Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-AOC KORCHUNG SATRA RAIDANGIA P O AIBHETI P S JAJARI DIST NAGAON ASSAM | NAGAON | ASSAM | 782001 | ₹3.2 Cr | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹3.2 CrRejected-AOC DEKARBARI CITY TOWN BARPETA P O AMGURI P S SORBHOG DISTRICT BARPETA ASSAM PIN 781317 | BARPETA | ASSAM | 781317 | ₹3.2 Cr | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | M/S Royal Smart Construction L2 | Sri Ruhini Bora L1 |
|---|---|---|---|---|---|
| 1.00 | Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
Ordinary Soil
(B) Mechanical Means
(II) With dewatering
(i) Depth upto 3 m | 454.27 | cum | 81.03 ₹36,810.7 | 100 ₹45,427.2 |
| 2.00 | Bored cast-in-situ M35 grade R.C.C. Pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter-1000mm) | 448 | metre | 11,610.44 ₹52,01,479.32 | 11,000 ₹49,28,000 |
| 3.00 | Pile load test on single vertical pile in accordance with IS:2911(Part-IV).
a) Initial and Routine load test | 400 | Ton | 376.63 ₹1,50,651.6 | 300 ₹1,20,000 |
| 4.00 | Levelling course for Pile Cap | 12.15 | cum | 5,879.98 ₹71,441.73 | 6,000 ₹72,900 |
| 5.00 | Cement concrete for reinforced concrete in Pile cap complete as per drawing and Technical Specification.
B. RCC grade M- 25 ( Using concrete mixer) | 170.28 | cum | 7,543.99 ₹12,84,591.13 | 8,000 ₹13,62,240 |
| 6.00 | Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 | 64.43 | Ton | 64,185.57 ₹41,35,412.13 | 85,000 ₹54,76,465 |
| 7.00 | Providing and constructing temporary island for construction of pile foundation with depth of water upto 4.0m complete as per technical specification | 1 | each | 64,350.72 ₹64,350.72 | 50,000 ₹50,000 |
| 8.00 | Providing and constructing one span service road to reach island location from one pier location to another pier location | 22 | metre | 3,746.89 ₹82,431.53 | 3,000 ₹66,000 |
| 9.00 | Construction of cold weather Bamboo bridge overall width of 3.70m and clear road way 3m with jungle wood post 20cm to 25cm dia 5nos. In each rows and rows being 2.1m. apart except for the navigable span which should be 3m. Post to be driven at least 180cm. or more below ground level including providing 20cm to 25cm center to center and placed over 20 cm dia, jungle wood dham, 15cm dia. jungle wood bracing collar fixed by bolts and nuts, straps etc. mature bholuka Bamboo cross groth all closely packed and tied 75cm wide track way made from 38mm thick 1st class local plank fixed on 75mmx100mm first class local wood battens 120cm apart and 3 lines of jati bamboo horizantal railing fixed in bholuka bamboo post placed at 210cm apartand white washed including all necessary nuts and bolts, coir ropes, struts, nails etc. complete with a layer of brushwood to exposed portion out-side trackway with earth topping complete as per direction of the department. | 45 | metre | 13,725.38 ₹6,17,642.32 | 12,000 ₹5,40,000 |
| 10.00 | Plain/Reinforcedcement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (N) Without plasticiser
F. RCC Grade M 25
i) Height upto 5.0m , Using Concrete mixure | 147.35 | cum | 8,018.77 ₹11,81,574.34 | 8,000 ₹11,78,808 |
Tender Value
₹3.2 Cr
EMD Value
₹6.4 L
Closing Date
31 Jul 2025, 2:00 pmClosed
CE (Roads), PWRD, Assam, Chandmari, Ghy-3
O/O The CE (Roads), PWRD, Assam, Chandmari, Ghy-3
STBR/RIDF-XXXI/RUPOHIHAT-01/27 Construction of RCC Bridge No. 1/1 on Dhing Gaon to Goroimari Road under Mukhya Mantrir Unnata Paki Path Nirman Achani (MMUPPNA) under RIDF-XXXI of NABARD for the year 2025-26 in Nagaon District (Rupohihat LAC)
2025_PWD_45554_27
CE/STBR/09/NIT/RIDF-XXXI/2025 26/1 Dated 24-06-2025
Open Tender
Civil Works – Roads
545 days
Rupohihat
Please refer Tender documents.
5 documents required · 5 mandatory
₹6,413
₹6.4 L
Yes
O/O The CE (Roads), PWRD, Assam, Chandmari, Ghy-3
31 Jan 2026
17 Jul 2025
1 Aug 2025
17 Jul 2025
31 Jul 2025
17 Jul 2025
17 Jul 2025 - 31 Jul 2025
18 Jul 2025
Amount
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Ordinary Soil (B) Mechanical Means (II) With dewatering (i) Depth upto 3 m
Bored cast-in-situ M35 grade R.C.C. Pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter-1000mm)
Pile load test on single vertical pile in accordance with IS:2911(Part-IV). a) Initial and Routine load test
Levelling course for Pile Cap
Cement concrete for reinforced concrete in Pile cap complete as per drawing and Technical Specification. B. RCC grade M- 25 ( Using concrete mixer)
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
Providing and constructing temporary island for construction of pile foundation with depth of water upto 4.0m complete as per technical specification
Providing and constructing one span service road to reach island location from one pier location to another pier location
Construction of cold weather Bamboo bridge overall width of 3.70m and clear road way 3m with jungle wood post 20cm to 25cm dia 5nos. In each rows and rows being 2.1m. apart except for the navigable span which should be 3m. Post to be driven at least 180cm. or more below ground level including providing 20cm to 25cm center to center and placed over 20 cm dia, jungle wood dham, 15cm dia. jungle wood bracing collar fixed by bolts and nuts, straps etc. mature bholuka Bamboo cross groth all closely packed and tied 75cm wide track way made from 38mm thick 1st class local plank fixed on 75mmx100mm first class local wood battens 120cm apart and 3 lines of jati bamboo horizantal railing fixed in bholuka bamboo post placed at 210cm apartand white washed including all necessary nuts and bolts, coir ropes, struts, nails etc. complete with a layer of brushwood to exposed portion out-side trackway with earth topping complete as per direction of the department.
Plain/Reinforcedcement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. (N) Without plasticiser F. RCC Grade M 25 i) Height upto 5.0m , Using Concrete mixure
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. B) Sandy material
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size toeards the wall and provided over the entire surfaces behind the abutement, wing wall and return wall to the full height compacted to firm condition complete as per drawing and technical specification.
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification B) RCC M 25 (Using Concrete mixure) II) For T- Beam and Slab 1) Height iupto 5.0 m
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in superstructure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications
Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.
Providing and fixing drainage spouts as per MORT & H specifications.
Strip Seal Expansion Joint : (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation).
Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification
Carrying out Sub Soil Investigation (SSI) for all types of soil (except boring in rock) upto a depth of 30m or refusal (N-100) for each foundation location as per IRC:78-2000 and submission of SSI report to the engineer in charge for approval. Preparation & submission of Design calculation & Drawings of foundations, sub Structure , Super Structure as per relevent IRC Codes and SSI report 2 (Two) Copies each of Design & drawings of each Bridge to be submitted for approval and 8 (eight) copies after approval of competant authority.
Boulder apron laid without wire crates (Providing and laying of boulder apron on river bed for potection against scour with stone boulders weighting not less than 40Kg each.)
Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications
Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. ii. By Mechanical Means (a) In area of non-thorny jungle
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (i) Private Land
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (i) Private Land
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. III. WBM Grading 3 (A) By Manual Means: Using stone screening Type-B 11.2 mm for Gr.III
Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage. (a) Including Edge block/ Edge restraints
Furnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shown on the drawing or as directed by the Engineer including preparation of ground, fetching of sods and watering as per Technical Specification Clause 309.
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 (ii) 600mm equilateral triangle
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 (iv) 800mm x 600mm rectangular
RCC Guard Post: Supplying, fitting and fixing RCC guard post 150cm long erected 75cm above the ground and 75cm below the ground with M-15 grade (nominal mix 1:2:4 with broken stone aggregate up to 20mm size) of cement concrete and required reinforcement tied in position with annealed black wire including centering, moulding the top, curing including painting concrete surfaces in 23cm strips upto 0.75m from the top alternately in black and white and having 2 nos. reflective band of desired shade etc. complete as per design and as directed. (b) 15 cm dia. RCC guard post with reinforcement of 4nos. 12mm dia TMT main steel bars and 6mm TMT/ MS stirrups at 15cm c/c.
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications
M/S Royal Smart Construction (BID ID -274075)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid