Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.2 L+₹1.5 L (4.88%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹32.5 L+₹2.7 L (9.17%)Rejected-AOC 82 62 ROHILKHAND ELECTRICALS AND FABRICATORS GURU GOVIND SINGH MARG LALKUAN LUCKNOW UTTAR PRADESH 226001 | LUCKNOW | UTTAR PRADESH | 226001 | L3 | Rejected-AOC L3 | |
| 4 | Not Admitted-Fee/PreQual/Technical PLOT 13 SHAKTI KHAND III INDIRAPURAM GHAZIABAD 201014 | GHAZIABAD | GHAZIABAD | UTTAR PRADESH | 201014 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical OFFICE SPACE NO 3 3RD FLOOR SHREE PRATAP TOWER SEC B LDA KANPUR ROAD LUCKNOW LUCKNOW LUCKNOW UTTAR PRADESH 226012 | LUCKNOW | UTTAR PRADESH | 226012 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹28.4 L
Closing Date
2 Aug 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Director CDRI
CDRI Lucknow
Supply installation testing commissioning of 630KVA 11/0.43KV transformer for old CDRI campus, shifting of H pole along with 33KV pole mounted GO switch including associated work of 33KV switch yard and upgradation of various electrical distribut
2021_CSIR_83137_1
2/06/2021-Engg
Open Tender
Electrical Works
Item Rate
365 days
CDRI Lucknow
As per tender document
3 documents required · 3 mandatory
₹0
Exempted
25 Aug 2021
27 Jul 2021
3 Aug 2021
28 Jul 2021
2 Aug 2021
28 Jul 2021
90 days
Amount
Supply and fixing 5 amps to 32 amps. rating 240/415 volts, ‘C’ curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required.
i) Single pole
ii)Single pole and neutral
iii) Triple pole
iv)Triple pole and neutral
Supply and fixing single pole blanking plate in the existing MCB D.B. complete etc. as required.
Supply and fixing following rating, double pole, 240 V isolator in the existing MCB D.B. complete with connections, testing and commissioning etc as required.
i) 40 amps.
ii) 63 amps.
Supply and fixing following rating, four pole, 240 V isolator in the existing MCB D.B. complete with connections, testing and commissioning etc as required.
i) 40 amps.
ii) 63 amps.
Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A, 415 V “C” curve TP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
a) 12way, Double door
b) 16 way, Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
a) 4 way (4 + 12), Double door
b) 8 way (4 + 24), Double door
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
a)100 A, 16 KA,TPMCCB
b)125 A, 16 KA,TPMCCB
c)150 A, 16 KA,TPMCCB
d)200 A, 16 KA,TPMCCB
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following sizes direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required:
a)Upto 35 sq.mm
b)Above 35 sq.mm and up to 95 sq.mm
c)Above 95 sq.mm and up to 185 sq.mm
d)Above 185 sq.mm and up to 400 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
a) Upto 35 sq. mm
b) Above 35 sq. mm and upto 95 sq. mm
c) Above 95 sq. mm and upto 185 sq. mm
d) Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 K V grade of following sizes on wall surface as required:
a) Upto 35 sq.mm (clamped with 1mm thick saddle)
b) Above 35 sq.mm and up to 95 sq.mm (clamped with 25x3mm MS flat clamp)
c) Above 95 sq.mm and up to 185 sq.mm (clamped with 25/40x3mm MS flat clamp)
d) Above 185 sq.mm and up to 400 sq.mm (clamped with 40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland & heavy duty lugs for the following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grades as required:
a)3½ X 25 sq. mm (28mm)
b) 3½ X 35 sq. mm (32mm)
c) 3½ X 50 sq. mm (35 mm)
d) 3½ X 70 sq. mm (38mm)
e) 3½ X 95 sq. mm (45 mm)
f) 3½ X 120 sq. mm (45 mm)
g) 3½ X 150 sq. mm (50 mm)
h) 3½ X 185 sq. mm (57mm)
i) 3½ X 240 sq. mm (62mm)
j) 3½ X 300 sq. mm (70 mm)
k) 4 X 10 sq. mm (25 mm)
l) 4 X 16 sq. mm (28mm)
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
a) 3½ X 70 sq. mm
b) 3½ X 95 sq. mm
c) 3½ X 120 or 150 sq. mm
f) 3½ X 300 sq. mm
Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 meter.
Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering,lead up to 50 meter.
Excavation of the cable trenches in hard rock not exceeding 1.5 meter in width, and lift upto 1.5 meter, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 meter.
Providing 15 mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
Erection of metallic pole of above 4.5 metres and up to 6.5 metres length in cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 40mm nominal size) including excavation, refilling etc as required.
Dismantling of pole/street light standard / strut embedded in brick ballast foundation etc as required.
Supply of 1.1KV grade, PVC insulated and PVC sheathed heavy duty aluminium conductor cables of following sizes etc as required:
a)4 x 10mm square
b)4x 16mm square
c) 3&1/2 x 25mm square
d)3&1/2 x 35mm square
e)3&1/2 x 50mm square
f)3&1/2 x 70mm square
g) 3&1/2 x 95mm square
h) 3&1/2 x 120mm square
i) 3&1/2 x 150mm square
j) 3&1/2 x 185mm square
k) 3&1/2 x 240mm square
l) 3&1/2 x 300mm square
Dismantling of defective existing office light fixture or fan or point wiring and handing over the material to electrical section as required.
Dismantling of sub main wiring from the surface or reccessed , restoring the surface & handing over the materials to the electrical section, etc as required.
Dismantling of existing or defective old metal clad power switches, MCB enclosures, DB’s, after disconnection of cables / wires, restoring of walls and handing over the material to electrical section, etc as required.
Dismantling of various sizes of cable from the surfaces, restoring the surfaces & handing over the materials to electrical section, etc as required.
Supply & mounting of 3 or 4 pole, 63 Amps, 16KA, 415V MCCB on existing mild steel box or enclosure, etc as required.
Supply & fixing of sheet steel enclosure box for fixing of 63 or 100 or 125 or 160 or 200Amps 3 or 4 pole MCCBs etc as required.
Providing and fixing of 3mm phenolic laminated sheet/perspex sheet on existing metal board/box etc as required.
Supply & fixing of PVC junction box, 200mmx250mm in size, should have panel type locking & incorpoprating arrangement for fixing of MCB & connector, including all the consumable hardwares, etc as required.
Supply & fixing of 4 pole, double stud type bakelite terminal for connection of power cable in street light circuit, including fixing in the existing junction box or pole & connections, etc as required.
Supply & laying of 6 SWG GI earth wire along with existing aluminium power cable including end termination with proper size of lugs etc as required.
Supply & fixing of single phase, 230volt, 300mm sweep double ball bearing fitted metallic exhaust fan, etc as required.
Supply, installation, testing, commissioning of copper wound 630KVA, 11/0.43KV outdoor continous distribution transformer as per IS 1180, which includes following specifications: (1) Rating -630KVA (2) Installation-Outdoor (3) No. of phases- Three (4) Primary voltage- 11 KV (5) Secondary voltage- 0.433 KV (6) Vector group- Dyn11 (7)Taping on primary- 5% to 15% in steps of 1.25% through OFF LOAD CHANGER (8) Insulation class- A (9) Cooling -ONAN (10) Tempreture rise: In oil by thermometer-40 Degree centigrade & In winding by resistance- 45 Degree centigrade (11) Impedence- 5% IS Tolerance (12) Paint shade- RAL7032 (13) First filling of oil: Confirm to IS 335 (14) Total losses @50% loading: 2287 Watt (Max) as per IS 1180 Level-2 (15) Total losses @100% loading: 6402 Watt (Max) as per IS 1180 Level-2 (16) Terminal arrangement: HV & LV cable box.The transformer will be housed in a welded steel tank and bolted construction with the following fittings: Rating & Diagram plate, Monogram, Air release hole with plug, Detachable radiators, Bidirectional rollers, Offload tap changer, oil, Earthing terminals, Buchholz relay with alarm& trip contacts, inspection cover, Drain cum bottom filter valve, Filter valve, Oil level indicator, Pressure relief valve, Lifting lugs & Jacking pad, Silica gel dehydrating breather, Marshaling box with double instrument, Oil tempreture indicator with alarm & trip contacts, Winding tempreture indicator with alarm & trip contacts etc as required.
Supply and fixing of 33 KV suspension/disc insulator including all the accessories, hardwares and consumables etc as required.
Cutting of existing H pole with the help of hydra crane, preparation for its re-installation, including all the consumables manpower and materials etc as required.
Supply & fixing of ACSR:200square mm (PANTHER) overhead bus conductor for interconnection between H pole and making busbar, which includes all the necessary GI clamps nut, bolts etc as required.
Dismantling of existing LA, ACSR conductors, cross arms, lowering of GO switches, trimming of GI pipe associated with GO swithes, fixing of pin insulators, refixing of GO switches on top of poles, including drill holes on H poles and making of all the necessary connections for completion of circuit, which includes all the requisite materials, manpower etc as required.
Painting of 33 KV switch yard poles, fencing, transformer and all the associated equipment of the same as per existing colour, etc as required.
Buy-back of defective copper wound 750KVA, 11/0.43KV distribution transformer etc as required.
GST 12 % (already included in the items rate, please do not fill GST here)
Vaish Electricals
ROHILKHAND ELECTRICALS AND FABRICATORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .