GE of GE (SOUTH) AKHNOOR
GE SOUTH AKHNOOR C/O 56 APO PIN- 900234
REPAIR/ REPLACEMENT OF LT OH LINES, UG CABLES, LT PANELS INCLUDING OTHER CONNECTED ITEMS AT AKHNOOR UNDER GE (SOUTH) AKHNOOR.
2020_MES_325259_3
NIT-16
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SOUTH) AKHNOOR
Class E and category b(i)
8 documents required · 8 mandatory
₹500
GE SOUTH AKHNOOR
₹30,000
Yes
6 Jul 2020
23 Apr 2020
15 May 2020
23 Apr 2020
13 May 2020
1 May 2020
Amount
SCHEDULE 'A' PART-I : BOQ OF WORKS FOR E/M WORKS.
Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; not exceeding 10 Sqm on plan and getting out, in any type of soil, for laying electric cables or foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
Excavation in trenches, not exceeding 1.50 mtr wide and exceeding 1.50mtr but not exceeding 3.0mtrs in depth, not exceeding 10 Sqm on plan and getting out, in any type of soil, for laying electric cables or foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed by Engineer-In-Charge.
Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge.
Plain cement concrete M-7.50 (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10 (1:3:6), type C-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old cracked/ damaged, concrete poles with new pre-stressed concrete pole, 9.0 metres long, cross section 102mmx172mm at top and 102mmx279mm at bottom, class 10, including painting strips in black and white colour, 300mm thick, upto 1.50mtr height, from top of PCC coping with synthetic enamel paint after preparing the surface, complete all as specified and as directed by Engineer-In-Charge. Note: Excavation, earth work and concrete in foundation shall be measured and paid separately under respective items of BOQ.
Replacement of old damaged, steel tubular poles with new steel tubular swaged poles complete with mild steel base plate, finial taper plug, bolts, nuts and screws as specified, type-410, SP-31 (9.00 meters long), including painting with two coats of aluminium paint over one coat of zinc chrome primer after preparing the exposed surface and two coats of bitumiunous paint on embedded surfaces, complete all as specified and as directed by Engineer-In-Charge. Note: Excavation, earth work and concrete in foundation shall be measured and paid separately under respective items of BOQ.
Replacement of old unserviceable/ damaged over head conductor with new over head, aluminium conductor, steel reinforced, weasel, from any type/ height of poles including proper binding with existing insulators, complete all as specified and as directed by Engineer-In-Charge. Note: Weight of ACSR or all aluminium conductors drawn for overhead lines is to be determined by measuring taut horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers, etc.
Plain cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregate), as in coping of poles including necessary form work, finish even and smooth without using extra cement, complete all as specified and as directed by Engineer-In-Charge.
Re-stretching only for aluminium conductor steel reinforced including earth wire, of any size and type, maintaining required sag, fixed poles of any height and type with insulators, fixed with aluminium binding wire including all required labours, tools and plants, including making all necessary connection, complete all as specified and as directed by Engineer-In-Charge.
Taking down existing unserviceable/ rusted structural steel in cross arms and replacement with new mild steel in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat of red oxide primer, one under coat and one finishing coat of aluminium paint, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged pin type insulator with new pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged shackle type insulator with new shackle Type, Porcelain, vitreous, white, brown or green insulator size 100mm height, 115mm dia including galvanised mild steel straps 31x5mm and insulator bolts of bolts 14mm dia, washers, nuts, for working pressure 1100 volts grade, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged stay assembly with new stay assembly, galvanised iron, complete with accessories as shown in electrical plate No-1, diameter of stay rod 20mm dia, including galvanised iron stay plate 300x300x6mm, galvanised iron thimble, 14mm dia 400mm long stay bow and galvanised iron nuts bolts, washers including loop type insulator, vitreous porcelain, white, brown or green, large size, with overall dimensions 65x90mm, clearance of hole 16.0mm, including stay wire, galvanised iron, stay wire 7/4mm stranded, complete all as specified and as directed by Engineer-In-Charge. Note: Excavation, earth work and PCC shall be measured and paid separately under relevant item of Schedule ‘A’/ BOQ.
Replacement of old unserviceable/ corrosion GI earth wire with new galvanised iron wire as in earth wire or wire guard, cradles, hexagonal/ rectangular, fabricated with galvanised steel wire of 4.0mm dia from any position, LT poles of any type and any height including binding wire, 1.60mm dia, galvanised iron, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable rubber mat with new synthetic rubber insulating mat for preventing HT shock, thickness not less than 25mm, size 2.00x1.00 mtrs, complete all as specified and as directed by Engineer-In-Charge.
Supply and fixing in replacement, 1100 Volts grade, heavy duty, multi-stranded cable, PVC insulated aluminium conductor, multi-stranded, cross sectional area 10.0 Sqmm, 2-core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 50 Centimetre apart Including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and as directed by Engineer-In-Charge.
Supply and fixing in replacement, 1100 Volts grade, heavy duty, multi-stranded cable, PVC insulated aluminium conductor, multi-stranded, cross sectional area 16.0 Sqmm, 2-core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 50 Centimetre apart Including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and as directed by Engineer-In-Charge.
Preparation of surfaces of old painted pre-stressed concrete LT poles of any size, any section, cleaning the surface with mild steel wire brush and painting pole with one coat of black and white synthetic enamel paint in alternate strips, 30 cm thick each, up to 1.50 mtrs height from the top of coping including marking pole Nos with synthetic enamel paint, in uniform size black colour paint on circle with yellow paint, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged PVC separator/ spacer with new PVC separator/ spacer, polypropylene composite moulded or bolted type, including all nuts, bolts and washers, suitable for two wires on LT over head line to maintain the uniform space between the ACSR conductors, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged PVC separator/ spacer with new PVC separator/ spacer, polypropylene composite moulded or bolted type, including all nuts, bolts and washers, suitable for three wires on LT over head line to maintain the uniform space between the ACSR conductors, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged PVC separator/ spacer with new PVC separator/ spacer, polypropylene composite moulded or bolted type, including all nuts, bolts and washers, suitable for four wires on LT over head line to maintain the uniform space between the ACSR conductors, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 300.0 Sqmm, 3.50-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge.
Description all as per serial item No- 1.24 here in before but for cross-sectional area 185.0 Sqmm, 3.50-core,.
Description all as per serial item No- 1.24 here in before but for cross-sectional area 120.0 Sqmm, 3.50-core,.
Description all as per serial item No- 1.24 here in before but for cross-sectional area 95.0 Sqmm, 3.50-core,.
Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 50.0 Sqmm, 4.0-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge.
Description all as per serial item No- 1.28 here in before but for cross-sectional area 35.0 Sqmm, 4.0-core,.
Description all as per serial item No- 1.28 here in before but for cross-sectional area 25.0 Sqmm, 4.0-core,.
Description all as per serial item No- 1.28 here in before but for cross-sectional area 16.0 Sqmm, 4.0-core,.
Description all as per serial item No- 1.28 here in before but for cross-sectional area 10.0 Sqmm, 4.0-core,.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness shall be measured.
Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged GI pipe with new GI pipes/ Tubes, 'light grade', galvanised, 150mm bore, ISI marked, laid in trenches or fixed to walls/ poles including mild steel clamps, nuts, bolts and washers; for protection of electric cable, complete all as specified and as directed by Engineer-In-Charge.
Description all as serial item No- 1.35 here-in-before but for 100mm bore pipe.
Description all as serial item No- 1.35 here-in-before but for 80mm bore pipe.
Description all as serial item No- 1.35 here-in-before but for 50mm bore pipe.
Replacement of old unserviceable/ damaged MCCB with new MCCB, triple pole, 415 Volts, adjustable thermal and fixed magnetic setting, 25 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. Make: ABB cat part No- 1SDA066801R1 or equivalent in in L&T/ Legrand/ Merlin Gerin/ Siemens.
Earthing for poles, complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with galvanised iron wire of 4.0mm dia as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed. Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.
Replacement of old unserviceable/ damaged MCCB with new MCCB, triple pole, 415 Volts, adjustable thermal and fixed magnetic setting, 63 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. Make: ABB cat part No- 1SDA066805R1 or equivalent in in L&T/ Legrand/ Merlin Gerin/ Siemens.
Replacement of old unserviceable/ damaged MCCB with new MCCB, triple pole, 415 Volts, adjustable thermal and fixed magnetic setting, 100 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. Make: ABB cat part No- 1SDA066807R1 equivalent in L&T/ Legrand/ Merlin Gerin/ Siemens.
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and adjustable magnetic setting, 125 Amps with breaking capacity 25 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. Make: ABB cat part No- 1SDA067409R1 or equivalent in L&T/ Legrand/ Merlin Gerin/ Siemens.
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and adjustable magnetic setting, 160 Amps with breaking capacity 25 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. Make: ABB cat part No- 1SDA067410R1 or equivalent in L&T/ Legrand/ Merlin Gerin/ Siemens.
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and adjustable magnetic setting, 200 Amps with breaking capacity 36 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. Make: ABB cat part No- 1SDA068109R1 or equivalent in L&T/ Legrand/ Merlin Gerin/ Siemens.
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and adjustable magnetic setting, 250 Amps with breaking capacity 36 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. Make: ABB cat part No- 1SDA068111R1 or equivalent L&T/ Legrand/ Merlin Gerin/ Siemens.
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and adjustable magnetic setting, 400 Amps with breaking capacity 36 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. Make: ABB cat part No- 1SDA054478R1 or equivalent in in L&T/ Legrand/ Merlin Gerin/ Siemens.
Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and adjustable magnetic setting, 630 Amps with breaking capacity 50 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge. Make: ABB cat part No- 1SDA060211R1 or equivalent in in L&T/ Legrand/ Merlin Gerin/ Siemens.
Replacement of old unserviceable/ damaged Single Phase Preventer with new Single Phase Preventer, suitable for DOL/ star delta starter, with in-built star delta timer, complete all as specified and as directed by Engineer-In-Charge. Make:L&T cat part No- XMB81808OOOO or equivalent in Legrand/ ABB/ Merlin Gerin/ Siemens.
Replacement of old unserviceable/ damaged cable trunking with new cable trunking (casing/ caping type), galvanised steel, suitable for cable laying, size 100x70mm, complete all as specified and as directed by Engineer-In-Charge.
Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with galvanised iron strip, size 32x6mm as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge. Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.
Anti-climbing device; spikes type fabricated out of mild steel bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole, complete all as specified and as directed by Engineer-In-Charge.
Supply installation, commissioning, new LT feeder pillar box/ panel, in-replacement of old unserviceable LT panel/ feeder pillar box, complete all as specified and as directed. Note: Detailed description and accessories/ equipments shall be as mentioned on serial page No- 25 of tender (CA) here-in-after.
Supply installation, commissioning, new LT feeder pillar box/ panel, in-replacement of old unserviceable LT panel/ feeder pillar box, complete all as specified and as directed. Note: Detailed description and accessories/ equipments shall be as mentioned on serial page No- 25 of tender (CA) here-in-after.
Repairing burnt/ worn out serviceable LT cable ends by disconnecting the cable from junction box/ LT panel/ pole etc cutting out the burnt out cable ends and taking out extra cable from cable loops by digging and reconnecting as existing after providing new aluminium lugs, tapes, nuts, bolts and washers suitable for LT cable of size from 10 Sqmm to 16 Sqmm, any-core, including any site clearance, complete all as specified and as directed by Engineer-In-charge. Note: Quoted rate shall be deemed included the cost of excavation for taking out cable from loops, site clearance and cable connection, tools and plants as required for repair of cable ends.
Description all as per serial item No- 1.55 here-in-before but for aluminium cable, cross sectional area size from 25.0 Sqmm to 50.0 Sqmm, any-core.
Description all as per serial item No- 1.55 here-in-before but for aluminium cable, cross sectional area size from 70.0 Sqmm to 95.0 Sqmm, any-core.
Description all as per serial item No- 1.55 here-in-before but for aluminium cable, cross sectional area size from 120.0 Sqmm to 150.0 Sqmm, any-core.
Description all as per serial item No- 1.55 here-in-before but for aluminium cable, cross sectional area size from 185.0 Sqmm to 240.0 Sqmm, any-core.
Description all as per serial item No- 1.55 here-in-before but for aluminium cable, cross sectional area size from 240.0 Sqmm to 300.0 Sqmm, any-core.
Felling/ cutting of tree not exceeding 30cm girth including cutting of trunk, and branches along the over head LT/ HT lines/ poles, in 3.0mtrs radius all around the conductor and disposal of material to a distance not exceeding 50mtrs and clearing site including making surface even with all necessary tools, plants and manpower, complete all as specified and as directed by Engineer-In-Charge.
Cleaning away/ cutting of all grass vegetation, saplings, shrubs, creepers, brushwood, undergrowth, roots and trees not exceeding 30cm girth (measured one metre above ground level) around the LT panels, transformers, and removing rubbish outside the periphery of cantonmant area, complete all as specified and as directed by Engineer-In-Charge.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size, for LT, 20x15cm size, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
Preparation of surfaces of old painted steel tubular swaged poles LT poles of any size, any section, cleaning the surface with mild steel wire brush and painting pole with one coat of black and white synthetic enamel paint in alternate strips, 30 cm thick each, up to 1.50 mtrs height from the top of coping including marking pole Nos with synthetic enamel paint, in uniform size black colour paint on circle with yellow paint, including aluminium colour painting to cross arms, bracing, clamps, nuts, bolts etc complete all as specified and as directed by Engineer-In-Charge
Preparation of surfaces of old painted steel tubular swaged poles LT poles of any size, any section, of two pole structure, cleaning the surface with mild steel wire brush and painting pole with one coat of black and white synthetic enamel paint in alternate strips, 30 cm thick each, up to 1.50 mtrs height from the top of coping including marking pole Nos with synthetic enamel paint, in uniform size black colour paint on circle with yellow paint, including aluminium colour painting to cross arms, bracing, clamps, nuts, bolts etc complete all as specified and as directed by Engineer-In-Charge.
Preparation of surfaces of old painted steel tubular swaged poles LT poles of any size, any section, of four pole structure, cleaning the surface with mild steel wire brush and painting pole with one coat of black and white synthetic enamel paint in alternate strips, 30 cm thick each, up to 1.50 mtrs height from the top of coping including marking pole Nos with synthetic enamel paint, in uniform size black colour paint on circle with yellow paint, including aluminium colour painting to cross arms, bracing, clamps, nuts, bolts etc complete all as specified and as directed by Engineer-In-Charge.
Amount of Schedule of credit of for Rs 1,25,540.00 shall be deducted from quoted amount.
VIJAY BUILDERS
M/S SUMEET TRADING CORP
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .