| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC | ₹23.2 L Quoted ₹23.9 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹24.4 L+₹47,544 (1.99%)Rejected-Finance INDEX NO D 1478 CE SC PUNE PLOT NO 44 11 KACHNAYAKANHALLI VILLAGE JIGANI HOBLI ANEKAL TALUK BANGALORE PIN 560 106 KARNATAKA STATE | 560106 | ₹24.4 L+₹47,544 (1.99%) | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹25.0 L+₹1.1 L (4.39%)Rejected-Finance | ₹25.0 L+₹1.1 L (4.39%) | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹26.9 L+₹2.9 L (12.2%)Rejected-Finance | ₹26.9 L+₹2.9 L (12.2%) | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹28.1 L+₹4.2 L (17.5%)Rejected-Finance 1273 CUTINO ROAD KARWAR 581301 | KARWAR | UTTARA KANNADA | KARNATAKA | 581301 | ₹28.1 L+₹4.2 L (17.5%) | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹40.0 L
EMD Value
₹79,980
Closing Date
18 Nov 2024, 6:00 pmClosed
GE (SB) KARWAR
GE (SB) KARWAR
REPAIR AND MAINTENANCE OF LT DISTRIBUTION NETWORK INCLUDING LT PANELS/FEEDER PILLAR BOXES AND ALLIED WORKS AT SAILORS RESIDENTIAL AREA,CORE AREA AND ASSOCIATED AREAS AT NAVAL BASE KARWAR UNDER GE(SB) KARWAR
2024_MES_681298_1
8248/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (SB) KARWAR
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (SB) KARWAR
₹79,980
Yes
20 Jan 2025
25 Oct 2024
20 Nov 2024
25 Oct 2024
18 Nov 2024
11 Nov 2024
25 Oct 2024 - 8 Nov 2024
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and not exceeding 1.5m for laying of LT under ground cables/GI pipes getting out as in soft /loose soil complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layer not exceeding 25 cm in soft/loose soil all as specified and directed.
Removing excavated material/soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
Supply & filling sand cushioning to under ground cable 8 cm before laying the electric cable and 15 cm after laying the cable complete all as specified considering as per SSR 1991 of part -I Note: Only punned thickness of the sand will be meausured.
Supplying and laying unreinforced precast concrete cable cover, class LV Type-1, flat size 250mm x 150mm x 40mm with ISI mark factory made complete all as specified and directed.
Taking down carefully old unserviceable UG cable of any size from the trenches/wall/pole and keeping aside for reuse and remove the unservicable cable from site after affording credit depending on its serviceability state including removal of brick/PCC cable cover complete all as specified and directed.
Supply and Laying LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete including taking out old unserviceable cable for 25 sqmm 4 core. Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule Note: [iI] Old retrived LT cable found in serviceable condition from taking out shall be re-use/relay in the work
All as per Item No.07 here-in-before but for 35 sqmm 3.5 core complete all as specified and directed
All as per Item No.07 here-in-before but for 50 Sqmm 3.50 core complete all as specified and directed.
All as per Item No.07 here-in-before but for 70 sqmm 3.50 core complete all as specified and directed
All as per Item No.07 here-in-before but for 95 sqmm 3.50 core complete all as specified and directed
All as per Item No.07 here-in-before but for 120 sqmm 3.50 core complete all as specified and directed
All as per Item No.07 here-in-before but for 185 sqmm 3.50 core complete all as specified and directed
All as per Item No.07 here-in-before but for 240 sqmm 3.50 core complete all as specified and directed
M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 25 to 35 sq.mm. Make :- M-SEAL / BIRLA 3 M LTD / RAY CHEM Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule
All as per Item No.15 herein before but for cable of size 3.5 core 50 sq.mm complete all as specified and directed.
All as per Item No. 15 herein before but for cable of size 3.5 core 70 sq.mm complete all as specified and directed.
All as per Item No.15 here-in-before but for 3.50 core cable 95 Sq mm complete all as specified and directed.
All as per Item No.15 here-in-before but for 3.50 core cable 120 to 150 Sq mm complete all as specified and directed.
All as per Item No.15 herein before but for cable of size 3.5 core 185 sq.mm complete all as specified and directed.
All as per Item No. 15 herein before but for cable of size 3.5 core 240 sq.mm complete all as specified and directed.
All as per Item No.15 here-in-before but for 3.50 core cable 300 Sq mm complete all as specified and directed.
M/L for MCCB 3 pole, 415 volts ,25 to100 Amps with breaking capacity 16 KA,with thermal magnetic release, with adjustable setting 80% to 100%, Ics=100% ICU, fixing to the existing panel board matching with the existing slots, including any alteration required and with extention links properly connected to the busbar, including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity.
All as per Item No.23 herein above but for 125 Amps with breaking capacity 16 KA complete all as specified and directed.
All as per Item No.23 herein above but for 160 Amps with breaking capacity 25 KA complete all as specified and directed.
All as per Item No.23 herein above but for 200 Amps with breaking capacity 25 KA complete all as specified and directed.
All as per Item No.23 herein above but for 250 Amps with breaking capacity 36 KA complete all as specified and directed.
All as per Item No.23 herein above but for 350 Amps with breaking capacity 36 KA complete all as specified and directed.
All as per Item No.23 herein above but for 400 Amps with breaking capacity 36 KA complete all as specified and directed.
All as per Item No.23 herein above but for 630 Amps with breaking capacity 50 KA complete all as specified and directed.
M/L for MCCB 4 pole, 415 volts ,100 Amps with breaking capacity 16 KA,with thermal magnetic release, with adjustable setting 80% to 100%, Ics=100% ICU, fixing to the existing panel board matching with the existing slots, including any alteration required and with extention links properly connected to the busbar, including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity.
All as per Item No.31 herein above but for 125 Amps with breaking capacity 16 KA complete all as specified and directed.
All as per Item No.31 herein above but for 160 Amps with breaking capacity 25 KA complete all as specified and directed.
All as per Item No.31 herein above but for 200 Amps with breaking capacity 25 KA complete all as specified and directed.
All as per Item No.31 herein above but for 250 Amps with breaking capacity 36 KA
All as per Item No.31 herein above but for 350 Amps with breaking capacity 36 KA complete all as specified and directed.
All as per Item No.31 herein above but for 400 Amps with breaking capacity 36 KA complete all as specified and directed.
All as per Item No.31 herein above but for 630 Amps with breaking capacity 50 KA complete all as specified and directed.
M&L for servicing to indoor/outdoor LT panel board, opening up all cubical doors, cleaning with air blower, removing the burnt out unserviceable instruments, copper wiring kit, and burnt out unserviceable extended copper terminals/ copper cable and replacing with new copper extended terminal bus bar with suitable size along with required nut bolt, washers, and replacing the measuring instruments like Ammeter with existing size of the CT, Volt meter, indicating lamps of LED type 'R Y B' cleaning with CTC to serviceable parts like MCCB's, all terminals, replacement of damaged aluminum lugs any description of LT U/G cables in coming and out going, replacement of deterioated copper wiring with suitable copper conductor with circuit indicator replacement of sheared rubber beadings to door of panels, including preparing the existing surface for spray painting to powder coated surface with two coat of synthetic enameled paint of approved colour, marking of incoming and out going feeder with fluorecent stickers incl preparation of the surface of panel complete all as specified and directed.
Supply only the following items :- Volt meter digital type 0-500 Volts
Ammeter digital type suitable to 0 - 100 Amps
Aluminum lugs suitable for 25 sqmm to 50 sqmm cables
Aluminum lugs suitable for 70 sqmm to 150 sqmm cables
Aluminum lugs suitable for 150 to 300 sqmm cables
Sheared rubber gasket suitable to LT panel board any description
Indicator lamp LED type 'RYB'
M&L for GI tubing 'Light' grade 50 mm bore with all fittings for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area for following sizes of pipes :-
All as per Item No.47 herein above but for 80 mm bore complete all as specified and directed.
All as per Item No.47 herein above but for 100 mm bore complete all as specified and directed.
M&L for Preparation of old painted steel surfaces and applying two coats of synthetic enamel paint of approved shade on exposed surfaces of LT panel boards including writing / marking feeders all as specified and as directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth strip 32mmx6mm size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6mm earth lead protected by provision of GI medium grade pipe 40mm bore including provision 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, 15 CM alternate layer of charcoal and salt around all sides of earth plate with fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
Supplying and fixing 32mm X 6mm ,GI earth strip all as specified and directed. Note:- Above quoted rate incl all the cutting/drilling jobs required for joining the earth strip with existing earth strip/test point incl nuts and bolts for the lap joints.
Laying only in repair LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete including taking out old unserviceable cable for 25 sqmm 4 core. Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule [ii] If old LT UG cable will found serviceable to be relaying the same.
All as per Item No.53 here-in-before but for 35 sqmm 3.5 core complete all as specified and directed.
All as per Item No.53 here-in-before but for 50 Sqmm 3.50 core complete all as specified and directed.
All as per Item No.53 here-in-before but for 70 sqmm 3.50 core complete all as specified and directed.
All as per Item No.53 here-in-before but for 95 sqmm 3.50 core complete all as specified and directed.
All as per Item No.53 here-in-before but for 120 sqmm 3.50 core complete all as specified and directed.
All as per Item No.53 here-in-before but for 185 sqmm 3.50 core complete all as specified and directed.
All as per Item No.53 here-in-before but for 240 sqmm 3.50 core complete all as specified and directed.
S&F DWC high density polyethylene pipes having 63/50 mm dia with all fittings/coupler/connecting accessories cnfirming to IS : 16098 Part-02 and IS: 16025 Part -24 for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area complete all as specified and directed.
S&F DWC high density polyethylene pipes having 90/76 mm dia with all fittings/coupler/connecting accessories cnfirming to IS : 16098 Part-02 and IS: 16025 Part -24 for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area complete all as specified and directed.
Servicing of Automatic Power Factor Correction (APFC) panel of the Capacity 300 KVAR complete comprising any type capacitors, APFC relay, MCCB, Cooling Fan, Voltmeter, Ammeter, CTs with all other connected accessories, checking of serviceability of each component, cleaning all contatct points, tightening of all connections including replacement of unserviceable components, thimbles, nut bolt and washers, etc if necessary, cleaning the entire panel by using hot blower complete all as directed by Engineer-in-Charge.
All as per item No. 63 here-in-before but capacity 180 KVAR complete all as specified and directed.
Servicing, Inspecting, checking, cleaning by using of blower,Lubrication ,greasing and carrying out preventive maintanance of ACB and ACB in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge.
Excavation of existing cable of size 25 Sq mm to 150 Sq mm removing from its loop of length 3m to 5m, cleaning, cutting of old termination and reconnecting the same along with termination at ends with suitable new aluminium lugs and refilling of cable trench with existing sand and bricks complete all as directed. Note: The rate quoted shall include for necessary earth work
Excavation of existing cable of size 185 Sq mm to 300 Sq mm removing from its loop of length 3m to 5m, cleaning, cutting of old termination and reconnecting the same along with termination at ends with suitable new aluminium lugs and refilling of cable trench with existing sand and bricks complete all as directed. Note: The rate quoted shall include for necessary earth work
Disconnecting, dismantling of existing LT Busbar Junction Box and supply, fabricate, install with new cable gland and lugs on existing cable, testing and commissioning of Busbar Junction Box of suitable size, out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on MS angle iron 50x50x6 MM size , legs not less than 750 mm height, suitable foundation of 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including oriental bus bar of aluminium strip 600 amps for three phase 4 wire including the following accessories and fitted in : -(a) Incoming: (i) MCCB high breaking capacity 4 pole 415 volt 25 KA breaking cap adjustable thermal release range 250 amp of Make:HPL/C&S/Schneider/L&T/ Indoasian/GE/Havells – 01 No (ii) Digital type Volt meter & amps meter with suitable capacity of CTs,LED indicator lamp and other connecting accessoris all as directed by the Engr In Charge.
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
BRO TECH ELECTRICAL & ENGINEERING SOLUTION (BID ID -3167600)
MARUTI AUTO MOBILE ENGINEERING (BID ID -3167385)
JAI SHREE GOPAL ELECTRICALS (BID ID -3168881)
M/S VERNEKAR AGENCIES (BID ID -3168764)
HARSHITA MARINE SERVICES (BID ID -3167630)
M/S MANOJKUMAR M NAGARKATTE (BID ID -3166588)
K.G.SHANKER (BID ID -3167890)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .