Tender Value
Refer Docs
EMD Value
₹14.3 L
Closing Date
9 Jun 2021, 11:00 amClosed
SE(REMC), RVPN, HEERAPURA, JAIPUR
SE(REMC), sldC BUILDING, RVPN, HEERAPURA, JAIPUR
DESIGN, SUPPLY, INSTALLATION, TESTING COMMISSIONING OF FIRE DETECTION SYSTEM, VERY EARLY SMOKE DETECTION ASPIRATION SYSTEM, FIRE SUPPRESSION SYSTEM, ACCESS CONTROL SYSTEM, DUCTABLE SPLIT AC SYSTEM,CCTV SYSTEM etc.
2021_RRVPN_220458_1
RVPN_REMC_TN11
Open Tender
Electrical Works
304 days
SE(REMC), sldC BUILDING, RVPN, HEERAPURA, JAIPUR
AS PER TENDER DOCUMENTS
5 documents required · 5 mandatory
₹17,700
SR.AO(LD), RVPN
₹14.3 L
Yes
JAIPUR
24 Nov 2021
22 Apr 2021
9 Jun 2021
22 Apr 2021
9 Jun 2021
26 May 2021
5 May 2021
MAIN MATERIAL/ ITEMS
FIRE ALARM SYSTEM
Supply of UL( 9 edition) UL /FM Approved 4 loop panel expandable to 6 loops Addressable Fire Alarm Panel, 250 (125 Detectors & 125 Modules) devices per loop,960 Character Display,The panel consist of Power Supply card, Battery Charger, Printer card, Network card , Batteries are in SI Scope. Upto 999 Events.
Supply of UL( 9 edition) /FM - 1 loop panel expandable to 6 loops TCP /IP enabled CPU with uploading downloading capability . The panel capable of gas releasing control smoke control with email and sms sending capability.The LCD must be multi message capability and easy to operate rotary control .The panel should be capable of digital integrated audio for future requirements.
Supply of Analog Addressable multi sensor detector with LED indication, electronic addressing, multiple sensitivity levels, pre-alarm option, non-volatile memory having provision for self diagnostics and history log, dust and dirt resistant with drift compensation, plug-in design, with compatible mounting bases, junction box and other accessories as required and working on 19 - 24 V DC supply all complete as required. The detectors shall be UL Listed / FM approved.rotary or dip switch type settings not acceptable.
Supply of addressable dual action manual pull station with address switch and all mounting accessories, complete with MS powder coated junction box for mounting on surface, cable lugs at ends, cable compression glands, cable tags and ferruling. UL listed.
Supply of Hooter cum 75cd/115cd STROBE (UL LISTED), complete with base, mounting box, gland, lugs etc. UL listed.
Supply of addressable control Module with all mounting 'accessories, complete with MS Powder coated Junction Box for mounting on Surface, Cable, lugs at Ends, cable compression glands, cable tags .
Supply of addressable Monitor Module with all mounting 'accessories, complete with MS Powder coated Junction Box for mounting on Surface, Cable,lugs at Ends,cable compression glands,cable tags .
Supply of response indicator with matching screws complete with GI junction box, cable lugs at cable end and ferruling.
Supply of Conventional UV flame detector - spark detector for detection smoke in the electric panels.
Supply of ISI Marked 2 x 1.5 sq mm, Multi-stranded Copper. FRLS. Armoured cable, RED in colour, laid on surface with GI saddle-spacers every 0.3 meters. Complete with GI Junction Box, lugs, cable comprression glands, tags & Ferruling.
MANDATORY SPARES-FIRE ALARM SYSTEM
Detector
Control module
Monitor module
Response indicator
Power Supply
loop card
FIRE FIGHTING (HYDRANT) SYSTEM
Supply of fire service main pump, multistage, of 1650 LPM (Litres/ min.) at 30 m head centrifugal type, 50 HP of suitable HP as per specification and as directed by Engineer etc. complete
Supply of Jockey Pump of 240 LPM at 30 m head, 3 ph. 415 A.C.15 HP, (11 kW) or of suitable HP with suitable Stages as per specification.
Supply of automatic motor control center for hydrant, & jockey and booster pumps to suit the HP of motor for the rated capacity and desired head of pumps. MCC shall be provided with suitable starters and controls for 1 No. Hydrant pump (Electrically operated) 1 No. Jockey pump 1 No. Booster pump.
Supply of G.I. Heavy grade 'C' class pipes (I.S. 1239 part I) with necessary clamping to wall beams and ceilings with hangers and clamps anchor fasteners wherever required to firmly support piping.
150 mm dia.
100 mm dia
80 mm dia.
50 mm dia.
25 mm dia.
Supply of metal Stainless Steel single outlet hydrant valve fitted with necessary accessories complete as per specification.
Supply of M.S./CRCA cabinet for housing Fire Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.
Supply of wall mounting swinging Hose reel drum fitted with 19 mm dia. 30mhigh pressure polypropylene (Polyhose)long fitted with necessary accessories complete as per specification
Supply of SS branch Pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle as per specifications.
Supply of fire fighting R.R.L. Hose pipe, 63mm dia,15m in length, fitted with necessary accessories complete as per specification.
Supply of 25 mm dia PN 10 Ball valve as per specification.
Supply of 3 Core x 16 sq. mm Copper conductor Armored FRLS Insulated with color coding for individual cores and black outer sheath all complete
Supply of 3 Core x 4 sq. mm Copper conductor Armored FRLS Insulated with color coding for individual cores and black outer sheath all complete
Supply of CI butterfly valves as per BS 5155 ( PN 16) slim seal with required flanges, nuts, bolts etc. complete.
150 mm dia.
100 mm dia.
80 mm dia.
Supply of C.I. Non-return valves (PN 16) swing check type with required flanges, nuts, bolts and gaskets etc. complete.
150 mm dia.
100 mm dia.
80 mm dia.
Supply of SS Pressure Gauge with all accessories.
Supply of SS Pressure Switch with all accessories.
Supply of CI Ball type foot valve with required flanges, nuts, bolts etc. complete.
150 mm dia.
100 mm dia.
MANDATORY SPARES-FIRE FIGHTING SYSTEM
25mm Ball Valve
Pressure Switch
Pressure Gauge
FIRE SUPPRESSION SYSTEM
Supply of UL &FM Approved 140 ltrs Seamless Tank and valve assembly, Super pressurised with Nitrogen. Gas design concentration @ % v/v shall be 4.5 and @ 25 Bar.
Supply of UL &FM Approved 120 ltrs Seamless Tank and valve assembly, Super pressurised with Nitrogen. Gas design concentration @ % v/v shall be 4.5 and @ 25 Bar.
Supply of UL &FM Approved 80 ltrs Seamless Tank and valve assembly, Super pressurised with Nitrogen. Gas design concentration @ % v/v shall be 4.5 and @ 25 Bar.
Supply of Novec 1230 Gas
Supply of Master Cylinder Accessories with UL&FM Approved of Make including Control Head, 24 V DC, Discharge Hose, 2" x 31", Warning Sign - NOVEC 1230
Supply of MID SLAVE ACCESSORY KIT_IN includingPressure Operated Control Head, Actuation Hose, 30", Male Branch Tee, 5/16" Flare x 1/8"NPT, Discharge Hose, 2" x 31"
Supply of End Slave Cylinder Accessories including Pressure Operated Control Head, Actuation Hose, 30", Discharge Hose, 2" x 31", Master Cylinder Adaptor Kit ,Male Elbow, 5/16' Flare x 1/8" NPT
Supply of UL &FM Approved NOZZLE BRASS - 360 /180 Degree. All Nozzle in room void area to be fixed within cold aisle containment area.
Supply of El Check 2" (Manifold Check Valve)
Supply of Seamless Piping for Fire suppression System
Supply of Manual Gas Release & Abort Station
Supply of Discharge Pressure Switch
Supply of LED type display sign board.
Supply of 2 Core X 1.5 Sq mm Cu armoured cable 1100 volt grade XLPE insulated FRLS PVC outer sheathed copper conductor armoured cable as per specification in existing trenches, cable trays ducts , clamped to wall with suitable clamps, including fixing bolts, connecting testing and commissioning.
CIVIL INTERIOR WORK
Gypsum Partition:
Supply of fire rated wooden partition minimum 50mm thick.
Supply of fire rated plywood above false ceiling minimum 18mm thick.
Supply of fire rated plywood for VPS enclosure area minimum 18mm thick with fire rated laminated sheet in REMC VPS Enclosure room
Supply of fire rated plywood for VPS LD control room area minimum 18mm thick with fire rated laminated sheet in REMC VPS Enclosure room
Supply of min. 10 mm thick Fire rated glass for 120 min with fire rated in wood/metal frame work inside room with all accessories.
DOORS:
Supply of 120 minutes fire rated wooden Fire doors size of 2400x2200 mmwith double leaf as per requirement.
MANDATORY SPARES-FIRE SUPPRESSION SYSTEM
Abort Switch
Release Switch
Pressure Switch
Solenoid Actuator
Power Supply
7AH Battery
140 Litres 4 Nos. Cylinder Bank with 474 Kg Clean Agent
ASPRATION SYSTEM (VESDA)
Supply of VESDA Single Zone Aspiration Smoke Detector Panel along with Power Supply
Supply of 25 mm UPVC Conduit along with necessary accessories
Supply of Sampling Point Nozzle for Capillary tube end and Label along with accessories
Supply of ISI Marked 2 x 1.5 sq mm, Multi-stranded Copper. FRLS. Armoured cable, RED in colour, laid on surface with GI saddle-spacers every 0.3 meters. Complete with GI Junction Box, lugs, cable comprression glands, tags & Ferruling.
Supply of Conventional Sounder
MANDATORY SPARES-VESDA
Sampling Points
CCTV SYSTEM
Indoor Varifocal Dome: Supply of 2MP IP Network TDN Low-Light IR Dome Camera, 1/2.8" CMOS, 2 MP @ 25fps or better, Min. Illumination required 0.001 lux @ F1.6 (color) with Scene Adaptive Control, Min. Pixels 1920 × 1080, Shutter Speed 1/3 - 1,00,000; Adavance Video Compression technology such as H.265 & H.264 High Profile , Triple stream, 2.7–13.5 mm motorized focus & zoom lens, BLC, HLC, 3DNR, Minimum Edge Intelligence Video Analytics : Motion Detection, Video Tampering, Face Detection, SD Card Error, SD Card Capacity Warning, Audio Detection, Object Abandoned, Object Missing, Tripwire, Intrusion; Privacy Mask, Smart IR with upto 20m IR distance, AES-256, d, PCI Data Security Standard compliance, Hardware chipset for private key; Dual channel Audio G.711a/ G.711Mu/ AAC/G.726, 128GB SD card support, Alarm: 2 In/ 1out, PoE Class 4 (802.3 at) and 12V DC, support aux. power supply of 2W ,12VDC for powering low power devices such as strobe light/hooter/ mic, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S, G and Q compliant, UL, CSA 60950-22, CE (EN 50130-4 & EN 55032), FCC Part 15 &RoHS compliant.
Box/Bullet: Supply of 2MP IP Network TDN Low-Light IR Rugged box/Bullet Camera, 1/2.8" CMOS, 2 MP @ 25fps or better, Min. Illumination required 0.001 lux @ F1.6 (color), 120dB True WDR with Scene Adaptive Control, Min. Pixels 1920 × 1080, Shutter Speed 1/3 - 1,00,000; Adavance Video Compression technology such as H.265 & H.264 High Profile , Triple stream, 2.8-13.5 mm 5X motorized focus & zoom lens, BLC, HLC, 3DNR, Minimum Edge Intelligence Video Analytics : Motion Detection, Video Tampering, Face Detection, SD Card Error, SD Card Capacity Warning, Audio Detection, Object Abandoned, Object Missing, Tripwire, Intrusion; Privacy Mask, Smart IR with upto 60m IR distance, IR to be internall/external, AES-256, PCI Data Security Standard compliance, Hardware chipset for private key; Dual channel Audio G.711a/ G.711Mu/ AAC/G.726, 128GB SD card support, Alarm: 2 In/ 1out, PoE Class 4 (802.3 at) and 12V DC,support aux. power supply of 2W ,12VDC for powering low power devices such as strobe light/hooter/ aux. IR illuminator /etc., IP 67, IK 10 vandal proof, Die-Cast Aluminium Housing, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S, G and Q compliant, UL, CSA 60950-22, CE (EN 50130-4 & EN 55032) , FCC Part 15, UL2900-1 &RoHS compliant.
Outdoor PTZ: Supply of IP Network TDN Low-Light PTZ Camera with auto tracking, 1/2.8" CMOS, 4 MP @ 25fps, triple stream, Min. Illumination required 0.005 lux @ F1.6 (color) & 0 lux @ F 1.6(B/W) or better, 120dB True WDR or better, Min. Pixels 2560 x 1440, triple stream, 4mm –180 mm 45x motorized focus & zoom lens, BLC, HLC, 3DNR, Defog, Electronic Image Stabilitzation, 24 Privacy Mask, 500 Presets, Internal / External Illuminatrion range with upto 200m IR distance, Dual channel Audio G.711a/G.711u/AAC, 128GB SD card support, Alarm: 2 In/1 out, H.265 and MJPEG, PoE Class 5 and 12V DC/24VAC, IP 67, IK 10 vandal proof, Having Operating temp range : –10°C to 70° C. mounting Brackets suitable for Pole / Wall mounting, 24V AC operated including Power Supply adaptor for camera & required accesories. Profile S, G compliant, UL, CE, FCC certified.
a. Processor: Quad-core embedded processor
b. Internal Storage: 8 SATA ports 8 TB each (64 TB total)
c. Operating System: Embedded Linux/Window
d. Storage Capacities: Up to 64 TB
e. Video Storage Hard Disk Options: Internal fixed up to 8 TB SATA Hard Disk Drive options
f. Inputs and Outputs: 16 channels alarm inputs, 6 channels alarm relay outputs, 1 RS232, 2 USB ports
g. Network Interface:a. 1 RJ-45 port (10/100/1000 Mbps), b. 16 PoE ports (IEEE802.3af/at)
h. Monitor Output: 1 HDMI; 1 VGA+B8
i. Operating temperatures shall be between 14°F (−10°C) and 131°F (55°C).
j. Operating Relative Humidity: 10% to 90%, non-condensing.
k. Emissions: FCC Part 15B; EN 55032: 2012 + AC: 2013, EN 61000-3-2: 2014, EN 61000-3-3: 2013.
l. Immunity: EU – EN 50130-4: 2011 + A1: 2014, EN 55024: 2010 + A1: 2015.
m Safety: North America UL Listed to UL/CSA 60950-1; EU – EN 60950-1.
n. RoHS: EN 50581: 2012.
Supply of Client Workstation as per following specifications:Intel® Core™ Intel Core i7-8700, 3.2 GHz, OS - Genuine Microsoft Windows® 10 Enterprise 64-bit, RAM - 16GB, Hard Drives - 500 GB 7200RPM SATA3, Video Adaptor - Integrated Intel UHD graphics 630 supporting 2 Monitors over HDMI/VGA, Network Connection - 1 Gbit/sec or greater, Two(2) PCI-Express Expansion Slots 2/4 USB, CD/DVD ROM, USB Keyboard and Mouse, UPS, associated cables etc complete as required
Supply of Display screen for Client PC 32" (for 24X7 working operations), LED Flat Screen HD with remote control, HDMI/VGA input and wall mount unit / floor stand complete with all necessary accessories & peripheral items for civil, electrical works as required.
Supply of TCP/IP based, Keyboad Joystick for PTZ. POE Support
Supply of Power Supply for PTZ camera (12VDC/3A)
Supply of 8TB HDD for storage of all cameras for 45 days at 720P, 15 FPS.
Supply of 24 port 10/100/1000 Mbps Gigabit PoE+ layer 2 Managed switches with 2 SFP Port, 195W (PoE+ supported) Power, IP multicast snooping ,Data-driven IGMP upport, Standard 802.1d Spanning Tree support, Support for IEEE 802.3ad Link Aggregation Control Protocol (LACP).
Supply of 9U - Wall mounted Communication rack with glass doors, handles ,lock , Top and Bottom Cable entries, Supports for mounting rack on wall , Cable managers, Fan, Equipment mounting hardware, power supply box for supplying power to switches, fans etc along with earth continuity kit, Mcb, indicator, moulded power supply cable.
Supply of interconnecting cable like HDMI, VGA, and onter accessories to complete the requirement.
Supply of Cat-6 cable laid on surface with GI saddle-spacers, or in cable tray or in GI conduits as per site requirement with required terminations as required with cable ties and tags
Supply of approved make 25 mm dia.PVC flexible conduits on ceiling / wall / floor etc. complete with accessories like, Junction boxes, Collars, Bends etc.
MANDATORY SPARES-CCTV SYSTEM
Image Sensor
Power Supply
HDMI cable 5 mtr
Mother Board
ACCESS CONTROL SYSTEM
Supply of 4 Reader Controller which will sit directly on TCP/IP, which can handle at least 50 Users. The controller should be inside the Metal cabinet with SMPS with converter to integrate with BMS
Supply of Main Access Control Software with CCTV and BMS integration.
Supply of Proximity Card Readers ( Range 2” – 3”)
Supply of RoHS Compliant Fingerprint Biometric Reader with inbuilt Smart Card Reader with capability to handle at least 4000 Templates
Supply of Proximity Cards ( Blank)
Supply of Electromagnetic Lock (600 LBS - Dual Leaf) with Door Position Sensor & necessary accessories
Supply of Emergency exit auto release in case of fire (Includes Panic BAR, EML and mechanism to open the EML by pressing the Panic bar, One hooter to be connected for door opening alarm in any condition)
Supply of Emergency Release Box
Supply of 8.0 Core x 1.5 sq mm flexible FR Copper conductor Cable
Supply of 25 mm PVC MMS Conduit, laying of all data, control and communication cables in conduits
Supply of Cat-6 cable laid on surface with GI saddle-spacers, or in cable tray or in PVC conduits as per site requirement.
MANDATORY SPARES-ACCESS CONTROL SYSTEM
Controller
Reader
Electromaganetic Lock
Release Switch
Power Supply
RODENT REPELLANT SYSTEM
Supplyof Rodent repellant controller Rodent digital repellant panel shall support 20 transduser in looped network with floor standing mounting rack.
Supply of field transduser with minimum coverage area of 150 sq.ft for Above false ceiling void, and below false floor void, 300 sq ft. for main void suitable for above controller.
Supply of 2 core (14/40SWG) multi strand cable Rodent panel to transducer.
Supply of 20mm dia PVC FRLS conduit with all accessories.
WATER LEAKAGE DETECTION SYSTEM
Supply of 4 Zone Water Leak Detection Panel conforming to the technical specifications.
Supply of Water Leak Detection Cable with necessary clamps conforming to the specifications.
Supply of sounder conforming to the specifications
Supply of Clips and accessories.
MONITORING SYSTEM/ BMS
Supply of Integrated Building Management System Software complete as per specifications, for integrating DDC Controllers, Fire Alarm System, VESDA System,Fire Suppression System & Access Control System, on seamlessly integration platform. The license shall be priced for 1000 points and 1 no client station license.
Supply of 32 Bit on board IP based Direct digital controller for monitoring of Gas release system, T&Rh Sensor, Electrical System along with enclosure & power supply etc. complete as reqd.
Supply of Bacnet / Mod bus Driver for the System intregation for FSS.
Supply of Desktop type computer system comprising of Intel Core i7-6700 3.4 8M GT2 4C CPU, 8GB DDR4 Ram, 1TB SATA HDD, DOS, Super Multi DVD, Intel Skylake HD Graphics, Power Supply 88% Eff, 3 Years Warranty Nvediaquadro K420 2GB Graphic, optical Mouse, 104 Keys keyboard with 4 hi speed USB ports, 2 serial ports and one parallel port with all necessary components, modules etc.,with 20" LCD Monitor.
Supply of 32" LED Display for Monitoring the System.
Supply of Hydrogen Sensor for battery room.
Supply of Temp & RH Sensor.
Supply of 4 Core 1.5 Sqmm cu armoured FRLS cable with all accessories.
Supply of Cat-6 cable laid on surface with GI saddle-spacers, or in cable tray or in PVC conduits as per site requirement.
Supplyof 25 mm PVC MMS Conduit, laying of all data, control and communication cables in conduits
MANDATORY SPARES- MONITORING SYSTEM/ BMS
Digital input
Digital output
Analouge input
Analouge output
AIRCONDITIONING SYSTEM
BATTERY ROOM
Supply of Air cooled condesing units, comprising of scroll compressors of 11 TR (Nominal) capacity, single Outdoor unit, Air cooled condenser unit consisting of condenser fan, copper condenser coils, including pressure testing, gas charging with R 410A refrigerant suitable for operation on 3 phase, 415 V, 50 Hz A.C supply etc. complete as required.e
SCADA Control Room
Supply of Air cooled condesing units, comprising of scroll compressors of 8.5 TR (Nominal) capacity, , single Outdoor unit,Air cooled condenser unit consisting of condenser fan, copper condenser coils, including pressure testing, gas charging with R 410A refrigerant suitable for operation on 3 phase, 415 V, 50 Hz A.C supply etc. complete as required.
REMC Control Room
Supply of Air cooled condesing units, comprising of scroll compressors of 11 TR (Nominal) capacity, , single Outdoor unit,Air cooled condenser unit consisting of condenser fan, copper condenser coils, including pressure testing, gas charging with R 410A refrigerant suitable for operation on 3 phase, 415 V, 50 Hz A.C supply etc. complete as required along with the following.
Supply of Air cooled ductable floor mounted package unit, comprising of scroll compressors of 5.5 TR (Nominal) capacity, cooling coil, evaporator, blower and washable/cleanable filter all housed in a powder coated sheet metal cabinet of robust construction and one number Air cooled condenser unit consisting of condenser fan, copper condenser coils, including pressure testing, gas charging with R 410A refrigerant suitable for operation on 3 phase, 415 V, 50 Hz A.C supply etc. complete as required along with the outdoor unit.
STOMS Backup Control Room & New Communication Equipment Room
Supply of Air cooled ductable floor mounted package unit, comprising of scroll compressors of 8.5 TR (Nominal) capacity, with Twin compressors and single ODU unit,cooling coil, evaporator, blower and washable/cleanable filter all housed in a powder coated sheet metal cabinet of robust construction and one number Air cooled condenser unit consisting of condenser fan, copper condenser coils, including pressure testing, gas charging with R 410A refrigerant suitable for operation on 3 phase, 415 V, 50 Hz A.C supply etc. complete as required along with the along with the outdoor unit.
Communication Room
Supply of Air cooled ductable floor mounted package unit, comprising of scroll compressors of 8.5 TR (Nominal) capacity, with Twin compressors and single ODU unit,cooling coil, evaporator, blower and washable/cleanable filter all housed in a powder coated sheet metal cabinet of robust construction and one number Air cooled condenser unit consisting of condenser fan, copper condenser coils, including pressure testing, gas charging with R 410A refrigerant suitable for operation on 3 phase, 415 V, 50 Hz A.C supply etc. complete as required along with the along with the outdoor unit.
VPS LD Control Room
Supply of Air cooled ductable floor mounted package unit, comprising of scroll compressors of 5.5 TR (Nominal) capacity, cooling coil, evaporator, blower and washable/cleanable filter all housed in a powder coated sheet metal cabinet of robust construction and one number Air cooled condenser unit consisting of condenser fan, copper condenser coils, including pressure testing, gas charging with R 410A refrigerant suitable for operation on 3 phase, 415 V, 50 Hz A.C supply etc. complete as required along with the outdoor unit.
Supply of 18 G Hard Drawn Copper Piping between Indoor & Out Door for Suction & Discharge Lines of suitable size as per manufacturers' standards including all fitting & accessories. Copper Piping should be suitably supported at regular intervals. The Copper pipe should be insulated with 13 mm thick nitrile rubber insulation.
LOW SIDE
Supply of indoor hanging rod
Supply of Canvas Connection
Supply of 22 Gauge ducting with supports, nuts, bolts & gaskets complete as required.
Supply of 24 Gauge ducting with supports, nuts, bolts & gaskets complete as required.
Supply of Thermal Insulation with Nitrile Rubber
Supply of Acoustic Insulation for plennum
Supply of soft drawn Copper refrigerant piping with 9 mm thick tube nitrile rubber cover including accessories bracing between indoor and outdoor air-cooled condensers of the following size with necessary supports & fittings as required.
Supply of 11/8 " dia soft copper pipeline with insulation.
Supply of 7/8 " dia soft copper pipeline with insulation.
Supply of 5 /8 " dia soft copper pipe line with insulation.
Supply of 1/2 " dia soft copper pipe line with insulation.
Supply of 4 core x 4 sq. mm PVC insulated, PVC sheathed, unarmoured copper conductor multi core cable for providing connections to existing AC units between indoor unit and outdoor units including connections, testing, earthing etc. as required.
Supply of control cable between indoor and out door units of size 3 core x 2.5 sqmmXLPE/PVC insulated copper conductor in PVC conduit including accessories like cable glands & Lugs etc. as required.
Supply of control cable between indoor and out door units of size 3 core x 1.5 sqmmXLPE/PVC insulated copper conductor in PVC conduit including accessories like cable glands & Lugs etc. as required.
Supply of control cum transmission cable between indoor and out door units of size 4 core x 10sqmmXLPE/PVC insulated copper conductor in PVC conduit including accessories like cable glands & Lugs etc. as required.
Supply of Sequencer Units for UPS room for 8 hours running operation etc. as required.
Supply of powder coated aluminium grills / diffusers
Supply of MS Stang for Outdoor Unit
Supply of Volume Control Damper
Supply of AHU 22 TR for Transformer room
Supply of AHU 17 TR for Sacdda Control room
Supply of AHU 11 TR for REMC Control room
MANDATORY SPARES-AIRCONDITIONING SYSTEM
Condenser
Mother Board (PCB)
REDUNDANT ELECTRICAL DISTRIBUTION SYSTEM
Supply of 100 Amp 4P MCCB with enclosure and rotary handle.
Supply of UPS Electrical Distribution System Panel as per SLD.
Supply of AC Electrical Distribution System Panel as per SLD.
Supply of 4 way TPN DB, incomer 63 Amp 4P RCCB, 30 mA 1 no. and outgoing 32 Amp SP MCB D Curve 12 nos with all accessories.
Supply of 8 way TPN DB, incomer 63 Amp 4P RCCB, 30 mA 1 no. and outgoing 32 Amp SP MCB D Curve 24 nos with enclosure and all accessories. for communication room
Supply of IP based intelligent PDUs of 230V AC, 32amps, 24 Outlets (20 x C13 and 4 x C19, 32A IEC 60309 plug P + N + PE, 7.4 kVA, zero U vertical IPDU, Ethernet, serial and sensor connections.
Supply of industrial socket 32 amps, 230 V, 1P+N+E IEC 309, industrial Socket with Plug, including the cost of supplying and fixing metal box, mounted on wall/under raised floor/Cable Tray.
Supply of industrial socket 16 amps, 230 V, 1P+N+E IEC 309, industrial Socket with Plug, including the cost of supplying and fixing metal box, mounted on wall/under raised floor/Cable Tray.
Supply of 4 Core x 35 sqmm cu armoured cable from UPS to UPS Distribution Panel
Supply of 4 Corex 16 sqmm cu armoured cable UPS distribution Panel to Distribution Panel of each rooms DB.
Supply of 3 Corex 6 sqmm cu armoured cable DB to 32A industrial socket
Supply of 3 Corex 4 sqmm cu armoured cable DB to 16A industrial socket
Supply of Copper plate earthing 600x 600x3.15mm for UPS with suitable size of copper strip earth pit as per IS 3043. The earth pit shall be provided with water pipe (Class B) with wire mesh funnel 12SWG copper wire up to chamber, disconnecting link with 600 x 600mm (clear) RCC Chambers and 3mm thick heavy-duty CI checker plate cover with hinge.
Supply of 25 X 3 mm Cu Strip with all accessories
Supply of 1C X 6 Sqmm Cu Flex PVC Insulated Cable for earthing
Supply of Automatic Transfer Switch (ATS) 6 KVA 1U rack mount
Supply of all type Cable end termination of the PVC insulated PVC sheathed copper conductor armoured / flexible cables of 1100-volt grade including supplying and fixing of single Compression Heavy Duty Copper lugs with Compound complete as required.
Description of Work / Item(s)
MAIN MATERIAL/ITEMS
FIRE ALARM SYSTEM
Installation, testing and commissioning of Fire Alarm System supplied as per Schedule-BOQ B1 (supply part) item no. (A)
FIRE FIGHTING (HYDRANT) SYSTEM
Installation, testing and commissioning of Fire Alarm System supplied as per Schedule-BOQ B1 (supply part) item no. (B)
Civil Water Tank 1 lakh ltr
FIRE SUPPRESSION SYSTEM
Installation, testing and commissioning of Fire Suppression System with Cylinder, cylinder accessories,nozzle,piping and cabling etc. supplied as per Schedule-BOQ B1 (supply part) item no. (C)
CIVIL INTERIOR WORK
Gypsum Partition:
Installation of fire rated wooden partition minimum 50mm thick.
Installation of fire rated plywood above false ceiling minimum 18mm thick.
Installation of fire rated plywood for VPS enclosure area minimum 18mm thick with fire rated laminated sheet in REMC VPS Enclosure room
Installation of fire rated plywood for VPS LD control room area minimum 18mm thick with fire rated laminated sheet in REMC VPS Enclosure room
Fixing of min. 10 mm thick Fire rated glass for 120 min with fire rated in wood/metal frame work inside room with all accessories.
DOORS:
Fixing of 120 minutes fire rated wooden Firedoors size of 2400x2200 mmwith double leaf as per requirement.
ASPRATION SYSTEM (VESDA)
Installation, testing and commissioning of VESDA Single Zone Aspiration Smoke Detector Panel along with Power Supply
Installation of 25 mm UPVC Conduit along with necessary accessories
Installation of Sampling Point Nozzle for Capillary tube end and Label along with accessories
Installationof ISI Marked 2 x 1.5 sq mm, Multi-stranded Copper. FRLS. Armoured cable, RED in colour, laid on surface with GI saddle-spacers every 0.3 meters. Complete with GI Junction Box, lugs, cable compression glands, tags & Ferruling.
Installation ofConventional Sounder. The strobe shall be adjustable to 110 candelas. wall/ceiling mounted with mounting base & required accessories complete.
CCTV SYSTEM
Indoor Varifocal Dome: Installationof 2MP IP Network TDN Low-Light IR Dome Camera along with accessoriessupplied as per Schedule-BOQ B1 (supply part)item E(1)
Box/Bullet: Installationof 2MP IP Network TDN Low-Light IR Rugged box/Bullet Cameraalong with accessories supplied as per Schedule-BOQ B1 (supply part)item E(2)
Outdoor PTZ: Installationof IP Network TDN Low-Light PTZ Camera with auto trackingalong with accessories supplied as per Schedule-BOQ B1 (supply part)item E(3),
Installationof 32 Channel/Server Hardwareand accessoriessupplied as per Schedule-BOQ B1 (supply part)item no. E(4)
Installationof Client Workstationand accessories supplied as per Schedule-BOQ B1 (supply part) no. E(5)
Installation of Display screen for Client PC 32" (for 24X7 working operations), LED Flat Screen HD with remote control, HDMI/VGA input and wall mount unit / floor stand complete with all necessary accessories & peripheral items for civil, electrical works as required.
Installation of TCP/IP based, Keyboad Joystick for PTZ. POE Support
Installation of Power Supply for PTZ camera (12VDC/3A)
Installation of of 8TB HDD for storage of all cameras for 45 days at 720P, 15 FPS.
Installation of 24 port 10/100/1000 Mbps Gigabit PoE+ layer 2 Managed switches with 2 SFP Port, 195W (PoE+ supported) Power, IP multicast snooping ,Data-driven IGMP upport, Standard 802.1d Spanning Tree support, Support for IEEE 802.3ad Link Aggregation Control Protocol (LACP).
Installationof 9U - Wall mounted Communication rack with glass doors, handles ,lock , Top and Bottom Cable entries, Supports for mounting rack on wall , Cable managers, Fan, Equipment mounting hardware, power supply box for supplying power to switches, fans etc along with earth continuity kit, Mcb, indicator, moulded power supply cable.
Installationof Armoured Cat-6 cable laid on surface with GI saddle-spacers, or in cable tray or in GI conduits as per site requirement with required terminations as required with cable ties and tags
Installationof approved make 25 mm dia.PVC flexible conduits on ceiling / wall / floor etc. complete with accessories like, Junction boxes, Collars, Bends etc.
Excavation (Except Hard Rock) & Backfilling, without Brickwork and trench's for cable installation.
HARD Rock Excavation / or tunnelling in pathway areas for cable installation
ACCESS CONTROL SYSTEM
InstallationTesting and commissioningof 4 Reader Controller which will sit directly on TCP/IP, which can handle at least 50 Users. The controller should be inside the Metal cabinet with SMPS with converter to integrate with BMS
Installation, Testing and commissioning of Main Access Control Software with Basic Time & Attendance in BMS / DCIM and with all reports to be made available to RCF
Installationof Proximity Card Readers ( Range 2” – 3”)
Installation, Testing and commissioning of RoHS Compliant Fingerprint Biometric Reader with inbuilt Smart Card Reader with capability to handle at least 4000 Templates
Installation, Testing and commissioning of Electromagnetic Lock (600 LBS - Dual Leaf) with Door Position Sensor & necessary accessories
Installation, Testing and commissioning of Emergency exit auto release in case of fire (Includes Panic BAR, EML and mechanism to open the EML by pressing the Panic bar, One hooter to be connected for door opening alarm in any condition)
Installationof Emergency Release Box
Installation of 8.0 Core x 1.5 sq mm flexible FR Copper conductor Cable
Installationof 25 mm PVC MMS Conduit, laying of all data, control and communication cables in conduits
Installationof Cat-6 cable laid on surface with GI saddle-spacers, or in cable tray or in PVC conduits as per site requirement.
RODENT REPELLANT SYSTEM
Installation, Testing and commissioning Rodent repellant controller Rodent digital repellant panel shall support 20 transduser in looped network with floor standing mounting rack.
Installation, Testing and commissioning of field transduser with minimum coverage area of 150 sq.ft for Above false ceiling void, and below false floor void, 300 sq ft. for main void suitable for above controller.
Surface laying of 2 core (14/40SWG) multi strand cable Rodent panel to transducer.
Installation of 20mm dia PVC FRLS conduit with all accessories.
WATER LEAKAGE DETECTION SYSTEM
Installation, Testing and Commissioning of 4 Zone Water Leak Detection Panel conforming to the technical specifications.
Laying of Water Leak Detection Cable with necessary clamps conforming to the specifications.
Fixing of sounder conforming to the specifications
Fixing ofClips and accessories.
MONITORING SYSTEM/ BMS
Installation, Testing & Commissioning of Integrated Building Management System Software complete as per specifications, for integrating DDC Controllers, Fire Alarm System, VESDA System,Fire Suppression System & Access Control System, on seamlessly integration platform.
Installation, Testing & Commissioning of 32 Bit on board IP based Direct digital controller for monitoring of Gas release system, T&Rh Sensor, Electrical System along with enclosure & power supply etc. complete as reqd.
Installation, Testing & Commissioning of Bacnet / Mod bus Driver for the System intregation for FSS.
Installationof Desktop type computer system comprising of Intel Core i7-6700 3.4 8M GT2 4C CPU, 8GB DDR4 Ram, 1TB SATA HDD, DOS, Super Multi DVD, Intel Skylake HD Graphics, Power Supply 88% Eff, 3 Years Warranty Nvediaquadro K420 2GB Graphic, optical Mouse, 104 Keys keyboard with 4 hi speed USB ports, 2 serial ports and one parallel port with all necessary components, modules etc.,with 20" LCD Monitor.
Installationof 32" LED Display for Monitoring the System.
Installation, Testing & Commissioning of Hydrogen Sensor for battery room.
Installation, Testing & Commissioning of Temp & RH Sensor.
Laying of 4 Core 1.5 Sqmm cu armoured FRLS cable with all accessories.
Installationof Cat-6 cable laid on surface with GI saddle-spacers, or in cable tray or in PVC conduits as per site requirement.
Installationof 25 mm PVC MMS Conduit, laying of all data, control and communication cables in conduits
AIRCONDITIONING SYSTEM
BATTERY ROOM
Installation of Air cooled condesing units, comprising of scroll compressors of 11 TR (Nominal) capacity, single Outdoor unit, Air cooled condenser unit consisting of condenser fan, copper condenser coils, including pressure testing, gas charging with R 410A refrigerant suitable for operation on 3 phase, 415 V, 50 Hz A.C supply etc. complete as required.
SCADA Control Room
Installation of Air cooled condesing units, comprising of scroll compressors of 8.5 TR (Nominal) capacity, , single Outdoor unit,Air cooled condenser unit consisting of condenser fan, copper condenser coils, including pressure testing, gas charging with R 410A refrigerant suitable for operation on 3 phase, 415 V, 50 Hz A.C supply etc. complete as required.
REMC Control Room
Installation of Air cooled condesing units, comprising of scroll compressors of 11 TR (Nominal) capacity, , single Outdoor unit,Air cooled condenser unit consisting of condenser fan, copper condenser coils, including pressure testing, gas charging with R 410A refrigerant suitable for operation on 3 phase, 415 V, 50 Hz A.C supply etc. complete as required along with the following.
Installation of Air cooled ductable floor mounted package unit, comprising of scroll compressors of 5.5 TR (Nominal) capacity, cooling coil, evaporator, blower and washable/cleanable filter all housed in a powder coated sheet metal cabinet of robust construction and one number Air cooled condenser unit consisting of condenser fan, copper condenser coils, including pressure testing, gas charging with R 410A refrigerant suitable for operation on 3 phase, 415 V, 50 Hz A.C supply etc. complete as required along with the outdoor unit.
STOMS Backup Control Room & New Communication Equipment Room
Installation, testing and commissioning of Air cooled ductable floor mounted package unit, comprising of scroll compressors of 8.5 TR (Nominal) capacity, with Twin compressors and single ODU unit,cooling coil, evaporator, blower and washable/cleanable filter all housed in a powder coated sheet metal cabinet of robust construction and one number Air cooled condenser unit consisting of condenser fan, copper condenser coils, including pressure testing, gas charging with R 410A refrigerant suitable for operation on 3 phase, 415 V, 50 Hz A.C supply etc. complete as required along with the along with the outdoor unit
Communication Room
Installation, testing and commissioning of Air cooled ductable floor mounted package unit, comprising of scroll compressors of 8.5 TR (Nominal) capacity, with Twin compressors and single ODU unit,cooling coil, evaporator, blower and washable/cleanable filter all housed in a powder coated sheet metal cabinet of robust construction and one number Air cooled condenser unit consisting of condenser fan, copper condenser coils, including pressure testing, gas charging with R 410A refrigerant suitable for operation on 3 phase, 415 V, 50 Hz A.C supply etc. complete as required along with the along with the outdoor unit.
VPS LD Control Room
Installation, testing and commissioning of Air cooled ductable floor mounted package unit, comprising of scroll compressors of 5.5 TR (Nominal) capacity, cooling coil, evaporator, blower and washable/cleanable filter all housed in a powder coated sheet metal cabinet of robust construction and one number Air cooled condenser unit consisting of condenser fan, copper condenser coils, including pressure testing, gas charging with R 410A refrigerant suitable for operation on 3 phase, 415 V, 50 Hz A.C supply etc. complete as required along with the outdoor unit.
Installation of 18 G Hard Drawn Copper Piping between Indoor & Out Door for Suction & Discharge Lines of suitable size as per manufacturers' standards including all fitting & accessories. Copper Piping should be suitably supported at regular intervals. The Copper pipe should be insulated with 13 mm thick nitrile rubber insulation.
LOW SIDE
Installation of indoor hanging rod
Installation of Canvas Connection
Installation of 22 Gauge ducting with supports, nuts, bolts & gaskets complete as required.
Installation of 24 Gauge ducting with supports, nuts, bolts & gaskets complete as required.
Installation of Thermal Insulation with Nitrile Rubber
Installation of Acoustic Insulation for plennum
Installation of soft drawn Copper refrigerant piping with 9 mm thick tube nitrile rubber cover including accessories bracing between indoor and outdoor air-cooled condensers of the following size with necessary supports & fittings as required.
Installationof 11/8 " dia soft copper pipeline with insulation.
Installationof 7/8 " dia soft copper pipeline with insulation.
Installationof 5 /8 " dia soft copper pipe line with insulation.
Installationof 1/2 " dia soft copper pipe line with insulation.
Lifting and Shifting of ODU
Installation of 4 core x 10sq. mm PVC insulated, PVC sheathed, unarmoured copper conductor multi core cable for providing connections to existing AC units between indoor unit and outdoor units including connections, testing, earthing etc. as required.
Installation of control cable between indoor and out door units of size 3 core x 2.5 sqmmXLPE/PVC insulated copper conductor in PVC conduit including accessories like cable glands & Lugs etc. as required.
Installation of control cable between indoor and out door units of size 3 core x 1.5 sqmmXLPE/PVC insulated copper conductor in PVC conduit including accessories like cable glands & Lugs etc. as required.
Laying and fixing control cum transmission cable between indoor and out door units of size 4 core x 10sqmm. XLPE/PVC insulated copper conductor in PVC conduit including accessories like cable glands & Lugs etc. as required.
Installation of Sequencer Units for UPS room for 8 hours running operation etc. as required.
Installation of powder coated aluminium grills / diffusers
Installationof MS Stang for Outdoor Unit
Installation of Volume Control Damper
Installationof AHU 22 TR for Transformer room
Installationof AHU 17 TR for SCADA Control room
Installationof AHU 11 TR for REMC Control room
ELECTRICAL DISTRIBUTION SYSTEM
Installation of 100 Amp 4P MCCB with enclosure and rotary handle.
Installation ,Testing and commissioning of UPS Electrical Distribution System Panel as per SLD.
Installation ,Testing and commissioning of AC Electrical Distribution System Panel as per SLD.
Installation of 4 way TPN DB, incomer 63 Amp 4P RCCB, 30 mA 1 no. and outgoing 32 Amp SP MCB D Curve 12 nos with all accessories.
Installation of 8 way TPN DB, incomer 63 Amp 4P RCCB, 30 mA 1 no. and outgoing 32 Amp SP MCB D Curve 24 nos with enclosure and all accessories. for communication room
Installation of IP based intelligent PDUs of 230V AC, 32amps, 24 Outlets (20 x C13 and 4 x C19, 32A IEC 60309 plug P + N + PE, 7.4 kVA, zero U vertical IPDU, Ethernet, serial and sensor connections.
Fixing of industrial socket 32 amps, 230 V, 1P+N+E IEC 309, industrial Socket with Plug, including the cost of supplying and fixing metal box, mounted on wall/under raised floor/Cable Tray.
Fixing of industrial socket 16 amps, 230 V, 1P+N+E IEC 309, industrial Socket with Plug, including the cost of supplying and fixing metal box, mounted on wall/under raised floor/Cable Tray.
Installation of 4 Core x 35 sqmm cu armoured cable from UPS to UPS Distribution Panel
Installtion of 4 Corex 16 sqmm cu armoured cable UPS distribution Panel to Distribution Panel of each rooms DB.
Installtion of 3 Corex 6 sqmm cu armoured cable DB to 32A industrial socket
Installtion of 3 Corex 4 sqmm cu armoured cable DB to 16A industrial socket
Installation of Copper plate earthing 600x 600x3.15mm for UPS with suitable size of copper strip earth pit as per IS 3043. The earth pit shall be provided with water pipe (Class B) with wire mesh funnel 12SWG copper wire up to chamber, disconnecting link with 600 x 600mm (clear) RCC Chambers and 3mm thick heavy-duty CI checker plate cover with hinge.
Installationof 25 X 3 mm Cu Strip with all accessories
Installation of 1C X 6 Sqmm Cu Flex PVC Insulated Cable for earthing
6 Amp. point wiring with 3x1.5 Sq.mm. PVC Copper wire and 6 Amp Switch &socet complete with earthing etc (Full Pt )
16 Amp.point wiring with 3 x 2.5 Sq.mm copper wire and with 25 Amp , "Modular " Type switch and socket as per requirement
Installation of Automatic Transfer Switch (ATS) 6 KVA 1U rack mount
Installation of all type Cable end termination of the PVC insulated PVC sheathed copper conductor armoured / flexible cables of 1100-volt grade including supplying and fixing of single Compression Heavy Duty Copper lugs with Compound complete as required.
Maintainance services:Overall system preventive & breakdown maintenance services after the expiry of standard guarantee/ warranty period of the system (excluding of item/material/equipment already covered for performance guarantee of 5 years for which the successful bidder shall provide services, if required free of cost up to its guaranteed performance period) for 3 years by monitoring the system on a daily basis by deploying a competent person on chargeable basis
TOTAL AMC CHARGES FOR 3 YEARS
Daanish Electricals and Sales Pvt. Ltd
SD Infra & MEP Services Ltd
Daanish Electricals and Sales Pvt. Ltd
SD Infra & MEP Services Ltd
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid