| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.3 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹36.9 L+₹7.5 L (25.5%)Rejected-AOC 47 HUSENI LAKDA BAZAAR 242 BELLAIS ROAD MUMBAI 08 | MUMBAI | MUMBAI | MAHARASHTRA | 400008 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | Rejected-Technical | - | Rejected-Technical NOT ENLISTED IN CAT C(VII) | |
| 4 | Rejected-Technical SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | - | Rejected-Technical NOT ENLISTED IN CAT C(VII) | |
| 5 | Rejected-Technical | - | Rejected-Technical NOT ENLISTED IN CAT C(VII) |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
2 Sept 2020, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD, MUMBAI-400088
MANNING AND OPERATION OF WATER SUPPLY INSTALLATIONS AT INS TANAJI, FIRE FIGHTING INSTALLATION AND COMPREHENSIVE REPAIRS TO ELECTRIC MOTOR, PUMPS, WATER SUPPLY DISTRIBUTION NETWORK AND CONTROL PANEL AND ALLIED WORKS AT MANKHURD UNDER GE (NW) MANKHURD
2020_MES_367130_1
8993/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (NW) MANKHURD
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹54,000
Yes
22 Sept 2020
6 Aug 2020
4 Sept 2020
6 Aug 2020
2 Sept 2020
21 Aug 2020
6 Aug 2020 - 20 Aug 2020
Amount
Manning and operation of water supply installation with all connected equipments, supply lines, machineries and electric driven pump set and Chlorine dosing plants, various capacity pumps, sumps, over head reservior, service tanks with a well trained and experienced ITI holder of respective trade (01 No/Shift) for 02 shifts of 08 hours as directed by Engineer-in-Charge, depending availability of water from BMC, including Sundays and Holiday, including routine maintenance checks and upkeeping of installation complete all as specified and directed Location : Tanaji pump house, The details of operation of water supply installations comprising the following items/machinery/fittings:- (i) Operating Mono block centrifugal Pumping set of capacity 7.5 HP - 02 Sets (ii) Operating Chemical dozing system - 01 set
Manning and operation of water supply installation with all connected equipments, supply lines, machineries and electric driven pump set and Chlorine dosing plants, various capacity pumps, sumps, over head reservior, service tanks with a well trained and experienced ITI holder of respective trade (01 No/Shift) for 02 shifts of 08 hours as directed by Engineer-in-Charge, depending availability of water from BMC, including Sundays and Holiday, including routine maintenance checks and upkeeping of installation complete all as specified and directed Location : Cheetah 'B' camp,NOFRA and Viduit Pump House The details of operation of water supply installations comprising the following items/machinery/fittings:- (i) Operating Monoblock centrifugal Pumping set of capacity 15 HP-02 Sets (ii) Operating Monoblock centrifugal Pumping set of capacity 10 HP-02 Sets (iii) Operating Monoblock centrifugal Pumping set of capacity 7.5 HP-02 Sets (iv) Operating Monoblock centrifugal Pumping set of capacity 40 HP- 03 Sets (v) Operating Chemical dozing system - 01 set (vi) Filling water to OHT 20000 glns - 01 No
Manning and operation of water supply installation with all connected equipments, supply lines, machineries and electric driven pump set and Chlorine dosing plants, various capacity pumps, sumps, over head reservior, service tanks with a well trained and experienced ITI holder of respective trade (01 No/Shift) for 02 shifts of 08 hours as directed by Engineer-in-Charge, depending availability of water from BMC, including Sundays and Holiday, including routine maintenance checks and upkeeping of installation complete all as specified and directed Location : 'A'Camp pump house The details of operation of water supply installations comprising the following items/machinery/fittings:- (i) Operating Mono block centrifugal Pumping set of capacity 25 HP - 02 Sets (ii) Operating Chemical dozing system - 01 set Note for item no 2 & 3 only-: (i) The quantity given is tentative only and depends on completion of SCADA work thereafter the item will ceased to be operated as per direction of Engineer-in-charge.
Manning and operation of water supply installation with all connected equipments, supply lines,Machineries and electric driven pump set of various capacity pumps, sumps, over head reservior, service tanks with a well trained and experienced ITI holder of respective trade (01 No/Shift) for 03 shifts of 08 hours as directed by Engineer-in-Charge, depending availability of water from BMC, including Sundays and Holiday, including routine maintenance checks and upkeeping of installation complete all as specified and directed Location : NAD Firefighting Pump House The details of operation of water supply installations comprising the following items/machinery/fittings:- (i) Operating main electric fire Pumping set of capacity 75 HP - 02 Sets (ii) Operating Jockey fire Pumping set of capacity 15 HP - 01 Sets Note for item No.01 to 04:- (a) Material such as cotton waste, dress i.e overall combination (navy blue colour), protective clothing, protective shoes, gas mask, gloves, water testing instruments and other instruments etc, as required for maintenance, manning and operation of plant shall be arranged by the contractor from his own sources for which cost of the same shall deemed to be included in the unit rate. No extra amount shall be paid separately on this account. (b) Installation shall be manned including Saturdays, Sunday & Holiday. (c) Proper log sheets for running of the pump to be maintained. (d) Testing of water sample during every water supply delivery time and recording test result in a register and to be get signed by Engr-in-charge. (e) Carry out weekly maintenance of electrical panels installed in pump house and intimate Engr-in-charge immediately for any defects/breakdown/repair required. (f) Carry out tightening of nuts bolts, replace when required, applying gland packing and greasing. (g) The contractor shall be responsible to keep the water supply installation neat and clean on every day. (h) All documentation such as log sheets, daily attendance register shall maintain as per procedure in vogue. (j) If the operator and valve man are found absent from duty, penal recovery shall be made per shift per head are as follows :- (i) Operator - @ Rs 2000 per operation shift per head. (ii) Valve man - @ Rs 1800/- per operation shift per head.
Rewinding of submersible pump set motor by dismantling the pump from the motor taking it to workshop, rewinding the motor with same size of copper enameled winding wire, insulating, varnishing of the same replacement of of bushes and any other spare parts required for smooth functioning of the submersible pump, re-assembling, re-installing at site connecting complete Submersible pump of capacity upto 05/7.5 HP etc complete all as specified and directed.
All as per item No 5.00 above but Submersible pump of capacity upto 10 HP etc complete all as specified and directed.
Supply & Fix fully automatic star delta starter suitable for 25 HP, 440 volt, 3 Ph Elect Motor with Single Phase Protection feature conforming to IS -13947 after taking down old unserviceable one anf fixed to the same location by making electrical connection properly complete all as specified and as directed. Cat No: SS91855 of Make-L&T or equivalent make specified in CA.
All as per item No-7 above but for eletrical motor 10 HP, Model MK1 FASD of L& T Make, CAT Pat: SS96254 or equivalent make specified in CA. etc complete all as specified and directed.
All as per item No-7 above but for eletrical motor 40 HP, Model MK1 FASD of L& T Make, CAT Pat: SS94366 or equivalent make specified in CA. etc complete all as specified and directed.
S&F in repairs DOL starter in sheet steel enclosure AC 3 phase 415 volt 50 Hz suitable for 5/7.5HP complete complete all as specified and directed.
Collecting water sample in clean bottle from location as directed for testing of physical test, chemical test, as per IS-10500-1991 from BMC approved chemical laboratory or any government recognized institute or approved NABL laboratory and submitting test report complete all as specified and directed.
Supply only pH and free chlorine testing kit table type for day to day checking of pool water complete with solution suitable for atleast 200 test complete all as specified and directed. Make:- ION Exchange/Protcom/Astrapool/UV RICH
M&L for scraping/cleaning surface of pipe lines of size 40mm to 100mm size and preparation of entire surface and applying one coat of Synthetic enamel paint ( Sea green colour for suction and discharge pipe lines) including writing, marking in stencil complete as specified and directed.
M&L for scraping/cleaning surface of pumpset, and preparation of entire surface and applying two coat of Synthetic enamel paint ( grey colour and red colour for fan cowl) complete all as specified and directed.
M&L for earthing complete with GI plate electrode of size 600x600x6mm thick burried directly to ground vertically to a depth not less than 2.25 meter below the ground level connected to GI strip 32x6mm size and earthing lead protected with 40mm bore light grade GI pipe filling around with charcoal dust and salt including excavation returning filling of earth and disposal of surplus soil to a distance not exceeding 50 metre and connected to GI strip by means of nuts, bolts and washers to earth plate, as shown in electrical plate No 3 of SSR Part-I 2010, PCC chamber with making PCC M-10 (Nominal Mix) type B-I using 20 mm graded stone aggregate reinforced with 8mm dia mild steel round bar @ 75 mm c/c both ways and 12mm dia mild steel plain bar lifting handle 02 Nos funnels with wire mesh 20 mm dia GI pipe light grade for watering copper lugs with CI frame and testing complete all as specified and directed. Note: GI strip exceeding 7.5m will be measured and paid seperately
Supply and laying , galvanised earth strip 25x4mm fixed on walls or through conduits /pipes etc including necessary fixing acessories complete all as specified and directed.
Supply, installation, testing and commissioning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC,50 HZ, indoor type,cubicle , dust and vermin proof, air ventilation with IP-43 protection fabricated out of 3mm thick CRCA sheet duly powder coated painting , CPRI approved factory fabricated of approved make specified vide Ser No 4 on Page No 107 of CA, hinged door, front and rear opening with locking arrangement, cable alleys, bus bar chamber and switch gear comparments, copper bus bar 300 Amps rating for three phases and 150 Amps for neutral duly covered with heat shrinkable sleeves colour coded fixed on DMC/SMC insulators bottom cable entry holes for incoming and outgoing cables and connecting MCCBs/switch gears with main bus bar by using copper bus links or copper conductor flexible wires of suitable rating and connecting with terminal blocks of appropriate rating by cable lugs, thimbles etc., earthing terminals, affixing danger notice plate, each compartment shall be numbered/lettered for indication and control wiring with flexible copper conductor cables of suitable size and adequate length, control fuses/MCBs and PCC foundation as per site requirement and a clear space to be kept from bottom of panel for proper termination of cables and including cable connection to MCCBs, switch gears with necessary cable glands, lugs, nuts, bolts and washers etc., complete all as specified and directed including comprising of following:- (a) MCCB 100 Amps (Magnetic thermal setting type), 4 Pole, 25 KA, 415 Volts, AC, 50 HZ -01 No (Incoming) (b) MCCB 32 Amps (Magnetic thermal setting type), 3 Pole, 25 KA - 02 Nos. (Out going) (d) MCB TPN 40 Amps -01 Nos.(Out going) (e) MCB SPN 32 Amps - 02 Nos (f) Star Delta Starter for 15 HP Pump- 02 No. (g) Motor protection relay-02 No (h) LED indicator RYB- 03 Nos (j) Time switch with contactor -1 No (k) VAF meter - 1 No Note - The lay out drawing of the panel shall be got approved by the contractor before panel fabrication and shall be CPRI approved factory fabricated of approved make specified vide Ser No 04 on Page No 107 of CA Note : A sum of Rs 7,025.00 towards sch of credit shall be deducted to arrive the contract sum.
Unity Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .