| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹49.9 LAccepted-AOC 129 STREET NO 3 3 GREEN AVENUE BIBI WALA ROAD BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L-1 | Accepted-AOC Being lowest and reasonable. | |
| 2 | L-2₹51.6 L+₹1.7 L (3.42%)Rejected-Finance | L-2 | Rejected-Finance Not being lowest bidder. | |
| 3 | L-3₹52.7 L+₹2.7 L (5.49%)Rejected-Finance 1946 KAMAL CINEMA STREET BATHINDA CITY BATHINDA PUNJAB | BATHINDA | BATHINDA | PUNJAB | 151001 | L-3 | Rejected-Finance Not being lowest bidder. | |
| 4 | L-4₹55.2 L+₹5.3 L (10.6%)Rejected-Finance | L-4 | Rejected-Finance Not being lowest bidder. | |
| 5 | L-5₹56.8 L+₹6.9 L (13.8%)Rejected-Finance 64 SHAHEED UDHAM SINGH MARKET NEAR OLD BUS STAND BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L-5 | Rejected-Finance Not being lowest bidder. |
Tender Value
₹64.5 L
EMD Value
₹1.2 L
Closing Date
19 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bathinda
HQ CWE Bathinda Bathinda Mil Stn
SPL REPAIR TO BLDG NO. P-01 AGAINST (JOB NO 81 SA/BTD/SR(BLDG)13/2024-25) UNDER GE(S) BATHINDA AT BATHINDA MIL STN
2025_MES_704248_1
CWE BTD/TOKEN-64/2024-25
Open Tender
Civil Works
Item Rate
300 days
Bathinda Mil Stn
As per NIT
7 documents required · 7 mandatory
₹1,000
GE (S) Bathinda
₹1.2 L
HQ CWE Bathinda
30 Jul 2025
12 Apr 2025
21 May 2025
12 Apr 2025
19 May 2025
5 May 2025
22 Apr 2025
Amount
Taking down chowkhats or frames with shutters of PVC door , wooden door shutter, wooden window shutter , Mild steel window and Mild steel ventilators (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed by Engineer-in- charge.
Supply and fixing for steel rolling shutters with ball bearing, as specified including top cover and 1.00 MM thick lathanchoring rod hasp and staple and gear operated type with bevel gear box and crank handle , lock, hold fast, complete all as specified in SSR Part-I (2009) para 10.23 including PCC block, erected in position as directed including one shop coats of primer both sides on exposed surfaces including taking out old defected/rusted shutter and making good the disturbed wall surfaces (brick, plastering and painting work as per existing) complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for preparation of steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chromate primer complete all as specified and as directed by Engineer-in-charge.
Taking down wooden shutters only of any description area exceeding 1.0 sqm and not exceeding 2.0 sqm each complete all as specified and as directed by Engineer-in- charge.
Supply and fixing Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws including taking down old unservicable asbestes cement sheet complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Plain Galvanised sheeting 0.50mm thick in ridges, hips,valley gutter, drip and straight flashing (length and girth fixed) including taking down old unservicable asbestes cement sheet complete all as specified and as directed by Engineer-in-charge.
Taking down cement plaster of any description on brick or concrete surfaces, etc. including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed by Engineer-in-Charge
Material and labour for 15mm thick Rendering in Cement mortar 1:6 on fare face of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
Material and labour for Rendering 15mm thick in cement mortar in 1:4 on other than fare face of brick work or concrete surfaces even and smooth without using extra cement with using integral water proofing compound complete all as specified and as directed by Engineer-in-charge.Note : WPC shall be measured and paid separately.
Material and Labour for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces as in ceiling and finishing the surface even & smooth complete all as specified and as directed by Engineer-in- charge.
Supply only liquid water proofing compound complete all as specified and as directed by Engineer-in-Charge.
Demolition of brick work masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and as directed by Engineer-in- charge.
Material and Labour Brick work with sub class ‘B’ burnt clay old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed by Engineer-in- charge.
Material and Labour for 75 mm thick PCC 1:3:6 , Type C-1 using 20 mm graded stone aggregate as in plinth protection, finishing the surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in- charge.
Material and labour for Waterproofing treatment to sunken floor using acrylic based multipurpose polymer. The treatment shall be carried out as per manufactures specification. The treatment shall be include of the following elements also: 1. Surface preparation of substrate by removing all traces of contaminates, loose and friable particles, cement laitance oils and grease, water repellent coatings etc 2. Injection grouting using cementitious grout if required. The payment for injection grouting shall be made separately etc 3. Repair to the substrate, filling of blow holes/voids and surface leveling using appropriate products specified by the manufacture. 4. All intersections of horizontal and vertical surface should be profiled with a mortar fillet of minimum 25mm x 25mm. 5. The moisture content of the substrate shall be checked before application of first coat at water proof coating at the rate of 200 g/m2 followed brush topping at 450g/m2 per mm. The second coat shall be reinforced with glass fabric between the first and second coat. 6. The treatment shall be protected by application of polymer modified cement mortar of thickness 10mm applied at the rate of 50g per mm. 7. Tech specification : Tensile adhesion strength 0.5N/Sqmm (as bonding slurry).
Material and labour for Aerated Autoclaved Concrete (AAC) blocks work according to Indian Standard specification IS:2185(Part-3)-1984 and latest revision built in Cement and sand mortar 1:6 with Aerated Autoclaved Concrete (AAC) blocks straight or curver on plan exceeding 6mtr Mean radius as in sunken floor complete all as specified and and as directed by Engineer-in-charge.
Demolition of cement concrete un- reinforced of any description and in any position not otherwise specifically provided for and including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for Providing and fixing aluminium work with Polyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conformikng to IS:733 and IS :1285, fixing with dash fasteners of required dia and size,including necessary filling up the gaps at junctions i.e at top , bottom and sides with required EPDM rubber / neoprene gasket etc. Aluminium sections shall be smooth , rust free, straight, mitred and jointed mechanically wherever required including aluminium cleat angle, aluminium snap beading for glazing/ paneling , C.P. brass/ stainless steel screws, all complete all as specified and directed by Engineer-in-charge . Note :- (i) Weight of aluminium sections , aluminium cleat angles , aluminium butt hinges, aluminium handles , aluminium tower bolts , aluminium peg stays & aluminium snap beading shall be physically ascertained through a board of officers convened by GE and payment shall be made only after ascertaining the actual weight of aluminium at site. (ii) The rate of material and labour for providing the EPDM rubber, neoprene gasket , C.P. brass / stainless steel screws are included in this item and nothing shall be paid extra on this account. (iii) During considering the weight of aluminium sections , aluminium cleat angles , aluminium butt hinges, aluminium handles , aluminium tower bolts , aluminium peg stays & aluminium snap beading , the weight of EPDM rubber, neoprene gasket , C.P. brass/ stainless steel screws shall not be considered for measurments and payments. Only the weight of the aluminium sections , aluminium cleat angles, aluminium butt hinges, aluminium handles , aluminium tower bolts , aluminium peg stays & aluminium snap beading shall be considered and measurment and payment shall be made accourdingly. (iv) During the weight of aluminium sections , aluminium cleat angles , aluminium butt hinges, aluminium handles , aluminium tower bolts , aluminium peg stays & aluminium snap beading ,the weight of polyester powder coating 50 micron shall not be considered for weight but the rate of material and labour for providing polyester powder coating 50 micron is included in this item and nothing shall be paid extra on this account. (v) Glazing /Paneling and wire mesh shall be measured and paid seperately. (v)The board shall be duly countersigned by GE shall enclosed with Final Bill .
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds complete all as specified and directed by Engineer-in- Charge.
Material & Labour 4.0mm thick Sheet glass,ordinary quality and glazing with oil putty in square not exceeding 0.50 sq. m in each pane complete all as specified and directed.
Supply & fixing for 4.00 mm thick, figured glass, pin head type and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and as directed by Engineer-in- charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding complete all as specified and as directed by Engineer-in-Charge.
Material & Labour for Wet grip ( sutable for wet areas) coloured ceramic tiles 9mm to 10 mm thick square or rectangular of size 300mm x 300mm as in floor with and including 10 mm thick bedding layer using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 and pointed in epoxy grout to match the shade of tile including necessary cutting as per site requirement complete all as specified and as directed by Engineer-in-charge.
Material & Labour for glazed ceramic coloured tiles 9.0 mm to 10.mm thick , size 600mm x 300mm in verticle surface including 10mm thick bedding layer using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 and pointed in expoxy grout to match the shade of tile including necessary cutting as per site requirement etc complete all as specified and as directed by Engineer-in-charge.
Dismantling of brick tiles or terracing tiles single layer on roof , disposal of retrieved material and stacking properly as directed by Engineer-in- charge.
Dismantling of Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof disposal off rubbish upto a distance not exceedomg 500.00mtr where directed ) complete all as specified and directed by Engineer-in- charge.
Material and labour for cement slurry @ 1.2 kg /sqm spreading with bristle brush and rendering 15 mm (average thickness) in cement mortar 1:3 finished even and fair mixing with Liquid water proof compound 200ml per 50 kg cement bag on roof surface complete all as specified and as directed by Engineer-in-Charge. Note :- Liquid water proof compound shall be measured and paid separately.
Material and Labour for Water proofing tratment to existing roof / terrace (material of water proof treatment as approved by GE) Single component, acrylic based, flexible, micro fibre reinforced waterproofing and heat reflective coating system. the treatment shall be carried out as per the manufacturers instructions and shall include the followings: (a) Preparation of substrate and cleaning it off all loose and triable by mechanical means (b) Open the cracks lines to form , V grooves with cutter/hammer/chisel up to 5-10mm and filling with crack filler and PU sealant. (c) application of primer coat @ 0.2 to 0.3 kg/ sqm followed by the first coat @ 0.75kg/ Sqm. (d) The second coat shall be applied @ 0.75 kg / Sqm and reinforced with fabric re-inforcement between the first and second coat. (e) The top coat of primer shall be applied after the second coat dries off @ 0.05-0.08 Kg per Sqm. (f) The material shall adhere to following specification. TECHNICAL SPECIFICATION OF MATERIAL Tensile Strength 1.5 MPa ASTM D412 Elongation at Break > 200% ASTM D412 Adhesion in Peel > 1.5 MPa (on concrete substrate) EN 1542 Crack Bridging Ability Passes upto 3.2mm Width ASTM C1305 Permeability to Water Vapour Passes IS 2645 Water Vapour Transimission ~ 23 g/m²/24hr ASTM E96 Water Absorption < 10% ( by Mass) ASTM D570 Microbiological Resistance No Algae & Fungal Growth ASTM D5590 Solar Reflectance Index 102 ASTM E1980. Note : Complete material shall be approved by GE and procured in bulk and kept in lock and key. Note : The installation company should be trained and authorized by Manufacturer & installation to be carried out as per manufacturers approved method statement. All auxiliary & accessories involved during application should be supplied by single manufacturer as a part of system. Any component used which is not manufactured by the particular manufacturer can only be used with official approval from manufacturer in consultation with GE.
Material and Labour for PCC benching , coping and padding in 1:2:4 Type B-1 (using 20mm graded stone aggregates) as in roof slab finishing the surface even and fair using Liquid water proofing compound complete all as specified and directed. Liquid Water proofing compound shall be measured and paid separetly as supply only under appropriate item of Schedule 'A' BoQ.
Supply and Fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Door Frame /Chowkhat of Size 45mmx70 mm comprising of virgin polymer of K value 58-60 (susension grade ), Calcium Carbonate and nautral fibers ( Wood Powder /rice husk/wheat husk ) and non toxic additives (max toxcity index of 12 for 100 gms ) fabricated with miter joints after applying PVC Solvant cement and screwed with full body threaded star headed SS screws having minimum density of 750 kg /cum and screw withdrawl strength of 2200 N (face ) & 1100 N (Edge) minimum Compressive strength of 508 N /sqmm modulus of elasticity 900 N/Sqmm and resisitence to spread of flame of class A cat with property of being termite / borer proof , water moistur proof and fire retaident and fixed in position With MS hold Fast /SS Dash Fastner incl Supply and Fixing (03 Nos Per Frame ) 100 mm long SS Butt Hinges as specified and as directed by engr-in charge
Supply & Fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) having minimum density of 650 kg /cum and screw withdrawl strength of 1800 N (face ) & 900 N (Edge) minimum Compressive strength of 50 N /sqmm modulus of elasticity 850N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retardant and with and including Supply & Fixing of 02 Nos (per Leaf) Stainless Steel 150mm long Tower Bolt conforming to IS 15833-2009 with and including S&F of 02 Nos. (per Leaf) Stainless Steel 150mm long handle conforming to IS 208-2020 and 300mm Stainless Steel sliding door bolt 12mm dia with and including a minimum of 6 carriage bolts and nuts four on bolt plate and two on stapple plate and fixed conforming to IS 15834-2008 complete all specified and directed by Engineer -in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 15mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 20mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing 16 mm bore CPVC pipe SDR 11and plain CPVC SDR 11 fitting with all fitting and fixed to walls & ceilings or laid in floors complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing 20 mm bore CPVC pipe SDR 11and plain CPVC SDR 11 fitting with all fitting and fixed to walls & ceilings or laid in floors complete all as specified and as directed by Engineer-in-charge.
Supply & fixing in replacement Rotational Moulded Polyethylene water storage tank ISI Marked of capacity 1000 litres (cylindrical vertical, with closed top), hoisted and fixed in position including making inlet and out let connection complete all as specified and as directed by Engineer-in-charge. (Note :- Ball valve and gate valve shall be measured & paid separately under appropriate items of Schedule 'A' BoQ.)
Supply and Fixing Ball valve high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of size 20 mm bore (minimum weight 20mm-210 gram) complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in replacement 15 mm bore chromium plated fancy type stop valve of cast copper alloy screwed down high pressure with crutch butter fly handle screwed both ends for iron pipe or for unions and fixed complete all as specified & directed by Engineer-in-charge.
Supply & fixing in replacement Chromium Plated, soap tray size not less than 160mm, including fixing to wall with CP screws and PVC plug complete all as specified and directed by Engr-in-Charge
Supply and Fixing in replacement 15mm bore chromium plated quarter turn Pillar cock screwed down high pressure, with or without lettered Hot ot Cold with long screwed shanks and flynuts screwed for iron pipe complete all as specified.
Supply and fixing in replacement 15mm bore Bib tap long body cast copper alloy, chromium plated , with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc. complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in replacement 600 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge.
Supply & fixing in replacement Gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for 20mm bore iron pipes complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement 10 litres capacity PVC valveless syphonic action type low level flushing cistern white with inlet, ball valve, float, handle including brackets and 32mm dia PVC flush pipe complete all as specified and directed by Engineer-in-Charge.
Dismantling and disconnecting of existing CI soil vent pipe 100 mm bore fixed to wall,laid in trenches incl all fittings & accessories complete all as specified and as directed by Engineer-in-charge.
Dismantling and disconnecting of existing CI soil vent pipe 75 mm bore fixed to wall,laid in trenches incl all fittings & accessories complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing 110 mm bore of pipe PVC (SWR) type B ring fited pipes single socket in any length with Stack clamps as shown in BTD Drg No. 916 sheet 1/4 to 4/4 and BTD -917 sheet 1/1 of stays to wall at a distance of 100-120mm away from walls compete all as specified and as directed by Engineer - in-charge.
Supply and Fixing 110 mm bore of pipe PVC (SWR) type B bends of any radius / shoe fixed to PVC pipes complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing 75 mm bore of pipe PVC (SWR) type B ring fited pipes single socket in any length with Stack clamps as shown in BTD Drg No. 916 sheet 1/4 to 4/4 and BTD -917 sheet 1/1 of stays to wall at a distance of 100-120mm away from walls compete all as specified and as directed by Engineer - in-charge.
Supply and Fixing in repair 110mm bore,PVC SWR Type-B, junction , TEE and Y (any radius), diminishing pieces or tapers (large bore measured) with oval access door complete complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing in repair 75mm bore,PVC SWR Type-B, bends , junction , TEE and Y (any radius), diminishing pieces or tapers (large bore measured) with oval access door complete complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing in repair 75mm dia PVC SWR Type-B, floor trap with grating incluing jointing to waste pipe fixed in cement concrete 1:2:4 type B1, using 20mm graded stone aggregates complete complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing in repair 110mm dia PVC SWR Type-B, floor trap with grating incluing jointing to waste pipe fixed in cement concrete 1:2:4 type B1, using 20mm graded stone aggregates complete complete all as specified and as directed by Engineer-in-charge.
Supply & Fixing in repairs Branch pieces, PVC SWR Type B single 110 mm bore, equal or unqual, (Y, T, etc) complete all as specified and as directed by Engineer-in-charge.
Supply & Fixing in repairs Branch pieces, PVC SWR Type B single 75 mm bore, equal or unqual, (Y, T, etc) complete all as specified and as directed by Engineer-in-charge.
Supply & fixing Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms) complete all as specified and as directed by Engineer-in-charge.
Taking down chowkhats or frames with shutters of PVC door ,wooden door shutter, wooden window shutter , Mild steel window and Mild steel ventilators (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 Sqm each complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing wash hand basin of size 550mm x 400 mm vitrous China white flat back including brackets, waste coupling & PVC waste pipe of 32 mm dia etc. complete complete all as specified and as directed by Engineer-in-charge.
Supply & fixing vitreous china urinal, half stall type, white, including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, 32 mm dia full threaded PTMT waste coupling (excluding flushing cistern and flush pipe ) and pointing around urinal back in cement mortar,complete all as specified & directed by Engineer-in-charge.
Material and Labour GI tube medium grade 40mm bore,made to shape as in spout pipe in sunken / verandha / Balcony complete all as specified and directed by Engineer-in-charge.
Material and labour for preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using clean cloths and dry paint brush & applying one coat of synthetic enamel paint of approved tint/colour to achieve glossing finish with using paint brush complete as specified and as directed by Engineer-in-Charge.
Material and Labour for Cleaning of existing reinforcement bars in Roof, ceiling, Chajja, Fascia, Fins, Drops and similar items with wire brush / rotary wire brush to make entire circumference surface of bars free from rust scales, loose material, dirt etc., complete and with and including applying alkline rust converting primer on the existing rebar and allowing it to react with rust for 06 Hrs and from a corrosion resistant , insoluble and adherent protective layer including cleaning the reinforcement, wire brushing to remove the rust spalls, complete as per manufacturer's instructions, complete all as specified and directed by Engineer-in-charge. Note:- Mode of measurement per sqm of breaking area of concrete only.
Material and Labour for Providing and application of zinc rich epoxy anti-corrosive protective coating on reinforcement bars as corrosion protection system in 2 coats to the entire circumference surface of bars ( consumption Qty as per manufacturer's instructions but min 0.4 kg / Sqm approx) in roof, ceiling, chajja, Fascia, Fins, Drops, columns, Beams and similar items complete all as specified and directed by Engineer-in-Charge. The product should confirm carbonation resistance of 2mm and bond strength > 1N/Sqmm according to ASTM C-882-78 complete all as specified and directed. Mode of measurment shall be in Kg.
Material and Labour for Apply SBR based bonding agent to the opened grooves in the concrete before filling up with Polymer modified mortar or any other treatment ( consumption Qty as per manufacturer's instructions but min 0.4 kg / Sqm approx) including cleaning the surface to remove dirt, dust or any other impurities on the surface in roof, ceiling, chajja, Fascia, Fins, Drops, columns, Beams and similar items complete all as specified and directed by Eng-in-Charge. Mode of measurment shall be in Kg.
Material and Labour for Rebuilding the section of structural damaged RCC / PCC elements of Roof, ceiling, chajja, Fascia, Fins, Drops repair to spalling concrete to its original size and shape in layers of 10 mm average thickness in 1st layer by providing and applying with pre-batched, one component fiber based repair mortar having compressive strength > = 50 N/Sqmm (28 days) according to ASTM C 109, flexural strength >= 5N / Sqmm (7 days) according to ASTM C-293-79 complete all as specified and directed by Engineer-in-charge. Mode of measurment shall be in Kg.
Supply and fixing Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified & directed by Engineer-in-charge.
Material and labour for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using sanded paper, clean cloths and dry paint brush & applying one coat of synthetic enamel paint of approved tint/colour to achieve glossing finish with using paint brush complete as specified and as directed by Engineer-in-Charge.
Complete removal of existing treatment of any type/description from walls/RCC surfaces/ceiling/chajjas/roof projections etc with mechanical means/grinder complete all as specified and as directed by Engineer-in-charge.
Material and Labour for applying acrylic wall care putty on internal surfaces and external surfaces of walls/ceilings/soffits (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and leveling of surfaces in two or more layers) by using ready made acrylic wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed by Engineer-in- Charge. Make of acrylic wall care Putty : AS descriped in LIST OF MAKES/MANUFACTURERS under Appendix 'B' here-in-after. Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order. (ii)The make of acrylic wall care putty shall be as per the recommendation of manufacturer of paint.
Material and Labour for Preparation of surfaces and applying 02 coats of interior emulsion paint (light shade as approved by GE ) @ 10 sq.m/litre/2 coats by using roller/brush to wall surfaces over with and including one coat of interior emulsion primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using the brands of interior emulsion paint and interior emulsion primer as descriped in LIST OF MAKES/MANUFACTURERS under Appendix 'B' here-in-after complete all as specified and directed by Engineer-in- Charge.
Material and Labour for preparing new plastered surfaces of walls and applying three coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and directed by Engineer-in- Charge..
Material and Labour for for preparing new plastered surfaces of ceilings and applying three coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and directed by Engineer-in- Charge.
Material and Labour for for preparing existing treated surfaces of ceilings including cornices and applying two coats of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Preparation of surfaces and applying 02 coats of exterior emulsion paint ( shade as approved by GE) with highlighter of any approved shade, @ 5 sq.m/litre/2 coats by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over with and including one coat of exterior emulsion primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using the brands of exterior emulsion paint and exterior emulsion primer as descriped in LIST OF MAKES/MANUFACTURERS under Appendix 'B' here-in-after complete all as specified and directed by Engineer-in- Charge.
Taking down carefully copper /aluminium point wiring (light, fan, socket or power point ) complete including fitting such as hylem , sheet switches, ceiling rose, pendent holder sockets, regulator except concealed conduit and sunken boxes etc. complete all as specified and directed by Engineer-in-charge. Note:1.The weight of aluminium scrap and copper scrap for schedule of credit shall be ascertain by BOO as ordered by GE.The copy of BOO duly countersinged by GE shall be enclosed with final Bill.(ii) The rate of cutting chases (as required) and making good surfaces to match with adjoining surface shall be measured and paid seperately under serial item no. 78.00 to 81.00 of BoQ.
Material and labour for concealed Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), in PVC conduit complete with 2.5 sqmm (nominal cross section area ) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked ) drawn through with and including PVC rigid conduit 20mm dia ( heavy duty ) ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories) with all fittings and all accessories i.e pipe bend pipe hook, elbow,junction box, pressed steel powder coated sunken box of suitable size (min 60mm deep, suitable length and 1.2mm thick ) and flush fixed with cement mortar 1:4 , 3mm thick bakelite plastic laminated sheet for mounting with frame and top cover for switches and socket ,fan regulator, for light/fan point controlled by one switch, top cover fixed with brass screws & cup washers including provn of 2.5 sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc with and including cutting chases (as required) and making good surfaces to match with adjoining surface complete all as specified and as directed by Engineer-in- charge .Note for serial item nos. 78.00,79.00,80.00 and 81.00 : (i) switches one way 5 /6 Amp & 15 /16 Amp , two way switches 5 /6 Amp , sockets 5 /6 Amp & sockets 15 /16 Amp shall be measured and paid seperately under respective items of Schedule'A' BoQ.(ii) The rate of cutting chases (as required) and making good surfaces to match with adjoining surface is included in this item and nothing shall be paid extra on this account. (iii) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clips as directed by Engineer-in- Charge.The rate of this element is included in this item and nothing shall be paid extra on this account.
All as per item No 78.00 here- in- before but for one socket outlet 3 pin, 5 Amp 230 volts flush type on same board complete all as specified and as directed by Engineer-in- charge.
All as per item No 78.00 here- in- before but for one socket outlet 3 pin, 5 Amp 230 volts flush type on independent board complete all as specified and as directed by Engineer-in- charge.
All as per item No 78.00 here in before but for one Switch socket combination 2 in 1, 3 pin, 15 Amp flush type universal with cable 4.0 sqmm multistranded copper conductor FRLSH cable on the independent board including provn of 4.0 Sqmm PVC insulated copper conductor FRLSH cable continues as earth wire connected to earth dolly complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing switch piano flush type 5 Amp, ISI marked 230V AC, single pole, one way complete all as specified and as directed by Engineer-in- charge
Supply and Fixing Switch piano flush type , single pole, one way, 15 Amp ISI mark complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing Socket outlet 3 pin, 5 Amp 250 volts flush type complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing Socket outlet multipurpose 2 in 1, 6 pin, 15 Amp 250 volts flush type complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing ceiling rose surface bakelite 65 mm x 50 mm with three terminal complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing in replacement wall mounted LED light fitting 1 x 20 watt, 220 Volt, 6000K . 4 feet with LED tube and batten, environment friendly. energy efficient complete as per manufacturer's instructions with and including connection with flexible twin core copper cable of size 23/.00076 from ceiling rose to fitting complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing LED Panel Light fitting recessed mounted,square shaped of size 595mm x 595mm x 65mm , 36 (±10%) watt, efficacy not less than 90 lumen/watt , extruded Aluminium/polycarbonate, PC diffusor and inbuilt driver complete as per manufacturer's instructions with and including connection with flexible twin core copper cable of size 23/.00076 from ceiling rose to fitting complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing LED Street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrossion resistant complete with IP 65/66 protection with and including bracket made out with and including 40mm bore Galvanised Iron Light grade pipe 1.20 mtr length bent to shape with 02 sets of MS clamps made out of minimum 25mm x 3 mm MS flat iron with suitable bolt and nuts complete with and including connection with copper cable of suitable size from ceiling rose to fitting complete all as manufacturer's instructions ,as specified and as directed by Engineer-in-charge. Note: The rate of 40mm bore Galvanised Iron Light grade pipe 1.20 mtr length bent to shape with 02 sets of MS clamps made out of minimum 25mm x 3 mm MS flat iron with suitable bolt and nuts is included in this item and nothing shall be paid extra on this account.
Supply and Fixing LED flood light fitting sqaure shape 150 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp, with impact and corrossion resistant complete with IP 65/66 protection size fixing at any height upto 15m complete with and including connection with copper cable of suitable size from ceiling rose to fitting complete all as manufacturer's instructions ,as specified and as directed by Engineer-in-charge.
Material and Labour for in repalcement Sub main wiring with two single core of size 6 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade including cuttting, chasing and grouting including non metallic rigid PVC conduit medium quality of size 20 mm dia conforming to 3537 Part-I ISI marked including all fitting such as Tee, Elbow, bend etc drawn in and including one single core of size 6 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade as in contineous earth conductor cable connected to earth dolly complete all as specified and as directed by Engineer-in- charge. (Colour code phase-Red, Neutral-black and Earth as Green) complete all as specified and as directed by Engineer-in- charge. .Notes:-(a) Cost of PVC conduit , conduit accessories and earth wire included in sub main wiring. (b) Three single core 6 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade including non metallic rigid PVC conduit of size 20 mm dia shall be measured as one length.
Supply and Fixing in replacement Sheet metal enclousers made out of CRCA mild steel sheet not less than 1.2mm thick,, double door, powder coated DB SPN 8 way 240 Volt, IP -54, 200 Amps rated bus bar, dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and as directed by Engineer-in- charge.Note: MCB/ Isolators shall be measured and paid seperately under appropriate item of BOQ.
Supply and Fixing in replacement Sheet metal enclousers made out of CRCA mild steel sheet not less than 1.2mm thick,, IP-54 protection, flush mounted for metal door, powder coated DB TPN 4 way, 415 V AC with 200 Amps rated bus bar, Double door, dust and vermin proof suitable for incorporation of Incoming MCCB and outgoing MCB SP/TP and earth & neutral bus bar etc complete all as specified and as directed by Engineer-in- charge.Note: MCB/ Isolators shall be measured and paid seperately under appropriate item of BOQ.
Supply and fixing MCB ‘C’ curve suitable for 230 volts AC supply, 06Amp to 32 Amp, SP with over load and short circuit protection and rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-charge
Supply and fixing MCB ‘C’ curve suitable for 240 volts AC supply, 40Amp to 63 Amp, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, complete all as specified and as directed by Engineer-in-charge complete all as specified and as directed by Engineer-in-charge.
Supply and fixing MCB ‘C’ curve suitable for 415 volts AC supply, 40Amp to 100 Amp, TPN with over load and short circuit protection and rupturing capacity not less than 10 KA, complete all as specified and as directed by Engineer-in-charge complete all as specified and as directed by Engineer-in-charge.
Material and Labour for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia light grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note:- (i) Earth continuity of GI wire 4 mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Taking down Ceiling fan & Exhaust fan, sealing cable end , dismantling blades and removing and deposting the same in E/M store yard of GE South Bathinda complete all as specified and directed by Engr-in- Charge.
Supply & Fixing Ceiling fan of 1200mm sweep complete with blades, down rods, including electronic regulator (modular type, 120w, 2 module) and accessories, 230 Volts, single phase, 50 Hz, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current (BLDC) motor connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of suitable size from ceiling rose / connector, including extra GI / MS pipe down rod, as per site requirement , with and including serial number of fan as issued by Engineer-in-charge and GE office name with red colour permaent marker complete complete all as specified and as directed by Engineer-in-charge.
Notes 1. All old unservicable material obtained from serial item nos.77.00 to 99.00 of BoQ shall be deposited in the store yard of AGE EM GE South Bathinda by the contractor at his own arrangment. Nothing shall be paid extra to contractor on this account.The Board of Officer as ordered by GE (South) Bathinda shall be ascertained the quantity of old unservicable material and shall be depostied accordingly . The Engineer-in- charge shall maintained reocord properly of all unservicable material duly signed by all concerned staff. 2. The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender from total amount of Schedule 'A'/BOQ
rkkataria and sons (BID ID -3295484)
RINKU BROTHERS (BID ID -3295545)
M/s Balvinder Singh Engineer and Contractors (BID ID -3295528)
M/s PANKAJ KUMAR (BID ID -3294663)
M/s Vandana Builders (BID ID -3299891)
M/S VERMA BUILDERS & DEVELOPERS (BID ID -3295371)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .