Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.0 LAccepted-Finance | ₹42.0 L | L1 | Accepted-Finance ok |
| 2 | L2₹43.5 LRejected-Finance | ₹43.5 L | L2 | Rejected-Finance ok |
| 3 | L3₹45.5 LRejected-Finance | ₹45.5 L | L3 | Rejected-Finance ok |
| 4 | L4₹50.8 LRejected-Finance GU 581 O DD NAGAR GWALIOR M P | GWALIOR | MADHYA PRADESH | ₹50.8 L | L4 | Rejected-Finance ok |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
26 Feb 2026, 12:00 pmClosed
Shri Rajkumar Rajalwal
ee stc dhar
Erection of Estimate of New 33 11 KV Sub Station Village Saitalishpura Bedwapura for low voltage Problem at the tail end of Jamniya Irr feeder under Bagdi Dc of O M Division Dhar IN Dhar Circle
2026_MPPKV_483845_1
EE(STC)/Dhar/25-26/TS-37
Open Tender
Electrical Works
90 days
EE STC DHAR
as per tender document
3 documents required · 3 mandatory
₹1,000
₹40,000
EE STC DHAR
7 Apr 2026
19 Feb 2026
27 Feb 2026
19 Feb 2026
26 Feb 2026
19 Feb 2026
19 Feb 2026 - 25 Feb 2026
23 Feb 2026
Material Supply by Contractor
Concreting of for poles @ 0.3 cmt. for pole (Including muffing)
M.S.Nuts and Bolts
11 KV, 5KN PIN COMPOSITE POLYMER INSULATOR
33 KV STRAIN (T&C TYPE) HARDWARE FITTINGS
33 KV,10 KN PIN COMPOSITE POLYMER INSULATOR
33 KV , 45 KN 16mm FRP with 25mm per KV Creepage DISC POLYMER LONG ROD TYPE T&C INSULATOR (FOR 11KV SIDE)
Supply of PTR Foundation as per attached drawing
LED LAMP , 90 WATT (COMPLETE)
INDOOR HEAT SHRINKABLE CABLE END JOINTING KIT WITH LUGS FOR 11KV GRADE XLPE CABLE FOR 3 CORE 120 SQ MM
T CLAMP ALUMINUM FOR BUS BAR PANTHER RUN PANTHER TAP
11KV Strain hard ware fitting
11 KV (45KN) 16mm FRP with 25mm per KV creepage Disc Insulator Polymer
33 KV COMPOSITE POLYMER STRAIN SET WITH HARD WARE SUITABLE FOR PANTHER CONDUCTOR (FOR 11KV SIDE)
work execute by Contractor
For Concreting (1:3:6) 0.36 H-Beam -7/9m & RSJ 9.3 m,PCC PoleDP/TP/4P of 140 kg.8m 200Kg.9m 280Kg 0.9m,0.56 for 11m,0.60 for 13m,0.67for 15m Per Pole include muff wid Pit digging,0.3per stay(20/25)etc
Anti climbing Device (Barbed Wire) GS 2.24 mm Dia (14 SWG)
PCC POLE 140 KGS 8 MTRS LONG ( Normal Soil)
PCC POLE 140 KGS 8 MTRS LONG ( Soft Rock/ Hard Soil)
Errection of 11 KV V CROSS ARM 65X65X6 MM. ANGLE TYPE
11 KV TOP CLAMPS 65x65x6 mm ANGLE TYPE
STAY SET WITHOUT STAY WIRE 16 MM. (PAINTED) ( Normal Soil)
STAY SET WITHOUT STAY WIRE 16 MM. (PAINTED) ( Soft Rock /Hard Soil)
Danger Boards Enamalled Type 11KV
11 KV, 5KN PIN COMPOSITE POLYMER INSULATOR
PCC POLE 280 KG 9.1 MTRS -30FT- LONG ( Soft Rock /Hard Soil)
PCC POLE 280 KG 9.1 MTRS -30FT- LONG ( Normal Soil)
DC.CROSS ARMS 5` (1.5 METER) CENTRE TO CENTRE 100X50X6MM CHANNEL
STAY SET WITHOUT STAY WIRE 20 MM. (PAINTED) ( Normal Soil)
STAY SET WITHOUT STAY WIRE 20 MM. (PAINTED) ( Soft Rock /Hard Soil)
Errection Horizontal and cross bracing 5' centre
DANGER BOARD ENAMELED 33 KV
33 KV,10 KN PIN COMPOSITE POLYMER INSULATOR
33 KV , 45 KN 16mm FRP with 25mm per KV Creepage DISC POLYMER LONG ROD TYPE T&C INSULATOR (FOR 11KV SIDE)
Errrection of 33 KV 'V' CROSS ARM 1.5 MTR (5FT)- CENTRE MADE FROM 75X75X6MM ANGLE
33 KV TOP CLAMPS ANGLE TYPE
Errection of PTR Foundation as per attached drawing
Direct Curent Distribution Board (DCDB) 24 Volts Indoor floor / wall mounted comprising of 1 no. 2P/100A DC MCCB 5A Switch Fuse Unit as incommer and 8 no. 2P/40A MCCB 5A
BIS certified Energy Efficiency Level-III (Old)/Level-II (New) Convential 11/0.433KV, 100 KVA Distribution Transformer
33 KV CT OUTDOOR TYPE 200-100 / 5AMP
33 KV CT Outdoor Oil immersed type, 3 Core, 200-100/5-5-1 Amp, Class 0.5 for differential protection
33 KV CTs.(out door oil filled type) 300-150/5 Amps
11KV CT OUTDOOR TYPE 300-150 / 5-5 AMP
33 KV PT OUTDOOR TYPE SINGLE - PHASE OIL IMMERSED
11 KV SINGLE PHASE PTS OIL IMMERSED
33 KV VCB, Outdoor Porcelain clad type with complete structure and accessories
11 KV VCB, OUTDOOR PORCELAIN CLAD TYPE WITH COMPLETE STRUCTURE AND ACCESSORIES
33 KV CONTROL & RELAY PANEL WITH STATIC RELAY FOR TRANSFORMER PROTECTION
33 KV CONTROL & RELAY PANEL WITH STATIC RELAY FOR FEEDER PROTECTION
11 KV control & relay panel with static relay for transformer protection
11 KV CONTROL & RELAY PANEL WITH NUMERICAL STATIC RELAY FOR DOUBLE FEEDER PROTECTION (2F)
11 KV ISOLATOR 800 A.(TURN & TWIST TYPE)
33 KV ISOLATOR 600 A. (TURN & TWIST TYPE)
Supply of 11 KV AB Switch Polymer type 400 Amp with Complete fitting
33 KV Lightening arrestor Gapless type
9 KV Gapless type Metal oxide (10 KA) Polymer for 33/11 kv S/s type
11 KV, LA POLYMER TYPE GAPLESS /METAL OXIDE 9 KV , 5 KA LINE TYPE
Distribution Box for 100 KVA Transformer (300 A.Isolator & 6 no J type Al hook.) made of SMC
11 KV D.O. Fuse Unit Polymer type
Complete jumpering of DTR
LEAD ACID BATTERY SET 30 VOLTS 200 AH
RRRDS -BATTERY CHARGER 230 V AC INPUT 20 AMP, 30 V DC OUTPUT SOLID STATE TYPE
Errection of Earthing of Capacitor Bank as per Schedule G-6.1 (For black cotton soil)
Mesh earthing for New33/11KV Sub-station inblack cotton soil as per Schedule G-3.1
LED lamp 90 watt Complete set
AAAC Rabbit conductor 0.05 sq. inch (55 sq.mm. Al.Eq.)
XLPE CABLE 11 KV ARMOURED 3X120 SQMM
70 Sq.mm.,single core XLPE insulated un-armoured aluminium conductor cable
PVC CABLE 4 CORE UNARMOURED 16 SQMM ALUMINIUM CONDUCTOR
PVC CABLE 2 CORE ARMOURED 2.5 SQMM ALUMINIUM CONDUCTOR
COPPER CONTROL CABLE 2 CORE, 2.5 SQMM PVC UNARMOURED
COPPER CONTROL CABLE 4 CORE, 2.5 SQMM PVC UNARMOURED
COPPER CONTROL CABLE 8 CORE, 2.5 SQMM PVC UNARMORED
COPPER CONTROL CABLE 12 CORE, 2.5 SQMM PVC UNARMOURED
INDOOR HEAT SHRINKABLE CABLE END JOINTING KIT WITH LUGS FOR 11KV GRADE XLPE CABLE FOR 3 CORE 120 SQ MM
T CLAMP ALUMINUM FOR BUS BAR PANTHER RUN PANTHER TAP
H- BEAM 11 METER 152 X 152 MM 37.1 KG/METER
H- BEAM 9 METER 152 X 152 MM 37.1 KG/METER = 333.9 kg. FOR 11KV GANTRY STRUCTURE
H- BEAM 7 METER 152 X 152 MM 37.1 KG/METER = 259.7 kg. FOR 5' CENTER JUMPER SUPPORT FOR 33 & 11KV SIDE
R S JOIST 9.3 METER 175X85MM 19.6 KG/ METER
Errection D.C. CHANNEL 100X50X6MM 4.8 MTRS CENTER TO CENTER (set)
DC.CROSS ARMS 8` (2.4 METER ) CENTRE TO CENTRE 100X50X6 MM CHANNEL (set)
TRANSFORMER MOUNTING CHANNEL 100X50X6MM (set)
D.O.MOUNTING CHANNEL 75X40X6MM
ERRECTION OF HORIZONATAL & CROSS BRACING 8' CENTRE (wt of each X-BRACING-64.29 Kg (set)
11 KV (45KN) 16mm FRP with 25mm per KV creepage Disc Insulator Polymer
Stringing of Each 33 KV Bus- upper and lower including drop jumpering, jointing with clamps, incoming DP/ ME to BUS
Stringing of Each 11 KV Bus-upper and lower bus including, drop jumpering and jointing with clamps,through outgoing VCB/ ME/ DP, upto station transformer
Earthing of DTR as per schedule G-1 (for black cotton soil)Earthing of DTR as per Schedule G-1.1- A (For black cotton soil) (Using -3 no pipe)
Errection of Stringing of All 33 KV & 11 KV Jumpers - from 33 KV gartry through 33 KV VCB to PTR to 11 KV gantry through 11 KV VCB
Erection of Plinth per VCB- 33KV or 11KV [Pit digging-size(3x2x0.6) = 3.6 cu. Mtr,Base filling by Kopra in case of Black cotton soil-1.92 cmt., concreting, curing and back filling of pits
AAAC Dog conductor 0.10 sq. inch (100 sq.mm. Al.Eq.)
H-Beams 152 X 152 mm., 37.1 Kg./Mtr.-13 mtr. Long = 482.3 kg
DC.CROSS ARMS 4` (1.2 METER) CENTRE TO CENTRE 100X50X6MM. CHANNEL
Bracing / Support Angle of 65x65x6mm 1.2 Mtr (4 feet) Center DP
11 KV AB SWITCH POLYMER TYPE 400 AMP WITH COMPLETE FITTING
Power Transformer Jumper Work
CONCRETING (1:3:6) OF VCB STRUCTURES 3.5 cmt per VCB
Crane charges for Handling & installation of Power Transformer with fitting of all radiaters (ii) 33/11 KV S/S above 50 km. . from crane availablity location
Total material supply by Contractor
Total Labour
GST Amount @ 18%
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_568587.pdf
techsummary_568587.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.75 MB
3311KVNewSs47Pura.pdf
Tender Documents • 1.74 MB
BOQ_568587.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid