance contract for 5 Years complete all as specified and directed. (ii) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer. (iii) Repairing of all installation if required will be carried out on site or at service centre. Quoted rates shall be inclusive and includes for required spares, services, labour, handling and transportation charges etc.. (iv) The Engineer/Electrician shall submit reports in soft copy format as required by the Engineer in Charge. (v) Security of all SPV equipment’s shall be complete responsibilities of Station Authorities.
Design, Supply, Installation, Testing and commissioning including comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 30 Kw (Minimum 36 KWp) (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications complete all as specified and directed. Note: Contractor shall also ensure the following:- (i) Annual maintenance contract for 5 Years complete all as specified and directed. (ii) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer. (iii) Repairing of all installation if required will be carried out on site or at service centre. Quoted rates shall be inclusive and includes for required spares, services, labour, handling and transportation charges etc.. (iv) The Engineer/Electrician shall submit reports in soft copy format as required by the Engineer in Charge. (v) Security of all SPV equipment’s shall be complete responsibilities of Station Authorities.
Design, Supply, Installation, Testing and commissioning including comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 35 Kw (Minimum 46 KWp) (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications complete all as specified and directed. Note: Contractor shall also ensure the following:- (i) Annual maintenance contract for 5 Years complete all as specified and directed. (ii) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer. (iii) Repairing of all installation if required will be carried out on site or at service centre. Quoted rates shall be inclusive and includes for required spares, services, labour, handling and transportation charges etc.. (iv) The Engineer/Electrician shall submit reports in soft copy format as required by the Engineer in Charge. (v) Security of all SPV equipment’s shall be complete responsibilities of Station Authorities.
Design, Supply, Installation, Testing and commissioning including comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 40 Kw (Minimum 48 KWp) (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications complete all as specified and directed. Note: Contractor shall also ensure the following:- (i) Annual maintenance contract for 5 Years complete all as specified and directed. (ii) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer. (iii) Repairing of all installation if required will be carried out on site or at service centre. Quoted rates shall be inclusive and includes for required spares, services, labour, handling and transportation charges etc.. (iv) The Engineer/Electrician shall submit reports in soft copy format as required by the Engineer in Charge. (v) Security of all SPV equipment’s shall be complete responsibilities of Station Authorities.
Design, Supply, Installation, Testing and commissioning including comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 45 Kw (Minimum 54 KWp) (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications complete all as specified and directed. Note: Contractor shall also ensure the following:- (i) Annual maintenance contract for 5 Years complete all as specified and directed. (ii) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer. (iii) Repairing of all installation if required will be carried out on site or at service centre. Quoted rates shall be inclusive and includes for required spares, services, labour, handling and transportation charges etc.. (iv) The Engineer/Electrician shall submit reports in soft copy format as required by the Engineer in Charge. (v) Security of all SPV equipment’s shall be complete responsibilities of Station Authorities.
Design, Supply, Installation, Testing and commissioning including comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 50 Kw (Minimum 60 KWp) (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications complete all as specified and directed. Note: Contractor shall also ensure the following:- (i) Annual maintenance contract for 5 Years complete all as specified and directed. (ii) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer. (iii) Repairing of all installation if required will be carried out on site or at service centre. Quoted rates shall be inclusive and includes for required spares, services, labour, handling and transportation charges etc.. (iv) The Engineer/Electrician shall submit reports in soft copy format as required by the Engineer in Charge. (v) Security of all SPV equipment’s shall be complete responsibilities of Station Authorities.
Design, Supply, Installation, Testing and commissioning including comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 70 Kw (Minimum 84 KWp) (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications complete all as specified and directed. Note: Contractor shall also ensure the following:- (i) Annual maintenance contract for 5 Years complete all as specified and directed. (ii) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer. (iii) Repairing of all installation if required will be carried out on site or at service centre. Quoted rates shall be inclusive and includes for required spares, services, labour, handling and transportation charges etc.. (iv) The Engineer/Electrician shall submit reports in soft copy format as required by the Engineer in Charge. (v) Security of all SPV equipment’s shall be complete responsibilities of Station Authorities.
Design, Supply, Installation, Testing and commissioning including comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 75 Kw (Minimum 90 KWp) (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes, lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications complete all as specified and directed. Note: Contractor shall also ensure the following:- (i) Annual maintenance contract for 5 Years complete all as specified and directed. (ii) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer. (iii) Repairing of all installation if required will be carried out on site or at service centre. Quoted rates shall be inclusive and includes for required spares, services, labour, handling and transportation charges etc.. (iv) The Engineer/Electrician shall submit reports in soft copy format as required by the Engineer in Charge. (v) Security of all SPV equipment’s shall be complete responsibilities of Station Authorities.
Supply, laying/fixing GI tubing medium grade with all fitting in trenches or fixed to walls, ceilings or laid in floors complete all as specified and directed for 20mm bore.
Supply, laying/fixing GI tubing medium grade with all fitting in trenches or fixed to walls, ceilings or laid in floors complete all as specified and directed for 25mm bore.
Supply, laying/fixing GI tubing medium grade with all fitting in trenches or fixed to walls, ceilings or laid in floors complete all as specified and directed for 40mm bore.
S & F rotational moulded poly-ethylene water storage tanks of cap 1000 Ltrs (cylindrical vertical with closed top) hoisted and fixed in position complete specified in SSR Part I complete all as specified .
S & F rotational moulded poly-ethylene water storage tanks of cap 500 Ltrs (cylindrical vertical with closed top) hoisted and fixed in position complete specified in SSR Part I complete all as specified .
S & F Ball valves 20mm high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0mm-210gms./ 25mm-455gms/ 40mm - 690 gms) all as specified and directed.
S & F Gun-metal, 20mm globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F Gun-metal, 40mm globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
M & L Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm 125gms).
M&L for cutting of existing road/cement concrete/bituminous road of size not less than 0.6m for laying of GI/CI/DI pipe & LT cable making good to the disturbed surface by providing PCC or Same material after laying of pipe line and returning filling of soil complete all as specified and directed.
M& L for Cutting existing steel 20mm tubing for alterations or additions (Each cut measured) all specified and directed.
M& L for Cutting existing steel 40/50 mm tubing for alterations or additions (Each cut measured) all specified and directed.
Excavation in trenches n exc 1.5 mtr wide and n exc 1.5m in depth for laying of water supply pipe line etc n exc 10 Sqm on plan and getting out soft/loose soil. Note :- Excavation to be done through manual only due to site condition all as specified and directed.
Returning filling in includinguding spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10q mm 4core all as specified and directed
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4core all as specified and directed
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4core all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core all as specified and directed.
Supply and spread sand for sand cushioning of cables in trenches all as specified in MES Schedule Part-I and all as directed. Note: Punned thickness only will be measured and paid.
Supply and lay in trenches, old burnt sub class 'B' bricks as specified and all as directed.
M&L for earthing with steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and directed by Engr-In-Charge.
Earth continuity conductor or main earthing strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32X6mm dia galvanised iron strip complete all as specified and directed.
Supply and lay GI tubing 50 mm bore, light grade, galvanised, ISI marked with all specials for cable protection on road crossing/floor etc duly sealed at both ends after all as specified and directed.
Supply and lay GI tubing 100 mm bore, light grade, galvanised, ISI marked with all specials for cable protection on road crossing/floor etc duly sealed at both ends after all as specified and directed.
Supplying and fixing smart three phase four wire dual source prepaid energy meters BIS 15884 marked in existing meter board/ floor panels with pre payment capcity touch keybpad based digital having current range 10-100 Amp 415 volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC in built feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG capable to define for tariff slabs, happy hours and holiday definition.
Addition / alteration of existing LT panels with bus bar with suitable size / capacity matching with the existing busbar of LT panel board for positioning the new LT cables for roof top solar along with complete glands, lugs and nut and bolts suitable size of cable all as specified and directed.
M K ENGINEERS CO. (BID ID -3317864)
LEOENTERPRISES (BID ID -3310868)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ.xls
BOQ • 0.33 MB
Tenderdocument.pdf
Tender Documents • 3.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .