Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | ₹31.9 L Quoted ₹34.6 L | L1 | Accepted-AOC AOC |
| 2 | L2₹36.7 L+₹2.1 L (6.05%)Rejected-Finance NEAR RAILWAY STATION UTARLAI BARMER RAJASTHAN PIN 344001 | BARMER | RAJASTHAN | 344001 | ₹36.7 L+₹2.1 L (6.05%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹42.6 L+₹8.1 L (23.3%)Rejected-Finance | ₹42.6 L+₹8.1 L (23.3%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹44.0 L+₹9.4 L (27.2%)Rejected-Finance | ₹44.0 L+₹9.4 L (27.2%) | L4 | Rejected-Finance Other than lowest |
| 5 | Rejected-Technical | - | - | Rejected-Technical Rejected |
Tender Value
₹45.0 L
EMD Value
₹90,000
Closing Date
28 Mar 2023, 6:00 pmClosed
GE (AF) Utarlai
GE (AF) Utarlai PB No.11 Barmer 344001
REPAIR/REPLACMENT OF PIPE LINE, VALVE CHAMBER, CONTROL VALVE, REPAIR TO OHTs, CEILING FAN, WALL FAN, EXHAUST FAN, REPAIR AND MAINT OF RO PLANT/CHLORINATION AND MISC WORK AT AF STN UTARLAI
2023_MES_583687_1
8365/E8
Open Tender
Civil Works - Canal
Item Rate
180 days
Utarlai
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Utarlai
₹90,000
Yes
15 Jun 2023
1 Mar 2023
4 Apr 2023
1 Mar 2023
28 Mar 2023
14 Mar 2023
Amount
Excavation in trenches as in hard / dense soil, not exc 1.5 mtr wide and not exc 1.5 mtr depth for laying of GI/CI pipe lines etc getting out including forming bottom surface to required level and gradient all as specified and directed by Engineer-in-Charge.
Returning and filling in excavated soil including spreading leveling, watering, well ramming in layers not exc 25 cm thick complete, all as specified and directed by Engineer-in-Charge.
Removing of excavated materials not exceeding 50 Mtrs and depositing at a level not exceeding 1.5 M above the starting point, all as specified and directed by Engineer-in-Charge.
S&F of GI pipe, 'medium grade' ISI marked with all fittings laid in trenches including taking down the old tubing complete all as specified and as directed for the following sizes:-
15mm dia of bore
20mm dia of bore
25mm dia of bore
40mm dia of bore
50mm dia of bore
80mm dia of bore
Material and labour of DI pipe (Ductile iron pipe) spigot and socket ends, class "K-9" with rubber gasket (tighten joint) , laid in trenches including necessary cut to length to match the existing fitting/pipes or insertion of new DI specials and including taking down the old CI/DI pipe complete all as specified and directed by the Engineer-in-charge for the following sizes :- Note: DI specials shall be measured and paid seperately
100 mm bore
150 mm bore
Supply and fix of Gun - metal globe or gate valve with iron wheel head, screwed both ends for iron pipes and for unions and fixing including taking down existing unserviceable valves complete all as specified and directed for following sizes:-
50mm dia of bore
40mm dia of bore
25 mm dia of bore
20mm dia of bore
15 mm dia of bore
Material and labour for CI/DI specials such as bends, tees, collars, tail pieces, straight/angle connecting pieces any type (flanged ends, socketed ends or flanged/socketed ends) complete suitable for CI/DI mains of sizes upto 300 mm bore complete all as specified and directed.
Supply and fixing of CI sluice valve with drilled flanged ends, stainless steel spindle with gun metal working parts with hand wheel, pressure type PN 1.0 including disconnection and removing the unserviceable sluice valves from the existing pipe line/valve chamber for the following sizes complete all as directed by the Engineer-in-Charge :-
80mm bore
100 mm bore
150mm bore
200 mm bore
Supply and fixing of CI butterfly valve, heavy duty with necessary packing materials, nut/bolts & washers etc including disconnection and removing the unserviceable butterfly valve from the existing pipe line/valve chamber for the following sizes complete all as directed by the Engineer-in-Charge:-
80mm bore
100mm bore
150mm bore
Dismantling the old valve pit chamber and construct valve chamber 1000x1000x1000 mm (internal ) with PCC block masonary valve chamber, PCC foundation, plastering and necessary earth work in hard/ dense soil, MS sheet cover 3.15 mm thickness along with angle iron frame of size 40 x 40 x 6mm with locking arrangement with necessary fixing materials like hinges, nut/bolts etc (valve chamber cover shall be opened in two halves) and painting to MS cover with one coat of red oxide and two coats of synthetic enamel paint etc all as specified and directed by Engineer-in-Charge. Note:-For reference Drg No. CEAA/TD/57 Sheet 1/1 dt 28 May 1992 with revision upto 31 Dec 1992 shall be followed in consultation with engr-in-charge.
All as per item No. 10.00 above but size of valve chamber is 1200x1200x1200mm (internal)
M & L for road/path cutting for laying of GI/DI pipes upto required depth n. exc 1.5 mtr complete all as directed by Engineer-in-Charge.
M & L for boring of holes 150mm dia under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine complete all as directed by Engineer-in-Charge.
M & L for cement concrete in road surfacing, filling and mass concrete type B1, 1:2:4 (20mm graded stone aggregate) for repairs to road cutting for laying of pipe lines/complete all as directed by Engineer-in-Charge.
S&F in repairs of CI foot valve 80mm dia ISI marked with all fittings complete all as directed by the Engineer-in-Charge
S&Fin repairs of CI foot valve 150mm dia ISI marked with all fittings complete all as directed by the Engineer-in-Charge
S&Fin repairs of PVC foot valve 50mm dia ISI marked with all fittings complete all as directed by the Engineer-in-Charge
S&F in repairs of PVC foot valve 40mm dia ISI marked with all fittings complete all as directed by the Engineer-in-Charge
S&F in repairs of PVC foot valve 25mm dia ISI marked with all fittings complete all as directed by the Engineer-in-Charge
S&F in repairs of ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of size 50mm dia with complete accessories all as directed. Make : Prayag/Water-Tec (Polytub) or Equivalent
All as per item No.20 above but of size 40mm dia
All as per item No.20 above but of size 25/20mm dia
M&L for rectification of existing defective run lead joints including burning and removing the old defective lead joints and providing new lead joints with all required materials and testing the joints for leakages of the following pipes complete including excavation, returining and filling etc.all as directed by Engineer-in-charge.
150mm dia bore CI pipe
100mm dia bore CI pipe
80mm dia bore CI pipe
M&L for attending to break down of 200 to 350mm dia DI pipe line bursting/cracks including necessary excavation, dewatering the water accumulated at site, removal of broken pipe pieces of various lengths through gas cutting/manual cutting as per site requirement including removing out the damaged DI pipe and inserting necessary DI specials such as collar, nipple etc as required at site and providing of new joints as required at site, clamping arrangements, PCC work including testing for the leakages pipes complete all as specified and directed by Engineer-in-Charge.
Material and labour for repairing of valve pit chamber of any size by taking down the old plaster and 10mm thick in CM 1:4 mixed with water proof liquid in complete surface of valve pit and preparing of old steel surfaces and painting to MS cover with one coat of red oxide and two coats of synthetic enamel paint including removing debris/ sludge etc from valve chamber all as specified and directed by Engineer-in-Charge.
Material and labour for repairing of valve pit chamber of any size by taking down the old plaster and 10mm thick in CM 1:4 cement plaster in complete surface of valve pit and preparing of old steel surfaces and painting to MS cover with one coat of red oxide and two coats of synthetic enamel paint including removing debris/ sludge etc from valve chamber all as specified and directed by Engineer-in-Charge.
Cutting green growth / vegetation growth for cleaning out the area by cutting up root, unwanted plants/bushes and removal the same outside the MOD land complete all as specified and directed.
S&F in repair saddle piece made out of MS flat iron of size 50 x 6mm duly welded with 25 to 50mm dia GI socket and 2 Nos nut/bolts of suitable size/length, necessary rubber packing for branch connections for the sizes of 80 to 150mm dia CI/DI mains complete including necessary earth work all as directed by the Engineer-in-Charge
Taking down ceiling fan of any make & sweep by disconnecting clips,lock nuts etc. from existing position of any height. (Note: Repair & maintenance shall be paid seperately under relevant items.)
Hanging only ceiling fan 1200mm/1400mm sweep after repair & maintenance.
M&L for painting of ceiling fan/exhaust fan/wall circulator complete, in situ/lying in store with synthetic enamel paint (white colour) by spraying including filling cavities with filler, one coat after cleaning all dust etc.
M&L for removing of old burnt winding of fan any type and rewinding the stator with superior quality super enamelled copper wire of suitable size including insulation ,drying after varnishing complete all as directed and specified by Engr-in- Charge.
S&F in repair ball bearing suitable for ceiling fan 1200mm/1400mm sweep ISI marked.
S&F in repair fan down rod of size 2' (60 Cm) suitable for ceiling fan 1200/1400 mm sweep complete
S&F in repair of rubber shackle and split pin with galvanised clamp complete with nuts, bults washer, complete all as directed by Engr-in-Charge.
S&F in repairs 2 core PVC insulated PVC sheathed flexible copper wire multistranded of size 40/76mm guage from ceiling rose to fan connector.
S&F in replacement canopy made of plastic complete with nut bolt for fixing in position suitable for ceiling fan 1200mm/1400mm sweep
S&F in repairs of top and bottom cover suitable for ceiling fan complete including nut and bolts all as directed by Engr-in-Charge.
S&F in repairs of spindle for ceiling fan of any type and any make complete all as directed by Engr-in-Charge.
S&F in repairs of stator for ceiling fan of any type and any make complete all as directed by Engr-in-Charge.
S&F in repairs of rotor for ceiling fan of any type and any make including accessories complete all as directed by Engr-in-Charge.
S&F in repairs of blade for ceiling fan of any type and any make complete all as directed by Engr-in-Charge.
S&F in repairs of capacitor 2.5 mfd ISI marked complete all as directed.
S&F in repairs Fan regulator electronic flush type 250 volts suitable for ceiling fan complete.
Taking down exhaust fan of any make & size from existing position of any height for repair, maintenance and refixing the same after neccesary repair complete all as directed. Notes (i) The defective parts to be replaced and shall be measured and paid separately under relevant item of Sch . (ii) Cost of minor items i.e. Screws, nut & bolts etc shall be deemed to be included in the above item.
S&F in repair ball bearing (ISI marked) for exhaust fan of 450mm sweep capacities.
S&F in repair ball bearing (ISI marked) for exhaust fan of 300/380mm sweep capacities.
S & F in replacement of louver suitable for exhaust fan of 450 mm sweep all as specified and directed.
S & F in replacement of louver suitable for exhaust fan of 300 mm sweep all as specified and directed.
M&L for removing old burnt winding of exhaust fan 450mm sweep motor and rewinding the same with superior quality super enamelled copper wire of suitable size including insulation ,drying after varnishing complete all as directed and specified by Engr-in- Charge.
M&L for removing old burnt winding of exhaust fan 300/380mm sweep motor and rewinding the same with superior quality super enamelled copper wire of suitable size including insulation ,drying after varnishing complete all as directed and specified by Engr-in- Charge.
S&F in repair of capacitor 3.15 mfd ISI marked complete all as directed
S&F in repair of capacitor 4 mfd ISI marked complete all as directed
Taking down wall fan/ air circulator of any make & size from existing position of any height for repair, maintenance and refixing the same after neccesary repair complete all as directed. Notes (i) The defective parts to be replaced and shall be measured and paid separately under relevant item of Sch . (ii) Cost of minor items i.e. Screws, nut & bolts, mounting bolt & nuts etc shall be deemed to be included in the above item.
S&F in repair ball bearing (ISI marked) for wall fan of 400/450mm sweep capacities.
S&F in repair ball bearing (ISI marked) for wall fan of 600mm sweep capacities.
S&F in repair metal bush for wall fan of any cap/ any size sweep complete.
M&L for removing old burnt winding of wall fan/ air circulator 400/450mm sweep motor and rewinding the same with superior quality super enamelled copper wire of suitable size including insulation ,drying after varnishing complete all as directed and specified by Engr-in- Charge.
M&L for removing old burnt winding of wall fan/air circulator 600mm sweep motor and rewinding the same with superior quality super enamelled copper wire of suitable size including insulation ,drying after varnishing complete all as directed and specified by Engr-in- Charge.
S&F in repairs of capacitor 6 mfd ISI marked complete all as directed
Comprehensive maintenance/ repair for RO Plant of capacity 5000 Ltrs per hour - 02 Nos as under : (i) Contractor has to provide one service each month by qualified technician (ii) Any complaint shall be attended within 24 Hrs. (iii) Periodical maintenance of cleaning the membrane/ cartridge/ filters with citric acid, washing with high pressure water pump, servicing of chemical dozing systems, calibration of level indicator, valves, greasing of raw water pump, high pressure feed pump, decarburizing of control panel/ LT Panel etc. (iv) Replacement of other major spares as per existing size and capacity shall be measured and paid separately. (v) During dismantling and reassembling, testing of the equipment safety measures shoud be followed and safety equipments like mask, gloves etc shall be provided by contractor and cost of the same shall be deemed to be included in the quoted rates Note: Rate of labour cost for dismantling the spares and assembling the new parts/ system is deemed to be included in the quoted rated of comprehensive maintenance.
Supply the following under mentioned spares/ parts in repair for RO Plant 5000 LPH
Cartridge jumbo filter 20"(Micro filter) 5 micron
Dosing pump 6 LPM
80/40 membrane 2 core line as existing size/ capacity Make: DOW/Hydranautics
PVC rotameter
Multiport valve
Anti scaling chemical
Repair to ACF by opening the chamber, remove all the materials like activated carbon, media upto bottom of the chamber, cleaning the inner walls by using suiatble cleaning agent, remove the fine deposits, cutting the supporting base by welding, fabricate the supporting base as per existing size and shape, fix to the chamber as before by welding, preparing the surface, painting with two coats enamel paint over one coat of red oxide, replacing the gasket of the opening way, filling the ACFwith media pebbles upto the top by laying in layers as before, close the opening and testing should be carried out upto satisfatcion of Engr-in-Charge. Note: Replacement of ACF 600 and various size of media shall be measured and paid separately
Activated Carbon 600
Media 1 to5 mm
Media 5 to10mm
Media 10 to25mm
M&L for washing existing media of size 5 to 10 removed from ACF with suitable acid and water upto satisfaction of Engr-in-Charge.
M&L for washing existing media of size 10 to 25 removed from ACF with suitable acid and water upto satisfaction of Engr-in-Charge.
Supply and fix Pressure gauge 4"dial 0-14 kgs rating including taking down existing unserviceable pressure guage complete all as speciifed and directed by Engr-in-Charge.
Cleaning of PVC tank of capacity 10000 Ltr, dewatering the tank, desilting and removing of left over water from bottom, cleaning tank surfaces by using bleaching powder approx 5 Kg and remove all foreign materials and clean with plain water all as directed by the Engineer-in-Charge. Note:- The job shall be completed within 8 hrs to avoid any interruption in distribution of water supply
Dismantling and assembling of monoblock/ high pressure feed pump set 3 to 7.5 HP capacity, 3 phase incl electric connection and removing it from its position carefully and transporting the same to the work shop for servicing, greasing and refixing the same in its original position after repairs including connection up of water and electric connections including testing and commissioning complete all as specified. Note : (a) The spares required for repair the pump sets and rewinding of motors will be measured and paid separately under respective item. (b) Expendable stores like cotton waste/cleaning materials, lubricants , gland packing, rubber seal, metal filling, machining and transportation to and fro from site to work shop are deemed to be included in rate quoted. (c) Labour elements is included in unit rates.
M & L for rewinding of 3 phase electric induction motor 3 HP capacity with super enameled copper conductor of same guage weight and tuns to achieve its full efficiency including tying the windings and connecting the coils and brining the connections as that of exisitng complete including renewal of worn out/unserviceable bearings etc all as specified and directed by the Engr-in-Charge.
M & L for rewinding of 3 phase electric induction motor 7.5 HP capacity with super enameled copper conductor of same guage weight and tuns to achieve its full efficiency including tying the windings and connecting the coils and brining the connections as that of exisitng complete including renewal of worn out/unserviceable bearings etc all as specified and directed by the Engr-in-Charge.
Supply only the following spares for repairs to monoblock pump set 3 HP 3 phase capacity:-
Ball bearing suitable for induction motor
PVC fan blade with split pin of existing size
Bakelite 3 phase terminal connection box
Supply only the following spares for repairs to vertical type High pressure feed pump set 7.5 HP capacity:-
Ball bearing suitable for induction motor
PVC fan blade with split pin of existing size
Bakelite 3 phase terminal connection box
Stainless steel casing including all accessories as per existing size and shape
CI impeller as per existing size and shape
MS shaft as per existing size and shape
S&F 'U' PVC pipe model SCH 80 of size 15mm dia including all fittings such as tee, bends, socket, reducers, union, elbows etc including taking down old pipe and fittings all as specified and directed by Engr-in-Charge.
S&F 'U' PVC pipe model SCH 80 of size 40mm dia including all fittings such as tee, bends, socket, reducers, union, elbows etc including taking down old pipe all as specified and directed
S&F 'U' PVC ball valve of size 15mm dia all as specified and directed including taking down old valve
S&F 'U' PVC ball valve of size 40mm dia all as specified and directed including taking down valve.
S&F 'U' PVC Union of size 15mm dia all as specified and directed including taking down old fitting.
S&F 'U' PVC Union of size 40mm dia all as specified and directed including taking down old fitting.
Chemical analysis test of filtered water from Govt. agency/recognized / authorized testing laboratory as and when recommended by the Engineer - in- charge.
S&F of rotational moulded polyethylene water storage tanks of capacity 100 Ltrs (cylindrical vertical with closed top) hoisted and fixed in position as per existing size all as specified including dismantling the unsv tank and necessary connections should be done all as directed by Engr-in-Charge.
M&L for bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of enamel paint and including dismantling complete all as specified and directed.
M/S TANUSHREE CONSTRUCTION COMPANY
Devi Engineeing
DHANANJAY CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .