Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61 LAccepted-AOC NEW NO 16 OLD NO 193 THIRUVASAGAM ST GANDHINAGAR MAIN ROAD EKKATTUTHANGAL CHENNAI CHENNAI TAMIL NADU 600032 | CHENNAI | TAMIL NADU | 600032 | L1 | Accepted-AOC Becomes L1 | |
| 2 | L2₹68.6 L+₹7.6 L (12.4%)Rejected-AOC | L2 | Rejected-AOC Becomes L2 | |
| 3 | L3₹84.9 L+₹23.9 L (39.2%)Rejected-AOC 2ND FLOOR 2B SORAJ ESTATE ULUBARI K C PATOWARI ROAD ULUABRI KAMRUP ASSAM 781007 | KAMRUP METRO | ASSAM | 781007 | L3 | Rejected-AOC Becomes L3 | |
| 4 | L4₹87.1 L+₹26.1 L (42.7%)Rejected-AOC | L4 | Rejected-AOC Becomes L4 |
Tender Value
₹91.8 L
EMD Value
₹1.8 L
Closing Date
10 Mar 2022, 5:00 pmClosed
AGM Electrical
IMPHAL AIRPORT
REPLACEMENT OF OLD PACKAGE AC AT SHA WITH VRF SYSTEM AT IMPHAL AIRPORT
2022_AAI_105794_1
2022_AAI_105794_1
Open Tender
Electrical Works
Works
120 days
IMPHAL
As per NIT
14 documents required · 14 mandatory
₹1,180
₹1.8 L
9 Jun 2022
17 Feb 2022
11 Mar 2022
17 Feb 2022
10 Mar 2022
17 Feb 2022
17 Feb 2022 - 4 Mar 2022
Amount
Supply, Installation, Testing and Commissioning of Modular Type Variable Refrigerant Flow Outdoor Units with hermatically sealed inverter type Scroll Compressor(s) with BLDC motor suitable to operate on 415 V ± 10%, 50 Hz, 3 Phase AC Supply, heat exchanger/condenser coil, heating & cooling, microprocessor based controller, low noise condenser fan, auto check function for connection error, auto address setting and minimum capacity as mentioned below. All outdoor unit should have stepless modulation, Top discharge type condensing units with R410 A refrigerant including full charge of refrigerant gas and oil for commissioning the entire system, vibration isolators with fixing in the existing angle iron frame work, capable of delivering 100% capacity at 40 Deg C ambient and COP not less than 3.8 & 6.0 at 100% & 50% load condition respectively for cooling conforming to AHRI Standards and Conditions, etc., as required.
28.0 HP (Comprising of Minimum Two Compressors)
Minimum 8800 CFM
Supply, Installation, Testing and Commissioning of following nominal sizes of soft/hard drawn copper refrigerant piping for VRF System with necessary jointng/brazing including, insulated with nitrile rubber, tubular sleeve sections of specified thickness as below for Suction and Liquid lines i/c providing and fixing of all accessories, vaccumization and Nitrogen testing etc., complete i/c fixing arrangements of all sizes of CU tubes on the existing GI tray.
1/2" dia (OD) (soft drawn) with tube thickness 1.2 mm with 19mm thick insulation or as per OEM standard.
3/4" dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation or as per OEM standard.
1 1/8" dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation or as per OEM standard.
1 3/8" dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation or as per OEM standard.
Supply, Installation, Testing and Commissioning of following nominal sizes of soft/hard drawn copper refrigerant piping for VRF System with necessary jointng/brazing including, insulated with nitrile rubber, tubular sleeve sections of specified thickness as below for Suction and Liquid lines i/c providing and fixing of all accessories, vaccumization and Nitrogen testing etc.,including fixing Arragements for the following copper tubes in the Ceiling/Wall including providing and fixing necessary suspenders/supports etc., complete as required.
1/2" dia (OD) (soft drawn) with tube thickness 1.2 mm with 19mm thick insulation or as per OEM standard.
3/4" dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation or as per OEM standard.
1 1/8" dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation or as per OEM standard.
1 3/8" dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation or as per OEM standard.
Supply, Installation, balancing and Commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes,hangers, supports etc., as per approved drawings and specifications of following sheet thickness including alignment, matching and fixing with existing ducting arragements etc., complete as required.
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required.
Supplying and fixing of 19mm thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
Supplying, Fixing, Testing and Commissioning of Fire Dampers made of 16 SWG GSS in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.
Fire Dampers
Actuator
Supply and Fixing of 40 mm dia rigid UPVC pipe conforming to IS 4985-2000 with 6 mm nitrile rubber Insulation complete with fittings, supports etc., for drain piping as required .
Dismantling of existing 22 TR indoor and out door AC units i/c demolishing of the foundation and its accessories, dismantling of associated items like starter panel/copper pipes/power and control cables / trays / dampers / supports etc., i/c shifting and hand over to AAI Store as required.
Supplying and installing 300 mm X 62.5 mm X 2 mm perforated hot dip Galvanised cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, fixed on wall/floor/surface with necessary fixing accessories for running refrigerant piping and cable alongwith control wiring etc., complete as required.
Supply and fixing of 25 mm dia UPVC pipe along with accessories in surface / recess for laying of control cable as required.
Supply and drawing of 2 core x 1.5 sqmm armoured copper conductor FRLS Cable as per IS7098(Part 1)1988 in the existing Conduits as required.
Supply and laying of of 4 C x 16 sqmm XLPE insulated and PVC sheathed armoured copper conductor Cable as per IS7098 (Part 1)1988 cable of 1.1 KV grade in the existing cable tray etc., complete as required.
Supplying and making end termination with brass compression gland and Copper lugs for 4 C x 16 sqmm XLPE insulated and PVC sheathed copper conductor armoured cable of 1.1 KV grade etc., complete as required.
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Earthing with GI earth pipe 4.5 meter long,40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and water pipe etc.(with charcoal/coke and salt) as required.
Providing, fabricating and fixing of 50 mm X 50 mm x 5 mm M.S. angle support for positioning O/D units i/c grouting , necessary foundation, welding, fixing clamps, bolts, nuts and washers and painting with primer and finish paint etc. Complete as required.
Providing and fixing of 14 SWG GSS sheet cover for existing perforated refrigeant pipe / cable tray i/c welding, fixing clamps, bolts, nuts and washers etc., Complete as per site requirement.
Sagar Traders
RS COOLING APPLIANCES
COOL TECH ENGINEERS
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .