Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.9 L+₹48,771 (2.98%)Rejected-AOC C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹17.9 L+₹1.5 L (9.32%)Rejected-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L3 | Rejected-AOC Other than L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
21 Jul 2020, 6:00 pmClosed
Shri TKM Rambhal, EE
GE (West) Mathura
Petty repairs to internal electrification in day to day complaints basis under GE (W) Mathura
2020_MES_353706_1
8300/939/E8
Open Tender
Civil Works
Item Rate
335 days
Mathura Cantt
As per tender documents
9 documents required · 9 mandatory
₹500
GE (West) Mathura
₹60,000
Yes
30 Jul 2020
23 Jun 2020
22 Jul 2020
23 Jun 2020
21 Jul 2020
9 Jul 2020
Amount
Attending the electrical complaints lodged by users for repairs and maintenance of E/M services complete i.e complaints of no power supply, electric supply upto fans, sockets 5 & 15 Amps, main switches, switch boards, DB's, all types Light fittings, ceiling/exhaust fans provided in the buildings (OTM/Md Accn) garden/security lights of HQ 1 Corps (Zone 'A') with skilled electrician 4 years expreience at Mathura Cantt and maintaining of all documents i.e. complaint register duly signed by user complete all as specified and directed.
Attending the electrical complaints lodged by users for repairs and maintenance of E/M services complete i.e complaints of no power supply, electric supply upto fans, sockets 5 & 15 Amps, main switches, switch boards, DB's, all type Light fittings, ceiling/exhaust fans provided in the buildings (OTM/Md Accn) garden/security lights of Hoshiyar Singh Enclave (Zone 'B') with skilled electrician 4 years expreience at Mathura Cantt and maintaining of all documents i.e. complaint register duly signed by user complete all as specified and directed. Notes for Item No Ser 1 & 2 :- (a) The persons deployed should posses good knowledge in internal electrification having 4 years exeprience in respective trade. (b) Complaints of urgent nature which effects internal electrical system to a particular area will be attended round the clock including Sunday/Holiday. (c) Complaints of normal nature will be attended within 24 hrs of complaint lodged. (d) Nature of complaints either urgent or normal shall be decided by the Engr-in-Charge. (e) If contractor fails to attend the complaints of normal nature with in 24 hrs and urgent nature within 2 hrs, he shall be lavied panelty Rs. 500/- per complaint per day. (f) Per complaint - consists 10 complaints of various natures. Contractor shall quote their rate accordingly. (g) Contractor has to deputed min 01 electrician and 01 helper at both the zone separately and should be made available round the clock. The cost to this effect is deemed to be included in quoted rate. (h) If any item required to be replaced shall be measured and paid separately as supply only items of this schedule. (j) The person deploy for attending complaint shall give his permanent mobile number to Engr-in-Charge.
Supply only CRYSTAL GLASS LED TUBE LIGHT (double side connection) ultra bright glass LED tubelight 20 Watt with very high efficiency suited for installation in existing T8 fitting with G13 lamp holders complete all as specified and directed.
Supply only 20W surface and wall mounted LED batten with LED rod 6000K extruded aluminum housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver complete all as specified and directed.
Supply only LED bulb base B22 of capacity 10 watts not less than 700 lumens output at 6500k colour temp complete all as specified and directed.
Supply only surface and wall mounted 10 watt LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver for mirror light complete all as specified and directed.
Supply only Security Light of 30 watts of ENDURA CITYLITE PLATINUM PLUS New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source with acrylic cover including driver and accessories complete all as specified and directed.
Supply only Bulk Head LED light of 10W complete all as specified and directed.
Supply only LED of 36W Watts 6000k slim panel IP40 60x60 cm LED panel for recessed dust-free installation with high brightness LEDs for glare-free homogenous illumination with all connected accessories including driver complete all as specified and directed.
Supply only factory made sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with isolated neutral bar and shrounded bus bar IP protection 43 having door earthing complete all as specified and directed.
Supply only factory made sheet metal enclosure MCB DB TPN 4 way with 200 amps rated bus bar 240 volts double door with isolated neutral bar and shrounded bus bar IP protection 43 having door earthing complete all as specified and directed
Supply only MCB DP 240 V,50 Hz 40 Amp 10 KA 'C' curve complete all as specified and directed.
Supply only MCB SPN 240 V,50 Hz 32 Amp 10 KA 'C' curve complete all as specified and directed.
Supply only MCB SPN 240 V, 50 Hz 40 - 63 Amps 10 KA 'C' curve complete all as specified and as directed.
Supply only MCB,SP,240 volts ,AC, 10 KA 'C' curve 6 - 32 Amps complete all as specified and as directed.
Supply only Angle /battan holder polycorbonate type body suitable for batten fitting complete all as specified and directed.
Supply only switch flush type of polycorbonate body, single pole, one way 6 Amp, 240 volts (ISI Marked) as per existing make complete all as specified and directed. Make : Anchor/Havells/Legrand/HPL/SSK
Supply only switch 6 Amps, single pole, Modular type, one way, 240 volts(ISI Marked) 1 Module as per existing make complete all as specified and directed. Make : Anchor/Havells/Legrand/HPL/SSK
Supply only switch flush type of single pole two way 6 Amp as per existing make complete all as specified and directed. Make : Anchor/Havells/Legrand/HPL/SSK
Supply only switch 6 Amps, single pole, Modular type, twoway, 240 volts(ISI Marked) 1 Module as per existing make complete all as specified and directed. Make : Anchor/Havells/Legrand/HPL/SSK
Supply only ceiling rose 63 x 30 mm three terminal, polycorbonate body complete all as specified and directed.
Supply only bell push, flush type 6 Amp 240 volt polycorbonate body as per existing make complete all as specified and directed. Make : Anchor/Havells/Legrand/HPL/SSK
Supply only modular bell push, 6 Amp 240 volt one module as per existing make complete all as specified and directed. Make : Anchor/Havells/Legrand/HPL/SSK
Supply only call bell ding dong AC 240 volts, single phase as per existing make complete all as specified and directed. Make : Anchor/Havells/Legrand/HPL/SSK
Supply only switch socket combination 5 pin 5 Amps flush type, 240 volts (ISI Marked) as per existing make complete all as specified and directed. Make : Anchor/Havells/Legrand/HPL/SSK
Supply only switch socket combination 5 pin 15 Amps flush type, 240 volts (ISI Marked) as per existing make complete all as specified and directed. Make : Anchor/Havells/Legrand/HPL/SSK
Supply only socket outlet 3 pin 5/6 Amps flush type polycorbonate body as per existing make complete all as specified and directed. Make : Anchor/Havells/Legrand/HPL/SSK
Supply only modular socket 6A 2/3 pin 2 module as per existing make complete all as specified and directed. Make : Anchor/Havells/Legrand/HPL/SSK
Supply only switch flush type single pole one way 16 Amp polycorbonate body as per existing make complete all as specified and directed. Make : Anchor/Havells/Legrand/HPL/SSK
Supply only Modular switch 16 Amps, single pole, Modular type, one way, 240 volts(ISI Marked) 1 Module as per existing make complete all as specified and directed. Make : Anchor/Havells/Legrand/HPL/SSK
Supply only socket outlet 2 in 1, 3 pin 5/15 Amps polycorbonate body as per existing make complete all as specified and directed. Make : Anchor/Havells/Legrand/HPL/SSK
Supply only modular socket 6A/16A 3/6 pin combined 2 module as per existing make complete all as specified and directed. Make : Anchor/Havells/Legrand/HPL/SSK
Supply only stepped type electronic fan regulator switch type as per existing make complete all as specified and directed. Make : Anchor/Havells/Legrand/HPL/SSK
Supply only twin core flexible wire of size 40/0.0076 Sqmm complete all as specified and directed.
Supply only twin core flexible wire of size 23/0.0076Sqmmcomplete all as specified and directed.
Supply only PVC insulated, FRLS, unsheathed single core, multistranded copper conductor industrial cable 1.5 Sqmmcomplete all as specified and directed.
Supply only PVC insulated, FRLS, unsheathed single core, multistranded copper conductor industrial cable 2.5 Sqmm complete all as specified and directed.
Supply only electronic 3 speed socket type fan regulator 120/280 volts of 400 watt capacity including connecting up complete all as specified and directed.
Supply only 12 W LED slim fit low profile downlights, engineered to deliver superior light output and uniformity utilising the latest edge-lit LED technology & high lumen output with all connected accessories including driver complete all as specified and directed.
Supply only 40 W suspended architectural LED luminaire provides soft light and glare free symmetrical illumination (with continuous mounting end cap) including driver complete all as specified and directed.
Supply only fan step regulator modular type 120 W, 2 Module as per existing make complete all as specified and directed. Make : Anchor/Havells/Legrand/HPL/SSK
Supply only Hylum sheet 3 mm thick of size 4" x 4" including Screws for fixing and suitable cutting for fixing switches and sockets complete all as specified and directed.
Supply only Hylum sheet 3 mm thick of size 7" x 4" including Screws for fixing and suitable cutting for fixing switches and sockets complete all as specified and directed.
Supply only Hylum sheet 3 mm thick of size 8" x 10" including Screws for fixing and suitable cutting for fixing switches and sockets complete all as specified and directed.
Supply only Hylum sheet 3 mm thick of size 11" x 5" including Screws for fixing and suitable cutting for fixing switches and sockets complete all as specified and directed.
Supply and fixing sunken Box GI 1.8 mm thick of size 4" x 4" duly painted inside and outside with one coat of red oxide primer and two coats of black bituminous paint ncluding cutting chasing and PCC work, plastering and making good the disturbed surface and match the existing by white wash/distemper complete all as directed. Make : Anchor/ Havells/SSK/ Legrand/HPL.
Supply and fixing sunken Box GI 1.8 mm thick of size 7" x 4" duly painted inside and outside with one coat of red oxide primer and two coats of black bituminous paint including cutting chasing and PCC work, plastering and making good the disturbed surface and match the existing by white wash/distemper complete all as directed. Make : Anchor/ Havells/SSK/ Legrand/HPL.
Supply and fixing sunken Box GI 1.8 mm thick of size 8" x 10" duly painted inside and outside with one coat of red oxide primer and two coats of black bituminous paint ncluding cutting chasing and PCC work, plastering and making good the disturbed surface and match the existing by white wash/distemper complete all as directed. Make : Anchor/ Havells/SSK/ Legrand/HPL.
Supply only metalic plug top suitable for 20 Amp socket outlet complete all as directed. Make : Anchor/ Havells/SSK/ Legrand/HPL.
Supply only fan capacitor 2.5 MFD 240 Volt complete all as directed.
Supply only fan capacitor 4 MFD 240 Volt complete all as directed.
S&F in replacement sheet metal enclosures with socket plug top and MCBs single pole and neutral enclosures with 2 pin and earth plug and socket complete with one SPN MCB of 20 Amp rating 240 Volt including cutting, chasing & PCC work, plastering making good the disturbed surfaces and matching with existing by white wash/distemper complete all as specified and directed. Make : Havells/Anchor/HPL/Legrand/S&C/Standard
Supply only constant current LED driver 240 Volt 50Hz suitable for 5 to 15 Watt input current 0.18A out put current 1.00A complete all as directed.
Supply only constant current LED driver 240 Volt 50Hz suitable for 16 to 25 Watt input current 0.18A out put current 1.00A complete all as directed.
Supply only constant current LED driver 240 Volt 50Hz suitable for 26 to 35 Watt input current 0.18A out put current 1.00A complete all as directed.
Supply only constant current LED driver 240 Volt 50Hz suitable for 36 to 50 Watt input current 0.18A out put current 1.00A complete all as directed.
Supply only constant current LED driver 240 Volt 50Hz suitable for 51 to 70 Watt input current 0.18A out put current 1.00A complete all as directed.
Supply and fixing in replacemnt LED chip 240 Volt 50Hz suitable for 5 to 15 Watt for LED light fitting complete all as directed.
Supply and fixing in replacemnt LED chip 240 Volt 50Hz suitable for 26 to 36 Watt for LED light fitting complete all as directed.
S&F factory made sheet metal enclosers distributed board double door three phase 415 volts 6 way for MCCB 125 Amp, 4P as incoming and MCB (TP/SP) as outgoing comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed. Note : (i) The DB shall be VTPN of Legrand or equivalent of other specified makes listed in Appendix 'B'. (ii) The DB Shall be flush fixed and making good the distrubed surface matching with existing specification shall be part of job at no extra cost. (iii) Connection of the MCCBs/ MCBs with cable shall be made through appropriate size pin / bottle type thimble-properly crimped. (iv) All the vacant holes of the DB shall be provided with blank plates of appropriate size.
S&F MCCB 160 Amps 4 pole, 415 volts, 50Hz fixed type including fixing in existing panel and its connection works with rupturing capacity 25 KA complete all as specified and directed.
S&F MCCB 200 Amps 4 pole, 415 volts, 50Hz fixed type including fixing in existing panel and its connection works with rupturing capacity 25 KA complete all as specified and directed.
S&F MCB 125 Amps, 4 pole 25KA, 'C' Curve complete all as specified and directed.
S&F MCB 100 Amps, 4 pole 25KA, 'C' Curve complete all as specified and directed.
S&F MCB TPN 240 volts, 63 Amps, 10KA, 'C' Curve complete all as specified and directed.
S&F MCB TP 240 volts,40- 63 Amps, 10KA, 'C' Curve complete all as specified and directed.
S&F in replacement MCB protected socket 4 module with 25 Amp 'C' series 240 Volt, 50 Hz MCB SP including chases wall for fixing of sheet steel enclosure and making good distributed wall surfaces to match with existing specification complete all as specified and directed.Make : Havells Cat Part No DHDMCSN0251025 or equivalent in Anchor/Legrand
Ms Kamal Kant Agarwal
shyam construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .