RequiredOEM Annual Turnover Bid to RA enabled No Ultrasound Scanning Machine ( 5 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standards Product certification Both EU CE (With verified number) and US FDA * Certification number and date - * 1/9 Confirmity to Manufacturer's Certification ISO 9001 & ISO 13485 * Confirmity to Performance and safety standards specific to the device IEC 60601-2-37 or equivalent BIS * Performance Parameters Scope of supply General-purpose ultrasonic scanning systems provide two- dimensional (2-D) B- mode images of soft tissues without subjecting patients to ionizing radiation. It intends to primarily for abdominal
Requiredobstetric/gynecologic (OB/GYN)
Requiredsmall-parts
Requiredand vascular imaging * UMDNS Code and names(Hint: This is for indicating the relevant universal medical devices nomenclature for the category of product ) "Scanning Systems
RequiredUltrasonic
RequiredAbdominal [16-241] Scanning Systems
RequiredUltrasonic
RequiredGeneral-Purpose [15-976] Scanning Systems
RequiredUltrasonic
RequiredObstetric/Gynecologic [15-657] Scanning Systems
RequiredUltrasonic
RequiredSmall-Parts [18-052] Scanning Systems
RequiredUltrasonic
RequiredVascular [15-957]" * Types of Probes & Features Applications- Abdomen
Requiredabdominal vascular
Requiredurology
RequiredOB/GYN
Requiredneonatal brain
Requiredsmall parts (breast
Requiredthyroid
Requiredscrotal
Requiredprostate
RequiredMSK) Yes * Flat linear array 5-10 MHz (±2) * Convex array 2.5-5 MHz (±2) * Microconvex array No Yes
RequiredNo Or higher Volume Convex Probe Yes Yes Or higher Volume Linear Probe No Yes
RequiredNo Or higher Volume TV Probe Yes Yes Or higher E- Breast Elastography No Yes
RequiredNo Or higher E- Thyroid Elastography No Yes
RequiredNo Or higher 2/9 Liver Elastography No Yes
RequiredNo Or higher Intraoperative Probe No Yes
RequiredNo Or higher Gel Warmer No Yes
RequiredNo Or higher Dedicated 3-D/4-D No Yes
RequiredNo Or higher Scan Modes B-mode Yes * M-mode Yes * Contrast harmonic imaging with angio mode No Yes
RequiredNo Or higher Tissue harmonic imaging mode Yes * Provision of Harmonic imaging in Linear Probes Yes * Color Doppler imaging (CDI) Yes * Color Doppler 3-D/4-D option Yes * Power Doppler imaging (PDI) Yes * Power Doppler 3-D/4-D option Yes * Continuous wave Yes * Pulsed wave Yes * Duplex mode Yes * Triplex mode Yes * Tissue Doppler imaging Yes * Contrast-enhanced ultrasound (CEUS) option No Yes
RequiredNo Or higher Tissue synchronization
Requiredtissue velocity No Yes
RequiredNo Or higher Gain control in two dimensions for additional level of flexibility for image quality control Yes * "Provision for higher resolution " Real time high frequency 2D * Probes supplied shall be in latest generation bandwidth Yes * Provision for higher sensitivity for low Yes Yes Or higher 3/9 frequency doppler in all probes Number of Channels in color doppler system 128 or more (if channels are being designated as physical channels) 128 or more (if channels are being designated as physical channels) Live 3 D imaging in color doppler system No Yes
RequiredNo Or higher Colour Doppler system with all application packages
RequiredQuad loop for serial studies with high frame rate revies
Requiredharmonic imaging capability in all modes and integrated stress echo package digital storage and retrieval No Yes
RequiredNo Or higher Number of grey shades for sharp contrast resolutions in db 256 or more * High-definition acoustic zoom provision for enlarging sections of 2D and Colour flow images with more acoustic information for greater clarity and detail while maintaining an optimal frame rate Yes * Colour Flow Imaging Optin Yes * Provision of Tissue Colorization (B- Colour) for improved contrast resolution Yes Yes Or higher All application packages should be inbuilt into the system Yes * Cine Loop Features Yes Yes Or higher Cine Loop Memory in MB 100 * Frame grabber facility for post analysis No Yes
RequiredNo Or higher Facility of Various maps for pre and post processing Yes * 4/9 User defined system and application presets for multi-user department Yes * Number of transducer/probe ports 2 2 System should be capable of generating real time live 3- D images No No Contrast agent imaging No Yes
RequiredNo Or higher Color Doppler system with all applications package
Requiredquad loop for serial studies with high frame rate
Requiredharmonic imaging capability in all modes and digital storage and retrieval No * IMAGE DISPLAY AND PROCESSING DICOM 3 COMPLIANT Yes Yes Or higher Adjustable transmit focus Yes * Automated B-mode (2-D) image Yes Yes Or higher Automated CDI image optimization Yes Yes Or higher Automated PW Doppler image optimization Yes Yes Or higher Dynamic receive focus Yes * Grayscale levels 256 * Image magnification (zoom) Yes * Real-time image Yes * Frozen image Yes * Touch Screen No Yes
RequiredNo Or higher Monitor shall have high- resolution Yes * "Provision of Tilt and Swivel monitor should be able to view in all angles and all light conditions" Yes * Monitor display size
Requiredcm (in) 48.3 (19) LCD with handle 48.3 (19) LCD with handle 5/9 Split screen Twin View and Live Quad Screen Twin View and Live Quad Screen Single/dual monitors Single Single Depth
Requiredcm ≥30 (11.8) * Pre processing Yes * Post processing Yes * Selectable dynamic range Yes * Spectrum analyzer Yes * DIGITAL IMAGE STORAGE Yes * Cine loop playback Yes * Max number frames 1500 * Digital storage hard drive
RequiredGB 500 * Speckle-tracking strain and strain rate Yes * Exam protocols Yes * Automated Yes * Digital calipers Yes * Exam presets Yes * Customizable presets Yes * On-screen annotation Yes * DVD/CD Writer No Yes
RequiredNo Or higher Flash Memory Yes * USB connector Yes * "Facility for high definition digital acquisition
Requiredreview and editing of complete patient studies" Yes * Type of processor NA NA RAM capacity of PC in GB (hint: In caase PC not provided put zero) NA NA Processor speed in GHZ NA NA Frame Grabber incorporated No Yes
RequiredNo Or higher Connectivity between USG and PC No Yes
RequiredNo Or higher 6/9 PC with all software inclusive interfaced with USG machine No Yes
RequiredNo Or higher laser Color printer provided with computer for reporting No Yes
RequiredNo Or higher Inkjet printer provided with computer for reporting Yes Yes Or higher CD/DVD Produced should be playable on any system No Yes
RequiredNo Or higher Glossy Colour Print Paper supplied NA NA Dicom Interfacability Dicom to PACS No Yes
RequiredNo Or higher Interfacability Dicom to RIS No Yes
RequiredNo Or higher USG sytem supplied should be upgradable to next generation system on site Yes * Power Requirements Power input
RequiredVAC 220-240VAC
Required50Hz fitted with Indian plug * Resettable over current breaker shall be fitted for protection Yes Yes Or higher Power backup UPS UPS Back up time in minutes 30 30 Suitable Servo Controlled Stabilizer CVT should be provided No Yes
RequiredNo Or higher Miscellaneous Parameters Warranty in years 3 3 Number of installations of the USG machines in Central/State/PSU Govt Hospitals( Note: Seller should supply a performace certificate of the device to the buyer if demanded after placement of order) More than 3 More than 3 7/9 User/Technical/Mainten ance manuals to be supplied in English in hard and soft copy Yes * Demonstration of equipment and training to be provided after completing supplies & Installation before acceptance Yes * The Principal Manufacturer must have direct Presence/approved service center In India Yes * Copies of reports and certifications to be furnished to buyer on demand at time of supplies Yes * Certificate from the principal that spare parts will be available for next 10 years shall be provided at the time of supplies Yes * * Bold specifications are the golden parameters. * Bidders may note that In respect of non-golden Parameters